• Title/Summary/Keyword: fault inspection

Search Result 115, Processing Time 0.021 seconds

Development and Application of the Simulator of Lighting Devices for Automotive Technical Education (차량 정비 기능 교육을 위한 등화장치 시뮬레이터 개발 및 활용)

  • Chae, Soo
    • Journal of Practical Engineering Education
    • /
    • v.8 no.2
    • /
    • pp.91-94
    • /
    • 2016
  • This study is focused on the development and application of automotive lighting system simulator device to help understanding of the repair and overhaul, electrical instrumentation and automotive circuit checks the contents of the automotive electrical system. The purpose of this study is to define the circuit numeracy, circuit repair preparation skills, detachable power, circuit analysis capabilities, inspection and measurement capability, and repair (problem solving) skills, through the cultivation of clean ability to increase the understanding of electrical equipment maintenance circuitry to verify the improvement of the repair. Automotive electrical device requires understanding of the invisible parts, and understanding of the various symbols and complex circuitry to measure the basic checks and repair are indispensable. This paper would likely contribute to help students to gain more interest in the fields that they feel difficult such as basic skills which necessary to cultivate a variety of electrical equipment fault diagnosis of the basic knowledge needed for electric cars practical.

An Application of Solenoid Eddy Current Sensor for Nondestructively Inspecting Deterioration of Overhead Transmission Lines due to Forest Fires (산불에 의한 가공송전선의 열화특성을 비파괴적으로 검출하기 위한 솔레노이드 와류센서의 응용)

  • Kim, Sung-Duck;Kim, Young-Dal;Jeong, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.404-415
    • /
    • 2000
  • This paper describes several performances and nondestructive inspection for deterioration due to forest fires in overhead transmission lines. After discussing corrosion mechanism such as atmospheric and galvanic corrosion for aged ACSR conductors and its detection for them are presented. Through impedance analysis of a solenoid coil, it is shown that the eddy current sensor may be available to inspect severe fault or local corrosion. As the solenoid coil changes its impedance when the test conductor is inserted into the coil, it can be possible to measure deterioration degree caused by forest fires. Tensile strength, extension rate and sensor impedance are tested for some samples degraded by artificial fire. As increasing blazed period to some extent, the strength of aluminum strand begins to be reduced remarkably, while galvanized steel strand holds the similar strength to the initial value, despite of appearing a little loss of zinc layer. In general, it is shown that the sensor impedance would be increased while the tension load of conductor is reduced and the extension rate is contrarily increased. Therefore, the sensor output could exhibit the changes of mechanical performances, and would be used to detect such deterioration caused by forest fire in ACSR conductors built on the ridge of mountains. Finally, it was verified that the solenoid coil could be applicable to obtain any crucial inform for serious deterioration due to forest fires.

  • PDF

Determination of Maintenance Period Considering Reliability Function and Mission Reliability of Electromagnetic Valves of EMU Doors Considering Air Leakage Failure (전동차 출입문 전자변 누기고장의 신뢰도 함수와 임무 신뢰도를 고려한 정비 주기 결정)

  • Park, Heuiseop;Koo, Jeongseo;Kim, Gildong
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.5
    • /
    • pp.569-576
    • /
    • 2017
  • The electromagnetic valve of pneumatic doors of EMUs has a high failure rate due to air leakage because it supplies air on and off to operate the doors repeatedly. The electromagnetic valve is a very important safety component for which a very high reliability is required because failure makes it impossible to operate the passenger cars. However, domestic urban railway operators maintain electronic valves of the EMU door under a fixed cycle with a spare period according to the full overhaul cycle of the EMU. An improvement of the current maintenance cycle was suggested based on the reliability function and mission reliability. Using the statistical program MINITAB for the operational data of EMU line 6, we analyzed the characteristics of the fault distribution and derived the shape and scale parameters of the reliability function. If we limit the specific reliability probability to under a certain failure rate and calculate its statistical parameters, we can calculate the allowable inspection period with mission reliability. Through this study, we suggested a maintenance period based on RCM (reliability centered-maintenance) to improve the reliability of electromagnetic valves from 68% to 95%.

The Improvement of Electrical Point Machine Wiring Set (선로전환기(NS)의 배선세트 개선)

  • Jeong, Rag-Gyo;Park, Gun-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.351-358
    • /
    • 2016
  • An Electrical Point Machine (NS:New-type Switch), which is equipped and operated at railways in Korea, has been used since the 1960s after being imported from Japan. On the other hand, although the mechanical configuration has improved the position motor control circuit, the electrical connection has not been improved, so NS may have a problem, such as the interlocking system of automatic train operation. In addition, NS is the most vulnerable part in the railway system and a huge train accident may occur due to minor defects. The existing NS wiring set of the circuit controller should be checked only if fixed. Therefore, an excessive inspection time only by a Railroad Signal expert is required. In this paper, the improvement of electrical connection in a NS wiring set, such as the position motor control circuit, was developed and the prototype was installed at Seoul Metro in the distance to go section. The results can be used to help make appropriate adjustments. The improvement of the NS wiring set enhance the maintenance efficiency, passenger service and the stability of the signal system as well as reducing the maintenance cost.

Analysis and de lege ferenda of the Acts Related with Spread of MERS in Korea in the Year 2015 - Focused on the Controversial Clauses of Medical Service Act and Infectious Disease Control and Prevention Act - (중동호흡기증후군 2015년 사태와 관련된 의료법령의 분석과 입법론 - 「의료법」 및 「감염병의 예방 및 관리에 관한 법률」의 쟁점 조항을 중심으로 -)

  • Kim, Cheonsoo
    • The Korean Society of Law and Medicine
    • /
    • v.16 no.2
    • /
    • pp.197-225
    • /
    • 2015
  • The presentation of this paper was triggered by the spread of MERS in Korea in the year 2015. The analysis of the present acts related with MERS is necessary in order to cope efficiently with any probable spread of such infectious diseases as MERS in future. The acts that should be analyzed in this paper include 'Medical Service Act' and 'Infectious Disease Control And Prevention Act' (hereafter, IDCAPA). At first the classification of the infectious diseases in IDCAPA should be referred to. The Act does not properly classify them because the scope of concept of each group of the infectious diseases overlaps each other. This overlap should be removed. The present system in IDCAPA is not proper for the efficient notification and reporting of the infectious disease patients. This is so in some viewpoints including the persons obligated to make the notification and reporting, the persons to whom they should notify and report such patients, and the process of notification and reporting. The efficient approach to the information related with the infectious disease is necessary for the rapid prevention of its spread. Cohort isolation and quarantine of the infectious patients and exposed contacts are the strongest and most efficient steps for the prevention of spread of the infectious diseases. One of the great problems related with such steps would be the conflict of powers or attributions, the likelihood of which is inevitable under the present system of IDCAPA. The IDCAPA distributed the power or attribution to take the steps to the three governments including the central government, the metropolitan government and the primary local government. The power should be concentrated in the central government, which could afford financially to compensate for the huge amount of damages caused likely by the steps. The power to take the steps would be actually just a useless thing for its holder without such financial capacity. The remedy for the victims by the fault of spreader should be approached to in the sense of national wealth. The general principle of tort law could not supply the victims with the sufficient remedy because the damages would be likely too huge for the wealth of such spreader to cope with. In future another parliamentary inspection could reveal another problems in the administration by the government of the MERS event in the year 2015. Any problem caused by defect in the legal system of the control and prevention of the infectious diseases should be taken into consideration when the legal system would be reformed in future.

  • PDF