• Title/Summary/Keyword: fault detection

Search Result 1,634, Processing Time 0.031 seconds

A New Dynamic Residual Generator for Process Fault Detection (프로세스고장검출을 위한 새로운 잔차발생기구)

  • 이기상;이상문
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.10
    • /
    • pp.575-582
    • /
    • 2003
  • A new FDOs (fault diagnostic observers) and the residual generation schemes using the FDOs are suggested for the process fault detection and isolation of linear (control) systems. The design method of the FDO is described, first, for the full measurement systems. Then it is extended for the systems with unmeasurable state variables. An unknown input observer is proposed and applied for the extension. The size of the observer bank may be the smallest, specially in full measurement systems, because the order of the proposed FDO is very low. In spite of the simplicity, the scheme provides the same information for the detection and isolation of the anticipated faults as the conventional multiple observer based schemes. The residuals may be structured so that fault isolation can be performed by pre-selected logic. An FDIS using the proposed scheme is constructed for the model of the four-tank system. Simulation results show the practical feasibility of the proposed scheme.

An Experimental Study on the Rule Based Fault Detection and Diagnosis System for a Constant Air Volume Air Handling Unit (룰 베이스를 이용한 정풍량 공조기 고장 검출 및 진단 시스템의 실험적 연구)

  • Han, Do-Young;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.872-880
    • /
    • 2004
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of the air-conditioning system. In this study, an air handling unit fault test apparatus was built and fault diagnosis algorithms were applied to diagnose various faults of an air handling unit. Test results showed the good diagnosis for applied faults. Therefore, these algorithms may be effectively used to develope the real time fault detection and diagnosis system for the air handling unit.

An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier (베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구)

  • Lee, Heung-Ju;Chang, Young-Soo;Kang, Byung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.36-41
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. FDD algorithm can detect refrigerant leak failure, when 20% amount of charged refrigerant for normal operation leaks from the water chiller. The refrigerant leak failure caused COP reduction by 6.7% compared with normal operation performance. When two kinds of faults, such as a decrease in the mass flow rate of cooling water and temperature sensor fault of cooling water inlet, are detected, COP is a little decreased by these faults.

  • PDF

Sampled-Data Fault Detection Observer Design of Takagi-Sugeno Fuzzy Systems (타카기-수게노 퍼지 시스템을 위한 샘플치 고장검출 관측기 설계)

  • Jee, Sung Chul;Lee, Ho Jae;Kim, Do Wan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.1
    • /
    • pp.65-71
    • /
    • 2013
  • In this paper, we address fault detection observer design problem of T-S fuzzy systems with sensor fault. To detect fault, T-S fuzzy model-based observer is used. By introducing $\mathfrak{H}$_ performance index, an observer is designed as sensitive to fault as possible. The fault is then detected by a fault decision logic. The design conditions are derived in terms of linear matrix inequalities. An illustrative example is provided to verify the effectiveness of the proposed fault detection technique.

RNN-based integrated system for real-time sensor fault detection and fault-informed accident diagnosis in nuclear power plant accidents

  • Jeonghun Choi;Seung Jun Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.814-826
    • /
    • 2023
  • Sensor faults in nuclear power plant instrumentation have the potential to spread negative effects from wrong signals that can cause an accident misdiagnosis by plant operators. To detect sensor faults and make accurate accident diagnoses, prior studies have developed a supervised learning-based sensor fault detection model and an accident diagnosis model with faulty sensor isolation. Even though the developed neural network models demonstrated satisfactory performance, their diagnosis performance should be reevaluated considering real-time connection. When operating in real-time, the diagnosis model is expected to indiscriminately accept fault data before receiving delayed fault information transferred from the previous fault detection model. The uncertainty of neural networks can also have a significant impact following the sensor fault features. In the present work, a pilot study was conducted to connect two models and observe actual outcomes from a real-time application with an integrated system. While the initial results showed an overall successful diagnosis, some issues were observed. To recover the diagnosis performance degradations, additive logics were applied to minimize the diagnosis failures that were not observed in the previous validations of the separate models. The results of a case study were then analyzed in terms of the real-time diagnosis outputs that plant operators would actually face in an emergency situation.

Incipient Fault Detection of Reactive Ion Etching Process

  • Hong, Sang-Jeen;Park, Jae-Hyun;Han, Seung-Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.6
    • /
    • pp.262-271
    • /
    • 2005
  • In order to achieve timely and accurate fault detection of plasma etching process, neural network based time series modeling has been applied to reactive ion etching (RIE) using two different in-situ plasma-monitoring sensors called optical emission spectroscopy (OES) and residual gas analyzer (RGA). Four different subsystems of RIE (such as RF power, chamber pressure, and two gas flows) were considered as potential sources of fault, and multiple degrees of faults were tested. OES and RGA data were simultaneously collected while the etching of benzocyclobutene (BCB) in a $SF_6/O_2$ plasma was taking place. To simulate established TSNNs as incipient fault detectors, each TSNN was trained to learn the parameters at t, t+T, ... , and t+4T. This prediction scheme could effectively compensate run-time-delay (RTD) caused by data preprocessing and computation. Satisfying results are presented in this paper, and it turned out that OES is more sensitive to RF power and RGA is to chamber pressure and gas flows. Therefore, the combination of these two sensors is recommended for better fault detection, and they show a potential to the applications of not only incipient fault detection but also incipient real-time diagnosis.

A Novel Fault Detection Scheme for Voltage Fed PWM Inverter (전압형 PWM 인버터의 새로운 고장 검출 기법)

  • Yu, Ok-Sun;Park, Nam-Ju;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • This paper presents a new fault detection scheme for voltage fed inverter to improve the reliability of power electronic system, which is of paramount importance in the wide industrial applications. The proposed method is achieved by using voltage across lower switches in each phase under the switch fault condition. The reconfiguration method is achieved by the four-switch topology connecting a faulty leg to the middle point of DC-link using bidirectional switches. The proposed method has a simple algorithm and fast fault detection time. Therefore, normal operation of the system after faults is continuously achieved by reconfiguration of system topology. The superior performance of the proposed fault detection and tolerance method are proved by simulation.

Fault Detection and Compensation Scheme of Switch Open-fault in VSI for Two-phase Excitation Drive (2상 여자 구동용 전압형 인버터의 스위치 개방고장 검출 및 보상 기법)

  • Lee, Kui-Jun;Park, Nam-Ju;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.74-80
    • /
    • 2007
  • This paper proposes the novel open-fault detection/isolation scheme of inverter switch in two-phase excited VSI. This scheme identify open-fault using voltage sensor at lower switches of each phase according to the operating mode. It has benefit of simple implementation, fast detection and robustness in the load so that stab of the system is improved. Also, at faulty mode, it minimizes faulty effect and makes possible continuous operation through the reconfiguration procedure applying four-switch operation. The validity of proposed fault detection scheme is verified by experimental results.

Development of a Fault Detection and Diagnosis Algorithm Using Fault Mode Simulation for a Centrifugal Chiller (고장모사 시뮬레이션을 이용한 터보냉동기의 고장검출 및 진단 알고리즘 개발)

  • Han, Dong-Won;Chang, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.669-678
    • /
    • 2008
  • When operating a complex facility, Fault Detection and Diagnosis (FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. In this research, FDD algorithm was developed using the general pattern classifier method that can be applied to centrifugal chiller system. The simulation model for a centrifugal chiller system was developed in order to obtain characteristic data of turbo chiller system under normal and faulty operation. We tested FDD algorithm of a centrifugal chiller using data from simulation model at full load performance and 60% part load performance. In this research, we presented fault detection method using a normalized distance. Sensitivity analysis of fault detection was carried out with respect to fault progress. FDD algorithm developed in this study was found to indicate each failure modes accurately.

SIMULTANEOUS FAULT DETECTION AND CONTROL OF LINEAR TIME-INVARIANT SYSTEM VIA DISTURBANCE OBSERVER-BASED CONTROL APPROACH

  • PANG, GUOCHEN;JIAO, YU;ZHANG, HONGZI;CHEN, XIANGYONG;ZHANG, ANCAI;QIU, JIANLONG
    • Journal of applied mathematics & informatics
    • /
    • v.40 no.1_2
    • /
    • pp.47-59
    • /
    • 2022
  • This paper concerns the problem of simultaneous fault detection and disturbance reject control(SFDDRC) for a class of linear time-invariant system. In the framework of fault detection, residual generators are required to be robust to disturbances existing in the system. Different from most of the existing simultaneous fault and control(SFDC) methods, SFDDRC rejects the influences of disturbances on residual generators by disturbance observer-based control(DOBC). This not only effectively improves the accuracy of fault detection, but also solves the problem that most of the existing SFDC methods require that the disturbance must be bounded. Finally, a numerical example is given to verify the validity of the method.