• 제목/요약/키워드: fault contact

검색결과 142건 처리시간 0.026초

YBCO 박막형 초전도 한류기에 적용 가능한 전류리드 제작방안 (A Device of Current Lead for Fault Current Limiter of YBCO Film)

  • 박권배;강종성;이방욱;오일성;김혜림;현옥배
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.219-220
    • /
    • 2002
  • In this paper, we propose non-soldered current lead was introduced which has low contact resistivity for fault current limiters of YBCO film. Carbon/Cu has good thermal conductivity, electrical conductivity and chemically stable, and so forth. Therefore it seems to be suitable material of current lead for current limiters of YBCO film. We have investigated electric field-current in field of 0-130 mT and quench characteristics of a YBCO film. Experimental results show that characteristics of transport is all right using Carbon/Cu-current lead.

  • PDF

고장 난 다리가 있는 사족 보행 로봇을 위한 최적 힘 배분 (Optimal Force Distribution for Quadruped Walking Robots with a Failed Leg)

  • 양정민
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.614-620
    • /
    • 2009
  • The force distribution in multi-legged robots is a constrained, optimization problem. The solution to the problem is the set points of the leg contact forces for a particular system task. In this paper, an efficient and general formulation of the force distribution problem is developed using linear programming. The considered walking robot is a quadruped robot with a locked-joint failure, i.e., a joint of the failed leg is locked at a known place. For overcoming the drawback of marginal stability in fault-tolerant gaits, we define safety margin on friction constraints as the objective function to be maximized. Dynamic features of locked-joint failure are represented by equality and inequality constraints of linear programming. Unlike the former study, our result can be applied to various forms of walking such as crab and turning gaits. Simulation results show the validity of the proposed scheme.

송전선로 철탑기초의 접지저항 해석 (Analysis of the Earth Resistance for the Tower Footing of T/L)

  • 이현구;하태현;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.344-346
    • /
    • 2001
  • The sharing of common corridors by electric power transmission lines and pipelines is becoming more common place. However, such corridor sharing can result in undesired coupling of electromagnetic energy from the power lines to the near facilities. During a fault on any of the transmission lines, energization of the earth by supporting structures near the fault can result in large voltages appearing locally between the earth and the steel wall of any nearby pipeline. This paper presents the outline of the tower footings for the transmission lines having been used in KEPCO and analyzes the earth resistance for operation method of the tower footing, that is contact presence for the anchor and reinforcing rob of the tower and foundation presence of the underground wiring.

  • PDF

The Ages of Fault Activities of the Ilkwang Fault in Southeastern Korea, Revealed by Classification of Geomorphic Surfaces and Trench Survey

  • Ho, Chang;Ree, Jin-Han;Joo, Byung-Chan
    • 한국제4기학회지
    • /
    • 제18권2호통권23호
    • /
    • pp.1-2
    • /
    • 2004
  • The Ilkwang Fault is NNE-striking, elongated 40 Km between Ulsan and Haendae-ku, Busan in southeastem part of the Korean Peninsula(Kim, D.H. et al., 1989; Kim, J.S. et al., 2003). This paper is mainly concemed about the ages of the fault activities especially in the Quatemary, infered from classification of geomorphic surface and trench excavation for the construction of Singori nuclear power plant. The geomorphi surfaces are classified into the Beach and the Alluvial plain, the 10 m a.s.l. Marine terrace, the 20 m a.s.l. Marine terrace, the Reworked surface of 45 m a.s.l. Marine terrace and the Low relief erosional surface, from lower to higher altitude. The Beach and the Alluvial plain are elongated to the Holocene terrace(ist terrace, choi, 2003). The 10 m a.s.l. Marine terrace is correlated to 2nd terrace (MIS 5em 125 Ka. y. B.P., Choi, 1998). The 45 m a.s.l. Marine terace is correlated to the Lower marine terrace (MIS 7,220 Ka. y. B.P., Choi, 2003 or MIS 9,320 y. B.P.) to the Gwanganri terrace(Penultimate interglacial age, 200-200 Ka. Y. B.P., Oh, 1981). The Low relief erosional surface is distributed coastal side, the Reworked surface of 45 m a.s.l. Marine terrace inland side by the Ilkwang Fault Line as the boundary line. But the former is above 10 m higher in relative height than the latter. The 20 m a.s.l. Marine terrace on the elongation line of the Ilkwang Fault reveals no dislocation. A site was trenched on the straight contract line with $N30^{\circ}$ E-striking between the 10 m a.s.l. Marine terrace and the 20 m a.s.l. Marine terrace. Fault line or dislocation was not observable in the trench excavation. Accordingly, the straight contact line is inferred as the ancient shoreline of the 10 m a.s.l. Marine terrace. The Ages of the Fault activities are inferred after the formation of the Ichonri Formation - before the formation of the 45 m a.s.l. Marine terrace (220 Ka. y. B.P. or 320 Ka. y. B.P.). The Low relief erosional surface was an island above the sea-level during the formation of the 45 m a.s.l. Marine terrace in the paleogeography.

  • PDF

비접촉식 전류 검출 장치에 관한 연구 (A Study on the Current Detector with Non Contact Type)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.

3상 전기제어반 전기사고 예방을 위한 계측시스템 설계 (An Instrumentation System Design for Electrical Accident Prevention of 3-Phase Electrical Control Panel)

  • 곽동걸;최정규;김재중;권영준;송강
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.36-37
    • /
    • 2016
  • The main cause of electrical fires are caused due to short circuit and open circuit. This is generates an instantaneous electric arc or spark accompanied with such electric faults. These arcs generate a pressed wire, contact badness, and a weakness in the wire coating etc.. This research proposes a protection circuit to prevent open-phase accident due to contact failure of electromagnetic contactor, tracking arc fault, open-phase within the three-phase electrical control panel which is the most commonly applied in the industry. The proposed circuit also alarms and cuts off of power system when electrical faults occurs. In addition, the proposed circuit is validated by various electric accident simulator.

  • PDF

지형면 분류 및 트렌치 조사에 의한 일광단층의 단층활동시기 추정 (The Ages of Fault Activities of the Ilgwang Fault in Southeastern Korea, Inferred by Classification of Geomorphic Surfaces and Trench Survery)

  • 장호;이진한;안윤성;주병찬
    • 한국제4기학회지
    • /
    • 제18권1호통권22호
    • /
    • pp.21-30
    • /
    • 2004
  • 일광단층은 NNE-SSW 방향으로 한반도 남동부의 울산에서 부산 해운대까지 연장되며 그 길이는 40 Km이다. 본 연구는 신고리 원자력발전소 1,2호기 건설과 관련된 일관단층석의 제4기 활동 여부를 판단하기 위해서, 지형면 분류와 트렌치 조사로 일광단층의 활동시기를 추정한 것이다. 일광역 부근의 해안에서 산록까지는 모래해안 및 충적면, 10m 해성단구면(MIS 5a), 20 m 해상단면(MIS 5e), 45m 해성단구면(MIS 7 or 9)의 변형면, 소기복침식면의 5개 지형면으로 분류된다. 일광단층선을 경계로 기반침식면은 해안 쪽에 분포하는데도 불구하고 내률 쪽의 45m 해성구면의 변형면 보다 비고가 10m 이상 높다. 그러나 동일한 단층선이 지나고 있는 20m 해성단구면은 변위를 나타내지 않는다. 10m 해성단구면과 20 m 해성단구면이 직선적으로 접하는 지대를 트렌치 조사하였으나 단층선이나 퇴적층의 변위를 관찰할 수 없어, 이 지대는 10m 해성단구면의 옛 해안선[구정선(구汀線)]으로 추정한다. 이에 45m 해성단구면 형성기의 고지리(古地理)로는 소기복침식면은 당시의 해수면 보다 높은 '섬' 이였을 것이며, 일광단층은 이천리층 형성 이후-45m 해성단구면 형성기(22만년 내지 32만년 전) 이전에 이루어졌을 것으로 판단한다.

  • PDF

전기적 불완전 접촉에 따른 동산화물의 발열 및 아크 특성 (The Heating of Cu-oxide and Arc Properties according to Electrical Poor Contact)

  • 김완수;박상준;황동현
    • 한국안전학회지
    • /
    • 제34권3호
    • /
    • pp.15-20
    • /
    • 2019
  • As industry is progressing and standards of living are improved, the demand of electrical energy is expected to grow 8-9% annually. Therefore, the importance of electrical fire prevention technology with the ability of the power supply is being emphasized. According to the statistics of fire in Korea, fire occurred about 45,000 cases annually, and electrical fire possessed about 20%. The electrical fire by poor contact has increased gradually, can be connected as great fire to secondarily induce short circuit and earth fault. Then analysis of heating causes of electrical connections between copper and copper alloy is needed. Also, detection and analysis algorithm of oxide at copper alloy are necessary. In this research, in order to understand the characteristics of oxide growth with rising resistance and heating, it is demonstrated that the oxide at electrical connections can cause fire due to arcing.

스마트 제조를 위한 베어링 결함 예지 정비 데이터셋 구축 (Building Bearing Fault Detection Dataset For Smart Manufacturing)

  • 김윤수;배서한;석종원
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.488-493
    • /
    • 2022
  • 제조 현장에 사용되는 전기적 구동 모터는 베어링의 결함 발생 시 시스템 전체의 작동 정지를 초래하게 된다. 제조 환경 작동의 정지는 시간과 금전적으로 막대한 손해를 일으키며 이러한 베어링의 결함 원인으로는 회전 요소들의 지속적인 접촉으로 인한 마모, 과도한 하중 적용, 구동 환경 등 다양한 요소가 될 수 있다. 따라서 본 논문에서는 국내 제조 환경과 유사한 모터 구동 환경을 제작하여, 다양한 원인의 베어링 환경을 모의한다. 또한 구축된 환경을 바탕으로 정상 및 결함 상태에 따라 달라지는 진동 특성의 변화를 센서를 통해 수집하여 베어링 결함 예지 정비를 위한 데이터셋을 제안한다. 진동 특성 수집에 사용된 센서는 Microphone G.R.A.S. 40PH-10을 사용하여 수집하였으며, 다양한 기계학습 모델을 사용하여 제안하는 데이터셋에 훈련된 견본 베어링 예지 정비 시스템을 제작해본 결과, 심층 신경망 모델 기준 시간 영역 92.3%, 주파수 영역 98.3%의 높은 정확도 성능을 보여준다.

저압 배선용차단기 절연회복특성 파악을 위한 절연회복전압 측정기법 연구 (Study on Measurement Method of Dielectric Recovery Voltage to analysis Dielectric Recovery Characteristic of Molded Case Circuit Breaker)

  • 송태헌;조영만;고광철
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.49-54
    • /
    • 2015
  • Molded Circucit Breaker(MCCB) is a most widely used device to protect loads from the over-current in low power level distribution system. When the MCCB interrupts the over-current, the arc discharge occurred between fixed contact and moving contact to create hot gas. By the Lorentz force due to arc current, the occurred arc is bent to the grids. The grids extend and cool and divide it for arc extinguish. In the majority cases, the MCCB protects loads by interrupting the over-current successfully but in some cases the re-ignition is occurred by hot-gas created during process of interruption. The re-ignition arises when the recovery voltage(RV) is more higher than the recovery strength between contacts and it leads to interruption fault. Therefore to find out the dielectric recovery characteristics of protecting device has a great importance for preventing interruption fault. In this paper, we studies measurement method of the dielectric recovery characteristics considering inherent attribute of the MCCB. To measure the dielectric recovery characteristic of MCCB, we makes an experiment circuit for applying the over-current and the randomly recovery voltage. The measurement methode to find out the dielectric recovery voltage of the MCCB was established and the result was based on experiment results.