• Title/Summary/Keyword: fault contact

Search Result 142, Processing Time 0.027 seconds

Design and Construction of Test Field for Low Voltage Under Cable Fault Location Detection (저압 지중케이블 고장 위치 검출 실증 시험장 설계 및 구축)

  • Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6666-6672
    • /
    • 2015
  • Various reflectometry methods to locate power cable fault have been studied. But, most related studies has been verifying by simulation and laboratory test and study in conditions similar with real cable fault filed was not performed due to the absence of cable fault test field. Therefore, this paper design and construct test field for the standardized performance test and the operating education of cable fault location equipments. In the constructed test, open, short, half open and poor contact fault at 100m, 200m location of cable was produced and 1km cable role was installed for maximum distance measurement test. The test field will be used in the development and standardization of cable fault location technology, and te performance evaluation and certificate test of the related equipments.

A Trip Coil Fault Detection of Circuit Breaker (차단기 트립코일 이상감지 장치)

  • Youn, Ju-Houc;Lee, Jong-Hun;Park, Noh-Sik;Lee, Dong-Hea
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.61-68
    • /
    • 2011
  • The circuit breaker of power distribution board is essential part for the protection of electrical disaster from load short, trouble of power system. For the normal operation of circuit breaker, trip coil of the circuit breaker can cut the mechanical contact of circuit breaker from the detection of power system troubles. This paper presents a design and experimental results of trip coil fault detection system for the real time monitoring of the circuit breaker. The designed system is consisted by the trip coil fault detector which is connected to the each circuit breaker and remote monitoring unit. The trip coil fault detector can detect the impedance and operating voltage of the trip coil, and the detected values are compared with the normal state. And the remote monitoring unit can be connected to the 32 channels of trip coil fault detectors by serial communication. From the designed system, the fault and normal states of the trip coil can be remotely monitored in real time. The designed system is verified by the practical circuit breaker of power distribution board. And the results shows the effectiveness of the designed system.

The Okdong Fault (옥동단층(玉洞斷層))

  • Kim, Jeong Hwan;Koh, Hee Jae;Kee, Weon Seo
    • Economic and Environmental Geology
    • /
    • v.22 no.3
    • /
    • pp.285-291
    • /
    • 1989
  • The Okdong Fault is situated in Okdong-Hamchang area, the central part of Korea. The area consists of Precambrian gneisses and granitoids, Paleozoic clastic and carbonate rocks, and Mesozoic clastic rocks and igneous intrusives. The Okdong Fault is situated along contact boundary between the lowermost Cambrian Basal Quartzite and Precambrian basements. Mylonites occur as narrow zone which is extended over 100km and is restricted to within 10m-30m along the Okdong Fault. The main features of mylonites are quartz mylonite derived from Cambrian Basal Quartzite and mylonitic granitoids from Precambrian granitoids. Movement sense is deduced as a sinistral strike-slip movement with evidence of rotation of sheared porphyroclasts, rotation of fragments and S/C-bands. The mylonite zone has been reactivated as fault which reveals oblique-slip movement. The fault resurges as faults which reveals normal(to the NW) and reverse(to the SE) dip-slip movement. Normal faults are dominant in the northern and southern part and reverse or thrust faults are dominant in the central part of the Okdong Fault. The thrust movement can be correlated with the Daebo Orogeny of Jurassic Period. Granites and dyke rocks intruded into Paleozoic and Precambrian rocks during Cretaceous Period.

  • PDF

Fault Prediction Based on Unbalanced Current Detection of Three Phase Heater and Selection of the Protective Device (3상 히터의 불평형전류 검출에 의한 결함예측 및 보호장치의 선정)

  • Lee, Mun Hyung;Jung, Jae Hee
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.28-33
    • /
    • 2015
  • Three phase heaters in 7 buildings of 2 sites were examined for precise diagnosis. The sample size was 626. Precise examinations of current and the heater wiring status revealed contact failures and arcs in equipments that had CUF larger than 10%. Contact failures and arcs may cause electrical fire. Therefore, the correlation between the CUF and the imperfections in heater equipment and its wiring was analyzed for three phase heaters. In addition, the protection devices used for detection of heater imperfections were found to be unsuitable for the purpose. Current status of the protection devices was analyzed, and suggestions for improvements were made for new standards of the protection device selection.

The Analysis of Temperature and Electric Field due to Contact Failure in Power Substation (수변전설비에서 접점 불량에 따른 열 및 전계 분포 해석)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.307-311
    • /
    • 2016
  • Although there are existing Residual Current Protective Device (RCD) including detect electric leakage and elements such as short circuit and surge, the occurrence of incidents caused by electric faults, including fire, are still constant. The purpose of this study is to analyze the causes of accidents through the electric field distribution in the interpretation of the fault contact breaker. Simulation results by the arc fault has shown the convergence of temperature and electric field to the defect. Through their simulation results, the main cause of erosion phenomena in circuit breaker bar is the electric arc by concentration of electric field not due to dissolve by temperature.

A Study on Protection Device for Electrical Fire Prevention on Joint/Contact Badness Faults (접속·접촉불량 사고에 의한 전기화재 방지용 보호장치에 관한 연구)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl;Lee, Seung-Chul;Lee, Bong-Seob;Park, Young-Jic
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.5-6
    • /
    • 2014
  • According to 2013 fire statistical yearbook in the National Emergency Management Agency, the main cause of an electrical fire are classified to short circuit fault, overload fault, electric leakage, partial disconnection, and joint/contact badness. The occurrence factor of fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Devices(RCDs) of high sensitivity type used at single phase (220V) cut off earth leakage and overload but the RCDs can not cut off electric arc or spark to be a main cause of electrical fire. To be improved on such problem, this thesis is proposed to a auxiliary control device for RCD cut off electric arc or spark.

  • PDF

Eddy Current Analysis of Magnetic Plate to Increase Magnetic Force in MCCB (배선용차단기의 구동자계 증가를 위한 자성체 구조물의 와전류 해석)

  • Lee, Se-Yeon;Baek, Myung-Ki;Lee, Bo-Ram;Kim, Young-Sun;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.909-910
    • /
    • 2007
  • To design the Molded Case Circuit Breaker(MCCB) requires electromagnetic analysis in contact system when the circuit breakers interrupt fault currents. This paper has made sure that there are two ways increasing arc driving force, one is a change of contact point and the other way inserts additionally the magnetic plate. Finally, we have carried out the analysis of eddy current to identify a decrease of arc driving force because of fault currents. In this paper, MCCB models have been analyzed base on 3D-FEM by Maxwell program.

  • PDF

Analysis of Fault Current for the Electric Railway Grounding System (전기철도 접지시스템 혼용 운용시 고장전류 해석)

  • 창상훈;김주락;이형수;김정훈
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.704-711
    • /
    • 2000
  • This study is carried out using a circuit model approach. First, the self and shunt impedances of all the conductors in the rail system and the mutual impedances between different conductors are computed. Then, a circuit representing the both rail systems at interfaces including the rails, feeders, protection wires, contact wires, ground wires is built. Auto-transformers in the system are also represented in the circuit model. The circuit model is then 1]recessed using a circuit solver based on a double-elimination method. Several different scenarios are analyzed, including the load conditions and a few fault conditions with different fault locations. The effect of the buried ground wires is also analyzed by comparing the results with and without the presence of the ground wires. The analysis procedure presented in the paper demonstrated an accurate way of computing fault current distribution and EMC at interfaces between both systems. The results presented in the paper can be used as a reference for estimating interference levels in similar rail systems.

  • PDF

Development and Application of Distributed Multilayer On-line Monitoring System for High Voltage Vacuum Circuit Breaker

  • Mei, Fei;Mei, Jun;Zheng, Jianyong;Wang, Yiping
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.813-823
    • /
    • 2013
  • On-line monitoring system is important for high voltage vacuum circuit breakers (HVCBs) in operation condition assessment and fault diagnosis. A distributed multilayer system with client/server architecture is developed on rated voltage 10kV HVCB with spring operating mechanism. It can collect data when HVCB switches, calculate the necessary parameters, show the operation conditions and provide abundant information for fault diagnosis. Ensemble empirical mode decomposition (EEMD) is used to detect the singular point which is regarded as the contact moment. This method has been applied to on-line monitoring system successfully and its satisfactory effect has been proved through experiments. SVM and FCM are both effective methods for fault diagnosis. A combinative algorithm is designed to judge the faults of HVCB's operating mechanism. The system's precision and stability are confirmed by field tests.

A Study on Fault Tree Construction for Track Worker's Risk Assessment (선로 작업자 위험도 예측을 위한 고장수목 구성 연구)

  • Kwak Sang-Log;Wang Jong-Bae;Park Chan-Woo;Cho Yuen-Ok
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.123-126
    • /
    • 2005
  • Recently many accidents have been occurred on track workers, these accidents have strong relationship with increase of train speed, electrification and multiple track portion. As a first step for the safety management, domestic and abroad track worker accidents data are analysed for the risk estimation of track worker. Analysis results shows that contact between track worker and train is the dormant reason. In order to reduce dormant reason fault trees are constructed in this study.

  • PDF