• 제목/요약/키워드: fat measurement

검색결과 431건 처리시간 0.028초

Optical Skin-fat Thickness Measurement Using Miniaturized Chip LEDs: A Preliminary Human Study

  • Ho, Dong-Su;Kim, Ee-Hwa;Hwang, In-Duk;Shin, Kun-Soo;Oh, Jung-Taek;Kim, Beop-Min
    • Journal of the Optical Society of Korea
    • /
    • 제13권3호
    • /
    • pp.304-309
    • /
    • 2009
  • We tested the feasibility of measuring fat thickness using a miniaturized chip LED sensor module, testing 12 healthy female subjects. The module consisted of a single detector and four sources at four different source-detector distances (SD). A segmental curve-fitting procedure was applied, using an empirical algorithm obtained by Monte-Carlo simulation, and fat thicknesses were estimated. These thicknesses were compared to computed-tomography (CT) results; the correlation coefficient between CT and optical measurements was 0.932 for bicep sites. The mean percentage error between the two measurements was 13.12%. We conclude that fat thickness can be efficiently measured using the simple sensor module.

한국과 미국의 식품 섭취 조사 방법 및 지방섭취량의 비교 (A Comparison of the Methodologies in Food Consumption Surveys and Daily Dietary Fat Intake between America and Korea)

  • 박선민
    • Journal of Nutrition and Health
    • /
    • 제29권10호
    • /
    • pp.1121-1131
    • /
    • 1996
  • The nutritional status is America has been monitored by National Monitoring System since 1960's, mainly conducted by United States Department of Agriculture. The data from these programs were computerized and distributed to researchers. Researchers have manipulated and recalculated the data to produce meaningful results. Korean nutritional status has been investigated by National Nutrition Survey ever year, including food consumption, biochemical measurements and demographic variables. The Korean Nutritional Survey has not been organized and integrated as much as the nutritional survey in the United States and its results have been presented no more than as a report. Its raw data should be distributed to researchers and researchers could use the data to get more information. The purpose of this study is to compare the measurement of food consumption in Korean and America using Korean Nutrition Survey and Continuing Survey of Food Intake by Individuals(CSFII), respectively, and to compare the consumption of fat and foods with a high fat content. The fat consumption in the Unite States has been decreased from more than 40% of total energy intake to 35%, while Koreas have consumed more fat according to the economic growth. However, the fat consumption in Korea was still much lower than that in the United States. Korean should pay attention to saturated fat consumption(animal fat), especially rich middle aged men, since they ate meat as much as much as men in the United States according to a recent study. In America availability of food with a low fat content(e.g. low-fat milk) and new recipes along with nutritional education has decreased fat consumption, especially animal fat, any more. Also, each consumption of polyunsaturated fat and saturated fat should be measured since the ratio of them are more important for preventing heart disease and some cancers.

  • PDF

Genetic and phenotypic relationships of live body measurement traits and carcass traits in crossbred pigs of Korea

  • Do, Chang-Hee;Park, Chan-Hyuk;Wasana, Nidarshani;Choi, Jae-Gwan;Park, Su-Bong;Kim, Si-Dong;Cho, Gyu-Ho;Lee, Dong-Hee
    • 농업과학연구
    • /
    • 제41권3호
    • /
    • pp.229-236
    • /
    • 2014
  • This study presents the estimates of heritabilities of body measurement traits and carcass traits, and genetic and phenotypic correlations of those traits for crossbred pigs in Korea. Body and ultrasound (A mode: Piglog 105) measurements in 221 pigs including body weight, length, height and width, three back fat thickness at the points of 4th, 14th rib and chine bone, eye muscle area and lean meat percent were collected at the ages of 70, 145 and 180 days and then slaughtered to measure carcass weight, back fat, belly, collar butt, spare rib, picnic shoulder, hind leg, loin, tenderloin, lean meat yield and intramuscular rough fat content in loin. Genetic analysis was done using a multi-trait animal model. Heritabilties of the body measurements were ranged from 0.331 to 0.559 and three measurements of back fat thickness were also high as range varying from 0.402 to 0.475 for the ages of 145 and 180 days. However, eye muscle area was moderate (0.296) at the age of 180 days. Heritabilities of retail cut yields were also high as ranged from 0.387 to 0.474 and of IMF content in loin was 0.499. Heritabilities of the cut percent traits were ranged from 0.249 to 0.488. Important positive genetic and phenotypic correlations were noted for all carcass yield traits (0.298 to 0.875 and 0.432 to 0.922, respectively). IMF showed low negative genetic correlations with carcass yield traits, such as carcass weight, picnic shoulder, hind leg, loin, tenderloin and lean meat yield whereas low positive genetic correlations with back fat, belly, collar butt and spare rib. Loin, tenderloin and lean meat percent showed negative genetic correlations with carcass weight, back fat thickness, collar butt, spare rib and picnic shoulder percent. The four body measurements at the ages of 70, 145 and 180 days had positive genetic correlations with belly, shoulder butt, spare rib, picnic shoulder and hind leg percent, but negative genetic correlations were shown with loin and tenderloin percent except body measurements at 70 days. The results suggest that carcass yield are negatively correlated with intramuscular fat content, which is a major factor deciding pork quality and the yield of loin and tenderloin are not increased as much as increase in body size. However, the proportions of belly and collar butt are increased with the body size. In conclusion, selection strategy should be designed according to the preference on composition of carcass in each country.

남자 중.고등 학생에 있어서 피부두겹 법에 의한 총지방량 측정 (Total Body Fat Measurement by Means of Skinfolds in The Secondary School Boys)

  • 김진구;남기용
    • The Korean Journal of Physiology
    • /
    • 제2권1호
    • /
    • pp.31-38
    • /
    • 1968
  • Total body fat measurement by means of skinfold thickness was performed in 94 secondary school boys. Hydrostatic weighing was made on the same subject and corrected for residual volume in lung. Skinfold thicknesses at four sites, namely, back, waist, arm and abdomen, were compared with total body fat calculated from the equation given by Keys and Brozek and regression equation were computated. In 48 middle school boys aged between 13 and 16 years and 46 high school boys aged between 16 and 19 years, skinfold thicknesses increased at all 4 sites as age increased. The body density, however, showed different pattern. In middle school ages, body density showed little variation. Density in 13-14 years was 1.0608, in 14-15 years 1.0578 and in 15-16 years 1.0546. In high school ages density in-creased abruptly to 1.0703 (16 yr.), 1.0730 (17 yr.) and 1.0740 (18 yr.). Subsequently 15 years was a boundary for density change and total body fat change. In middle school boys as a group of 48 the observed values were: density: 1.0562, total body fat: 15.9%, mean skinfold thickness at four sites: 6.02 mm. The coefficient of correlation between mean skinfold thickness and density were r=-0.759 and r=0.781 with %fat. The regression equations were : Body $density=-0.00527{\times}Mean$ skinfold thickness (mm)+1.0879, %Fat=$1.933{\times}Mean$ skinfold thickness (mm)+4.26 In high school boys the values were: density: 1.0723, body fat: 10.4%, and mean skinfold thickness: 7.89 mm. Coefficients of correlation between mean skinfold thickness and density were r=-0.868 and r=0.855 with % fat. Thus, Body density=$-0.00365{\times}Mean$ skinfold thickness (mm)+1.1008, and %Fat=$1.326{\times}Mean$ skinfold thickness (mm)-0.064, were obtained. Although skinfold thicknesses at 4 sites showed a continuous increase in absolute value as age increased, relative growth of skinfold at specific site differed. On arm the growth of skinfold showed a decrease and on waist it showed an increase as compared to the mean thickness.

  • PDF

디지털 영상인식 방법을 통한 자세평가 및 운동가동범위 측정시스템 개발 (Development of Posture Evaluation System through Digital Recognition Method)

  • 문영진;이순호;백진호;이종각;이건범
    • 한국운동역학회지
    • /
    • 제14권3호
    • /
    • pp.49-65
    • /
    • 2004
  • The purpose of this study is development of posture evaluation and Range of Motion(ROM) system by using digital vision analysis method. The results of this study are as follows. First, Scoliosis evaluation through this research measurement system represent 3mm error in 7 cervical point and deepest lumbar point, 0.7mm error in other point. This mean this research measurement system have a reliability for scoliosis evaluation. Second, for spine line evaluation on high fat subject, we need reconstrection spine line after measurement for fat thickness in 7 cervical point and deepest lumbar point. Third, In pedioscope error test, it present 0.01848cm in X axis and 0.01757cm in Y axis. This results mean pedioscope have a reliability foot evaluation. Forth, Posture evaluation and Range of Motion measurement system by using digital vision analysis method can fast measure in range of motion and foot evaluation and posture. therefore we can expect this system application in young people posture clinic center and hospital and so on.

임피던스 방법을 이용한 체지방 측정 (Measurement of Body Fat by Impedance Technique)

  • 김덕원;송철규;황수관
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권2호
    • /
    • pp.133-140
    • /
    • 1992
  • Bioelectrical Impedance method for measuring human body composition is based upon the principle that the electrical conductivity of the fat-free mass (FFM) is far greater than that of the (at. Deter- mination o( impedance was nlade in 30 healthy and obese men aged $40.9{\pm}14.7$yr (mean${\pm}$SD) and 25 healthy and obese women aged $44.0{\pm}10.2$ yr. A commercial impedance body fat analyzer was used with a four electrode arrangement that introduced a painless constant current(ImA at 50 kHz) into the body. Linear relationships were found between impudence values and FFM(r=-0.786) and between weight and FFM(r=0.837). Signigicant increases in the correlation coefficients were ob served when the predicator Hta/z was regressed against FFM(r=0.912) where Ht Is height and Z Is impedance. A linear regression equation, FFM=0.586(Htf/z) +0.317(Weight) -1.674(r=0.977), was found. The correlation coefficient of % body fat between the impedance and infrared methods was 0.898. These data Indicate that the bioelectrical impedance technique is a reliable and valld approach for the estimation of human body composition. This method Is safe, noninvasivr, prouides rapld measure menu, requires little operator skill and subject cooperation, and Os portable. Finally measurement of percent body fat was made possible using both the regression equation and a developed impedance measuring device which measures impedance between wrist and ankle.

  • PDF

위전도 측정을 위한 전극간 부착거리에 관한 연구 (Influences of Inter-electrode Distance on Electrogastrography Measurements)

  • 한완택;송인호;김인영
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권4호
    • /
    • pp.341-346
    • /
    • 2009
  • Cutaneous electrogastrography is the measurement of electrical activity of the stomach on the abdominal surface. The validity of cutaneous electrogastrography is dependent upon the quality of the recording technique. The locations of electrodes are an important issue. We examined the influences of the inter-electrode distance of bipolar leads on electrogastrography measurements. The sensitivity distributions of EGG leads were calculated based on a 2D body fat model and evaluated according to the region of interest sensitivity ratio (ROISR). We simulated the ROISR of the inter-electrode distance in relation to various body fat thicknesses. The distance between the electrodes was proportional to the distance between the ROI and the surface of the abdomen. The results imply that inter-electrode distance can be applied in electrogastrography according to human body fat thickness.

Milk Fat Analysis by Fiber-optic Spectroscopy

  • Ohtani, S.;Wang, T.;Nishimura, K.;Irie, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권4호
    • /
    • pp.580-583
    • /
    • 2005
  • We have evaluated the application of spectroscopy using an insertion-type fiber-optic probe and a sensor at wavelengths from 400 to 1,100 nm to the measurement of milk fat content on dairy farms. The internal reflectance ratios of 183 milk samples were determined with a fiber-optic spectrophotometer at 5$^{\circ}C$, 20$^{\circ}C$ and 40$^{\circ}C$. Partial least squares (PLS) regression was used to develop calibration models for the milk fat. The best accuracy of determination was found for an equation that was obtained using smoothed internal reflectance data and three PLS factors at 20$^{\circ}C$. The correlation coefficients between predicted and reference milk fat at 5$^{\circ}C$, 20$^{\circ}C$ and 40$^{\circ}C$ were r=0.753, r=0.796 and r=0.783, respectively. The predictive explained variances ($Q^2$) of the final model, moreover, were more than 0.550 at all temperatures, and the regression coefficients of determination ($R^2$) were more than 0.6 (60%). Our results indicate that milk has different internal reflectance measured in the range of visible and near infrared wavelengths (400 to 1,100 nm), depending on its fat content.

A Basic Study on the Variation of Temperature Characteristics for Attenuation Coefficient and Sound Velocity in Biological Tissues

  • Park, Heung-Ho
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권3호
    • /
    • pp.273-282
    • /
    • 1993
  • This study is concerned with the temperature dependence characteristics of ultrasound parameters in biological tissues, which are basic on the noninvasive deep body temperature estimation. Used parameters are ultrasonic attenuation coefficient and sound velocity In order to accomplishment our purpose, several signal processing methods were used. Attenua4iorl coefficient was estimated by spectral difference method and sound velocity was estimated by P-P method. And we also examined these methods through a series of IN VITRO experi mentis that used tissue-mimicking phantom samples and biological tissue samples. In order to imitate the biological soft tissue two kinds of phantom samples are used, one is agar phantom sample which is composed of agar, graphite, N-propyl alcohol and distilled water, and the other is fat phantom sample which is composed of pure animal fat. And the ultrasound transmission mode and reflection mode experiments are performed on the pig's spleen, kidney and fat. As a result, it is found that the temperature characteristics are uniform in case of phan- tom samples but not in biological tissues because of complicate wave propagation within them. Consequently, the possibility of temperature measurement using ultrasound on biological tissue is confirmed and its results may contribute to the establishment of reference values of internal temperature measurement of biological tissues.

  • PDF