• 제목/요약/키워드: fast signal acquisition

검색결과 83건 처리시간 0.023초

Novel FFT Acquisition Scheme with Baseband Resampling for Multi-GNSS Receivers

  • Jinseok, Kim;Sunyong, Lee;Hung Seok, Seo
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권1호
    • /
    • pp.59-65
    • /
    • 2023
  • A GNSS receiver must perform signal acquisition to estimate the code phase and Doppler frequency of the incoming satellite signals, which are essential information for baseband signal processing. Modernized GNSS signals have different modulation schemes and long PRN code lengths from legacy signals, which makes it difficult to acquire the signals and increases the computational complexity and time. This paper proposes a novel FFT/Inverse-FFT with baseband resampling to resolve the aforementioned challenges. The suggested algorithm uses a single block only for the FFT and thereby requires less hardware resources than conventional structures such as Double Block Zero Padding (DBZP). Experimental results based on a MATLAB simulation show this algorithm can successfully acquire GPS L1C/A, GPS L2C, Galileo E1OS, and GPS L5.

디지털 PN 초기 동기장치의 성능 (Performance of a digital PN Sequence Acquisition System)

  • 김윤관;은종관;류승문
    • 대한전자공학회논문지
    • /
    • 제21권6호
    • /
    • pp.105-114
    • /
    • 1984
  • 본 논문에서는 direct sequence(DS) 방식을 이용한 spread spectrum system에 사용할 수 있는 빠른 초기 동기 방법을 제안하였다. 수식적인 모델을 세우고 해석을 한 후 computer simulation을 거쳐 제안된 system의 성능을 분석하여 sliding correlator에 비해 우수함을 입증하였다. 입력 신호의 signal-to-noise ratio(SNR)가 -18dB에서 초기 동기 시간이 45ms 소요되었다. 이 방법의 hardsware 구현과 실험 결과도 설명하였다.

  • PDF

A Highly Efficient and Fast Algorithm for Implementing a Real-Time Software GNSS Receiver

  • Im, Sung-Hyuck;Jee, Gyu-In;Kim, Hak-Sun;Cho, Sang-Do;Ko, Sun-Jun
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.2
    • /
    • pp.395-398
    • /
    • 2006
  • In this paper, for implementing a real-time software GNSS receiver we propose the highly efficient and fast algorithms such as partial down-conversion, phase rotator, composite I&Q accumulation, Virtual DCO technique, and parallel acquisition using FFT. When the proposed algorithms are used, more 30 tracking channels with 3 tracking arm(early-prompt-late) is operated real-time on Intel 2.8GHz personal computer. Also, the partial down-conversion reduces the FFT size, for parallel acquisition, to 1/8 of conventional FFT-size and the program size includes map is not exceed 1Mbyte. Finally, the proposed real-time software GNSS receiver using the proposed algorithms provides the navigation solution with below 10 meter rms error.

  • PDF

고차의 QAM 시스템을 위한 고속 반송파 복원 (Fast Carrier Recovery for High-Order QAM Systems)

  • 이철수;안재민
    • 한국통신학회논문지
    • /
    • 제35권4C호
    • /
    • pp.371-376
    • /
    • 2010
  • 본 논문에서는 고차의 QAM 시스템을 위한 새로운 고속 반송파 복원 알고리즘을 제안한다. 제안된 방식은 수신 심볼 간 위상차를 이용하여 반송파 주파수 오프셋을 직접 검출하며, 이를 기존의 반송파 복원 방식에 적용함으로써 넓은 주파수 추적 범위와 빠른 수렴 속도를 제공하는 반송파 복원을 수행할 수 있다. 시뮬레이션을 통하여 제안된 반송파 복원 방식이 주파수 오프셋이 크고 신호 대 잡음비가 낮은 상황에서도 짧은 수렴 시간을 가지는 것을 확인하였다.

Evaluation of Modified Turbo Spin Echo Technique Compared with Double Inversion Recovery Technique in Acquisition of Black Blood Brain Vessel Image

  • Choi, Kwan-Woo;Lee, Ho-Beom;Na, Sa-Ra;Son, Soon-Yong
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.148-152
    • /
    • 2016
  • The main goal was to evaluate effectiveness of a modified TSE sequence compared with DIR (double inversion recovery) sequence in acquisition of fast flow brain vessel images using signal void effect. 32 healthy volunteers (10 men and 22 women; mean age of 31 years; ranging between 28-43 years) who underwent black blood DIR sequence (group A) and the modified TSE sequence (group B) were enrolled in our study. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images for both group A and B. The images obtained from group B showed lower SNR values in internal carotid artery than the group A in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the group B than the group A in both of the T1 and T2 weighted images (8.69% and 7.55 % respectively). The qualitative score of all categories were not significantly different between the two groups. Furthermore approximately 49% of the total scan time was reduced from group B. Our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images of brain by using the signal void effect in the modified TSE technique while keeping the diagnostic value of the test.

TMS320C6713DSK를 적용한 평판의 고속 능동 진동제어 (High-Speed Active Vibration Control System of Plate using TMS320C6713DSK)

  • 최형식;허재관;서해용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.918-924
    • /
    • 2009
  • This paper deals with the experimental assessment of the vibration suppression of the smart structures. First, we have presented the paper about the new high-speed active control system that we have developed using the DSP320C6713 microprocessor and a peripheral system composed of a data acquisition system, A/D and D/A converters, piezoelectric (PZT) actuator/sensors, and drivers using PA95. Since fast data processing is very important in the active vibration control of the structures, we utilized the fast processing DSP320C6713 microprocessor as a main processor to the controller and fast peripheral devices for fast control loop. To realize a fast active vibration control, we have analyzed and tested the processing time of the peripheral devices and provided the corresponding test results. Especially, we have focused on achieving the fast signal amplification of the PA95 device since it takes most of loop times of the control system. Finally, we performed numerous experiments of active vibration control of the aluminum plate to validate the superior performance of the developed control system based on previous mode tests of the plate.

심자도 신호획득을 위한 실시간 256-채널 12-bit 1ks/s 하드웨어 (Real-time 256-channel 12-bit 1ks/s Hardware for MCG Signal Acquisition)

  • 유재택
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권11호
    • /
    • pp.643-649
    • /
    • 2005
  • A heart diagnosis system adopts Superconducting Quantum Interface Device(SQUD) sensors for precise MCG(MagnetoCardioGram) signal acquisitions. Such system needs to deal with hundreds of sensors, requiring fast signal sampling md precise analog-to-digital conversions(ADC). Our development of hardware board, processing 64-channel 12-bit in 1 ks/s speed, is built by using 8-channel ADC chips, 8-bit microprocessors, SPI interfaces, and specially designed parallel data transfers between microprocessors to meet the 1ks/s, i.e. 1 mili-second sampling interval. We extend the design into 256-channel hardware and analyze the speed .using the measured data from the 64-channel hardware. Since our design exploits full parallel processing, Assembly level coding, and NOP(No Operation) instruction for timing control, the design provides expandability and lowest system timing margin. Our result concludes that the data collection with 256-channel analog input signals can be done in 201.5us time-interval which is much shorter than the required 1 mili-second period.

Muscle Functional MRI of Exercise-Induced Rotator Cuff Muscles

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권1호
    • /
    • pp.1-9
    • /
    • 2021
  • The aim of this study was to provide a new assessment of rotator cuff muscle activity. Eight male subjects (24.7 ± 3.2 years old,171.2 ± 9.8 cm tall, and weighing 63.8 ± 11.9 kg) performed the study exercises. The subjects performed 10 sets of the exercise while fixing the elbow at 90 degrees flexure and lying supine on a bed. One exercise set consisted of the subject performing external shoulder rotation 50 times using training equipment. Two imaging protocols were employed: (a) true fast imaging with steady precession (TrueFISP) at an acquisition time of 12 seconds and (b) multi-shot spin-echo echo-planar imaging (MSSE-EPI) at an acquisition time of 30 seconds for one echo. The main method of assessing rotator cuff muscle activity was functional T2 mapping using ultrafast imaging (fast-acquired muscle functional MRI [fast-mfMRI]). Fast-mfMRI enabled real-time imaging for the identification and evaluation of the degree of muscle activity induced by the exercise. Regions of interest were set at several places in the musculus subscapularis (sub), musculus supraspinatus (sup), musculus teres minor (ter), and deltoid muscle (del). We used the MR signal of the images and transverse relaxation time (T2) for comparison. Most of the TrueFISP signal was not changed by exercise and there was no significant difference from the resting values. Only the T2 in the musculus teres minor was increased after one set and the change were seen on the T2 images. Additionally, except for those after one and two sets, the changes in T2 were significant compared to those at rest (P < 0.01). We also demonstrated identify and visualize the extent to which muscles involved in muscle activity by exercise. In addition, we showed that muscle activity in a region such as a shoulder, which is susceptible to B0 inhomogeneity, could be easily detected using this technique.

Application of Correlation-Aided DSA(CDSA) Technique to Fast Cell Search in IMT-2000 W-CDMA Systems.

  • Kim, Byoung-Hoon;Jeong, Byeong-Kook;Lee, Byeong-Gi
    • Journal of Communications and Networks
    • /
    • 제2권1호
    • /
    • pp.58-68
    • /
    • 2000
  • In this paper we introduce the correlation-aided distributed sample acquisition (CDSA) scheme for fast cell search in IMT-2000 W-CDMA cellular system. The proposed scheme incorporates the state symbol correlation process into the comparison-correction based synchronization process of the original DSA scheme to enable fast acquisition even under very poor channel environment. for its realization, each mobile station (MS) has to store in its memory a set of state sample sequences. which are determined by the long-period scrambling sequences used in the system and the sampling interval of the state samples. CDSA based cell search is carried out in two stages : First, the MS first acquires the slot timing by using the primary synch code (PSC) and then identifies the igniter code which conveys the state samples of the current cell . Secondly. the MS identifies the scrambling code and frame timing by taking the comparison-correction based synchronization approach and, if the identification is not done satisfactorily within preset time. it initiates the state symbol correlation process which correlates the received symbol sequence with the pre-stored state sample sequences for a successful identification. As the state symbol SNR is relatively high. the state symbol correlation process enables reliable synchronization even in very low chip-SNR environment. Simulation results show that the proposed CDSA scheme outperforms the 3GPP 3-step approach, requiring the signal power of about 7 dB less for achieving the same acquisition time performance in low-SNR environments. Furthermore, it turns out very robust in the typical synchronization environment where large frequency offset exists.

  • PDF

흑혈류영상 획득 시 신호소실을 활용한 고속스핀에코기법의 유용성 (Effectiveness of a fast spin echo technique using the signal void in acquisition of black blood images)

  • 최관우;김윤신;손순룡;이희주;민정환;이종석;유병규
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4313-4319
    • /
    • 2013
  • 본 연구는 흑혈류영상 획득에서 고속스핀에코기법의 신호소실 현상을 이용하여 검사시간을 최소화시켜 환자의 불편을 줄이고 진단적 가치를 유지하고자 하였다. 연구방법은 흑혈류영상을 획득한 환자 32명을 대상으로, 기존의 이중역전회복기법과 새로운 기법인 고속스핀에코기법을 각각 적용한 후, 기법에 따른 혈류의 신호소거 차이를 알아보기 위해 T1, T2 강조영상에서 내경동맥 내강의 SNR과 CNR을 비교 평가하였다. 연구결과, SNR은 고속스핀에코기법이 이중역전회복기법 보다 T1, T2 강조영상에서 11.49%(4.73), 13.66%(6.03) 낮았으며, CNR은 고속스핀에코기법이 T1 강조영상에서 8.69%(15.04) 높았고, T2 강조영상에서 7.55% (13.17) 낮았으나, 통계적 수준에서 두 기법간의 SNR과 CNR의 차이는 유의하지 않았다. 그러므로 흑혈류영상 획득 시 고속스핀에코기법을 이용한다면 진단적 가치는 유지하면서 검사시간을 최소화하여 환자의 불편을 줄일 수 있다고 판단된다.