• Title/Summary/Keyword: fast fourier transformation

Search Result 97, Processing Time 0.03 seconds

A Study of 'Mode Selecting Stochastic Controller' for a Dynamic System Under Random Vibration

  • Kim Yong-Kwan;Lee Jong-Bok;Heo Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.10
    • /
    • pp.1846-1855
    • /
    • 2005
  • This paper presents a new stochastic controller applied on the vibration control system under irregular disturbances based on the mode selection scheme. Measured displacement and frequency characteristics are simultaneously used in designing a mode selecting controller. This technique is validated by applying to the suppression problem of a flexible beam with randomly vibrated circumstances. The presented method, called Mode Selecting Stochastic Controller, uses the frequency measurement of the flexible system based on a Fast-Fourier transformation algorithm. This controller is constructed by combining mode selection method with previous known Stochastic Controller in real time: Numerical simulations and several experiments are conducted to validate the proposed method. The performance of the proposed method is compared with a stochastic controller developed recently. This method was improved compared with previous one.

An algorithm for real time blood flow estimation of LDF (LDF의 실시간 혈류추정을 위한 알고리즘)

  • Kim, Jong-Weon;Ko, Han-Woo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.78-79
    • /
    • 1998
  • This paper describes a real time algorithm for blood flow estimation of LDF(laser Doppler flowmeter). Many algorithms for blood flow estimation are using power spectral density of Doppler signal by blood flow. In these research, the fast Fourier transformation is used to estimate power spectral density. This is a block processing procedure rather than real time processing. The algorithm in this paper used parametric spectral estimation. This has real time capability by estimation of AR(autoregressive) parameters sample by sample, and has smoothing power spectrum. Also, the frequency resolution is not limited by number of samples used to estimate AR parameter. Another advantage of this algorithm is that AR model enhance SNR.

  • PDF

A Continuous Scanning Laser Doppler Vibrometer for Mode Shape Analysis (모드형상분석을 위한 연속 스캐닝 레이저 도플러 진동측정기)

  • 라종필;최지은;박기환;경용수;왕세명;김경석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.274-280
    • /
    • 2002
  • This paper addresses the vibration mode shape measurement technique utilizing a Continuous Scanning Laser Doppler Vibrometer (CSLDV). The continuous scanning capability is added to the conventional discrete Laser Doppler Vibrometer by reflecting the laser beams on the surface of the object using two oscillating mirrors. The bow scanning resulted from the proposed scanning method is eliminated by feedback control. The velocity output signal from the CSLDV is modulated to give the spatial velocity distribution in terms of coefficients which are obtained from the Fast Fourier Transformation of the time dependent velocity signal. Using the Chebyshev series form, the analysis of the vibration mode shape techniques for straight Bine scanning and 2 dimensional scanning are presented and discussed. The performance of the proposed SLDV is presented using the experimental results of the vibration mode shape of a plate

  • PDF

Relationship between EMG Signals and Work during Isokinetic Exercise of Knee Extensor (슬관절 신전근의 등속성 운동 시 발생되는 일과 근전도 신호와의 관계)

  • Won, Jong-Im
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.83-89
    • /
    • 2003
  • An electromyogram (EMG) using surface electrodes is one of the indirect tests most frequently used to ascertain muscle fatigue. An EMG can be used in two ways. The first technique determines the root mean square (RMS), which reflects the amplitude of the EMG signal. The second technique determines the median and mean power frequencies through EMG power spectrum analysis. The purpose of this article is for determine the correlation between work and percent root mean square(%RMS) and between work and MDF of EMG based on muscle contractions. It is used the %RMS, which reflects the amplitude of the EMG signal For MDF, it is used the frequency power spectrum analysis method, which involves the fast Fourier transformation (FFT) of the original Signals.

  • PDF

EDISON Co-rotational Plane beam-Dynamic tip load를 이용한 가진주파수 변화에 따른 외팔보의 자유단 진동 연구

  • Park, Cheol-U;Ju, Hyeon-Sik
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.246-250
    • /
    • 2015
  • In this paper, Timoshenko and Euler-Bernoulli beam theories(EB-beam) are used, and Fast Fourier Transformation(FFT) analysis is then employed to extract their natural frequencies using both analytical approach and Co-rotational plane beam(CR-beam) EDISON program. EB-beam is used to analyze a spring-mass system with a single degree of freedom. Sinusoidal force with various frequencies and constant magnitude are applied to tip of each beam. After the oscillatory tip response is observed in EB-beam, it decreases and finally converges to the so-called 'steady-state.' The decreasing rate of the tip deflection with respect to time is reduced when the forcing frequency is increased. Although the tip deflection is found to be independent of the excitation frequency, it turns out that time to reach the steady state response is dependent on the forcing frequency.

  • PDF

Monitoring of anesthetic depth with q-EEG (quantitative EEG) in TIVA (total intravenous anesthesia) and VIMA (volatile induction/maintenance anesthesia) (완전정맥마취와 휘발성유도/유지마취에서 정량적 뇌파를 이용한 마취심도의 감시)

  • Lee, Soo-Han;Noh, Gyu-Jeong;Chung, Byung-Hyun
    • Korean Journal of Veterinary Research
    • /
    • v.46 no.1
    • /
    • pp.47-55
    • /
    • 2006
  • To evaluate method for monitoring anesthetic depth with quantitative electroencephalography (q-EEG), we recorded processed EEG (raw EEG) and pain score till 100 minutes in beagle dogs anesthetized for 60 minutes with propofol (n = 5, PRO group), isoflurane (n = 5, ISO group) and propofol-ketaminefentanyl (n = 5, PFK group). Raw EEG was converted into 95% spectral edge frequency (SEF) by fast Fourier transformation (FFT) method. We investigated anesthetic depth by comparing relationship (Pearson's correlation) between q-EEG (95% SEF) and pain score. Pearson's correlation coefficients are +0.2372 (p = 0.0494, PRO group), +0.79506 (p < 0.001, ISO group) and +0.49903 (p = 0.0039, PFK group).

A Study of Real Time Mode Selecting Stochastic Controller (실시간 모드 선택 확률제어기에 관한 연구)

  • Kim, Yong-Kwan;Lee, Jong-Bok;Yeo, Woon-ju;Heo, Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1054-1057
    • /
    • 2003
  • A Real Time Mode Selecting Stochastic Controller (RTMSSC) is developed as a new control strategy for a vibrating system under irregular disturbance. Displacement information and frequency characteristics obtained from me::id analysis of the system are used to design a Mode Selecting Controller. This Paper explains design technique of RTNSSC by applying it to the suppression of a flexible beam experiencing random vibration. The RTMSSC is designed by stochastic control from the modal information. The frequency information of the flexible system is utilized from the Mode Selecting Unit (MSU) based on a Fast-Fourier Transformation algorithm. The performance of the proposed technique, RTMSSC, is compared with that of Real Time Stochastic Controller developed recently, which show quite promising results.

  • PDF

Evaluation of the Ambient Temperature Effect for the Autonomic Nervous Activity of the Young Adult through the Frequency Analysis of the Heart Rate Variability (심박변이율 주파수 분석을 통한 실내온도에 따른 건강한 성인의 자율신경계 활동 평가)

  • Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1240-1245
    • /
    • 2015
  • The purpose of this paper is to investigate the autonomic nervous system activity in various ambient temperatures. To evaluate autonomic function, we use the frequency domain analysis of heart rate variability such as FFT(fast fourier transformation), AR(Auto-Regressive) model and Lomb-Scargle peridogram. HRV(heart rate variability) is calculated by using ECG recorded from 3 different temperature room which temperature is controlled in 18℃(low), 25℃(mid) and 38℃(high), respectively. Totally 22 subjects were participated in the experiment. In the results, the most significant autonomic changes caused by temperature load were found in the HF(high frequency) component of FFT and AR model. And the HF power is decreased by increasing temperature. Significance level was increased by increasing the difference of temperatures.

Enhanced FCME Thresholding for Wavelet-Based Cognitive UWB over Fading Channels

  • Hosseini, Haleh;Fisal, Norsheila;Syed-Yusof, Sharifah Kamilah
    • ETRI Journal
    • /
    • v.33 no.6
    • /
    • pp.961-964
    • /
    • 2011
  • The cognitive ultra-wideband (UWB) network detects interfering narrowband systems and adapts its configuration accordingly. An inherently adaptive and flexible candidate for cognitive UWB transmission is the wavelet packet multicarrier modulation (WPMCM). In this letter, we use an enhanced forward consecutive mean excision thresholding algorithm to tackle the noise uncertainty in the wavelet-based sensing of WPMCM systems, and mathematical analysis is performed for primary user channel fading. As a benchmark, we compare the proposed system with a conventional fast Fourier transformation-based system, and performance investigation proves significant improvements when primary and secondary links are subjected to multipath fading and noise.

Automatic Optical Inspection System for Holograms with Multiple Patterns (다중패턴 홀로그램을 위한 자동광학검사 시스템)

  • Kwon, Hyuk-Joong;Park, Tae-Hyoung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.5
    • /
    • pp.548-554
    • /
    • 2009
  • We propose an automatic inspection system for hologram with multiple patterns. The system hardware consists of illuminations, camera, and vision processor. Multiple illuminations using LEDs are arranged in different directions to acquire each image of patterns. The system software consists of pre-processing, pattern generation, and pattern matching. The acquired images of input hologram are compared with their reference patterns by developed matching algorithm. To compensate for the positioning error of input hologram, reference patterns of hologram for different position should be generated in on-line. We apply a frequency transformation based CGH(computer-generated hologram) method to generate reference images. For the fast pattern matching, we also apply the matching method in the frequency domain. Experimental results for hologram of Korean currency are then presented to verify the usefulness of proposed system.