• 제목/요약/키워드: fan ventilation

Search Result 279, Processing Time 0.049 seconds

A study on the characteristics for temporary ventilation of long subsea tunnels - focused on the current situation and improvement requirements (초장대 해저터널의 공사중 환기 특성에 관한 기초연구 - 현황 및 개선필요사항 중심)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Kim, Jong-Won;Lee, Ju-Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.153-166
    • /
    • 2015
  • Long subsea tunnel to be built below the seabed, as compared to the general railway tunnel, is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for the purpose of ventilation and fire safety. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. The longer ventilation distance is, the more fresh air requirement is needed. When supply airflow becomes excessive, duct size is restricted by the limitations of structure clearance and fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In this study, as on ventilation method development suitable for long subsea tunnel, through comparison of temporary ventilation capacity calculation methods during construction phase, domestic and abroad, the application of Swiss SIA 196 code is found suitable for long subsea tunnel. And, through experiment on leakage of the duct connector, we confirmed that the leakage ratio per 100 m of domestic duct connection type is between 1.5~3.0%. Based on S-class duct of SIA 196 code, ventilation distance is 10.2 km, So, ventilation distance can be longer if duct connection method is improved. So, we confirmed that the improvement of leakage ratio is key issue in the construction-phase ventilation of long subsea tunnel.

A Study on the Performance of the Hybrid Ventilation System for Apartment Houses (공동주택의 하이브리드 환기시스템 성능평가 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sang-Hee
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.89-96
    • /
    • 2012
  • The purpose of this study was to evaluate the applicability of hybrid ventilation system in apartment housings and present a design method to improve the performance of hybrid ventilation system using the CFD simulation. As the object of CFD simulation, a small apartment houses with area of $51m^2$ and $81m^2$ were selected and evaluated. The test hybrid ventilation system are window frame natural air supply & duct exhaust hybrid system(Hybrid 1) and window frame natural air supply & bathroom and livingroom exhaust hybrid ventilation system(Hybrid 2). To evaluate the ventilation efficiency, we used the locations of diffuser installed for each system as the variables through the CFD simulation. In the case of Hybrid 1, the ventilation efficiency of the exhaust duct diffuser located on the inside room was higher rather than the exhaust duct diffuser located on the entrance. In the case of Hybrid 2, the most efficient system was the system that the diffuser connecting the bathroom static pressure fan is installed on the center of the living room. The ventilation efficiency of the Hybrid 2 in the case of $51m^2$ type was more than 20% of the Hybrid 1. But, The ventilation efficiency of the Hybrid 2 in the case of $84m^2$ type was more than 14% of the Hybrid 1. Therefore, to apply the Hybrid ventilation, a study that considers various variable should be conducted.

Numerical study for smoke behavior in case of train fires in railway tunnel with axial fan vents (강제환기 통풍구가 설치된 철도터널 열차화재에서 연기거동에 관한 수치해석적 연구)

  • Kim, Dong-Hyeon;Shin, Min-Ho;Moon, Jung-Joo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1998-2004
    • /
    • 2003
  • Numerical study were performed to analyze for fire safety in railway tunnel with forced ventilation vents. For the condition of train fires with heat release rate of 30 MW, unsteady three dimensional analysis were carried out to investigate the effects of smoke movements, the heat transfer and $CO_2$ concentrations and in double track tunnel with two vents. Among three operation modes of forced ventilations at two vents, the exhaust-exhaust mode of the vent represents the best performance for the evacuation of passengers to avoid the fire.

  • PDF

A Study on the Performance of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능에 관한 연구)

  • Yoo, Seong-Yeon;Chung, Min-Ho;Choi, Jae-Ho;Kwon, Hwa-Kil;Lee, Chun-Woo;Lee, Ki-Seong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.245-250
    • /
    • 2003
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. The purpose of this research is to find the performance of paper heat exchanger for exhaust heat recovery, which exchanges latent heat as well as sensible heat. Experimental apparatus comprises heat exchanger model, constant temperature and humidity chamber, fan and measurement systems for temperature, pressure and flow rate. Thermal performance and pressure loss of the paper heat exchanger are measured and compared at various air velocities and outdoor conditions. Experimental results show that paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air.

  • PDF

A Study on the Period of Optimum Defrost of Auto Defrost Unit by the Forced Fan Evaporator (강제 송풍 증발기에 의한 자동제상장치의 최적제상시기에 관한 연구)

  • 구남열;이윤경;하옥남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.329-335
    • /
    • 2003
  • This study is on a experiment which shows to defrost automatically on the optimum time regardless of defrosting method. The result shows that the more defrost layers increase in fin tubes of evaporation, the less the section of the circulating air reduce. Thickness of the frost formation increases, so a pressure difference of ventilation increase, as a result automatic defrosting system sets the time COP drops suddenly up optimum time. Automatical defrosting system can find out the initial related current of evaporator fan motor and the value of load current in the optimum time. And it sets defrosting time, evaporating temperature, and temperature in refrigerator up system requiring value. Consequence of this experiment is that energy consumption with defrost load gets effect of reduction of eleven percent per 25.4 hours compared with common defrosting.

A Study on the Ventilation Performance for Fan flow effect of Model Tunnel(II) (모형도로터널의 환기성능에 미치는 FAN유량에 관한 연구(II))

  • Kim, Se-Jong;Han, Jung-Chul;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.313-318
    • /
    • 2011
  • 도로터널은 반지하 공간으로서 환기에 많은 설비와 구조에 대한 연구가 진행되고 있으며 특히 제트팬의 경우 평상시에는 환기를 담당하고 있다. 또한 화재시에는 화재연기의 유독가스를 효과적으로 차단하는 제연역할을 함으로서 피난에 대한 중요한 역할을 담당한다. 이러한 제트팬의 특성을 정량적으로 유추하고 공학적인 QRA의 수행을 위한 기초적 연구로서 터널내부의 제트팬의 환기특성을 알아보기 위하여 모형실험체의 내부측정을 2/3까지한 전보에 이어 이번 연구에서는 터널내부전체를 측정하여 제트팬이 모형터널내에 미치는 영향을 CFD와 비교한 연구이다.

  • PDF

A study on the effect of welding fume during the welding work (용접시 발생되는 용접흄에 관한 연구)

  • Lee, Gyeong-Man;Lee, Cheol-Gu
    • Proceedings of the KWS Conference
    • /
    • 2007.11a
    • /
    • pp.306-309
    • /
    • 2007
  • It shows not only positive effect with fan as a way of improving condition in workplace but also shows air supply, ventilation condition in welding site with CFD analyzation. Also when the wind blew to the front side by a fan, the welding Hume significantly reduced, As this was examined as CFD and was gone through enough exhaustion to become streamline flow laminar, the toxic materials will be reduced. The improvement of welding work and education are investigated to be more significant factors than wearing protective equipments and setting safety tools to prevent welding works from welding fume exposure.

  • PDF

A Numerical Study on the Ventilation Performance for Fan flow effect of Model Tunnel (모형도로터널의 환기성능에 미치는 FAN유량에 관한 수치적 연구)

  • Kim, Se-Jong;Kwon, Young-Jin;Lee, Ju-Hee
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.21-25
    • /
    • 2010
  • 터널내에 설치되는 제트팬은 비상시에는 연기와 같은 유독가스를 제거하는데 사용되며 평상시에는 장대터널에 있어서 차량에 의해 발생한 오염공기를 제거하는 중요한 역할을 한다. 파량의 피스톤효과에 의해서 일부 제거되기는 하나 1km이상의 장대터널에서는 반드시 필요로 한다. 제트팬의 가장 많은 에너지 손실이 벽면에서 이루어지고 있으며 이를 통하여 터널내에 소실되는 에너지를 정량화하고 그원인 파악과 함께 효율적인 환기설계를 위한 연구이다.

  • PDF

A Study on the Ventilation Performance for Fan flow effect of Model Tunnel (모형도로터널의 환기성능에 미치는 FAN유량에 관한 연구)

  • Kim, Se-Jong;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.123-126
    • /
    • 2010
  • 터널내에 설치되는 제트팬은 비상시에는 연기와 같은 유독가스를 제거하는데 사용되며 평상시에는 장대터널에 있어서 차량에 의해 발생한 오염공기를 제거하는 중요한 역할을 한다. 파량의 피스톤효과에 의해서 일부 제거되기는 하나 1km이상의 장대터널에서는 반드시 필요로 한다. 이러한 제트팬의 효율적인 환기 및 제연설계를 위하여 CFD해석과 더불어 모형실험을 실시함으로서 터널내에 소실되는 에너지를 정량화하고 그 원인 파악과 함께 효율적인 환기설계를 위한 연구이다.

  • PDF

Study on the Development of the Mobile Pig Nursery for Early Weaned Piglet (조기이유 자돈 사육을 위한 이동식 자돈사 개발에 관한 연구)

  • 유용희;이덕수;정일병;이진우;전병수;한정대
    • Journal of Animal Environmental Science
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1998
  • The objective of this study was conducted to develope a mobile pig nursery(MPN) for segregation of early weaned piglet. The units of MPN was consisted of 4 rectangle-type pens, 1 workroom, 2 doors, 3 windows, 1 air-inlet, 1 exhaust fan, and 1 cooling and heating system. Total of 40 piglet were weaned at 7 days of age. The period of the feeding test was 63 days. The results obtained are as follows: 1. The insulation thickness was 70, 70 and 50 mm of roof, floor and wall, respectively. R-value was 15.32 and 10.32 of roof and wall, respectively. 2. Exhaust fan( 30.48) was installed near back door 40cm from the bottom. When exhaust fan speeds were 15, 20, 30 and 35%, Air ventilation was required 9.75, 7.07, 1.72, 1.45 minutes of respectively. 3. Average temperature in the MPN was able to maintain 27∼28$^{\circ}C$ from 7∼28 days of age, 24∼25$^{\circ}C$ from 35∼56 days of age and 20∼21.5$^{\circ}C$ from 56∼70 days of age. 4. Average daily gain, feed intake and feed conversion were 420.6g, 761.5g, 1.81 respectively.