• Title/Summary/Keyword: fan motor

Search Result 252, Processing Time 0.027 seconds

A study on Analysis Technique of Design Parameters for Brushless DC motor (Brushless DC motor의 설계 Parameter 분석 기법에 관한 연구)

  • Maeng, Kyung-Ho;Park, Chang-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.6-8
    • /
    • 2004
  • Recently, it is increasing to use more Brushless DC Motor with high energy density permanent magnet and semiconductor control unit for complementing the mechanical defect of Brushed DC Motors. For designing of BLDC Motors are required complex parameters like as rated characteristic, Geometries, B-H curve of magnet and steel materials, winding factor, etc. Moreover, design and manufacturing are difficult because of additional control circuits. Generally, Design parameters are gotten by analysis of Motor which is used. And the design parameters are used to design a new motor. But getting the design parameters through the eyes and experience is limited and it takes a long time. In this paper a method is proposed to efficiently analyze motor design parameters through the No load and Load Test, Back EMF Test, Simulation Analysis and Patent Analysis Method for existing BLDC Motor for a cooling Fan in Vehicle.

  • PDF

A study on the running characteristics of the single phase induction motor by S.C.R. (S.C.R.에 의한 단상유도전동기의 운전특성에 관해서)

  • Jong Swoo Won
    • 전기의세계
    • /
    • v.17 no.4
    • /
    • pp.7-12
    • /
    • 1968
  • In recent years the development of the SCR has made possible the control of the power system. It is one example that the speed control of the induction motor can be done by changing the frequency with the S.C.R. This paper is devoted primarily to a study of the running characteristics of the single phase induction motor through the experimental and theoretical methods when the speed of the motor is controlled by varying the conduction period in current with S.C.R. under the constant frequency. We conclude from the experiments that the adjustment of the phase angle in current is equivalent to the change of the supply voltage to the motor. Therefore, the speed control of the motor such as a fan duty motor is possibly by this methods.

  • PDF

Study on Noise Reduction by Optimizations of In-line Duct Flow (덕트의 유로 최적화를 통한 소음저감 연구)

  • Han, Jae-Oh;Lee, Soo-Young;Mo, Jin-Yong;Lee, Jai-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.803-808
    • /
    • 2006
  • This paper was a study about noise reduction through flow stabilization in duel using experimental method and numerical analysis at the same time. To determine the fan's type three kinds of fans(axial fan, centrifugal fan, and axial fan with centrifugal type) was examined to investigate the suitability for duct. As a result, under the equal number of rotation 2000 RPM, performance of an axial fan with centrifugal type was the most superior by 55dBA at 4.3CMM among other fans. After this, analyzed the results of the numerical analysis to find out the optimum design of pitch angle such as $0^{\circ},\;10^{\circ},\;15^{\circ}\;and\;20^{\circ}$. The intensity of turbulence was low when pitch angle was $15^{\circ}$ and air volume became peak by 5.08 CMM. It was observed that axis component of velocity increased gradually when pitch angle increased from $0^{\circ}\;to\;20^{\circ}$. Finally, designed the shapes of D/S(Down Stream) in duct that agreed inlet angle($\delta$) of stationary blades with pitch angle($\beta$) of axial fan with centrifugal type and derived flow to duct medial, and changed the shape of motor-mount to reduce occurance of unstable vortex in tip of impeller, and embodied noise reduction and improvement of air flow rate through flow stabilization.

  • PDF

An investigation on development of bus electrical cooling fan system (상용차용 전동 쿨링팬 개발에 관한 연구)

  • Kim, Joo-Han;Jung, In-Soung;Seo, Jung-Moo;Hur, Nahm-Keon;Jung, Jae Hyuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.144.1-144.1
    • /
    • 2010
  • 현재의 세계 자동차 시장은 석유 자원의 고갈과 전자화로 높은 연비의 기술적 성숙을 요구하고 있으며, 이는 미래 자동차 기술의 전동화를 가속시키고 있음에 따라 종래 엔진부하로 사용되는 시스템 및 유압시스템의 전동화 기술추이가 지속적으로 증가하고 있다. 이중 엔진 부하 메커니즘의 하나인 엔진 쿨링 팬 분야는 소비용량이 크고, 고 연비증감 기술증진의 전동화에 따른 차량 성능개선의 효과가 높아 실용 전동화 용의성에 의해 새로운 최우선 차량 전동부하로 나타나고 있다. 특히, 대형 차량(버스, 트럭)의 엔진 Cooling Fan 시스템은 차량 연비저감의 주요원 중에 하나로 대두되고 있으며, 도시 소음의 주된 요인이 되고 있어 전동화 기술개발의 필요성이 매우 높다. 전동 Cooling Fan 시스템은 종래 엔진 구동형 시스템에 비하여 엔진부하를 감소시킬 수 있고, 차량 연비향상 및 유해배출 가스를 저감시킴으로 기술적, 환경적 개발효과가 매우 높다. 본 연구에서는 쿨링팬 고출력 BLDC모터 설계제작에 관한 내용과, 최적 팬 블레이드 설계제작, 마지막으로 개발 전동 쿨링팬 성능평가에 관한 내용이 포함되어 있다.

  • PDF

The Survey of Fire Hazard of Fan in Manufacturing Industries (제조 사업장의 환풍기 화재위험성 조사)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.21-29
    • /
    • 2013
  • The short circuit and overload is presented by main cause of electrical fire. However, 85% of the fan directly connected the outlet box without switch in total 110 fans as a research in manufacturing industries. In installation direction of vertical type fans which was placed on the horizontal surface, only 39 vertical type fans were placed on vertical surface and 71 fans were placed on the horizontal type. The installation direction of the fans warns of the risk of the fire hazard due to the motor stall to the user manual of the maker. However, it is the representative nonconformity example of construction which the people or builder disregards. In addition, the condition of ground connection with the earth leakage prevention was investigated in grounding of 5 fans, non-grounding of 105 fans. The double insulation structure is generally used for small fan and it can't connect ground wire as electric plug of non-grounding type. However, industrial iron fan needs ground wire for electric leakage and to protect against electric shock.

Test Method for Particle Removal Characteristic of Equipment Fan Filter Unit (EFFU) (Equipment Fan Filter Unit (EFFU)의 Particle 제거 성능평가 방법)

  • Lee, Yang-Woo;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.2
    • /
    • pp.59-62
    • /
    • 2012
  • This test method covers a procedure for measuring particle removal characteristic of equipment fan filter unit(EFFU) installed inside of semiconductor process equipments, FPD manufacturing equipments and so on. Since EFFU is a combination of air filter and the assembly of fan, motor and frame, the integrity of these parts is very important for the performance of EFFU. So a conventional particle removal test method for air filters is not suitable for EFFU particle removal performance. This test method defines an evaluation method for EFFU which is installed inside an enclosed space to remove particles that are generated inside process equipment. The particle removal performance of EFFUs is usually depending on the performance of filter media and air flow rate. To understand a performance of an EFFU, the filter media characteristic, air flow rate and the integrity of EFFU parts should be considered simultaneously. This test method is intended to demonstrate the system performance of an EFFU and successfully evaluated EFFU performance characteristics.

New Cooling System Design of BLDC Motor for Electric Vehicle Using Computation Fluid Dynamics Modeling

  • Vu, Duc Thuan;Hwang, Pyung
    • Tribology and Lubricants
    • /
    • v.29 no.5
    • /
    • pp.318-323
    • /
    • 2013
  • Overheating in electrical motors results in detrimental effects such as degradation of the insulation materials, demagnetization of magnets, increases in Joule losses, and decreases in motor efficiency and lifetime. Thus, it is important to find ways to dissipate heat from the motor and to keep the motor operating at its most efficient temperature. In this study, a new design to guide air flow through a given brushless direct current (BLDC) motor is developed and the design is analyzed, specifically by using computational fluid dynamics (CFD) simulations. The results showed that the temperature distribution in the three proposed models is lower than that in the original model, although the speed of the cooling fan in the original model reaches a very high value of $15{\times}10^3$ rpm. The results also showed that CFD can be effectively used to simulate the heat transfer of BLDC motors.

STRUCTURAL SAFTY EVALUATION OF COMPRESSOR DRIVING MOTOR SHAFT SYSTEM (컴프레서 구동용 전동기 축계의 구조 안전성 평가)

  • Jung, Kun-Hwa;Kwak, Ju-Ho;Kim, Byung-Joo;Lee, Jong-Moon
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1031-1036
    • /
    • 2007
  • Torsional vibration analysis is necessary at design stage to ensure the reliability of a system particularly when the driven machine is a reciprocating compressor. This paper contains the results of torsional vibration analysis and fatigue strength evaluation for 540 kW compressor driving motor. Torsional vibration analysis showed that the $2^{nd}$ torsional mode of the entire shaft system has the possibility of resonance with the $14^{th}$ order excitation of compressor and twin line frequency of motor at operating speed. Therefore, the analyses were required to ensure the structural reliability of the motor. The fatigue strength was evaluated for the shaft and inner fans using the results of forced vibration analysis. It is concluded that the motor has sufficient fatigue strength under normal operating condition.

  • PDF

Performance Comparison of Conventional and Segmental Rotor Type Switched Reluctance Motor

  • Jeong, Kwang-Il;Xu, Zhenyao;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1138-1146
    • /
    • 2018
  • Performance comparisons of switched reluctance motor for cooling fan application are dealt in this paper. Conventional and novel segmental type motors with the same dimension are compared. The conventional 12/8 type is very popular and used widely. The structure of segmental rotor type motor is constructed from a series of discrete segments, and the stator is constructed from two types of stator poles: exciting and auxiliary poles. This type of motor has short flux path and no flux reversal in the stator. The auxiliary poles are not wound by the windings and only provide the flux return path. Compared with conventional SRM, the segmental structure increases electrical utilization of the machine and decreases core losses, which leads to higher efficiency. To verify the segmental structure, finite element method (FEM) is employed to get static and dynamic characteristics of both SRMs. Finally, the prototypes of conventional and segmental SRMs are tested for characteristics comparisons.