• 제목/요약/키워드: fan

검색결과 3,609건 처리시간 0.031초

축류형 송풍기의 성능 및 소음 예측을 위한 전산 프로그램의 개발 및 적용 (Development and Application of the Computer Program for the Performance and Noise Prediction of Axial Flow Fan)

  • 정동규;홍순성;이찬
    • 한국유체기계학회 논문집
    • /
    • 제3권3호
    • /
    • pp.31-40
    • /
    • 2000
  • A computer program is developed for the prediction of the aerodynamic performance and the noise characteristics in the basic design step of axial flow fan. The flow field and the performance of fan are analyzed by using the streamline curvature computing scheme with total pressure loss and flow deviation models. Fan noise is assumed to be generated due to the pressure fluctuations induced by wake vortices of fan blades and to radiate via dipole distribution. The vortex-induced fluctuating pressure on blade surface is calculated by combining thin airfoil theory and the predicted flow field data. The predicted performances, sound pressure level and noise directivity patterns of fan by the present method are favorably compared with the test data of actual fan. Furthermore, the present method is shown to be very useful in optimizing design variables of fan with high efficiency and low noise level.

  • PDF

차량용 MR 팬 클러치 설계 및 제어 (Design and Control of MR Fan Clutch for Automotive Application)

  • 김은석;손정우;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.633-638
    • /
    • 2009
  • This paper presents an optimal design of a magnetorheological(MR) fan clutch based on finite element analysis and also presents torque control of engine cooling fan using a sliding mode control. The MR fan clutch is constrained in a specific volume and the optimization problem identifies the geometric dimension of the fan clutch that minimizes an objective function. The objective function for the optimization problem is determined based on the solution of the magnetic circuit of the initially designed clutch. Under consideration of spatial limitation, design parameters are optimally determined using finite element analysis. After describing the configuration of the MR fan clutch, the viscous torque and controllable torque are obtained on the basis of the Bingham model of MR fluid. Then, a sliding mode controller is designed to control the torque of the fan clutch according to engine room temperature and control performance is evaluated through computer simulation.

  • PDF

Behavior of Rotating Stall Cell in a High Specific-Speed Diagonal Flow Fan

  • Shiomi, Norimasa;Cai, W.X.;Muraoka, A.;Kaneko, K.;Setoguchi, T.
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1860-1868
    • /
    • 2001
  • An experimental investigation was carried out to clarify unsteady flow fields with rotating stall cell, especially behavior of stall cell, in a high specific-speed diagonal flow fan. As its specific-speed is vary high for a diagonal flow fan, its pressure-flow rate curve tends to indicate unstable characteristics caused by rotating stall similar to axial flow fan. Although for an axial flow fan many researchers have investigated such the flow field, for a diagonal flow fan tittle study has been done. In this study, velocity fields at rotor Inlet in a high specific-speed diagonal flow fan were measured by use of a single slant hot-wire probe. These data were processed by using the "Double Phase-Locked Averaging"(DPLA) technique, i. e. phases of both the rotor blade and the stall cell were taken into account. The behaviors of stall cell at rotor inlet were visualized for the meridional, tangential and radial velocity.

  • PDF

에어컨 용 횡단류 홴의 특정 주파수 소음 성분의 저감 대책에 관한 연구 -날개의 랜덤 배열과 경사진 스태빌라이저에 대한 연구- (A Study on the Reduction of Discrete Frequency Tones of a Cross-Flow Fan of Air-Conditioners -Studies on the Random Distribution of Fan Blades and the Skewed Stabilizers-)

  • 구형모
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.870-878
    • /
    • 1998
  • The cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll casing is widely used in many air-ventilating and air-conditioning devices. Its ooperating points of high efficiency and loading conditions frequently induce a annoying sharp tonal component of discrete frequency on the noise spectrum, which is open called as a BPF(Blade-Passing-Frequency) noise and degrades the sound quality of the devices. this BPF tone has been one of the defects of the cross-flow fan. This study proposes two methods in order to reduce this tonal noise component, which are the random distributions of the fan blades and the skewed shapes of the stabilizer. The proposed methods are verified by a simple analytical model and are applied in manufacturing the cross-flow fan and the stabilizer samples. Some experiments are carried out to verify the reduction capability of BPF tones of above two schemes and the experimental results are analyzed. The comparison between two method is also carried out.

  • PDF

여름철 환경에서 팬이 있는 조끼의 인체 착용 효과 (Analysis of the Effects of Vests with Fan in Summer Environments)

  • 엄란이;이예진
    • 한국의류학회지
    • /
    • 제43권6호
    • /
    • pp.856-865
    • /
    • 2019
  • This study analyzed the effect of wearing a vest with an attached electric fan. Korean men in their 20s were given test "fan vests" equipped with fans on the chest, stomach, upper back, or lower back to wear. Participants wore them in a climate chamber set to replicate a summer environment (30±3℃, 75±1%RH, 0.2 m/sec). Subjective sensations and surface temperatures were measured. The attached fan on the front of the vest lowered the temperature of the vest and the skin surface where the fan was positioned, regardless of whether the wearer engaged in exercise. However, a fan attached to the lower back of the vest was effective in lowering the lower back of the vest as well as the upper back, back of the arm, and back of the neck. In addition, subjective evaluations indicated that a vest with fans attached to the stomach and lower back provided a cool sensation. However, it was confirmed that the design of an auxiliary tool capable of dispersing the weight is necessary since the weight of the fans can interfere with the comfort of wearing the vest.

분배계통에 따른 지하주차장 환기설비 성능의 예측

  • 김경환;이재헌;오명도;김종필
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.982-992
    • /
    • 2001
  • In this paper, the performance of ventilation equipments in enclosed parking garages were investigated for several air distribution systems by numerical method. Air change effectiveness of the non-mixing system was 0.42. It meant that more supply air as much as the design supply air was needed to maintain good indoor air quality. In the high speed nozzle ventilating system which is most expensive one, air change effectiveness was 0.54. Therefore this system satisfied to ventilation design. In the jet fan ventilating systems, air change effectiveness for jet fan ventilating system-A with 18 jet fans and jet fan ventilating system-B with 6 jet fans in circulation mixing arrangement were 0.565 and 0.42 respectively. Jet fan ventilating system-C with 6 jet fans in transport mixing arrangement was 0.535. Jet fan ventilating system-A and jet fan ventilating system-C met the ventilation design. But velocity in jet fan ventilating system-A was over 2.0m/s which is inappropriate in human comfort. Therefore this system is not proper to ventilation. Jet fan ventilating system-C was the optimum one for enclosed parking garages among 5 systems examined in this paper.

  • PDF

프로펠러 팬과 덕트와의 상대위치가 유동특성에 미치는 영향 (The effect of position of propeller fan relative to duct inlet on flow characteristics)

  • 심우찬;조강래;주원구
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.14-22
    • /
    • 1997
  • The position of propeller fan from duct inlet is one of basic parameters for the design of propeller fan. To investigate the effect of its position on fan characteristics, the inlet flow fields and relative flow angles were measured by a 5-hole pitot tube. The experimental results indicate that the ratio of radial flow introduced from propeller circumference to total inlet flow increases with the increase of propeller distance from duct inlet. When fan operates without duct, the total flow rate and the radial flow ratio are higher than those of any other positions of propeller relative to duct inlet. The radial flow ratio decreases as a flow coefficient and the propeller distance decrease. Therefore the front flow fields can be adjusted in some extent by varying the propeller distance according to a fan loading. The inlet flow angles are decreasing a little as a rotational speed and the propeller distance decrease. In the present case it was judged that the deviation angle of outlet flow became negative owing to a flow separation near a trailing edge.

  • PDF

밀폐공간 내에서 압전세라믹 냉각홴의 열성능에 대한 실험적 연구 (Experimental Study on the Thermal Performance of Piezoelectric Fan in an Enclosure)

  • 박상희;최문철
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1173-1180
    • /
    • 2006
  • This study deals with fluid flow and heat transfer around a module cooled by forced air flow generated by a piezoelectric(PZT) fan in an enclosure. The fluid flows were generated by a flexible PZT fan which deflects inside a fluid transport system of comparatively simple structure mounted on a PCB in an enclosure($270\times260\times90mm^3$). Input voltages of 30V and 40V, and a resonance frequency of 28Hz were used to vibrate the cooling fan. Input power to the module was 4W. The height in an enclosure was changed 23$\sim$43mm. The fluid flow around the module was visualized by using PIV system. The temperature distributions around a heated module were visualized by using liquid crystal film. As the height in an enclosure and the input voltage of PZT fan increased, the cooling effect of module using a PZT fan increased. We found that the flow type was T- or Y-shape and the cooling effect was increased by the wake generated by a PZT fan.

선풍기의 운전 상황별 발열특성 및 전류신호 검출 (Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations)

  • 김두현;이흥수
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.

조합논리회로의 다중결함검출 (Multiple Fault Detection in Combinational Logic Networks)

  • 고경식;김흥수
    • 대한전자공학회논문지
    • /
    • 제12권4호
    • /
    • pp.21-27
    • /
    • 1975
  • 본 논문에서는 분기가 있는 일반조합논리회로의 다중결함을 검출할 수 있는 테스트집합을 구하는 절차를 유도하였다. 일반논리회로를 우선 내부분기점을 전후하여 이를 분기가 없는 부분회로로 분리하고 각 부분회로에 대한 최소테스트집합을 구한다. 다음에 각 부분테스트를 최대한으로 병립시켜 합성테스트를 구하여 종합적인 일차입력벡터를 정한다. 이러날 수 있는 모든 결함을 빠짐없이 피복할 수 있는 최소테스트집합을 구해가는 과정에 대해서는 각 를 들어 상세히 설명하였다. In this paper, a procedure for deriving of multiple fault detection test sets is presented for fan-out reconvergent combinational logic networks. A fan-out network is decomposed into a set of fan-out free subnetworks by breaking the internal fan-out points, and the minimal detecting test sets for each subnetwork are found separately. And then, the compatible tests amonng each test set are combined maximally into composite tests to generate primary input binary vectors. The technique for generating minimal test experiments which cover all the possible faults is illustrated in detail by examples.

  • PDF