A Discovery of the Creative Healing Properties in the Unconscious of Alcoholics: From the Perspective of Analytical Psychology (알코올 중독에서 발견되는 무의식의 창조적 치유 활동: 분석심리학의 관점에서)

  • Kihong Baek
    • Sim-seong Yeon-gu
    • /
    • v.39 no.1
    • /
    • pp.129-183
    • /
    • 2024
  • This study is an attempt to get closer to the psychological truth of alcohol addiction. After reviewing previous related studies, the experiences of Korean alcoholics were examined, encompassing both the conscious and unconscious aspects. In order to approach the unconscious, the researcher paid attention to the series of dreams that the patients reported, from the perspective of Jungian dream analysis. Working with dreams brought considerable benefits in increasing patient's involvement in the therapeutic process and fostering therapist-patient alliance. It also helped to understand patients' conscious and unconscious aspects further. The results were as follows. On the conscious level, patients showed a long-standing alienation from their true emotional needs, a lack of sufficient experience in genuinely expressing and being accepted with one's own emotion, resulting in the need for emotional re-experience, along with the intense longing for maternal affection. This also meant that they were in need for maternal re-experience, and at the same time, for the associated paternal re-experience. Furthermore, the researcher identified that certain powerful archetypal complexes had been activated in the patient's unconscious in response to their conscious situations, triggering the destructive shadows to emerge and exert a strong influence on their conscious lives. The series of reported dreams shows how the unconscious always properly and diligently compensates, modifying the perspective and attitude of the conscious and gradually opening the doors to healing, even for alcoholic patients. This indicates that the unconscious carries out a specific and consistent guidance role so the conscious can realize and adequately respond to it, and that it also provides the creative force for transforming the conscious life. These findings suggest that alcohol addiction is a psychological condition that can jeopardize one's life by allowing the powerful energy of the unconscious to penetrate the conscious, but at the same time, have the purpose and direction to urge the creative transformation of one's conscious life. From these results, it can be concluded that the first step towards true recovery is for the individual to turn their attention towards the psychological truth occurring within themselves. In this regard, the therapist's role is crucial. This also suggests that various attempts in the field of addiction treatment will blossom their real values when they contribute, directly or indirectly, to the development of one's self-awareness since as long as one continues to turn away from the psychological truth and persist in craving for false objects, their creative healing properties in the unconscious could rather have negative and destructive impacts on their life.

Usefulness of LIFE in diagnosis of bronchogenic carcinoma (기관지 암의 진단에서 형광기관지 내시경검사의 유용성)

  • Lee, Sang Hwa;Shim, Jae Jeong;Lee, So Ra;Lee, Sang Youb;Suh, Jung Kyung;Cho, Jae Yun;Kim, Han Gyum;In, Kwang Ho;Choi, Young Ho;Kim, Hark Jei;Yoo, Se Hwa;Kang, Kyung Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.69-84
    • /
    • 1997
  • Background : Although the overall prognosis of patients with lung cancer is poor, highly effective treatment exists for the small subset of patients with early lung cancer(carcinoma in situ/micro- invasive cancer). But very few patients have benefit from them because these lesions are difficult to detect and localize with conventional white-light bronchoscopy. To overcome this problem, a Lung Imaging Fluorescence Endoscopic device(LIFE) was developed to detect and clearly delineate the exact location and extent of premalignant and early lung cancer lesions using differences in tissue autofluorescence. Purpose : The purpose of this study was to determine the difference of sensitivity and specificity in detecting dysplasia and carcinoma between fluorescence imaging and conventional white light bronchoscopy. Material and Methods : 35 patients (16 with abnormal chest X-ray, 2 with positive sputum study, 2 with undiagnosed pleural effusion, 15 with respiratory symptom) have been examined by LIFE imaging system. After a white light bronchoscopy, the patients were submitted to fluorescence bronchoscopy and the findings of both examinations have been classified in 3 categories(class I, II, III). From of all class n and III sites, 79 biopsy specimens have been collected for histologic examination: a comparison between histologic results and white light or fluorescence bronchoscopy has been performed for assessing sensitivity and specificity of the two methods. Results : 1) Total 79 sires in 35 patients were examined. Histology demonstrated 8 normal mucosa, 21 hyperplasia, 23 dysplasia, and 27 microinvasive and invasive carcinoma. 2) The sensitivity of white light or fluorescence bronchoscopy in detecting dysplasia was 60.9% and 82.6%, respectively. 3) The results of this study showed 70.3 % sensitivity for microinvasive or invasive carcinoma with LIFE system, versus 100% sensitivity for white light in 27 cases of carcinoma. The false negative study of LIFE system was 8 cases(3 adenocarcinoma and 5 small cell carcinoma), which were infiltrated in submucosal area and had normal epithelium. Conclusion : To improve the ability 10 diagnose and stage more accurately, fluorescence imaging may become an important adjunct to conventional bronchoscopic examination because of its high detection rate of premalignant and malignant epithelial lesion. But. it has limitation to detect in submucosal infiltrating carcinoma.

  • PDF

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF