• Title/Summary/Keyword: false positive

Search Result 876, Processing Time 0.023 seconds

Colonic Uptake Patterns of F-18-FDG PET in Asymptomatic Adults: Comparison with Colonoscopic Findings (무증상 성인의 F-18-FDG PET 대장 섭취양상 : 대장내시경 소견과의 비교)

  • Pai, Moon-Sun;Cho, Yoo-Kyung;Jung, Sung-Ae;Shim, Ki-Nam;Lee, Hong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.15-20
    • /
    • 2005
  • Purpose: Physiologic intestinal FDG uptake is frequently observed in asymptomatic individuals for cancer screening FDG PET Colonic FDG accumulation is a well-known confusing findings that interfere true cancer detection or cause false positive. The aim of this study was to evaluate the pattern and intensity of colonic uptake in whole body FDG PET in asymptomatic healthy adults and to correlate them with colonoscopic findings. Materials and Methods: We reviewed retrospectively 64 subjects (age: 27-87, M:F=31:33) who underwent both FDG PET and colonoscopy for cancer screening. FDG uptake patterns were classified as focal, segmental and diffuse. Maximum SUV were measured. The PET results were compared with colonoscopic and histologic findings. Results: In 13 patients FDG bowel uptake was interpreted as focal, in 17 patients as segmental and in 34 patients as diffuse uptake. Six adenomas (17.6%, average diameter=5.0 mm) were found in diffuse pattern, 7 adenomas (41.1%, 5.6 mm) in segmental and 4 adenomas and 1 adenocarcinoma (38.5%, 16.4 mm) in focal uptake pattern. In patients with focal uptake, four were non-adenomatous pathologic lesions (30.8%, 2 intestinal tuberculosis, 2 mucosal ulcer). There is no difference of mean SUV between patients with adenoma and with negative colonoscopic results in each group of intestinal FDG pattern (Diffuse: $1.7{\pm}0.1\;vs.\;1.9{\pm}0.5$, Segmental: $4.8{\pm}3.6\;vs.\;4.2{\pm}1.2$, Focal: $6.5{\pm}4.7\;vs.\;3.5{\pm}1.3$). large adenomas (>1 cm) can be detected more in the focal uptake pattern (4 out of 5) rather than in segmental (1 out of 7) or diffuse uptake (none) and had higher SUV ($6.3{\pm}4.8$) than small adenomas ($3.5{\pm}3.0$) (statistically insignificant). Conclusion: focal FDG uptake is associated more often with large adenoma and other pathologic findings in colonoscopy. Segmental uptake cannot discriminate presence of adenoma from negative results, while diffuse pattern may have more chance to be normal.

Comparative study of flood detection methodologies using Sentinel-1 satellite imagery (Sentinel-1 위성 영상을 활용한 침수 탐지 기법 방법론 비교 연구)

  • Lee, Sungwoo;Kim, Wanyub;Lee, Seulchan;Jeong, Hagyu;Park, Jongsoo;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.3
    • /
    • pp.181-193
    • /
    • 2024
  • The increasing atmospheric imbalance caused by climate change leads to an elevation in precipitation, resulting in a heightened frequency of flooding. Consequently, there is a growing need for technology to detect and monitor these occurrences, especially as the frequency of flooding events rises. To minimize flood damage, continuous monitoring is essential, and flood areas can be detected by the Synthetic Aperture Radar (SAR) imagery, which is not affected by climate conditions. The observed data undergoes a preprocessing step, utilizing a median filter to reduce noise. Classification techniques were employed to classify water bodies and non-water bodies, with the aim of evaluating the effectiveness of each method in flood detection. In this study, the Otsu method and Support Vector Machine (SVM) technique were utilized for the classification of water bodies and non-water bodies. The overall performance of the models was assessed using a Confusion Matrix. The suitability of flood detection was evaluated by comparing the Otsu method, an optimal threshold-based classifier, with SVM, a machine learning technique that minimizes misclassifications through training. The Otsu method demonstrated suitability in delineating boundaries between water and non-water bodies but exhibited a higher rate of misclassifications due to the influence of mixed substances. Conversely, the use of SVM resulted in a lower false positive rate and proved less sensitive to mixed substances. Consequently, SVM exhibited higher accuracy under conditions excluding flooding. While the Otsu method showed slightly higher accuracy in flood conditions compared to SVM, the difference in accuracy was less than 5% (Otsu: 0.93, SVM: 0.90). However, in pre-flooding and post-flooding conditions, the accuracy difference was more than 15%, indicating that SVM is more suitable for water body and flood detection (Otsu: 0.77, SVM: 0.92). Based on the findings of this study, it is anticipated that more accurate detection of water bodies and floods could contribute to minimizing flood-related damages and losses.

Usefulness of LIFE in diagnosis of bronchogenic carcinoma (기관지 암의 진단에서 형광기관지 내시경검사의 유용성)

  • Lee, Sang Hwa;Shim, Jae Jeong;Lee, So Ra;Lee, Sang Youb;Suh, Jung Kyung;Cho, Jae Yun;Kim, Han Gyum;In, Kwang Ho;Choi, Young Ho;Kim, Hark Jei;Yoo, Se Hwa;Kang, Kyung Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.69-84
    • /
    • 1997
  • Background : Although the overall prognosis of patients with lung cancer is poor, highly effective treatment exists for the small subset of patients with early lung cancer(carcinoma in situ/micro- invasive cancer). But very few patients have benefit from them because these lesions are difficult to detect and localize with conventional white-light bronchoscopy. To overcome this problem, a Lung Imaging Fluorescence Endoscopic device(LIFE) was developed to detect and clearly delineate the exact location and extent of premalignant and early lung cancer lesions using differences in tissue autofluorescence. Purpose : The purpose of this study was to determine the difference of sensitivity and specificity in detecting dysplasia and carcinoma between fluorescence imaging and conventional white light bronchoscopy. Material and Methods : 35 patients (16 with abnormal chest X-ray, 2 with positive sputum study, 2 with undiagnosed pleural effusion, 15 with respiratory symptom) have been examined by LIFE imaging system. After a white light bronchoscopy, the patients were submitted to fluorescence bronchoscopy and the findings of both examinations have been classified in 3 categories(class I, II, III). From of all class n and III sites, 79 biopsy specimens have been collected for histologic examination: a comparison between histologic results and white light or fluorescence bronchoscopy has been performed for assessing sensitivity and specificity of the two methods. Results : 1) Total 79 sires in 35 patients were examined. Histology demonstrated 8 normal mucosa, 21 hyperplasia, 23 dysplasia, and 27 microinvasive and invasive carcinoma. 2) The sensitivity of white light or fluorescence bronchoscopy in detecting dysplasia was 60.9% and 82.6%, respectively. 3) The results of this study showed 70.3 % sensitivity for microinvasive or invasive carcinoma with LIFE system, versus 100% sensitivity for white light in 27 cases of carcinoma. The false negative study of LIFE system was 8 cases(3 adenocarcinoma and 5 small cell carcinoma), which were infiltrated in submucosal area and had normal epithelium. Conclusion : To improve the ability 10 diagnose and stage more accurately, fluorescence imaging may become an important adjunct to conventional bronchoscopic examination because of its high detection rate of premalignant and malignant epithelial lesion. But. it has limitation to detect in submucosal infiltrating carcinoma.

  • PDF

F-18 FDG PET Scan findings in Patients with Pulmonary Involvement in the Hypereosinophilic Syndrome (원발성 과호산구증가 증후군 환자들 중 폐침범을 보이는 환자군의 F-18 FDG PET 소견)

  • Lee, Jae-Hoon;Kim, Tae-Hoon;Yun, Mi-Jin;Hur, Jin;Kim, Tae-Sung;Kim, Sang-Jin;Kim, Hyung-Joong;Pai, Moon-Sun;Ryu, Young-Hoon;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.239-245
    • /
    • 2005
  • Purpose: Hypereosinophilic syndrome (HES) is an infiltrative disease of eosinophils affecting multiple organs including the iung. F-18 2-fluoro-2-deoxyglucose (F-18 FDG) may accumulate at sites of inflammation or injection, making interpretation of whole body PET scan difficult in patients with cancer. This study was to evaluate the PET findings of HES with lung involvement and to find out differential PET features between lung malignancy and HES with lung involvement. Material and Methods: F-18 FDG PET and low dose chest CT scan was performed for screening of lung cancer. light patients who showed ground-glass attenuation (GGA) and consolidation on chest CT scan with peripheral blood eosinophilia werr included in this study. The patients with history of parasite infection, allergy and collagen vascular disease were excluded. CT features and FDG PET findings were meticulously evaluated for the distribution of GGA and consolidation and nodules on CT scan and mean and maximal SUV of abnormalities depicted on F-18 FDG PET scan. In eight patients, follow-up chest CT scan and FDG PET scan were done one or two weeks after initial study. Results: F-18 FDG PET scan identified metabolically active lesions in seven out of eight patients. Maximal SUV was ranged from 2.8 to 10.6 and mean SUV was ranged from 2.2 to 7.2. Remaining one patient had maximal SUV of 1.3. On follow-up FDG PET scan taken on from one to four weeks later showed decreased degree of initially noted FDG uptakes or migration of previously noted abnormal FDG uptakes. Conclusions: Lung involvement in the HES might be identified as abnormal uptake foci on FDG PET scan mimicking lung cancer. Follow-up FDG PET and CT scan for the identification of migration or resolution of abnormalities and decrement of SUV would be of help for the differentiation between lung cancer and HES with lung involvement.

Diagnostic Efficacy of FDG-PET Imaging in Solitary Pulmonary Nodule (고립성폐결절의 진단시 FDG-PET의 임상적 유용성에 관한 연구)

  • Cheon, Eun Mee;Kim, Byung-Tae;Kwon, O. Jung;Kim, Hojoong;Chung, Man Pyo;Rhee, Chong H.;Han, Yong Chol;Lee, Kyung Soo;Shim, Young Mog;Kim, Jhingook;Han, Jungho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.882-893
    • /
    • 1996
  • Background : Over one-third of solitary pulmonary nodules are malignant, but most malignant SPNs are in the early stages at diagnosis and can be cured by surgical removal. Therefore, early diagnosis of malignant SPN is essential for the lifesaving of the patient. The incidence of pulmonary tuberculosis in Korea is somewhat higher than those of other countries and a large number of SPNs are found to be tuberculoma. Most primary physicians tend to regard newly detected solitary pulmonary nodule as tuberculoma with only noninvasive imaging such as CT and they prefer clinical observation if the findings suggest benignancy without further invasive procedures. Many kinds of noninvasive procedures for confirmatory diagnosis have been introduced to differentiate malignant SPNs from benign ones, but none of them has been satisfactory. FOG-PET is a unique tool for imaging and quantifying the status of glucose metabolism. On the basis that glucose metabolism is increased in the malignant transfomled cells compared with normal cells, FDG-PET is considered to be the satisfactory noninvasive procedure which can differentiate malignant SPNs from benign SPNs. So we performed FOG-PET in patients with solitary pulmonary nodule and evaluated the diagnostic accuracy in the diagnosis of malignant SPNs. Method : 34 patients with a solitary pulmonary nodule less than 6 cm of irs diameter who visited Samsung Medical Center from Semptember, 1994 to Semptember, 1995 were evaluated prospectively. Simple chest roentgenography, chest computer tomography, FOG-PET scan were performed for all patients. The results of FOG-PET were evaluated comparing with the results of final diagnosis confirmed by sputum study, PCNA, fiberoptic bronchoscopy, or thoracotomy. Results : (I) There was no significant difference in nodule size between malignant (3.1 1.5cm) and benign nodule(2.81.0cm)(p>0.05). (2) Peal SUV(standardized uptake value) of malignant nodules (6.93.7) was significantly higher than peak SUV of benign nodules(2.71.7) and time-activity curves showed continuous increase in malignant nodules. (3) Three false negative cases were found among eighteen malignant nodule by the FDG-PET imaging study and all three cases were nonmucinous bronchioloalveolar carcinoma less than 2 em diameter. (4) FOG-PET imaging resulted in 83% sensitivity, 100% specificity, 100% positive predictive value and 84% negative predictive value. Conclusion: FOG-PET imaging is a new noninvasive diagnostic method of solitary pulmonary nodule thai has a high accuracy of differential diagnosis between malignant and benign nodule. FDG-PET imaging could be used for the differential diagnosis of SPN which is not properly diagnosed with conventional methods before thoracotomy. Considering the high accuracy of FDG-PET imaging, this procedure may play an important role in making the dicision to perform thoracotomy in diffcult cases.

  • PDF

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF