• Title/Summary/Keyword: falling number

Search Result 281, Processing Time 0.03 seconds

Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (2nd. Report, Characteristics of Heat Transfer) (수직관내(垂直管內)를 흘러내리는 액막식(液膜式) 흡수기(吸收器)의 흡수(吸收) 및 열전달특성(熱傳達特性)(제(第)2보(報) 열전달특성(熱傳達特性)))

  • Ohm, K.C.;Rie, D.H.;Choi, G.G.;Kasiwagi, Takao;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.257-264
    • /
    • 1993
  • This is the second report of a three part study on the absorption and heat transfer characteristics of absorber, the correlation of refrigerating capacity and heating capacity. The 2nd report deals with the heat transfer characteristics of a vertical falling film type absorber of inner copper tube. The solute is LiBr-Water solution(60wt%) and the solvent is water vapor. The film Reynoles numbers are varied in the range of 35~130. The states of LiBr solution at the top of absorber are supercooled liquid and superheated liquid. The results are summarized as follows ; Heat transfer results reveal that for the absorption of falling film, the state of LiBr solution appears to be influential in determining the heat transfer. Thus, for the state of supercooled liquid, heat transfer coefficient decreases with increasing the film Reynolds number, but in the condition of superheated liquid, it increases conversely. The mass transfer coefficients that were presented in the 1st.report and heat transfer coefficients of this paper are presented as the dimensionless correlation. The optimum water flowrate which brings about maximum value of heat flux in the film exists, and that increases with increasing the cooling water temperature.

  • PDF

Effects of Non-Absorbable Gases on the Absorption Process of Aqueous LiBr Solution Film in a Vertical Tube (I) (수직관내 리튬브로마이드 수용액막의 흡수과정에 대한 비흡수가스의 영향)

  • Kim, Byeong-Ju;Lee, Chan-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.489-498
    • /
    • 1998
  • Among the heat/mass exchange units composing an absorption system, the absorber, where the refrigerant vapor is absorbed into the liquid solution is the one least understood. In the present study, the effects of non-absorbable gas on the absorption process of aqueous lithium bromide solution falling film inside a vertical tube were experimentally investigated. In the range of film Reynolds number of 30 ~ 195, heat and mass transfer characteristics were investigated as a function of non-absorbable gas volumetric concentration, 0.2 ~ 20%. An increase of non-absorbable gas volumetric concentration degraded the mass transfer rate dramatically in the absorption process. The reduction of mass transfer rate was significant for the addition of small amount of non-absorbable gas to the pure vapor. At film Reynolds number of 130, an increase of non-absorbable gas concentration from 0.2 to 6.0% resulted in the decrease of mass transfer rate by 36% and 20% of non-absorbable gas by 59%. However the decrease of film Nusselt number with the increase of volumetric concentration of non absorbable gas was relatively smaller than the decrease of Sherwood number. Critical film Reynolds number was identified to exist for the maximum heat and mass transfer regardless of the volumetric concentration of non-absorbable gases.

Approximate solutions on the absorption process of an aqueous LiBr falling film : effects of vapor flow (리튬브로마이드 수용액 유하액막의 흡수과정에 대한 근사 해법 : 증기 유동의 영향)

  • Kim, B.J.;Lee, C.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.144-152
    • /
    • 1997
  • Film absorption involves simultaneous heat and mass transfer in the vapor-liquid system. In the present work, the absorption process of water vapor by an aqueous soluton of LiBr flowing inside of the vertical tube was investigated. The continuity, momentum, energy and diffusion equations for the solution film and vapor were formulated in integral forms and solved numerically. The model could predict the film thickness, the pressure gradient, and the heat and mass transfer rate. Particularly the effects of vapor flow conditions on the absorption process were investigated in terms of the vapor Reynolds number. As the vapor Reynolds number increased, the shear stress at the vapor-solution interface also increased. Consequently solution film became thinner at higher vapor flowrate under the co-currentflow condition. Thinner film was capable of higher heat transfer to the wall and leaded to higher absorption rate of the water vapor into the solution film.

  • PDF

Investigation & Analysis about fatalities of falls from height at construction work (건설현장(建設現場) 추락(墜落) 사망재해(死亡災害) 원인(原因) 조사(調査) 분석(分析))

  • Ko, Young-Wook;Kim, Dong-Ryeong;Cho, Joung-Ho;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.49-57
    • /
    • 2012
  • Proportion of falling from height accident at construction work accounts for more than 40%, and the number of injuries is getting increased. So without considering falling from height, we can say that it's hard to achieve our goal(accident prevention). Another critical point that we have to think about theses days is the fact that construction workers are getting older. To be specific, the number of workers who are above 50 years old accounts for 65.6% among the fatalities(2007~2011, KOSHA inspection). Accordingly, to effectively prevent construction accedents, especially falls from height, we need to focus on motion analysis of older construction workers and then make suitable measures for growing accident rates at construction work.

3D Numerical Study of Horizontal Falling Film Evaporator in Multi Effect Distillation (MED) Plant (MED 담수기내 수평관 강하막식 증발기의 3D 수치해석적 연구)

  • Kim, Soo Jae;Je, Junho;Kim, Moo Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.513-522
    • /
    • 2013
  • In the present work, a numerical study of a horizontal falling film evaporator in a multi-effect distillation (MED) plant is performed. Tube bundles in the evaporator are described as porous media, and a volume-averaged method is applied. To calculate the fluid flow and phase change in the evaporator due to heat transfer in the system, FLUENT and user-defined functions (UDF) are used. To observe the performance of the evaporator under different operational conditions, tests are conducted for a steam mass flux ranging from 0.5 to 2.5 $kg/m^2s$ in the horizontal tube, for mass fraction of the noncondensable gas in the tube inlet ranging from 0% to 1%, and for film Reynolds numbers ranging from 100 to 1,000 for the falling film. The evaporation rate increases with the steam mass flux and Reynolds number. In contrast, the evaporation rate decreases by 0.87% with a 1% increase in the mass fraction of the noncondensable gas in the tube.

Experience of Falls and Predictors of Falls in the Elderly at Senior Citizens' Centers (경로당 이용 노인의 낙상경험과 낙상 예측요인)

  • Yoo, In-Young;Choi, Jung-Hyun
    • Research in Community and Public Health Nursing
    • /
    • v.18 no.1
    • /
    • pp.14-22
    • /
    • 2007
  • Purpose: The purpose of this study was to investigate the experience of falls, the fear of falling and fall efficacy and identify the predictors of falls in the elderly at senior citizens' centers. Method: The subjects of this study were 106 elders who used senior citizens' centers in Chungcheongbuk-do, Korea. Data were collected from May to June, 2006 through a survey using a structured questionnaire. Result: Of the elderly sampled, 35.8% experienced falls during the last 1 year. Of falls experienced by the elderly, 53% occurred indoors, 47% outdoors, 15.8% in the bathroom or toilet. In addition, 57.8% of the elderly had injuries on the hip and waist related with falls. The fear of falling was higher in those with experience in falls than in those without. Factors affecting the elders' falls were age (OR=1.113, 95% CI=1.012-1.224), the number of chronic disease (OR=2.342, 95% CI=1.365-4.019) and the fear of falling (OR=4.279, 95% CI=1.901-9.634). The predictor of the frequency of falls was fall efficacy ($R^2=24.9$). Conclusion: As a result, it is essential to develop fall prevention programs based on the fear of falling, fall efficacy, chronic diseases and medication state. And in senior citizens' centers, fall prevention safety education should be activated as a health promotion program.

  • PDF

The Reapperarance of Relative Density by the Multiple Sieving Pluviation Method (다중체 낙하법에 의한 상대밀도 재현에 관한 연구)

  • 주재우;곽정민
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.09a
    • /
    • pp.265-272
    • /
    • 1994
  • The relative density seems to be important as a factor of controlling the physical properties in the case of cohesionless soil ground as sand. Therefore, the study is more important about the method for reappearing the same relative density when the specimen of shearing test is to be produced or the model test of ground is to be made. In this study, the apparatus making use of the multiple sieving pluviation method - one of the reappearance of relative density - could be made. Using this apparatus, tests were practiced varying the factors such as the size of sieve mesh and the number of sieve, the amount of falling discharge, the falling height etc. about the standard sand in Jumunjin and Hadong sand. When laboratory test is performed by the cohensionless soil , it presents the method for reappearing of the relative density in field.

  • PDF

A Numerical Study on Heat and Mass Transfer in a Falling Film of Vertical Plate Absorber Cooled by Air (공랭형 수직평판 흡수기 액막에서의 열 및 물질전달에 관한 수치적 연구)

  • 김선창;오명도;이재헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.4
    • /
    • pp.1071-1082
    • /
    • 1995
  • Numerical analyses have been performed to obtain the absorption heat and mass transfer coefficients and the absorption mass flux from a falling film of the LiBr aqueous solution which is cooled by cooling air. Heat flux at the wall is specified in terms of the heat transfer coefficient of cooling air and the cooling air temperature. Effects of operating conditions, such as the heat transfer coefficient, the cooling air temperature, the system pressure and the solution inlet concentration have been investigated in view of the local absorption mass flux and the total mass transfer rate. Effects of film thickness and film Reynolds number on the heat and mass transfer coefficients have been also estimated. Analyses for the constant wall temperature condition have been also carried out to examine the reliability of present numerical method by comparing with previous investigations.

Evaporation of Water in an Aqueous Lithium Bromide Solution flowing over a Horizontal Tube

  • Kim, Dong-Kwan;Kim, Moo-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.57-62
    • /
    • 2001
  • Falling film heat transfer analyses with aqueous lithium bromide solution were performed to investigate the transfer characteristics of the copper tubes. Finned (knurled) tube and a smooth tube were selected as test specimens. Averaged generation fluxes of water and the heat flux were obtained. As the film flow rate of the solution increased, the generation fluxes of water decreased for both tubes due to the fact that the heat transfer resistance increased with the film thickness. The effect of the enlarged surface area at the knurled tube was supposed to be dominant at a small flow rate. The generation fluxes of water increased with the increasing degree of tube wall superheat. Nucleate boiling is supposed to occur at a wall superheat of 20K for a smooth tube, and at 10K for a knurled tube. The increased performance of the knurled tube was supposed to mainly come from the effect of the increased heating surface area.

  • PDF

A Study on the Characteristics of Yellow Layer Cake Made with Bamboo Leaf Powder (죽엽을 이용한 Yellow Layer Cake의 특성에 관한 연구)

  • Song, Young-Suk;Hwang, Seong-Yun
    • The Korean Journal of Food And Nutrition
    • /
    • v.20 no.2
    • /
    • pp.164-172
    • /
    • 2007
  • The purpose of this study was to investigate the properties of yellow layer cake made with bamboo leaf powder. Physical properties of the medium and cake flour with bamboo leaf powder were tested by falling number, farinogram, alveogram and after making yellow layer cake, which were tested by rheometer and water activity etc. We found that falling numbers increased with addition of bamboo leaf powder and adding bamboo leaf powder to the flour decreased peak viscosity, holding strength, final viscosity etc. The p value of the alveogram increased for the flour containing bamboo leaf powder increased, but development time and stability decreased. The water activity of the yellow layer cakes made with bamboo leaf powder decreased during storage, but they did not show significant differences. The results of the sensory test showed that the 3% of addition of bamboo leaf powder had the best scores.