• 제목/요약/키워드: fall-cone

검색결과 45건 처리시간 0.021초

Fall Cone을 이용한 풍화도 측정(실트질 모래에 대하여) (Estimation of Weathered Degree Using Fall cone in Weathered Soil ; Silty Sand)

  • 손영환;김성필;장병욱
    • 한국농공학회논문집
    • /
    • 제50권1호
    • /
    • pp.61-68
    • /
    • 2008
  • It is essential to analyze and classify the physical characteristics of weathered granite for engineering purposes. This paper is to suggest a physical method to determine the degree of weathering of weathered soils. A new classification method for determining the degree of weathering is suggested, based upon the results from laboratory tests including fall cone test. According to the proposed physical method using fall cone apparatus, the measured values of the samples from the same area show distinctive difference of weathering. The water content tends to increase with increasing the degree of weathering at the same penetration in fall cone test. And relationship between CWI and water content are expressed one equation in Hwaseong area and Ilsan area.

폴콘을 이용한 유류 오염 점토지반의 전단강도 예측 (Prediction of the Shear Strength of Oil Contaminated Clay using Fall Cone)

  • 송영우;이한석;박준범
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권6호
    • /
    • pp.107-113
    • /
    • 2010
  • This paper presents the prediction of shear strength of oil contaminated clay using fall cone test used to determine the liquid limit of soil. The penetration depth of fall cone is related to water content of soil. Laboratory vane shear can also be related to water content. To explore the relative correlation between penetration depth of fall cone and laboratory vane shear, both fall cone tests and laboratory vane shear test were carried out with water contents of soil. The developed empirical relationships in this studys showed that the shear strength is reduced to 3.9% with 1% increase of oil content. And, the lesser initial water content of contaminated clay, the more shear strength of contaminated clay is affected by oil content.

Fall Cone Test의 일점법을 이용한 액성한계 추정 (Estimation of Liquid Limit by a Single-point Method of Fall Cone Test)

  • 손영환;장병욱;원정윤;김성필
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.203-206
    • /
    • 2003
  • The liquid limit(LL) test is universally used as a standard test for determining one of the index properties of a clay. There are two methods of determining the LL, Casagrande method and cone penetration method that is fall cone test. The interpretation of the Casagrande method of obtaining the LL is not obvious, but it has been suggested that the fall cone test is essentially a strength test and that the LL test simply ascertains the moisture content at which a clay has a certain standard undrained shear strength. This paper presents a determination of the LL by a single-point method. Results obtained from fall cone that is general method and a single-point method are analyzed by comparison.

  • PDF

소형콘의 관입저항력을 이용한 점토의 액성한계측정에 관한 연구 (Study on the Measurement of Liquid Limit Using a Penetration Resistance of Small Cone in Clay Soil)

  • 손무락;이재용
    • 한국지반공학회논문집
    • /
    • 제32권10호
    • /
    • pp.5-15
    • /
    • 2016
  • 본 연구에서는 소형콘의 관입저항력을 이용한 점토의 액성한계를 측정하기 위하여 카올리나이트 점토와 벤토나이트 점토의 비율을 다양하게 혼합한 점토흙에 대하여 함수비와 소형콘의 관입저항력을 조사하고 기존의 동적(Casagrande 시험법) 및 정적(Fall cone 시험법) 액성한계 시험결과와 직접 비교하였다. 비교결과 다양한 점토흙의 함수비에 따른 관입저항력 관계곡선에서 변곡점이 형성된다는 것을 파악하였으며 이 때의 함수비가 정적액성한계(Fall cone)시험법에 의한 액성한계 값과 매우 유사함을 파악하였다. 변곡점이 형성된 점에서의 소형콘의 관입저항력은 약 0.2kPa로 나타났으며 이 때 의 함수비가 점토흙의 액성한계를 나타낸다는 것을 확인하였다. 이와 같은 연구결과를 토대로 향후 점토의 액성한계를 파악하는데 본 연구에서 조사된 0.2kPa의 소형콘의 관입저항력이 유용한 지표가 될 수 있다는 사실을 파악하였다. 또한 소형콘의 관입저항력을 이용한 액성한계 시험법을 제시하였다.

Fall cone test의 함수비를 이용한 잔적토의 풍화도 측정 (Estimation of Degree of Weathering in Residual Soil Using Water Content from Fall Cone Test Result)

  • 손영환;장병욱;김성필
    • 한국지반공학회논문집
    • /
    • 제23권12호
    • /
    • pp.13-23
    • /
    • 2007
  • 풍화토는 암석으로부터 풍화되어 그 산물로 나타난다. 또한, 풍화정도에 따라 연암, 풍화암, 잔적토에 이르기까지 그 산물은 다양하다. 일반적으로 풍화정도의 결정은 화학적 방법이나 표준관입시험의 N-value를 이용한다. 그러나 이러한 방법은 약간의 단점을 가지고 있으며, 이에 본 연구에서는 교란시료와 물리적인 방법인 Fall cone test를 이용하여 풍화정도를 결정할 수 있는 방법을 제시하였다. Fall cone test 결과, 동일한 지역에서 풍화정도의 차이를 확인할 수 있었으며, 관입량에 따른 화학적풍화지수(CWI)와 함수비의 관계는 하나의 방정식으로 표현할 수 있었다.

부산점토의 Fall Cone Test에 의한 지수 및 강도특성 (Index Properties and Undrained Shear Strength of the Pusan Clays by Fall Cone Test)

  • 정승원;정성교;;곽정민;김무겸
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.391-398
    • /
    • 2000
  • The index properties of cohesive soils play an important role to examine entire tendency of soil properties. Especially, the Atterberg limits have a good correlation with compression and shear strength of cohesive soils. However, these values strongly depend on their testing methods. In this study, for Pusan clays the Atterberg limits were peformed under different conditions; for example, four kinds of specimen preparation, two kinds of testing equipment, and four kinds of estimating method. And a laboratory vane test was peformed to compare the undrained shear strength with that of the fall cone test. As experimental results, the value of liquid limit performed for oven-dried sample, followed in ASTM D4318, underestimated by about 10% compared to those of another three methods, irrespective to the used equipments. But the value of plastic limit was not influenced by sample preparation methods and equipments. The liquid limits by one-point methods(Leroueil et al., 1996; Nagaraj et al., 1981) were agreed well with those of different methods. Finally, the undrained shear strength by laboratory vane test was relatively larger than that of fall cone test, and the relationship between both showed a bad trend.

  • PDF

함수비를 고려한 모래의 상대밀도 추정을 위한 Fall Cone 관입량의 적용 (Application of Penetration in Fall Cone Test to Estimate Relative Density with Variation of Water Content for Sand)

  • 최우석;손영환;박재성;노수각;봉태호
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.69-77
    • /
    • 2012
  • Relative density, used to express dynamics condition of sand quantitatively, is measured by RI Test, Standard Penetration Test and Cone Penetration Test. Each measurement method has demerits, which is complicated or needs a specific analysis instrument and an analysis of expert. Also the ground is in wet condition commonly because of an unsaturated zone between a saturated zone and a surface, so the behaviour of the ground has different engineering properties unlike the dry ground and it diminishes accuracy of measuring relative density. In this study, the correlation between relative density and penetration of fall cone test in dry condition and wet condition with variation of water content was analyzed and a simple measuring method for relative density was suggested. As a result, there were difference of penetration between dry sands and wet sands, the correlation between relative density and penetration showed linear expression and relative density could be measured by the linear relation.

Fall cone과 수화열을 이용한 흙-시멘트 혼합물의 상 변화 연구 (Phase Changes of Soil-Cement Mixture Using Fall Cone and Heat of Hydration)

  • 김재형;원정윤;김성필;장병욱
    • 한국지반공학회논문집
    • /
    • 제20권9호
    • /
    • pp.25-32
    • /
    • 2004
  • 고함수비 상태의 흙에 시멘트를 첨가하게 되면 흙의 공학적 성질을 개량할 수 있다. 이렇게 고함수비 흙에 시멘트를 혼합하는 경우 흙시멘트 혼합물의 워커빌러티와 밀접한 관련이 있는 상 변화를 예측하고 구분하는 것은 매우 힘들다. 시간에 따른 시멘트 paste의 수화열 변화와 경도의 변화는 흙시멘트 혼합물의 상 변화에 대한 유용한 정보를 제공해준다. 본 연구에서는 시멘트 paste와 흙/시멘트 비를 달리 한 3 종류의 혼합물에 대해 수화열과 콘 관입량을 측정하여 흙시멘트 혼합물의 상 변화를 관찰하였다. 실험결과, 흙시멘트 혼합물의 상 변화는 시멘트 paste와 동일한 형태를 보이며 수화열이 최소가 되는 시점에서 혼합물의 전단강도가 급격하게 증가함을 알 수 있었다. 흙시멘트 혼합물의 초결시점은 fall cone 관입량이 1.0mm, 즉 혼합물이 소성상태에 도달하는 시점과 일치하며 흙/시멘트 비가 증가할수록 초결시간은 지연되었다. 흙시멘트 혼합물에 대한 수화열 측정과 fall cone 관입량 측정은 흙-시멘트 혼합물의 상 변화를 예측하는 유용한 수단으로 사용할 수 있다.

정적 및 동적시험법과 실험자에 따른 점토의 액·소성한계 (Liquid and Plastic Limits of Cohesive Soil by Static and Dynamic Test Methods and Testers)

  • 김찬기;여진수;문영석;박형렬;김태형
    • 한국지반공학회논문집
    • /
    • 제33권3호
    • /
    • pp.5-15
    • /
    • 2017
  • 본 연구는 파주점토에 대해 Casagrande법(동적)과 원추관입시험법(정적)으로 액성한계와 소성한계시험을 실시하여 실험방법과 실험자에 따른 액 소성한계 결정에 미치는 영향을 검토하였다. 총 6명의 실험경험을 가진 학생이 참여하였다. 액성한계시험결과, 원추관입시험법으로 구한 액성한계는 Casagrande법으로 구한 액성한계보다 약 4% 정도 작게 나타났다. 원추관입시험법에서 실험횟수의 증가함에 따라 비례적으로 실험자별 실험값의 차이가 작아지고, 숙련도의 변화 폭도 양호해지는 경향을 보였다. 1점법에서 원추콘관입시험법에 의해 결정된 액성한계 값의 변화는 작고 Casagrande법보다 좀 더 양호한 값을 얻을 수 있었다. 소성한계시험결과, 액성한계와는 다르게 두 시험법의 결과 차이는 없는 것으로 나타났다. 즉, 두 시험방법 모두 실험자별 소성한계는 실험횟수가 증가함에 따라 평균 소성한계 값에 근접해 가는 경향을 보이고 있으며 숙련도의 변화도 실험횟수가 증가 할수록 좋아 지는 경향을 보였다.

Estimation of Penetration Depth Using Acceleration Signal Analysis for Underwater Free Fall Cone Penetration Tester

  • Seo, Jung-min;Shin, Changjoo;Kwon, OSoon;Jang, In Sung;Kang, Hyoun;Won, Sung Gyu
    • 한국해양공학회지
    • /
    • 제34권3호
    • /
    • pp.202-207
    • /
    • 2020
  • A track-type underwater construction robot (URI-R) was developed by the Korea Institute of Ocean Science & Technology. Because URI-R uses tracks to move on the seabed, insufficient ground strength may hinder its movement. For smooth operation of URI-R on the seabed, it is important to determine the geotechnical properties of the seabed. To determine these properties, standard penetration test (SPT), cone penetration test (CPT), and sampling are used on land. However, these tests cannot be applied on the seabed due to a high cost owing to the vessel, crane, sampler, and analysis time. To overcome these problems, a free fall cone penetration tester (FFCPT) is being developed. The FFCPT is a device that acquires the geotechnical properties during impact/penetration/finish phases by free fall in water. Depth information is crucial during soil data acquisition. As the FFCPT cannot measure the penetration depth directly, it is estimated indirectly using acceleration. The estimated penetration depth was verified by results of real tests conducted on land.