• Title/Summary/Keyword: failure pressure

Search Result 1,655, Processing Time 0.034 seconds

An Analysis of Gas Accident between 1995 and 1998, and Suggestion of Accident Reduction Countermeasures. (1995 ${\~}$ 1998년 가스사고 분석 및 사고감소대척 제시)

  • Park Kyo-Shik;Kim Ji-Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.1-8
    • /
    • 2000
  • It is required that gas accidents should be managed carefully as the consumption of fuel gas increases and high pressure gas process becomes more complex, which may cause a catastrophic accident. Factors to cause accidents were investigated through a systematic analysis of gas accidents between 1995 and 1998, which could be applied to prepare countermeasures to reduce gas accidents. As a result, it was suggested that the effective countermeasures to gas accidents should be kept applied, while new countermeasures were suggested in the field of increasing or not-decreasing number of accident. Totally 2,027 of accidents were reported during this term, and were found to decrease by about $12\%$ every year from 1996. The number of fuel gas such as LPG and city gas accident took up $96\%$, and most of accidents occurred at end-user's facility such as residential house and restaurant business. According to the kind of gas and facility, trend of accident by cause varies, while dominant causes are defective installation, appliance failure, or user's carelessness. Intentional accidents by fuel gas was excluded in this study because of its occurring mechanism and will be analyzed further elsewhere, although it took up $15\%$ and increased by $38\%$ every year.

  • PDF

Non-Destructive Testing of Damaged Thermoplastic Pipes Electrofusion Joints Using Phased Array Ultrasonic (위상배열초음파를 이용한 손상된 열가소성 플라스틱배관 전기융착부 비파괴검사)

  • Kil, Seong-Hee;Kim, Byung-Duk;Kwon, Jeong-Rock;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.64-68
    • /
    • 2013
  • Non destructive testing(NDT) methods of electrofusion(EF) joints of thermoplastics pipes are required for fusion joint safety and for the long term reliability of a pipe system. Electrofusion joints, which are joined at the proper fusion process and procedures, may encounter defects due to the difference of ovality between pipes and coupling, improper fusion process or porosity result from electrofusion joining. These defects can cause the failure of pipeline and by extension, they can be caused the limit to expand the use of plastics pipes. This paper studies inspection results using ultrasonic imaging method for damaged polyethylene electrofusion joints. Gas was leaking from 250mm diameter polyethylene electrofusion joints at February 2004 which was electrofused at December 1994 and operation pressure was 2.45kPa. First, surface inspection was conducted and then in order to find the types of defects examination using ultrasonic imaging method was performed. Lack of fusion and inappropriate inserting for polyethylene pipes into electrofusion coupling were found and causes of the gas leak were judged that misalignment and insert defect. Cutting inspection was performed and each inspection results were compared to. Results of ultrasonic imaging method and cutting inspection were the same.

Cost-Benefit Analysis Method for Ageing Equipment of Chemical Plants Using Risk Assessment (위험성평가를 이용한 노후설비에 대한 비용 편익분석 방법)

  • Jung, Soomin;Jung, Changmo;Kang, Seok-Min;Chae, Seungbeen;Kang, Seung-Gyun;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.84-92
    • /
    • 2020
  • Most facilities in chemical plants operate in environments that are outside the range of temperature and pressure that can be encountered on a daily basis, and are vulnerable to aging due to these stresses and environmental conditions. The facilities exposed to these conditions are not only likely to fail due to cumulative damage, but also lead to accidents if maintenance and replacement are not performed.Recommendation guidelines called risk-based inspection are widely used around the world-wide. However, limits exist for facilities that have already elapsed for a certain. As a result of the survey on the aging of Ulsan industrial complex in Korea, which carries out proper inspection, many of the facilities have been used for 20 years. Also, most of the facilities where the accident occurred have been in operation for more than 20 years. Therefore, this study suggested criteria for classifying devices that have exceeded a certain period of use as obsolete facilities. In addition, quantitative risk assessment was conducted. The safety investment method using the cost-benefit analysis method was proposed in order to calculate the loss cost and reduce the risk by expressing the risks of the corresponding aged facility as an Economic index. By utilizing the method of cost-benefit analysis of old facilities using the quantitative risk assessment presented in this study, it can be expected to improve the performance and life of old facilities, improve production efficiency and reliability of the system of facilities, change the recognition of safety management costs, increase employee stability, and reduce loss costs.

A Study on the Analysis of Monitoring Settlement Considering the History of the Groundwater Level in the Dredged Landfill Area Affected by Algae (조류의 영향을 받는 준설매립지역에서 지하수위 이력을 고려한 계측침하 분석에 관한 연구)

  • Jang, Ji-Gun;Son, Su-Won;Hong, Seok-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.7
    • /
    • pp.13-23
    • /
    • 2021
  • If roads, bridges, buildings, etc. are built on the ground with soft clay or organic soil, there may be a lot of problems in geotechnical engineering such as settlement and stability due to the large settlement and lack of bearing capacity. In extreme cases, it may appear due to shear failure or collapse of the constructed structure, so a ground improvement method is indispensable to increase the strength of the ground and to suppress settlement. In this study, the settlement according to each groundwater level condition was analyzed using the measurement results for the groundwater level conditions, one of the important factors in predicting the settlement in dredged and reclaimed ground, and the groundwater level conditions applied to the settlement analysis were proposed by comparing it with settlement generated 5 years after construction. As a result of the analysis, it is judged that it is reasonable to apply the measured groundwater level during construction and the low water ordinary neap tide (L.W.O.N.T) during load application for the groundwater level in the settlement analysis. In addition, in the case of the dredged and reclaimed ground, it is estimated that the water pressure acting on the clay layer is nonlinear, as the result of the observations of the head of water at the observation points above and below the in-situ clay layer were different.

Thermodynamic Evaluations of Cesium Capturing Reaction in Ceramic Microcell UO2 Pellet for Accident-tolerant Fuel (사고저항성 핵연료용 세라믹 미소셀 UO2 소결체의 Cs 포집반응에 대한 열역학적 평가)

  • Jeon, Sang-Chae;Kim, Keon Sik;Kim, Dong-Joo;Kim, Dong Seok;Kim, Jong Hun;Yoon, Jihae;Yang, Jae Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.1
    • /
    • pp.37-46
    • /
    • 2019
  • As candidates for accident-tolerant fuels, ceramic microcell fuels, which are distinguished by their peculiar microstructures, are being developed; these fuels have $UO_2$ grains surrounded by cell walls. They contribute to nuclear fuel safety by retention of fission products within the $UO_2$ pellet, reducing rod pressure and incidence of SCC failure. Cesium, a hazardous fission product in terms of amount and radioactivity, can be captured by chemical reactions with ceramic cell materials. The capture-ability of cesium therefore depends on the thermodynamics of the capturing reaction. Conversely, compositional design of cell materials should be based on thermodynamic predictions. This study proposes thermodynamic calculations to evaluate the cesium capture-ability of three ceramic microcell compositions: Si-Ti-O, Si-Cr-O and Si-Al-O. Prior to the calculations, the chemical and physical states of the cesium and the cell materials were defined. Then, the reactivity was evaluated by calculating the cesium potential (${\Delta}G_{Cs}$) and oxygen potential (${\Delta}G_{O_2}$) under simulated LWR circumstances of normal operation. Based on the results, cesium capture is expected to be spontaneous in all cell compositions, providing a basis for the compositional design of ceramic microcell fuels as well as a facile way for evaluating cesium capture.

Clinical characteristics of heat stroke in bath facilities, and analysis of predictive factors of multiple major complications (목욕시설에서 발생한 열사병의 임상양상 및 열사병의 다발성 주요 합병증에 관한 예측인자 분석)

  • Park, Seok-Jin;Hyun, Sung-Youl;Lim, Yong-Su;Cho, Jin-Seong;Min, Kyoung-Jeen;Yang, Hyuk-Jun
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.5
    • /
    • pp.500-508
    • /
    • 2018
  • Objective: The aim of this study was to evaluate the clinical characteristics of heat stroke in a bath facility and investigate predictive factors of multiple major complications in heat stroke patients. Methods: This was a retrospective study on heat stroke patients who visited an urban emergency center from January 2010 to March 2018. We compared clinical characteristics, complication, and outcomes of heat stroke patients in bath and non-bath facilities. Multivariate logistic regression analysis were performed to identify independent predictors of multiple major complications in heat stroke patients. Results: A total of 67 heat stroke patients with heat stroke were enrolled, of which 42 (62.6%) were in a bath facility and 25 (37.3%) were in a non-bath facility. Patients with heat stroke in the bath facility were characterized by old age, past medical history of hypertension and diabetes mellitus, and high incidence of hypotension compared with those in the non-bath facility but also low incidence of acute renal failure, seizure, and multiple major complications. In the multivariate analysis, predictive factors of multiple major complications in heat stroke patients were non-bath facility (odds ratio [OR], 5.4; 95% confidence interval [CI], 1.2-29.9), Glasgow Coma Scale (GCS)${\leq}8$ (OR, 8.2; 95% CI, 1.3-49.4), and mean arterial pressure (MAP), body temperature above $40.5^{\circ}C$ (OR, 8.1; 95% CI, 1.1-58.8) <60 mmHg (OR, 14.8; 95% CI, 1.8-122.9). Conclusion: Heat stroke in the bath facility resulted in less major complications, and high body temperature, GCS ${\leq}8$, and MAP <60 mmHg were independent predictive factors of multiple major complications in heat stroke patients.

Clinical Experiences of High-Risk Pulmonary Thromboembolism Receiving Extracorporeal Membrane Oxygenation in Single Institution

  • Jang, Joonyong;Koo, So-My;Kim, Ki-Up;Kim, Yang-Ki;Uh, Soo-Taek;Jang, Gae-Eil;Chang, Wonho;Lee, Bo Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.3
    • /
    • pp.249-255
    • /
    • 2022
  • Background: The main cause of death in pulmonary embolism (PE) is right-heart failure due to acute pressure overload. In this sense, extracorporeal membrane oxygenation (ECMO) might be useful in maintaining hemodynamic stability and improving organ perfusion. Some previous studies have reported ECMO as a bridge to reperfusion therapy of PE. However, little is known about the patients that benefit from ECMO. Methods: Patients who underwent ECMO due to pulmonary thromboembolism at a single university-affiliated hospital between January 2010 and December 2018 were retrospectively reviewed. Results: During the study period, nine patients received ECMO in high-risk PE. The median age of the patients was 60 years (range, 22-76 years), and six (66.7%) were male. All nine patients had cardiac arrests, of which three occurred outside the hospital. All the patients received mechanical support with veno-arterial ECMO, and the median ECMO duration was 1.1 days (range, 0.2-14.0 days). ECMO with anticoagulation alone was performed in six (66.7%), and ECMO with reperfusion therapy was done in three (33.3%). The 30-day mortality rate was 77.8%. The median time taken from the first cardiac arrest to initiation of ECMO was 31 minutes (range, 30-32 minutes) in survivors (n=2) and 65 minutes (range, 33-482 minutes) in non-survivors (n=7). Conclusion: High-risk PE with cardiac arrest has a high mortality rate despite aggressive management with ECMO and reperfusion therapy. Early decision to start ECMO and its rapid initiation might help save those with cardiac arrest in high-risk PE.

Analysis on Behavior Characteristics of Underground Facility Backfilled with Clsm According to Adjacent Excavation (CLSM으로 되메움된 지하 인프라 매설물의 근접 굴착에 따른 거동특성 분석 )

  • Seung-Kyong, You;Nam-Jae, Yu;Gigwon, Hong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.4
    • /
    • pp.101-109
    • /
    • 2022
  • This study describes the results of model experiment to analyze the effect of backfill material types on the behavior of underground facility. In the model experiment, backfill materials around the existing underground facility were applied with soil (Jumunjin standard sand) and CLSM. The displacement of underground facility was analyzed for each excavation stage considering the separation distance between the excavation surface and the backfill area based on the experimental results. When soil was applied as a backfill material, the soil on the back of the excavation surface collapsed by excavation and formed an angle of repose, and the process of slope stability was repeated at each excavation stage. In addition, the displacement of underground facility began to occur in the excavation stage that the failure line of soil passes the installation location of the underground facility. When CLSM was applied as a backfill material, there was almost no horizontal and vertical displacement of the ground regardless of the separation distance from the excavation surface even when excavation proceeded to the backfill depth. Therefore, this result showed that it can have a resistance effect against the lateral earth pressure generated and the collapse of the original ground by adjacent excavation, if a backfill material with high stiffness such as CLSM is applied.

Implementation of Responsive Web-based Vessel Auxiliary Equipment and Pipe Condition Diagnosis Monitoring System (반응형 웹 기반 선박 보조기기 및 배관 상태 진단 모니터링 시스템 구현)

  • Sun-Ho, Park;Woo-Geun, Choi;Kyung-Yeol, Choi;Sang-Hyuk, Kwon
    • Journal of Navigation and Port Research
    • /
    • v.46 no.6
    • /
    • pp.562-569
    • /
    • 2022
  • The alarm monitoring technology applied to existing operating ships manages data items such as temperature and pressure with AMS (Alarm Monitoring System) and provides an alarm to the crew should these sensing data exceed the normal level range. In addition, the maintenance of existing ships follows the Planned Maintenance System (PMS). whereby the sensing data measured from the equipment is monitored and if it surpasses the set range, maintenance is performed through an alarm, or the corresponding part is replaced in advance after being used for a certain period of time regardless of whether the target device has a malfunction or not. To secure the reliability and operational safety of ship engine operation, it is necessary to enable advanced diagnosis and prediction based on real-time condition monitoring data. To do so, comprehensive measurement of actual ship data, creation of a database, and implementation of a condition diagnosis monitoring system for condition-based predictive maintenance of auxiliary equipment and piping must take place. Furthermore, the system should enable management of auxiliary equipment and piping status information based on a responsive web, and be optimized for screen and resolution so that it can be accessed and used by various mobile devices such as smartphones as well as for viewing on a PC on board. This update cost is low, and the management method is easy. In this paper, we propose CBM (Condition Based Management) technology, for autonomous ships. This core technology is used to identify abnormal phenomena through state diagnosis and monitoring of pumps and purifiers among ship auxiliary equipment, and seawater and steam pipes among pipes. It is intended to provide performance diagnosis and failure prediction of ship auxiliary equipment and piping for convergence analysis, and to support preventive maintenance decision-making.

The Prognosis of Glyphosate herbicide intoxicated patients according to their salt types (글라이포세이트 중독 환자에서 포함된 염의 종류에 따른 예후의 차이)

  • Jeong, Min Gyu;Keum, Kyoung Tak;Ahn, Seongjun;Kim, Yong Hwan;Lee, Jun Ho;Cho, Kwang Won;Hwang, Seong Youn;Lee, Dong Woo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.2
    • /
    • pp.83-92
    • /
    • 2021
  • Purpose: Glyphosate herbicide (GH) is a widely used herbicide and has been associated with significant mortality as poisoned cases increases. One of the reasons for high toxicity is thought to be toxic effect of its ingredient with glyphosate. This study was designed to determine differences in the clinical course with the salt-type contained in GH. Methods: This was a retrospective study conducted at a single hospital between January 2013 and December 2017. We enrolled GH-poisoned patients visited the emergency department. According to salt-type, patients were divided into 4 groups: isopropylamine (IPA), ammonium (Am), potassium (Po), and mixed salts (Mi) groups. The demographics, laboratory variables, complications, and their mortality were analyzed to determine clinical differences associated with each salt-type. Addtionally, we subdivided patients into survivor and non-survivor groups for investigating predictive factors for the mortality. Results: Total of 348 GH-poisoned patients were divided as follows: IPA 248, Am 41, Po 10, and Mi 49 patients. There was no difference in demographic or underlying disease history, but systolic blood pressure (SBP) was low in Po group. The ratio of intentional ingestion was higher in Po and Mi groups. Metabolic acidosis and relatively high lactate level were presented in Po group. As the primary outcome, the mortality rates were as follows: IPA, 26 (10.5%); Am, 2 (4.9%); Po, 1 (10%); and Mi, 1 (2%). There was no statistically significant difference in the mortality and the incidence of complications. Additionally, age, low SBP, low pH, corrected QT (QTc) prolongation, and respiratory failure requiring mechanical ventilation were analyzed as independent predictors for mortality in a regression analysis. Conclusion: There was no statistical difference in their complications and the mortality across the GH-salt groups in this study.