• 제목/요약/키워드: failure mode distribution

검색결과 181건 처리시간 0.031초

Experimental and numerical study on the stability of slurry shield tunneling in circular-gravel layer with different cover-span ratios

  • Liu, Xinrong;Liu, Dongshuang;Xiong, Fei;Han, Yafeng;Liu, Ronghan;Meng, Qingjun;Zhong, Zuliang;Chen, Qiang;Weng, Chengxian;Liu, Wenwu
    • Geomechanics and Engineering
    • /
    • 제28권3호
    • /
    • pp.265-281
    • /
    • 2022
  • A set of slurry shield test system capable of cutter cutting and slurry automatic circulation is used to investigate the deformation characteristics, the evolution characteristics of support resistance and the distribution and evolution process of earth pressure during excavating and collapsing of slurry shield tunneling in circular-gravel layer. The influence of cover-span ratio on surface subsidence, support resistance and failure mode of excavation face is also discussed. Three-dimensional numerical calculations are performed to verify the reliability of the test results. The results show that, with the decrease of the supporting force of the excavation face, the surface subsidence goes through four stages: insensitivity, slow growth, rapid growth and stability. The influence of shield excavation on the axial earth pressure of the front soil is greater than that of the vertical earth pressure. When the support resistance of the excavation face decreases to the critical value, the soil in front of the excavation face collapses. The shape of the collapse is similar to that of a bucket. The ultimate support resistance increase with the increase of the cover-span ratio, however, the angle between the bottom of the collapsed body and the direction of the tunnel excavation axis when the excavation face is damaged increase first and then becomes stable. The surface settlement value and the range of settlement trough decrease with the increase of cover-span ratio. The numerical results are basically consistent with the model test results.

Bond behavior between concrete and prefabricated Ultra High-Performance Fiber-Reinforced Concrete (UHPFRC) plates

  • Mansour, Walid;Sakr, Mohammed A.;Seleemah, Ayman A.;Tayeh, Bassam A.;Khalifa, Tarek M.
    • Structural Engineering and Mechanics
    • /
    • 제81권3호
    • /
    • pp.305-316
    • /
    • 2022
  • Externally bonded ultrahigh performance fiber-reinforced concrete (UHPFRC) is commonly used as a strengthening material for reinforced concrete (RC) structures. This study reports the results of an experimental program investigating the bonding behavior between concrete and prefabricated UHPFRC plates. The overall experimental program is consisting of five RC specimens, which are strengthened using the different lengths and widths of prefabricated UHPFRC plates. These specimens were analyzed using the pull-pull double-shear test. The performance of each strengthened specimen is presented, discussed and compared in terms of failure mode, maximum load, load-slip relationship, fracture energy and strain distribution. Specimen C-25-160-300 which bonded along the whole width of 160 mm recorded the highest maximum load (109.2 kN) among all the analysed specimens. Moreover, a 3D numerical finite element model (FEM) is proposed to simulate the bond behavior between concrete and UHPFRC plates. Moreover, this study reviews the analytical models that can predict the relationship between the maximum bond stress and slip for strengthened concrete elements. The proposed FEM is verified against the experimental program and then used to test 36 RC specimens strengthened with prefabricated UHPFRC plates with different concrete grades and UHPFRC plate widths. The obtained results together with the review of analytical models helped in the formation of a design equation for estimating the bond stress between concrete and prefabricated UHPFRC plates.

반복하중에 따른 수종 임플란트의 피로파절에 관한 연구 (Fatigue fracture of different dental implant system under cyclic loading)

  • 박원주;조인호
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.424-434
    • /
    • 2009
  • 연구목적: 임플란트는 수직교합 하중에는 비교적 잘 견디나 측방하중에 대해서는 약한 역학적 성질을 갖고 있으므로 임플란트의 재료 특성과 기하학적 형태에 따른 응력 분석 연구의 필요성이 제기되고 있다. 연구재료 및 방법: 외부육각구조를 갖는 28개의 임플란트를 7개씩 4군으로 나누어 그 제품에 적합한 UCLA gold abutment를 이용해, 제3형 금합금으로 보철 물을 제작하였고, A군 (3i, FULL $OSSEOTITE^{(R)}$-Implant), B군 (Nobelbiocare, Branemark $System^{(R)}$Mk III Groovy RP), C군 (Neobiotec, $SinusQuick^{(TM)}$ EB), D군 (Osstem, US-II)으로 분류하였다. 고정체와 지대주나사, 지대주를 연결한 후 수직적으로 절단하여 연마한 후 미세경도계를 이용하여 10군데에서 경도측정을 실시하였고, 동적하중 피로시험기를 이용하여 60-600 N범위로 파절시까지 동적 하중을 가하였다. 주사전자현미경을 이용하여 지대주나사 및 고정체의 파절 양상과 파절 위치 등을 관찰하였고, 유한요소분석을 통해 고정체와 지대주 나사에 나타나는 응력 분포와 파절면을 비교 분석하였다. 결과: 1.고정체 경도는 A, B, C, D군에서 각각 245.3, 289.7, 281.3, 300.4 Hv로 D군이 가장 높았고, A군이 가장 낮았다. 지대주 나사의 경도는 A, B, C, D군에서 각각 340.00, 317.62, 306.5, 306.2 Hv로 A군이 가장 높고, D군이 가장 낮았다. 2. 모든 실험군에서 임플란트 고정체의 파절은 응력이 집중되는 고정체 3-4번째 나사산 홈 (valley) 부위 또는 내면의 사공간부와 일치하는 부위에서 발생되었고, 피로수명은 A, B, C, D군에서 각각 31585, 47311, 30141, 105371로 D군이 가장 높았으며, A, B, C군과는 유의한 차이가 있었다(P<.05). 3. 파절양상은 B군과D군에서는 고정체와 나사 모두에서 수직 (longitudinal)파절과 수평 (transverse)파절이 동시에 일어나는 복합 (complex mode) 파절이 관찰 되었고, A와 C군에서는 고정체에서 수평 (transverse mode) 파절만이 관찰되었다. 4. 유한요소분석 결과 인장응력이 가장 높은 고정체 표면부에서 피로 균열이 시발되어 압축응력이 가장 높은 반대편 부위로 피로균열이 전파되었으며, 최대 유효 응력값은 C군이 가장 높았고, B군에서 가장 낮았다. 결론: 피질골 높이와 일치하는 임플란트 고정체 부위에서 최대 인장 주응력이 발생되며, 고정체 사공간부 (dead space)가 최대 인장 주응력이 작용하는 지그 표면과 일치할 때 피로파절이 발생되었다. 따라서 악골에 식립된 임플란트의 신뢰성을 향상시키고 수명을 증대시키기 위해서는 가능한 임플란트 주위의 골소실이 일어나지 않도록 해야 할 것이나 골흡수가 일어나 사공간부 수준까지 진행된다면 임플란트의 파절 빈도가 증가될 수 있으므로 이에 대한 대처가 필요할 것으로 사료된다.

지진에 의한 교량의 탄성받침장치 손상 원인 규명 (Identification of Failure Cause for Elastomeric Bearing in Bridge by Earthquakes)

  • 서영득;최형석;김인태;김정한;정영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.19-26
    • /
    • 2021
  • 교량 받침장치부는 상부구조의 수직하중을 지지하여 하부구조에 전달하고, 교량의 붕괴사고를 방지하는 역할을 한다. 하지만, 포항지진에 의하여 총 12개 도로교량의 받침장치 몰탈 파손, 받침장치 파손 및 쐐기 손상이 보고되었다. 본 연구에서는 지진시 교량 받침장치부의 구조 시스템 특성을 고려하여 교각의 코핑부와 무수축몰탈을 포함한 면진받침 장치 실험체의 전단 거동특성 및 손상모드를 평가하였다. 받침장치 쐐기에 대한 영향을 확인하기 위하여 쐐기 설치 유무를 변수로 설정하였으며, 압축-전단 실험을 실시하여 면진장치의 전단 거동특성과 손상모드를 확인하였다. 또한 유한요소해석을 통하여 받침장치의 거동특성 및 각 구성요소별 손상원인을 분석하였다. 실험결과, 쐐기의 충돌 및 손상 발생 이후 급격한 하중변화가 발생하였으며, 받침장치와 무수축몰탈 경계부를 따라 균열이 발생하였다. 쐐기 유무에 따른 쐐기, 앵커 소켓 및 무수축볼탈의 응력거동을 비교함으로써 지진시 교량받침장치부의 손상원인을 규명하였다.

LIGHT EMITTING DIODE로 광조사한 상아질 접착제의 상아질 전단접착강도와 중합률에 관한 연구 (Dentin bond strength of bonding agents cured with Light Emitting Diode)

  • 김선영;이인복;조병훈;손호현;김미자;석창인;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제29권6호
    • /
    • pp.504-514
    • /
    • 2004
  • LED 광중합기(Elipar FreeLight, 3M-ESPE)와 할로겐 광중합기(VIP Bisco)로 광조사한 수종의 상아질 접착제에 대해서 상아질 전단접착강도를 비교하였다 또한 이번 연구의 광학적 근거를 얻기 위해 두 광중합기의 파장에 따른 광강도와 스펙트럼을 비교하였다. 이번 연구에서 사용된 상아질 접착제는 Scotchbond Multipurpose (3M ESPE), Single Bond (3M ESPE). One-Step (Bisco), Clearfil SE Bond (Kuraray), Adper Prompt (3M ESPE) 이다. VIP는 487 nm에서 최대정점을 가지는 넓은 스펙트럼의 분포를 보이는 반면에, Elipar FreeLight는 465 nm에서의 최대정점을 중심으로 좁은 스펙트럼의 분포를 보였다. Clearfil SE bond를 제외하고 할로겐과 LED로 광조사 한 각 상아질 접착제에서 상아질 전단접착강도값의 유의성 있는 차이는 보이지 않았다 (P > 0.05). 이러한 결과는 camphoroquinone의 흡수스펙트럼과 LED의 좁은 영역의 스펙트럼사이에 강한 연관성으로 설명할 수 있다.

와이어로프로 외부 보강된 철근콘크리트 연속 T형 보의 전단내력 (Shear Capacity of Reinforced Concrete Continuous T-Beams Externally Strengthened with Wire Rope Units)

  • 양근혁;심재일;변항용
    • 콘크리트학회논문집
    • /
    • 제19권6호
    • /
    • pp.773-783
    • /
    • 2007
  • 와이어로프 단위를 이용한 단순한 비 부착형 전단보강 기술이 개발되었다. 제안된 보강 기술에 의해 보강된 연속 T형 보 6개와 동일한 무 보강 시험체가 실험되었다. 고려된 주요 변수는 와이어로프의 양과 프리스트레스이다. 모든 시험체의 기하학적 특성 및 철근 배근을 동일하다. 와이어로프의 프리스트레스로 인한 콘크리트 복부에서의 수직응력 분포가 보의 경사균열 전단내력 및 최대 전단내력에 미치는 영향이 또한 제시되었다. 본 연구의 실험 결과로부터 제안된 보강 기술을 이용하여 철근콘크리트 보의 전단내력 향상 및 연성을 확보하기 위해서는 와이어로프 비는 ACI 기준에서 제시하는 최소 전단철근비의 2.5배 이상, 그리고 프리스트레스는 와이어로프 인장강도의 0.6배 이하로 있어야 함이 제안될 수 있었다. 와이어로프 단위로 보강된 연속 T형 보의 전단내력을 평가하기 위하여 상계치 이론을 이용한 수치해석 모델이 제시되었다. 제시된 수치해석 모델은 ACI 318-05의 전단내력 식에 비해 실험 결과와 잘 일치하였다.

전면벽체 강성에 따른 쏘일네일링 벽체의 거동특성에 관한 실험적 고찰 (An Experimental Study of the Soil Nailed Wall Behavior with Front Plate Rigidity)

  • Kim, Hong-Taek;Kang, In-Kyu;Kwon, Young-Ho;Park, Si-Sam;Cho, Yong-Hoon
    • 한국지반공학회논문집
    • /
    • 제18권3호
    • /
    • pp.87-94
    • /
    • 2002
  • 최근 들어 국내에서는 경제적이고 효율적인 지하굴착공법으로 쏘일네일링 벽체와 지하구조물 외벽을 합벽처리하는 사례가 많아지고 있으며, 이같은 지하외벽 일체식 쏘일네일링 공법은 기존의 지보공법과 비교해 볼 때 굴착면적을 최소화하고 시공성을 개선할 수 있는 특징 이 있다. 또한 지하외벽 일체식 쏘일네일링 공법은 지하외벽의 단면 축소와 지하수에 의한 양압력의 영향에도 대처할 수 있는 장점이 있으나 아직까지는 이에 대한 연구가 미흡하여 보수적으로 설계되고 있는 실정이다. 이를 위해 본 연구에서는 실내모형실험을 통해 전면벽체의 강성에 따른 쏘일네일링 보강토체의 거동 및 네일의 두부에 작용하는 인발력을 분석하여 전면벽체의 강성에 따른 쏘일네일링 벽체의 파괴유형을 규명하고 사용상태 및 한계상태에서의 변위양상 및 네일 두부에서의 인장력 분포를 분석하였다. 또한 전면판의 강성이 쏘일네일링 벽테의 전체 안정성에 미치는 영향을 분석하였으며, 향후 전면벽체의 강성에 따른 지반-네일의 상호작용에 대한 모델개발에 필요한 기초적인 자료를 제공하고자 한다.

$Al/SiC/Al_{2}O_{3}$복합재료의 기계적 성질 및 마멸특성 (Mechanical Properties and Wear Behaviour of $Al/SiC/Al_{2}O_{3}$ Composite Materials)

  • 임흥준;김영한;한경섭
    • 대한기계학회논문집
    • /
    • 제17권10호
    • /
    • pp.2498-2508
    • /
    • 1993
  • $Al/SiC/Al_{2}O_{3}$ hybrid composites are fabricated by squeeze infiltration method. From the misconstructive of $Al/SiC/Al_{2}O_{3}$ hybrid composites fabricated by squeeze infiltration method, uniform distribution of reinforcements and good bondings are found. Hardness value of $Al/SiC/Al_{2}O_{3}$ hybrid composites increases linearly with the volume fraction of reinforcement because SiC whisker and $Al_{2}$O$_{3}$ fiber have an outstanding hardness. Optimal aging conditions are obtained by examining the hardness of $Al/SiC/Al_{2}O_{3}$ hybrid composites with different aging time. Tensile properties such as Young's modulus and ultimate tensile strength are improved up to 30% and 40% by the addition of reinforcements, respectively. Failure mode of $Al/SiC/Al_{2}O_{3}$ hybrid composites is ductile on microstructural level. Through the abrasive wear test and wear surface analysis, wear behaviour and mechanism of 6061 aluminum and $Al/SiC/Al_{2}O_{3}$ hybrid composites are characterized under various testing conditions. The addition of SiC whisker to $Al/SiC/Al_{2}O_{3}$ composites gives rise to improvement of the wear resistance. The wear resistance of $Al/SiC/Al_{2}O_{3}$ hybrid composites is superior to that of Al/SiC composites. The wear mechanism of aluminum alloy is mainly abrasive wear at low speed range and adhesive and melt wear at high speed range. In contrast, that of $Al/SiC/Al_{2}O_{3}$ hybrid composites is abrasive wear at all speed range, but severe wear when counter material is stainless steel. As the testing temperature increases, wear loss of aluminum alloy decreases because the matrix is getting more ductile, but that of $Al/SiC/Al_{2}O_{3}$ hybrid composites is hardly varied. Oil lubricant is more effective to reduce the wear loss of aluminum alloy and $Al/SiC/Al_{2}O_{3}$ hybrid composites at high speed range.

속채움 콘크리트 및 길이방향 철근으로 보강된 PHC 파일의 휨성능 (Flexural Performance of PHC Piles with Infilled concrete and Longitudinal Reinforcing Bars)

  • 한선진;이정민;김민석;김재현;김강수;오영훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권3호
    • /
    • pp.77-84
    • /
    • 2021
  • 이 연구에서는 속채움 콘크리트와 길이방향 철근으로 보강된 PHC 파일에 대한 휨실험을 수행하였으며, 실험의 주요 변수는 길이 방향 철근비와 PHC 파일 중공 내부 표면에 형성된 슬러지 유무로 설정하였다. 총 6개의 PHC 파일 실험체를 제작하였으며, 실험체들의 파괴모드, 균열패턴, 단면내 길이방향 변형률 분포, PHC 파일과 속채움 콘크리트 사이에 발생된 단부 슬립을 상세히 계측하고 분석하였다. 실험결과, 길이방향 철근비가 증가할수록 휨 강성 및 강도가 증가하는 것으로 나타났으며, PHC 파일 내부 표면에 형성된 슬러지는 실험체의 휨성능에 큰 영향을 미치지 않는 것으로 나타났다. 실험적 연구와 더불어 이 연구에서는 변형률 적합조건, PHC 파일과 속채움 콘크리트 단면내 변형률 및 응력 분포를 고려한 비선형 휨해석 모델을 제안하였으며, 해석결과를 실험결과와 비교하여 제안모델의 합리성을 검증하였다. 그 결과, 제안모델은 속채움 콘크리트와 길이방향 철근으로 보강된 PHC 파일의 휨거동을 매우 우수한 정확도로 평가하는 것으로 나타났다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF