• 제목/요약/키워드: failure event

검색결과 465건 처리시간 0.029초

현장 굴착 실험을 통한 사면붕괴 거동 연구 (A Study on behavior of Slope Failure Using Field Excavation Experiment)

  • 박성용;정희돈;김영주;김용성
    • 한국농공학회논문집
    • /
    • 제59권5호
    • /
    • pp.101-108
    • /
    • 2017
  • Recently, the occurrence of landslides has been increasing over the years due to the extreme weather event. Developments of landslides monitoring technology that reduce damage caused by landslide are urgently needed. Therefore, in this study, a strain ratio sensor was developed to predict the ground behavior during the slope failure, and the change in surface ground displacement was observed as slope failed on the field model experiment. As a result, in the slope failure, the ground displacement process increases the risk of collapse as the inverse displacement approaches zero. It is closely related to the prediction of precursor. In all cases, increase in displacement and reverse speed of inverse displacement with time was observed during the slope failure, and it is very important event for monitoring collapse phenomenon of risky slopes. In the future, it can be used as disaster prevention technology to contribute in reduction of landslide damage and activation of measurement industry.

시스템 결함원인분석을 위한 데이터 로그 전처리 기법 연구 (A Study on Data Pre-filtering Methods for Fault Diagnosis)

  • 이양지;김덕영;황민순;정영수
    • 한국CDE학회논문집
    • /
    • 제17권2호
    • /
    • pp.97-110
    • /
    • 2012
  • High performance sensors and modern data logging technology with real-time telemetry facilitate system fault diagnosis in a very precise manner. Fault detection, isolation and identification in fault diagnosis systems are typical steps to analyze the root cause of failures. This systematic failure analysis provides not only useful clues to rectify the abnormal behaviors of a system, but also key information to redesign the current system for retrofit. The main barriers to effective failure analysis are: (i) the gathered data (event) logs are too large in general, and further (ii) they usually contain noise and redundant data that make precise analysis difficult. This paper therefore applies suitable pre-processing techniques to data reduction and feature extraction, and then converts the reduced data log into a new format of event sequence information. Finally the event sequence information is decoded to investigate the correlation between specific event patterns and various system faults. The efficiency of the developed pre-filtering procedure is examined with a terminal box data log of a marine diesel engine.

내진성능확보를 위한 교량의 최적유지보수계획법 (Optimum Maintenance and Retrofit Planning for Reliable Seismic Performance of the Bridges)

  • 고현무;이선영;박관순;김동석
    • 한국지진공학회논문집
    • /
    • 제6권5호
    • /
    • pp.29-36
    • /
    • 2002
  • 교량의 내진성능확보를 위한 유지보수계획을 수립하는데 있어서, 전체 생애주기비용의 최소화를 통하여 최적의 검사 및 수리회수의 결정방법을 제시한다. 생애주기 비용에는 초기비용, 파괴비용 뿐만 아니라, 검사 및 보수비용이 포함된다. 시간에 따른 내진성능저하모델을 손상함수를 이용하여 표현하였으며, 손상감지정도에 따른 Event Tree Analysis를 통하여 유지보수에 따른 파괴확률을 랜덤진동이론을 이용하여 산출한다. 예제로서 10경간 연속교의 최적유지보수방법을 살펴본 결과, 가속도계수가 증가하고, 연약지반일수록 최적유지보수회수는 증가하는 것으로 나타났다.

Use of hazardous event frequency to evaluate safety integrity level of subsea blowout preventer

  • Chung, Soyeon;Kim, Sunghee;Yang, Youngsoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권3호
    • /
    • pp.262-276
    • /
    • 2016
  • Generally, the Safety Integrity Level (SIL) of a subsea Blowout Preventer (BOP) is evaluated by determining the Probability of Failure on Demand (PFD), a low demand mode evaluation indicator. However, some SIL results are above the PFD's effective area despite the subsea BOP's demand rate being within the PFD's effective range. Determining a Hazardous Event Frequency (HEF) that can cover all demand rates could be useful when establishing the effective BOP SIL. This study focused on subsea BOP functions that follow guideline 070 of the Norwegian Oil and Gas. Events that control subsea well kicks are defined. The HEF of each BOP function is analyzed and compared with the PFD by investigating the frequency for each event and the demand rate for the components. In addition, risk control options related to PFD and HEF improvements are compared, and the effectiveness of HEF as a SIL verification for subsea BOP is assessed.

여유고만으로 추정된 국내 재해위험 저수지의 지진시 파괴확률 (Seismic Failure Probability of the Korean Disaster Risk Fill Dams Estimated by Considering Freeboard Only)

  • 하익수;이수권;임정열;정영훈
    • 대한토목학회논문집
    • /
    • 제36권3호
    • /
    • pp.451-461
    • /
    • 2016
  • 본 연구의 목적은 소규모 필댐의 지진시 파괴확률을 산정하는 방법과 절차를 예시하고, 지반공학적 정보가 부족한 국내 재해위험 저수지의 지진시 파괴확률을 추정하는 것이다. 이를 위하여, 국내 재해위험 저수지로 지정된 저수지 중 지반공학적인 정보를 얻을 수 있는 7개 저수지에 대해 사건수 분석 기법을 적용하여 지진에 대한 파괴확률을 평가하였으며, 그 방법 및 절차를 예시하였다. 안전진단보고서를 확보한 84개 재해위험 저수지의 댐높이와 여유고와의 관계를 검토하였고, 미공병단 평가도구로 이용되는 파괴확률 산정식을 이러한 댐높이와 여유고와의 관계에 연관시켰다. 이러한 연관관계로부터, 지진시 파괴확률이 '0'이 되는 댐높이-여유고 임계곡선을 도출하였고, 이러한 임계곡선과 7개 저수지에 대해 산정한 지진시 파괴확률로부터 물성확보가 어려운 국내 재해위험 저수지의 개략적인 지진에 대한 파괴확률을 추정하였다.

ETA를 통한 연구실험실 콘센트회로의 전기재해 분석 (Analysis of Electrical Accident for Outlet Circuit of Laboratory on ETA)

  • 김두현;김성철;박종영;김상철
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.27-33
    • /
    • 2017
  • This study is intended to identify issues on the basis of investigating the actual state of laboratory environment and outlet circuit, and derive end states by expressing sequences from the initiating event of disaster to accident in leakage current, poor contact and overload through ETA(event tree analysis). To this end, this study investigated the actual state of electric equipment of laboratory at universities in all parts of country. And it is shown that most of them are failure in electric work and user negligence in the investigation of actual state. It is found that there is earth fault and defect in wire diameter in the failure of electric work and the problem of partial disconnection due to wire bundling and poor contact in user negligence. Outlet-related component, failure rate and initiating events are composed of a total of 41 initiating events, i.e., 30 internal initiating events and 11 external initiating events. And end states are composed of a total of 15 parts, i.e., 3 electric power parts and 12 safety parts. Earthing class 3 is the most important safety device against leakage current (initiating event). And in case of poor contact, it is necessary for manager to check thoroughly because there is no safety device. In case of overload/overcurrent, when high-capacity equipment is connected, a molded case circuit breaker, safety device, worked. However, in most cases, it is verified that this doesn't work. This study can be utilized as electric equipment safety guide for laboratory safety manager and managers.

FTA를 이용한 수변전설비의 최소절단집합 도출 (Minimal Cut Set of Electric Power Installations using Fault Tree Analysis)

  • 박영호;김두현;김성철
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.41-46
    • /
    • 2017
  • In this paper, from making an electrical fire which is thought to be the most damaging among potential dangers as a top event, minimal cut sets (MCS) about it were analyzed. For this, components of a power substation were classified into 15 items. Failure rates and modes were extracted based on Korea Electrical Safety Corporation, IEEE Gold Book, and RAC. To analyze the top event (an electrical fire), main events were assorted into "safety devices for overcurrent" and "ampere meter of detecter". Failure of components was divided into failure of VCB, COS, and MCCB. A fault tree was composed of 3 AND gate, 5 OR gates and 17 basic events. Overlapped events among the basic events are things which occur from relevant components. They were attached to the tree by distinguishing identifiers. In case of FT, two minimal cut sets of "IO_METER", "MF_METER", "DO_MCCB" and "IO_METER", "MF_METER", "DO_VCB" take 46% of electrical fires. Therefore, about basic events which are included in the top two minimum cut sets, strict control is necessary.

음향방출을 이용한 일방향 탄소섬유강화 플라스틱의 손상평가에 관한 연구 (A Study on the Damage Estimation of Uni-directionally Oriented Carbon Fiber Reinforced Plastics using Acoustic Emission)

  • 이장규;박성완;김봉각;우창기
    • 한국공작기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.30-36
    • /
    • 2005
  • This study is to investigate a damage estimation of single edge notched tensile specimens as a function of acoustic emission(AE) according to the uni-directionally oriented carbon fiber/epoxy composites, CFRP In fiber reinforced composite materials, AE signals due to several types of failure mechanisms are typically observed. These are due to fiber breakage, fiber pull-out matrix cracking, delamination, and splitting or fiber bundle breaking. And these are usually discriminated on the basis of amplitude distribution, event counts, and energy related parameters. In this case, AE signals were analyzed and classified 3 regions by AE event counts, energy and amplitude for corresponding applied load. Bath-tub curve shows 3 distinct periods during the lifetime of a single-edge-notch(SEN) specimen. The characterization of AE generated from CFRP during SEN tensile test is becoming an useful tool f3r the prediction of damage failure or/and failure mode analysis.

원전 노출 화재시 케이블 기능상실 온도에 관한 연구 (A Study on Cable Functional Failure Temperature by Exposed Fire in Nuclear Power Plants)

  • 김두현;임혁순
    • 한국안전학회지
    • /
    • 제26권5호
    • /
    • pp.41-45
    • /
    • 2011
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, the cables of the representative nuclear power plant in korea is selected and the cable functional failure temperature by exposed fire using Cable Response to Live Fire(CAROLFIRE) is studied. It is expected that the results are very useful to know the cable failure temperature by exposed fire. We confirmed the safety and integrity of the cable by exposed fire and those results will use the based data of cable exposed fire characteristics.

Fuzzy Sets을 이용한 시스템 부품의 고장가능성 진단에 관한 모델 (The possibility of failure of system component by fuzzy sets)

  • 김길동;조암
    • 품질경영학회지
    • /
    • 제20권2호
    • /
    • pp.44-54
    • /
    • 1992
  • In conventional fault-tree analysis, the failure probabilities of components of a system are treated as exact values in estimating the failure probability of the top event. For the plant layout and systems of the products, however, it is often difficult to evaluate the failure probabilities of components from past occurences, because the environments of the systems change. Furthermore, it might be necessary to consider possible failure of components of the systems even if they have never failed before. In the paper, instead of the probability of failure, we propose the possibility of failure, viz, a fuzzy set defined in probability space. Thus, in this paper based on a fuzzy fault-tree model, the maximum possibility of system failure is determined from the possibility of failure of each component within the system according to the extension principle.

  • PDF