• Title/Summary/Keyword: failure causes

Search Result 1,330, Processing Time 0.032 seconds

Failure Analysis of Optical Disk Drives Using the Vibration Signal Analysis (진동신호분석을 통한 광디스크 드라이브의 고장원인분석)

  • Park Youngpil;Shin Changho;Chung Jintai
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.7 s.238
    • /
    • pp.1028-1034
    • /
    • 2005
  • In this paper, the failure analysis of an optical disk drive is carried out and the limit ranges of the misalignment f3r the higher performance are presented. Since optical disks are removable from optical disk drive, the translational and angular misalignments, which causes read/write errors, always exist. Therefore, the limit ranges of the misalignment should be investigated. For this reason, the failure analysis by the vibration analysis is studied. The influences of the misalignment are tested by the aging test. And the limit ranges of the misalignment are proposed for the reliability of optical disk drives.

An Efficient Recovery Method for Mobile Main Memory Database System (모바일 메인메모리 데이터베이스 시스템을 위한 효율적인 복구 기법)

  • Cho, Sung-Je
    • Journal of Information Technology Services
    • /
    • v.7 no.2
    • /
    • pp.181-195
    • /
    • 2008
  • The rapid growth of mobile communication technology has provided the expansion of mobile internet services, particularly mobile realtime transaction takes much weight among mobile fields. There is an increasing demand for various mobile applications to process transactions in a mobile computing fields. Thus, During transmission in wireless networks a base station failure inevitably causes data loss of the base station buffer. It is required to compensate the loss for communication. The existing methods for a base station failure are not adequate because they all suffer from too much overhead and resolve only the link failure. In this paper, we study an efficient recovry systems for a mobile DBMS. We propose SLL (Segment Log List) that enables the mobile host to compensate data loss efficiently in the case of base station failure. In SLL, a base station deliveries an output information of data cells to a mobile host. when a base station fails, the mobile host can retransmit just next data cells. We also prove the efficiency of new method.

Failure Analysis of PSA applied electronics in home appliances (전자제품 적용 감압성 점착제(PSA)의 고장분석)

  • Kim, So-Yeon;In, Tae-Kyung;Kim, Jin-Woo;Kim, Myung-Su
    • Journal of Applied Reliability
    • /
    • v.9 no.4
    • /
    • pp.331-341
    • /
    • 2009
  • PSA (Pressure Sensitive Adhesive) is used for various purposes in electronic appliances such as double-sided tape for fitting parts, product's name plate, and surface protecting film, and so forth. In several kinds of PSAs, this paper dealt with the failure analysis of PET (Polyethylene Terephthalate) acrylic adhesive tapes. The causes of interface failure were investigated through the test of adhesive strength, thickness, and structure. And test standard methods to prevent recurrences were established.

  • PDF

A review of fatigue failures in LWR plants in Japan

  • Kunihiro, Iida
    • Proceedings of the KWS Conference
    • /
    • 1996.10a
    • /
    • pp.19-34
    • /
    • 1996
  • A review was made of fatigue failures of nuclear power plant components in Japan, which were experienced in service and during periodical inspection. No case has been recently reported of a service fatigue failure of a reactor pressure vessel itself, excluding nozzle corner cracks, that occurred many years ago. But, service fatigue failures have been occasionally experienced in piping systems, pumps, and valves, on which fatigue design seems to have been inadequately applied. The causes of fatigue failures can be divided into two categories: mechanical-vibration-induced fatigue and thermal-fluctuation-induced fatigue. Vibration-induced fatigue failure occurs more frequently than is generally thought. The lesson gleaned from the present survey is a recognition that a service fatigue failure may occur due to any one or a combination of the following factors: (1) lack of communication between designers and fabrication engineers, (2) lack of knowledge about a possibility of fatigue failure and poor consideration about the effects of residual stresses, (3) lack of consideration on possible vibration in the design and fabrication stages, and (4) lack of fusion or poor penetration in a welded joint.

  • PDF

Finite Element Analysis for Application of Torsion-free Brake Shoe Holder Hanger for the Bogie of Railway Freight Car (화차대차용 비틀림 흡수구조형 제륜자 홀더행거의 적용을 위한 유한요소해석)

  • Jeon Eung-Sik;Ham Young-Sam
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.36-41
    • /
    • 2003
  • Among welded structure bogies in use for high speed freight car, a part of bogies manufactured in 1999 and 2000 have found problems that failure occurs in its end beam. In case of a freight car a difference of weight between empty and loading conditions are worse than in case of a passenger car. Moreover its brake system is tread brake without second suspension system. A failure of end beam is supposed to be due to loading by brake rather than vertical loading by freight. This failure can make brake system useless and may be a cause of derailment in the worst case. In this study, we have proposed a simple torsion-free brake shoe holder hanger to remove torsion of hanger bracket which is supposed to be one of causes of failure and performed finite element analyses for making trial manufactures and its application.

  • PDF

The Case Study on Cadmium Embrittlement Failure of High Strength Bolt (고강도 볼트 카드늄 취성파괴 사례연구)

  • Yoon, Young-In
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.769-774
    • /
    • 2010
  • It happened fractures on special bolt which supported main landing gear actuator up-lock rod of aircraft. Cracks were initiated mainly from the center hole and the external thread of the special bolt. To find out failure root causes, metallographic, fractographic analyses as well as test work were carried out. From the fractographic study by SEM work, fracture occurred by a brittle intergranular type failure. The fracture could be occurred primarily by solid-metal-induced embrittlement due to cadmium embrittler penetrated into the flaw existed after machining work for center hole and thread on the bolt during baking treatment processing to eliminate hydrogen. For its successful application, cadmium EP bolts require proper and adequate baking treatment after electroplating, and make no more drilled center hole on the bolt to prevent same failure.

HIGH BURNUP FUEL ISSUES

  • Rudling, Peter;Adamson, Ron;Cox, Brian;Garzatolli, Friedrich;Strasser, Alfred
    • Nuclear Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • One of the major current challenges to nuclear energy lies in its competitiveness. To stay competitive the industry needs to reduce maintenance and fuel cycle costs, while enhancing safety features. Extended burnup is one of the methods applied to meet these objectives However, there are a number of potential fuel failure causes related to increased burnup, as follows: l) Corrosion of zirconium alloy cladding and the water chemistry parameters that enhance corrosion; 2) Dimensional changes of zirconium alloy components, 3) Stresses that challenge zirconium alloy ductility and the effect of hydrogen (H) pickup and redistribution as it affects ductility, 4) Fuel rod internal pressure, 5) Pellet-cladding interactions (PCI) and 6) pellet-cladding mechanical interactions (PCMI). This paper discusses current and potential failure mechanisms of these failure mechanisms.

Failure Investigation of Fire-Side Water-Wall Tube Boiler

  • Fatah, M.C.;Agustiadi, D.;Pramono, A.W.
    • Corrosion Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.242-248
    • /
    • 2021
  • Unforeseen failures of boilers in power plants may affect the continuation of electricity generation. Main failures in boilers are influenced by the tube material, tube position, boiler service temperature and pressure, and chemical composition of the feed water and coal. This investigation was intended to find answers on the causes and mechanism of failure of the fire-side boiler water-wall tubes, due to perforation and corrosion. The tube conformed to the material requirements in terms of its chemical composition and hardness. Microscopic examination showed ferrite and pearlite indicating no changes in its microstructure due to the temperature variation. SEM test showed a single layer and homogenous film density particularly on the area far from perforation. However, layers of corrosion product were formed on the nearby perforation area. EDX showed that there were Na, Ca, S, and O elements on the failed surface. XRD indicated the presence of Fe2O3 oxide. The failure mechanism was identified as a result of significant localized wall thinning of the boiler water wall-tube due to oxidation.

Analysis of Treatment Failure for the Pulmonary and Neck Tuberculosis (폐 및 경부 결핵에서 항결핵제에 의한 치료실패 원인분석)

  • Jeon, Chang-Ho;Lee, Sang-Chae;Hyun, Dae-Sung;Choe, Jung-Yoon;Shin, Im-Hee;Sohn, Jin-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.473-483
    • /
    • 2001
  • Background : There are only a few studies regarding the causes of treatment failure for tuberculosis. Therefore, this study aimed to determine the causes of intractable tuberculosis. Methods : M. tuberculosis, differentiated MOTT (Mycobacterium Other Than Tuberculosis) were isolated, and the RFLP (Restriction fragments length polymorphisms) pattern was analyzed from 204 patients with pulmonary tuberculosis and 53 suffering from neck tuberculosis. The IL-$1{\beta}$, IL-12, $^*1\;IFN{\gamma}$ and $^*2\;TNF{\alpha}$ blood levels were measured. All patients were regularly followed for 18 months after treatment. Results : There was no correlation between the RFLP patterns of M. tuberculosis treatment failure. From the 204 cases, 31.9% were intractable. The characteristics of patients with intractable tuberculosis were old age, being male and recurrent cases. The causes of treatment failure were identified as follows ; a decrease in the IL-12(59.4%) concentration, drug resistant strain(54.7%), irregular medication(15.4%), MOTT(6.2%) and a heavy infection(4.6%). The causes of all cases of intractable tuberculosis could be investigated. The IL-12 concentration in the blood was significantly lower in the intractable cases, where it disclosed a maximum sensitivity(64.7%) and specificity(75.4%) at 165.0 pg/mL. Most of the 53 cases of neck node tuberculosis were treated successfully. Therefore, we were unable to analyze the cause of treatment failure. Conclusion : A decrease in the blood IL-12 concentration and drug resistant strains were identified as the most significant causes of treatment failure for tuberculosis. In Korea, infection by clusters were prevalent, but no difference in the clinical course between clusters and non-clusters could be found.

  • PDF

Causes of Delay in Construction Projects in Bangladesh

  • Islam, Mohammad Saiful;Trigunarsyah, Bambang;Hassanain, Mohammad;Assaf, Sadi
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.82-86
    • /
    • 2015
  • Construction delay is a common problem worldwide, which is considered as one of the main reasons for project failure. Bangladesh construction industry is no exception. This study investigated the main causes of delay in large building construction projects in Bangladesh. A questionnaire survey was conducted to determine the causes of delay from owners, consultants, and contractors of large building construction projects. About 70 respondents participated in the survey. Using the importance index analysis, the study identified 10 most important causes of delay from a list of 30 different causes. Ten most important causes were: (1) lack of experienced construction manager, (2) lowest bidder selection, (3) funding shortage by owner, (4) lack of proper management, (5) improper planning and scheduling, (6) lack of skilled workers, (7) site constraints, (8) contractors' cash flow problems during construction, (9) escalation of resources price, and (10) contractors' excessive workload. Furthermore, Kruskal-Wallis test indicates that there is no significant variation exists among the three group of respondents, ie owners, consultants and contractors.

  • PDF