• Title/Summary/Keyword: failure

Search Result 22,660, Processing Time 0.058 seconds

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

A Study on the Effects of the Dine-out Franchise Headquarter's Management and Support Policies and Franchise Business Operator's Managerial Characteristics on the Bilateral Relationship and Franchise Store's Satisfaction (외식 프랜차이즈 가맹본부의 관리 및 지원정책과 가맹점 사업자의 경영자적 특성이 양자간 관계와 가맹점의 만족에 미치는 영향에 관한 연구)

  • Seo, SangYun;Jang, JaeNam
    • Journal of Distribution Research
    • /
    • v.17 no.4
    • /
    • pp.81-101
    • /
    • 2012
  • A franchise system develops competitive products for a franchise store through the system established by the franchise head office. Therefore, it has advantages of expanding the marketing effect since the risk of failure is reduced for a founder and the franchise head office supports the overall sales, advertisement and promotional activities. Also, a franchise store has advantages of fulfilling necessary facilities and tools on advantageous terms, reducing expenses by purchasing in bulk, and getting a supply of products with stable qualities. However, aside from such advantages, franchise head offices are forcing franchise stores to make unnecessary investments in equipments and remodel the interior. Also, franchise business operators are being made to share the cost of marketing and multiple franchise stores are being approved within the same business district, and franchise business operators are suffering damages. Therefore, cases of shutting down a franchise store or not renewing the contract are frequent. From the position of a franchise head office, profits that are generated from franchise fees, interior remodeling fees and supplying facilities and materials will increase as the number of new franchise stores increases. However, franchise stores are faced with difficulties due to excessive competitions between similar types of businesses and the overlapping of business districts that come from increases in the number of stores, and they eventually end up shutting down. Therefore, in order for a franchise business operator and franchise head office to grow and develop continuously, opening new stores is important, but successfully renewing the contract by maintaining a relationship with an existing franchise business operator is desirable. In this aspect, a study that examines the elements that can affect the relationship between a franchise business operator and franchise head office is believed to be important for the development of the franchise industry and creating safe jobs for the public. With an emphasis on the relationship between a franchise head office and franchise store, this study attempted to examine the effect of characteristics of a franchise head office and franchise business operator on the bilateral relationship such as the faith and immersion, and wished to review the effects of such faith and immersion on the satisfaction of a franchise store, including an intention of renewing the contract. In particular, in the current situation of great uncertainties in the market, this study also wished to examine how uncertain market elements will affect the relationship between the characteristics of a franchise head office and franchise business operator, and the faith and immersion. The study revealed that among the characteristics of a franchise head office, the standardization management of a franchise head office hinders a franchise store's faith and immersion in a franchise head office. Also, a franchise head office's support was shown to increase a franchise store's faith and immersion. However, it was revealed that a franchise head office's regulation and incentive policies for a franchise store do not affect a franchise store's faith and immersion. Among characteristics of a franchise business operator, a franchise store's healthy financial status and entrepreneur spirits were shown to enhance the faith and immersion in a franchise head office. However, it was shown that excellent business abilities of a franchise business operator actually reduce the immersion for a franchise head office. Also, the faith and immersion in a franchise head office were shown to enhance the intention of renewing the contract by increasing the satisfaction for a franchise head office. In addition, it was originally believed that the effects of a franchise business operator's characteristics on the faith and immersion in a franchise head office will vary depending on the market uncertainty, but the effect of a franchise business operator's characteristics depending on the recognition of uncertainties was shown to be insignificant. Such findings show that instead of making a franchise store pay for equipment investments and marketing and obtaining profits by force, a franchise head office should actively support a franchise store so that a franchise store's business activities can be conducted well, which will bring profits to a franchise store and ultimately to a franchise head office. This is a more desirable direction for the development of both parties. Implications of such findings are summarized as follows. First, it was shown that a franchise head office's standardization management actually reduces a franchise store's faith and immersion. Therefore, it is believed that instead of conducting standardization managements for regulating and managing franchise stores, measures should be developed so that franchise stores can actually participate voluntarily. For this, a head office should put in efforts to develop and provide standardized manuals, and make sure that a self-review system takes root. Second, a franchise head office's incentives did not have significant effects on the faith and immersion, but the support was shown to be effective. Therefore, it can be seen that instead of taking post-measures for a franchise store, taking pre-measures of actively supporting is more effective in maintaining a franchise store. Third, among characteristics of a franchise head office, it was shown that a franchise store's healthy financial status increased the faith and immersion in a franchise head office. Therefore, when selecting a franchise business operator, instead of thoughtlessly opening up franchise stores for the profit of a head office, it is believed that reviewing a franchise business operator's financial firepower and credit status is necessary. As for academic implications, previous studies examined the relationship by focusing on the characteristics of a franchise head office and franchise store, but this study focused on the characteristics of a franchise business operator. Therefore, this study dealt with the importance of a franchise business operator's competence, and is significant because it revealed the fact that a franchise business operator's excellent commercialization ability can become an element that hinders the immersion in a franchise head office. It was originally believed that a franchise store's characteristics will have different effects on the faith and immersion depending on the market uncertainty, but it was shown that the effect of a franchise store's characteristics depending on the recognition of uncertainties was insignificant, and that is the limitation of this study.

  • PDF

The Three Types of Clinical Manifestation of Cow's Milk Allergy with Predominantly Intestinal Symptoms (위장관 증세 위주로 발현하는 영유아기 우유 알레르기 질환의 3가지 임상 유형에 관한 고찰)

  • Lee, Jeong-Jin;Lee, Eun-Joo;Kim, Hyun-Hee;Choi, Eun-Jin;Hwang, Jin-Bok;Han, Chang-Ho;Chung, Hai-Lee;Kwon, Young-Dae;Kim, Yong-Jin
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.3 no.1
    • /
    • pp.30-40
    • /
    • 2000
  • Purpose: During the first year of life, cow's milk protein is the major offender causing food allergy. Cow's milk allergy (CMA) affects 2~7% of infants, of which approximately one-half show predominantly gastrointestinal symptoms. We studied the clinical types of cow's milk allergy with predominantly gastrointestinal symptoms (CMA-GI) of childhood. Methods: The retrospective study was performed on 30 (male 22, female 8) patients who had diagnosed as CMA-GI during 2 years and 3 months from March 1995 to June 1997. Results: 1) Children with CMA-GI presented in the three types of clinical manifestation on the basis of time to reaction to milk ingestion: Quick (Q) onset (5 cases), Slow (S) onset (20 cases), Quick & Slow (Q&S) (5 cases). 2) Age on admission of the three groups was significantly different (p<0.05): (Q onset: $81.4{\pm}67.1$ days, S onset: $31.9{\pm}12.7$ days, Q&S: $366.0{\pm}65.0$ days). Although the body weight at birth was 10~95 percentile in all patients, body weight on admission was different: (Q onset: 10~50 percentile, S onset: below 10 percentile, Q&S: 10~25 percentile). S onset group was significantly different compared with other groups (p<0.05) and 90% of this one was failure to thrive below 3 percentile. 3) Peripheral leukocyte counts were as followings: (Q onset: $5,700{\sim}12,300/mm^3$, S onset: $10,000{\sim}33,400/mm^3$, Q&S: $5,200{\sim}14,900/mm^3$). Slow onset group was significantly different compared with other groups (p<0.05). Serum albumin levels on admission were as followings: (Q onset: $4.2{\pm}0.4\;g/dl$, S onset: $3.0{\pm}0.3\;g/dl$, Q&S: $4.0{\pm}0.3\;g/dl$). S onset group was significantly different compared with other groups (p<0.05) and 85% of this one was below 3.5 g/dl. 4) Although morphometrical analysis on small intestinal mucosa did not show enteropathy in Q onset and Q&S groups, all cases of S onset revealed enteropathy: 45% of this one showed subtotal villous atrophy, 55 % showed partial villous atrophy. 5) Allergic reaction test to other foods was not performed in S onset group because of ethical problem and high risk in general condition. In Q onset group, allergic reaction to one or two other foods: soy formula, weaning formula and eggs. Q&S goup revealed allergic reactions to several foods or to most of all foods except protein hydrolysate formula: eggs, potatos, some kinds of sea food, apples, carrots, beef and chicken. 6) Serum IgE level, peripheral eosinophil counts, milk RAST, soy RAST, skin test were not significantly different among groups. Conclusion: CMA-GI may present in three clinical ways on the basis of time to reaction to milk ingestion, typical clinical findings and morphologic changes in the small bowel mucosal biopsy specimens. This clinical subdivision might be helpful in diagnostic and therapeutic approaches in CMA-GI. Early suspicion is mandatory especially in S onset type because of high risks with malnutrition and enteropathy.

  • PDF

Once vs. Twice Daily Thoracic Irradiation in Limited Stage Small Cell Lung Cancer (국한성 병기 소세포폐암의 방사선치료시 분할 조사방식에 따른 치료성적)

  • Kim, Jun-Sang;Kim, Jae-Sung;Kim, Ju-Ock;Kim, Sun-Young;Cho, Moon-June
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.291-301
    • /
    • 1998
  • Purpose : A retrospective study was conducted comparing single daily fraction (SDF) thoracic radiotherapy (TRT) with twice daily (BID) TRT to determine the potential benefit of BID TRT in limited-stage small cell lung cancer (SCLC). Endpoints of the study were response. survival, pattern of failure, and acute toxicity. Materials and Methods : Between November 1989 to December 1996, 78 patients with histologically proven limited-stage SCLC were treated at the Department of Therapeutic Radiology, Chungnam National University Hospital. Of these, 9 were irradiated for palliative intent, and 1 had recurrent disease. Remaining 68 patients were enrolled in this study. There were 26 patients with a median age of 58 years, and 22 (85$\%$) ECOG performance score of less than 1 in SDF TRT. There were 42 patients with a median age of 57 years, and 36 (86$\%$) ECOG performance score of less than 1 in BID TRT By radiation fractionation regimen, there were 26 in SDF TRT and 42 in BID TRT. SDF TRT consisted of 180 cGy, 5 days a week. BID TRT consisted of 150 cGy BID, 5 days a week in 13 of 42 and 120 cGy BID, in 29 of 42. And the twice daily fractions were separated by at least 4 hours. Total radiotherapy doses were between 5040 and 6940 cGy (median, 5040 cGy) in SDF TRT and was between 4320 and 5100 cGy (median, 4560 cGy) in BID TRT. Prophylactic cranial irradiation (PCI) was recommended for patients who achieved a CR. The recommended PCI dose was 2500 cGy/10 fractions. Chemotherapy consisted of CAV (cytoxan 1000 mg/$m^2$, adriamycin 40 mg/$m^2$, vincristine 1 mg/$m^2$) alternating with VPP (cisplatin 60 mg/$m^2$, etoposide 100 mg/$m^2$) every 3 weeks in 25 (96$\%$) of SDF TRT and in 40 (95$\%$) of BID TRT. Median cycle of chemotherapy was six in both group. Timing for chemotherapy was sequential in 23 of SDF TRT and in 3 BID TRT, and concurrent in 3 of SDF TRT and in 39 of BID TRT Follow-up ranged from 2 to 99 months (median, 14 months) in both groups. Results : Of the 26 SDF TRT, 9 (35$\%$) achieved a complete response (CR) and 14 (54$\%$) experienced a partial response (PR). Of the 42 BID TRT, 18 (43$\%$) achieved a CR and 23 (55$\%$) experienced a PR. There was no significant response difference between the two arms (p=0.119). Overall median and 2-year survival were 15 months and 26.8$\%$, respectively. The 2-year survivals were 26.9$\%$ and 28$\%$ in both arm, respectively (p=0.51). The 2-rear survivals were 35$\%$ in CR and 24.2$\%$ in PR, respectively. The grade 2 to 3 esophageal toxicities and grade 2 to 4 neutropenias were more common in BID TRT (p=0.028 0.003). There was no difference in locoregional and distant metastasis between the two arms (p=0 125 and 0.335, respectively). The most common site of distant metastasis was the brain. Conclusion : The median survival and 2-year survival were 17 months and 20.9$\%$ in SDF TRT with sequential chemotherapy, and 15 months and 28$\%$ in BID TRT with concurrent chemotherapy, respectively. We did not observe a substantial improvement of long-term survival in the BID TRT with concurrent chemotherapy compared with standard schedules of SDF TRT with sequential chemotherapy. The grade 2 to 3 esophageal toxicities and glade 2 to 4 neutropenias were more common in BID TRT with concurrent chemotherapy. Although the acute toxicities were more common in BID TRT with concurrent chemotherapy than SDF TRT with sequential chemotherapy, a concurrent chemotherapy and twice daily TRT was feasible. However further patient accrual and long-term follow up are needed to determine the potential benefits of BID TRT in limited-stage SCLC.

  • PDF

Clinical Aspects of Bacteremia in Medical and Surgical Intensive Care Units (내과 및 외과계 중환자실 환자 균혈증의 임상적 고찰)

  • Kim, Eun-Ok;Lim, Chae-Man;Lee, Jae-Kyoon;Mung, Sung-Jae;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Pyung-Hwan;Choi, Jong-Moo;Pai, Chik-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.535-547
    • /
    • 1995
  • Background: Intensive care units(ICUs) probably represent the single largest identifiable source of infection within the hospital. Although there are several studies on ICU infections in respect to their bacteriology or mortality rate for individual types of ICU, few studies have compared ICU infections between different types of ICU. The aim of this study was to identify clinical differences in bacteremia between medical ICU(MICU) and surgical ICU(SICU) patients. Methods: 256 patients with bacteremia were retrospectively evaluated. Medical records were reviewed to obtain the clinical and bacteriologic informations. Results: 1) The mean age of the patients with bacteremia of MICU($58.6{\pm}17.2\;yr$) was greater than that of all MICU patients($54.3{\pm}17.1\;yr$)(p<0.01), but there was no significant difference in SICU patients(patients with bacteremia of SICU: $56.3{\pm}18.6\;yr$, all SICU patients: $62.0{\pm}16.8$)(p>0.05). ICU stay was longer(MICU patients: $23.4{\pm}40.8$ day, SICU patients: $30.3{\pm}26.8$ day) than the mean stay of all patients($6.8{\pm}15.5$ day)(p<0.05, respectively). Bacteremia of both ICU patients developed past the average day of ICU stay(all MICU patients: 7.9 day, all SICU patients: 6.0 day, MICU bacteremia: 19th day, SICU bacteremia: 17th day of ICU stay)(p<0.05, respectively). 2) There were no significant differences in mean age, sex, and length of stay of both ICU patients with bacteremia. 3) Use of antibiotics or steroid, use of percutaneous devices and invasive procedures before development of bacteremia were more frequent in SICU patients than in MICU patients(prior antibiotics use: MICU 45%, SICU 63%, p<0.05; steroid use: MICU 14%, SICU 36%, p<0.01; use of percutaneous devices: MICU 19%, SICU 39%, p<0.01; invasive procedures: MICU 19%, SICU 61 %, p<0.01). 4) The prevalence of community acquired infections was significantly higher in MICU patients than in SICU patients(MICU 42%, SICU 9%)(p<0.01), whereas SICU patients showed higher prevalence of ICU-acquired infection than MICU patients(MICU 48%, SICU 78%)(p<0.01). 5) There were no differences in causative organisms, primary sites of infection and time interval to bacteremia between both ICUs. 6) There were no significant differences in outcome according to pathogenic organisms or primary sites of infection. 7) The mortality rate was higher in patients with bacteremia than without bacteremia(MICU mortality rate: patients with bacteremia 72.5%, patients without bacteremia 36.0%, p<0.01; SICU mortality rate: patients with bacteremia 40.3%, patients without bacteremia 8.5%, p<0.05), and the mortality rate of MICU bacteremia was significantly higher compared with that of SICU bacteremia(MICU 72.5%, SICU 40.3%)(p<0.01). Conclusion: ICU patients with bacteremia stayed longer before the development of bacteremia, and showed higher mortality than the overall ICU population. The incidence of bacteremia was higher in MICU patients than SICU patients. MICU patients with bacteremia showed higher prevalence of liver diseases and acute respiratory failure, community-acquired bacteremia and greater mortality rate than SICU patients with bacteremia. SICU patients with bacteremia, on the other hand, showed higher prevalence of trauma, prior use of immunosuppressive agents, invasive procedures, and ICU-acquired bacteremia, and lower mortality rate than MICU patients with bacteremia.

  • PDF

Clinical Characteristics of Pulmonary Aspergilloma (폐국균종의 임상적 고찰)

  • Kang, Tae-Kyung;Kim, Chang-Ho;Park, Jae-Yong;Jung, Tae-Hoon;Sohn, Jeong-Ho;Lee, Jun-Ho;Han, Seong-Beom;Jeon, Young-Jun;Kim, Ki-Beom;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo;Shin, Hyeon-Soo;Lee, Sang-Chae;Kweon, Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1308-1317
    • /
    • 1997
  • Background : Pulmonary aspergillomas usually arise from colonization and proliferation of Aspergillus in preexisting cavitary lung disease of any cause. About 15% of patients with tuberculous pulmonary cavities were found to have aspergilloma. We analyzed the clinical features and course of 91 patients with pulmonary aspergilloma. Method : During the ten-year period from June 1986 to May 1996, 91 patients whose condition was diagnosed as pulmonary aspergilloma at 4 university hospitals in Taegu city were reviewed. All patients fulfilled one of the following criteria : 1) histologic evidence of aspergilloma within abnormal air space in tissue sections, or 2) a positive Aspergillus serum precipitin test with the radiologic finding of a fungus ball. The histological diagno-sis was established in 81 patients(89.0%) and clinical diagnosis in 10 patients(11.0%). Results : 1) The age range was 22 to 65 years, with an average of 45 years. A male and female ratio was 1.7 : 1 (57 men and 34 women). 2) Hemoptysis was far the most frequent symptom(89%), followed by cough, dyspnea, weakness, weight loss, fever, chest pain. 3) In all but 14 cases(15.4%) there had been associated conditions. Pulmonary tuberculosis was far the most frequent underlying condition found(74.7%), followed by bronchiectasis (6.6%), cavitary neoplasm(2.2%), pulmonary sequestration(1.1%). 4) The involved area was usually in the upper lobes; the right upper lobe was involved in 39(42.9%), the left upper lobe in 31(34.1%), the left lower lobe in 13(14.3%), the right lower lobe in 7(7.7%), and the right middle lobe in 1(1.1%). 5) On standard chest roent geno gram the classic "bell-like" image of a fungus ball was found in 62.6% of the subjects. On CT scan, 88.1% of the subjects in which they were done. 6) The surgical therapy was undertaken in 76 patients, and medical therapy in 15 patients, including 4 patients with intracavitary instillation of amphotericin B. 7) The surgical modality was lobectomy in 55 patients(72.4%), segmentectomy in 16 patients(21.1%), pneumonectomy in 4 patients(5.3%), wedge resection in 1 patient(1.3%). The mortality rate was 3.9% (3 patients) ; 2 patients died of sepsis and 1 died of hemoptysis. The postoperative complications were encountered in 6 patients (7.9%), including each one patient with respiratory failure, bleeding, bronchopleural fistula, empyema, and vocal cord paralysis. 8) In the follow-up cases, each 2 patients of 71 patients with surgical treatment and 10 patients with medical treatment had recurrent hemoptysis. Conclusion : During follow-up of the chronic pulmonary disease with abnormal air space, if the standard chest roentgenograms are insufficient to detect a fungus ball, computed tomographic scan and serum precipitin test are likely to aid the diagnosis of patients with suspected pulmonary aspergilloma. A reasonable recommendation for management of a patient with aspergilloma would be to reserve surgical resection for those patients who have had severe, recurrent hemoptysis. And a well controlled cooperative study to the medical treatment such as intracavitary antifungal therapy is further needed.

  • PDF

An Empirical Study on the Influencing Factors for Big Data Intented Adoption: Focusing on the Strategic Value Recognition and TOE Framework (빅데이터 도입의도에 미치는 영향요인에 관한 연구: 전략적 가치인식과 TOE(Technology Organizational Environment) Framework을 중심으로)

  • Ka, Hoi-Kwang;Kim, Jin-soo
    • Asia pacific journal of information systems
    • /
    • v.24 no.4
    • /
    • pp.443-472
    • /
    • 2014
  • To survive in the global competitive environment, enterprise should be able to solve various problems and find the optimal solution effectively. The big-data is being perceived as a tool for solving enterprise problems effectively and improve competitiveness with its' various problem solving and advanced predictive capabilities. Due to its remarkable performance, the implementation of big data systems has been increased through many enterprises around the world. Currently the big-data is called the 'crude oil' of the 21st century and is expected to provide competitive superiority. The reason why the big data is in the limelight is because while the conventional IT technology has been falling behind much in its possibility level, the big data has gone beyond the technological possibility and has the advantage of being utilized to create new values such as business optimization and new business creation through analysis of big data. Since the big data has been introduced too hastily without considering the strategic value deduction and achievement obtained through the big data, however, there are difficulties in the strategic value deduction and data utilization that can be gained through big data. According to the survey result of 1,800 IT professionals from 18 countries world wide, the percentage of the corporation where the big data is being utilized well was only 28%, and many of them responded that they are having difficulties in strategic value deduction and operation through big data. The strategic value should be deducted and environment phases like corporate internal and external related regulations and systems should be considered in order to introduce big data, but these factors were not well being reflected. The cause of the failure turned out to be that the big data was introduced by way of the IT trend and surrounding environment, but it was introduced hastily in the situation where the introduction condition was not well arranged. The strategic value which can be obtained through big data should be clearly comprehended and systematic environment analysis is very important about applicability in order to introduce successful big data, but since the corporations are considering only partial achievements and technological phases that can be obtained through big data, the successful introduction is not being made. Previous study shows that most of big data researches are focused on big data concept, cases, and practical suggestions without empirical study. The purpose of this study is provide the theoretically and practically useful implementation framework and strategies of big data systems with conducting comprehensive literature review, finding influencing factors for successful big data systems implementation, and analysing empirical models. To do this, the elements which can affect the introduction intention of big data were deducted by reviewing the information system's successful factors, strategic value perception factors, considering factors for the information system introduction environment and big data related literature in order to comprehend the effect factors when the corporations introduce big data and structured questionnaire was developed. After that, the questionnaire and the statistical analysis were performed with the people in charge of the big data inside the corporations as objects. According to the statistical analysis, it was shown that the strategic value perception factor and the inside-industry environmental factors affected positively the introduction intention of big data. The theoretical, practical and political implications deducted from the study result is as follows. The frist theoretical implication is that this study has proposed theoretically effect factors which affect the introduction intention of big data by reviewing the strategic value perception and environmental factors and big data related precedent studies and proposed the variables and measurement items which were analyzed empirically and verified. This study has meaning in that it has measured the influence of each variable on the introduction intention by verifying the relationship between the independent variables and the dependent variables through structural equation model. Second, this study has defined the independent variable(strategic value perception, environment), dependent variable(introduction intention) and regulatory variable(type of business and corporate size) about big data introduction intention and has arranged theoretical base in studying big data related field empirically afterwards by developing measurement items which has obtained credibility and validity. Third, by verifying the strategic value perception factors and the significance about environmental factors proposed in the conventional precedent studies, this study will be able to give aid to the afterwards empirical study about effect factors on big data introduction. The operational implications are as follows. First, this study has arranged the empirical study base about big data field by investigating the cause and effect relationship about the influence of the strategic value perception factor and environmental factor on the introduction intention and proposing the measurement items which has obtained the justice, credibility and validity etc. Second, this study has proposed the study result that the strategic value perception factor affects positively the big data introduction intention and it has meaning in that the importance of the strategic value perception has been presented. Third, the study has proposed that the corporation which introduces big data should consider the big data introduction through precise analysis about industry's internal environment. Fourth, this study has proposed the point that the size and type of business of the corresponding corporation should be considered in introducing the big data by presenting the difference of the effect factors of big data introduction depending on the size and type of business of the corporation. The political implications are as follows. First, variety of utilization of big data is needed. The strategic value that big data has can be accessed in various ways in the product, service field, productivity field, decision making field etc and can be utilized in all the business fields based on that, but the parts that main domestic corporations are considering are limited to some parts of the products and service fields. Accordingly, in introducing big data, reviewing the phase about utilization in detail and design the big data system in a form which can maximize the utilization rate will be necessary. Second, the study is proposing the burden of the cost of the system introduction, difficulty in utilization in the system and lack of credibility in the supply corporations etc in the big data introduction phase by corporations. Since the world IT corporations are predominating the big data market, the big data introduction of domestic corporations can not but to be dependent on the foreign corporations. When considering that fact, that our country does not have global IT corporations even though it is world powerful IT country, the big data can be thought to be the chance to rear world level corporations. Accordingly, the government shall need to rear star corporations through active political support. Third, the corporations' internal and external professional manpower for the big data introduction and operation lacks. Big data is a system where how valuable data can be deducted utilizing data is more important than the system construction itself. For this, talent who are equipped with academic knowledge and experience in various fields like IT, statistics, strategy and management etc and manpower training should be implemented through systematic education for these talents. This study has arranged theoretical base for empirical studies about big data related fields by comprehending the main variables which affect the big data introduction intention and verifying them and is expected to be able to propose useful guidelines for the corporations and policy developers who are considering big data implementationby analyzing empirically that theoretical base.

A Study on Rationalization of National Forest Management in Korea (국유림경영(國有林經營)의 합리화(合理化)에 관(關)한 연구(硏究))

  • Choi, Kyu-Ryun
    • Journal of Korean Society of Forest Science
    • /
    • v.20 no.1
    • /
    • pp.1-44
    • /
    • 1973
  • Needless to say, the management of national forest in all countries is very important in view of the national mission and management purposes. Korean national forest is also in particular significant in promoting national economy for the continuous increasing of the demand for wood, conservation of the land and social welfare. But there's no denying the fact that the leading aim of the Korean forest policy has been based upon the conservation of forest resources and recovery of land conservation function instead of improvement of the forest productive capacity. Therefore, the management of national forest should be aimed as an industry in the chain of the Korean national economy. And the increment of the forest productive capacity based on rationalized forest management is also urgently needed. Not only the increment of the timber production but also the establishment of the good forest in quality and quantity are to bring naturally many functions of conservation and other public benefits. In 1908 Korean national forest was historically established for the first time as a result of the notification for ownership, and was divided into two kinds in 1911-1924, such as indisposable national forest for land conservation, forest management, scientific research and public welfare, and the other national forest to be disposed. Indisposable forest is mostly under the jurisdiction of national forest stations (Chungbu, Tongbu, Nambu), and the tother national forests are under custody of respective cities and provinces, and under custody of the other government authorities. As of the end of 1971, national forest land is 19.5% (1,297,708 ha) of the total forest land area, but growing stock is 50.1% ($35,406,079m^3$) of the total forest growing stock, and timber production of national forest is 23.6% ($205,959m^3$) of the year production of total timber in Korea. Accordingly, it is the important fact that national forest occupies the major part of Korean forestry. The author positively affirms that success or failure of the management of national forest controls rise or fall of forestry in Korea. All functions of forest are very important, but among others the function of timber production is most important especially in Korea, that unavoidably imports a large quantity of foreign wood every year (in 1971 import of foreign wood-$3,756,000m^3$, 160,995,000 dollars). So, Korea urgently needs the improvement of forest productive capacity in national forest. But it is difficult that wood production meets the rapid increase of demand for wood to the development of economy, because production term of forestry is long, so national forest management should be rationalized by the effective investment and development of forestry techniques in the long view. Although Korean national forest business has many difficulties in the budget, techniques and the lack of labour due to outflow of rural village labour by development of national economy, and the increase of labour wages and administrative expenses etc. the development of national forest depends on adoption of the suitable forest techniques and management adapted for social and economical development. In this view point the writer has investigated and analyzed the status of the management of national forest in Korea to examine the irrational problems and suggest an improvement plan. The national forestry statistics cited in this study is based on the basic statistics and the statistics of the forest business as of the end of 1971 published by Office of Forestry, Republic of Korea, and the other depended on the data presented by the national forest stations. The writer wants to propose as follows (seemed to be helpful in improvement of Korean national forest management). 1) In the organization of national forest management, more national forest stations should be established to manage intensively, and the staff of working plan officials should be strengthened because of the importance of working plan. 2) By increasing the staff of protection officials, forest area assigned for each protection official should be decreased to 1,000-2,000 ha. 3) The frequent personnel changes of supervisor of national forest station(the responsible person on-the-spot) obstructs to accomplish the consistent management plan. 4) In the working plan drafting for national forest, basic investigations should be carefully practiced with sufficient expenditure and staff not to draft unreal working plan. 5) The area of working-unit should be decreased to less than 2,000 ha on the average for intensive management and the principle of a working-unit in a forest station should be realized as soon as possible. 6) Reforestation on open land should be completed in a short time with a debt of the special fund(a long term loan), and the land on which growing hardwood stands should be changed with conifers to increase productivity per unit area, and at the same time techical utilization method of hardwood should be developed. 7) Expenses of reforestation should be saved by mechanization and use of chemicals for reforestation and tree nursery operation providing against the lack of labour in future. 8) In forest protection, forest fire damage is enormous in comparison with foreign countries, accordingly prevention system and equipment should be improved, and also the minimum necessary budget should be counted up for establishment and manintenance of fire-lines. 9) Manufacture production should be enlarged to systematize protection, processing and circulation of forest business, and, by doing this, mich benefit is naturally given for rural people. 10) Establishment and arrangement of forest road networks and erosion control work are indispensable for the future development of national forest itself and local development. Therefore, these works should be promoted by the responsibility of general accounting instead of special accounting. 11) Mechanization of forest works should be realized for exploiting hinterlands to meet the demand for timber increased and for solving lack of labour, consequently it should promote import of forest machines, home production, training for operaters and careful adminitration. 12) Situation of labour in future will grow worse. Therefore, the countermeasure to maintain forest labourers and pay attention to public welfare facilities and works should be considered. 13) Although the condition of income and expenditure grows worse because of economical change, the regular expenditure should be fixed. So part of the surplus fund, as of the end of 1971, should be established for the fund, and used for enlarging reforestation and forest road networks(preceding investment in national forest).

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF