• Title/Summary/Keyword: facility safety management

Search Result 704, Processing Time 0.031 seconds

The Need for Developiong Scenarios through Social Welfare Facility Evacuation Modeling (사회복지관 피난모델링을 통한 시나리오 개발의 필요성)

  • Jin-Ha Kim;Seo-Young Kim;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.2
    • /
    • pp.29-38
    • /
    • 2023
  • Social welfare facilities are used by a wide range of local residents, including vulnerable populations such as the elderly, children, and people with disabilities. During emergencies like fires, confusion can arise as these individuals try to evacuate. Evacuation simulation results have shown that utilizing evacuation systems based on specific evacuation scenarios can significantly decrease the time required for evacuation compared to general evacuation procedures. By anticipating potential fires based on changes in social and facility environments, appropriate evacuation scenarios can be developed and applied to evacuation systems, thus contributing to the safety and security of individuals during emergencies. In conclusion, for social welfare facilities that serve a large number of people, it is necessary to expand the focus on performance-based design depending on the size of the facility, and to continuously develop and train for appropriate evacuation scenarios that align with changing facility environments.

Development of an Improved Inspection System for Slopes adjacent to Educational Facilities (개선된 교육시설 인접 사면 점검체계 구축)

  • Ko, Jun-Young;Lee, Joon-Kyu;Park, Ku-Byoung;Lee, Byoung-Ho;Kim, Jae-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.28 no.4
    • /
    • pp.3-10
    • /
    • 2021
  • This study presents an improved inspection system for slopes adjacent to educational facilities. For this, field investigations for 5 schools and 3 universities were performed to analyze the engineering stability of infrastructures, which ensure the safety of students and educational officers. Educational laws and the relevant enforcement are reviewed to understand the problems of current laws and enforcement. The results reveal that the engineering measures and reinforcement are required for the slopes of 36%. Also, the improvement of social awareness and regular inspection is needed to maintain the educational infrastructures. The suggested inspection system includes the fundamental and detailed checklists and guidance for non-engineering specialists.

Design of Distribution Facility for Cross Docking Systems (크로스도킹 시스템을 위한 물류센터의 설계에 관한 연구)

  • Yu, Woo-Yeon;Park, Yun-Sun;Shin, Jung-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.2
    • /
    • pp.187-193
    • /
    • 2008
  • Cross docking is a warehouse management concept in which items delivered to a distribution facility by inbound trucks are immediately sorted out and reorganized based on customer demands and are routed and loaded into outbound trucks for delivery to customers without actually being held in inventory in the distribution facility. In this research, the design of distribution facility for cross docking systems was studied. The objective of this research is to find the minimum number of receiving docks and shipping docks, respectively, in order to meet the daily demand of the distribution center. Two solution approaches are employed in modeling and solving the problem The first approach is mathematical modeling and the second approach is a simulation. The logic developed in the simulation model is expected to apply to the real world situation.

A Study on the Facility Eligibility Inspection of National Inpatient Isolation Units (국가지정 입원치료 격리병상 시설적격성 평가분석에 관한 연구)

  • Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.506-514
    • /
    • 2015
  • During the progression of this study, we visited 17 medical institutions. These medical institutions underwent inspection for facility eligibility of national inpatient isolation units to care for patients. Seventeen consultation meetings were held to gather expert opinions, and conferences were held with the medical institutions and local levels of government. Based on these facts, we established a field application model of the criteria of safety-management and conducted a study on this method in order to create more scientific and systematic safety-management criteria including criteria regarding facilities maintenance and methods of equipment inspection. According to an analysis on the 17 medical institutions examined, facility eligibility of 17 national inpatient isolation units was found to be 78.3% on average. Through analysis of the present domestic and foreign conditions of medical institutions, we proposed improvements for when remodeling becomes necessary and established criteria for safety-management in national inpatient isolation units for the care of patients in accordance with the domestic healthcare system.

An unwanted facility location problem with negative influence cost and transportation cost (기피비용과 수송비용을 고려한 기피시설 입지문제)

  • Yang, Byoung-Hak
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • In the location science, environmental effect becomes a new main consideration for site selection. For the unwanted facility location selection, decision makers should consider the cost of resolving the environmental conflict. We introduced the negative influence cost for the facility which was inversely proportional to distance between the facility and residents. An unwanted facility location problem was suggested to minimize the sum of the negative influence cost and the transportation cost. The objective cost function was analyzed as nonlinear type and was neither convex nor concave. Three GRASP (Greedy Randomized adaptive Search Procedure) methods as like Random_GRASP, Epsilon_GRASP and GRID_GRASP were developed to solve the unwanted facility location problem. The Newton's method for nonlinear optimization problem was used for local search in GRASP. Experimental results showed that quality of solution of the GRID_GRASP was better than those of Random_GRASP and Epsilon_GRASP. The calculation time of Random_GRASP and Epsilon_GRASP were faster than that of Grid_GRASP.

INCIDENT FREQUENCY AND SEVERITY FOR CONSTRUCTION FACILITIES

  • Jong-Hyun Park;Jae-Su Jeong;Chan-Sik Lee
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.234-240
    • /
    • 2011
  • Preventing incidents occurred in construction process is important for safe implementation of construction projects. Due to the complexity and magnitude of the project and moreover, poor safe planning and management, construction incidents in Korea have been increasing. Reducing construction incidents effectively, appropriate safety management program in consideration of the incident rate of each facility is to be adapted. This study analyzes incident frequency and severity rate of each facility based on the data of construction sites(about 1,560 thousand cases) recorded by Korea Occupational Safety & Health Agency for 3 years from 2007 to 2009, and the incident related data (about 40 thousand cases) of Korea Workers' Compensation & Welfare Service. The results of this study revealed that construction incident rates of 'cold refrigeration storage facilities' are the highest among building types, followed by traditional building religious building, arcade department store and shopping center. In case of other facilities, the incident rate and the rate of intensity of 'pipelining project' are the highest, followed by 'tunneling project'. These results would be used in providing safety programs beneficial for preventing construction incidents.

  • PDF

Algorithms on layout design for overhead facility (천장형 설비의 배치 설계를 위한 해법의 개발)

  • Yang, Byoung-Hak
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.133-142
    • /
    • 2011
  • Overhead facility design problem(OFDP) is one of the shortest rectilinear flow network problem(SRFNP)[4]. Genetic algorithm(GA), artificial immune system(AIS), population management genetic algorithm (PM) and greedy randomized adaptive search procedures (GRASP) were introduced to solve OFDP. A path matrix formed individual was designed to represent rectilinear path between each facility. An exchange crossover operator and an exchange mutation operator were introduced for OFDP. Computer programs for each algorithm were constructed to evaluate the performance of algorithms. Computation experiments were performed on the quality of solution and calculations time by using randomly generated test problems. The average object value of PM was the best of among four algorithms. The quality of solutions of AIS for the big sized problem were better than those of GA and GRASP. The solution quality of GRASP was the worst among four algorithms. Experimental results showed that the calculations time of GRASP was faster than any other algorithm. GA and PM had shown similar performance on calculation time and the calculation time of AIS was the worst.

A Study on the Consciousness Survey of Geriatric Hospital Workers for Fire Safety (요양병원 종사자의 소방안전 의식조사에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.91-97
    • /
    • 2016
  • Currently many geriatric hospitals have been built in Korea because younger people don't want to care their parents and have been decreasing for labor. However, the increasing geriatric hospitals make the increasing fire safety accidents. Therefore, this study is conducted by survey and face-to-face talk for analyzing fire safety problem of twelve among 15 geriatric hospitals in the north of Chung-Buk area. The result of this study is that infection and fall accident are higher than others and fire safety implement rate of safety rule followed by CEO is 71%. Monthly safety training rate is 49% and initial fire safety training not conducted is 33%. Yearly outside fire safety training rate is 97% but workers who know how to use fire evacuation facility are 61%. Furthermore, safety instruction rate of fire safety manager is much higher than supervisor's safety instruction. The cause of accident is facility (33%). In conclusion, the institution and rule improvement need for decreasing infection and falling, increasing implement level of fire safety rule and fire safety training, participation rate of supervisor for fire safety, quality of fire safety training, and investment of fire safety facility.

Developing organizational system for safety management of sport facilities: Focusing on cases in Japan and Germany

  • Seo, Won-Jae;Park, Seong-Hee;Kim, Nam-Su;Moon, Bo-Ra;Han, Seung-JIn
    • Journal of Sport and Applied Science
    • /
    • v.2 no.1
    • /
    • pp.11-23
    • /
    • 2018
  • In spite of importance of safety issues in community sport, little concerns have been paid to the sport safety policy. Governing bodies and individuals involved with the facility management have a responsibility to manage the risks at acceptable levels. For sports injury prevention interventions, the safety policy of sport facilities should be made to provide a structured framework which can be implemented at community sport. Hence, the current study is to identify the safety issues and to generate the policies that assist to conduct the systematic safety management at sports facilities. For this, the current study analyzed two cases from Japan and Germany. The study reviewed multiple pieces of literature including journal publications, political reports, and media coverage. Through review, the study analyzed the organizational structure, legal systems, and political stance of the safety management of sport facilities in Japan and Germany. The results proposed the following issues. First, law needs to be enacted to establish the control tower where has a responsibility to develop the safety manual and system. Second, local organizations need to be established to educate individuals working in sport facilities and inspect the facilities. Further political issues were discussed for safety management in Korea sport facilities.

A Study of Improving Safety Management in Taekwondo Events (태권도 이벤트의 안전관리 개선 방안)

  • Cho, Hyun-Joo;Kim, Doo-Han
    • Korean Security Journal
    • /
    • no.53
    • /
    • pp.231-251
    • /
    • 2017
  • Taekwondo has developed into a global sport that sports 80 million people from 208 countries around the world. Korea is the mother country of Taekwondo, and there are many international Taekwondo events in Korea. As important as the image of Taekwondo contents, it will be operation plan and management for event facilities. In particular, safety management for participants is more important than anything else. In case of Taekwondo where there are many national events, there are many foreign visitors, so safety management in facilities and running programs needs to be important. In this study, we conducted in - depth interviews with experts with a career in Taekwondo events. Based on the in - depth interviews, we analyzed the safety management problems of the international Taekwondo events and suggested improvement directions to overcome them. Based on the results of these researches, the improvement direction of Taekwondo event safety management proposed in the first category is a demand for improving safety and injury related system construction. The second category, the safety improvement of visitors, is to secure professional manpower and secure budgets. Also, what is important in the third category, facility safety area, is the proposal to introduce facility safety certification system.

  • PDF