• Title/Summary/Keyword: facility safety management

Search Result 706, Processing Time 0.023 seconds

The Assessment of Food Safety Practices and the Effect of Visiting Education on Food Safety Improvement in Children's Foodservice Facilities (어린이 급식소의 위생관리 실태 조사 및 방문지도에 따른 위생관리 개선 효과 분석)

  • Paik, Jae-Eun;Lee, Hyun-A;Bae, Hyun-Joo
    • Korean journal of food and cookery science
    • /
    • v.31 no.6
    • /
    • pp.764-772
    • /
    • 2015
  • This study was conducted to investigate food safety management practices at children's foodservice facilities and evaluate the effect of visiting education by Center for Child-care Foodservice Management (CCFSM) for food safety improvement. The subjects of evaluation included child care centers (84.3%), kindergartens (7.8%), and community child centers (7.8%). Facilities by foundation types were private (70.6%), public (19.6%), and corporation (9.8%). The average score of food safety evaluation was 84.09 points. The total score of food safety evaluation of community child center was significantly lower than that of child care center and kindergarten (p<0.01); and the total score of public facilities was higher than that of private facilities. Furthermore, 35.9% of evaluation items showed performance higher than 90%, while 15.4% showed performance less than 60%. The item with lowest performance was 'washing and disinfection of fruits and vegetables (26.5%)'. Results of one-way ANOVA of food safety evaluation score by the frequency of visiting education indicated that the evaluation score of the third session significantly increased from the first and second sessions. In addition, the result of two-way ANOVA showed that both foodservice type (F=21.730, p<0.001) and the frequency of visiting education (F=7.968, p<0.001), and both foundation type (F=31.387, p<0.001) and the frequency of visiting education (F=7.507, p<0.001) affected the total food safety evaluation score. There were significant differences in result scores according to the number of meal served (F=17.133, p<0.001) and the frequency of food safety evaluation (F=17.065, p<0.001). In conclusion, visiting education of children's foodservice facility showed significant effect on the improvement of food safety level.

Case Study : Application of Specific Evaluation Criteria For Safety Circuit Design of EN ISO 13849-1 (사례 연구 : EN ISO 13849-1의 안전회로 설계를 위한 구체적 평가 기준의 적용)

  • Jung, Hwansuk;Lee, Dongju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.1
    • /
    • pp.94-101
    • /
    • 2018
  • With the development of industrial technology and science, production and manufacturing facilities have been enhanced and improved, and the importance of the safety of workers has also been regulated and limited by various safety management methods. As a way to secure the safety of the workers from the production facility, the fail-safe and fool-proof methods are now being applied. Any possible insecure behavior and unsafe conditions can be removed by adopting the standards and specifications that are now secure the safety of workers and equipment. This research analyzes EN ISO 13849-1 international and European standards during CE certification. In order to secure acceptable reduced risks, the risk assessment process of ISO 12100 and the processes for reducing its risk are applied. In the current ISO 13849-1 standard, the criteria for the required performance level PLr (Required Performance Level) for the applicable risk and safety functions through the risk assessment are subjective and not subdivided. Therefore, the evaluation criteria are likely to cause judge's judgement error due to qualitative judgement. This research focuses on evaluation and acceptable performance level setting for the safety circuit of the equipment. We propose an objective and specific evaluation criteria to secure safety, and the proposed evaluation criteria are applied to the case study of the safety circuit for the equipment. In order to secure the safety of the entire safety circuit, the improvement of the MTTFd and DC level related to the SRP/CS (Safety-Related Parts of Control Systems)' lifetime is required for the future research.

A Study on the Management and Dispensing Standards of Herbal Medicine in Herbal Dispensaries (탕전실의 조제 관리 및 운영 기준에 대한 연구)

  • Kang, Sung Chul;Kim, So Yeon;Yun, Yu Kyung;Kim, Ji-Hoon;Kim, Yun-Kyung
    • Herbal Formula Science
    • /
    • v.27 no.1
    • /
    • pp.31-44
    • /
    • 2019
  • Objective : Herbal dispensaries, where medications are prepared for patients, require specific preparation and operations management for safe herbal medicines. This study aims to propose improvements in the herbal medicine preparation and operation of the herbal dispensaries as series study of the "A Survey on the Management Status of Extramural Herbal Dispensaries" Methods : We first checked current management regulations. In addition, we compared and analyzed related laws which are "State management norm of Traditional Chinese Medicine dispensaries", "Enforcement Rule of Medicinal Product Safety" and " Hazard Analysis and Critical Control Point(HACCP)", to introduce the assessment items of herbal dispenses evaluation and certification system. Results : In this study, we found that the current regulations, "Guideline on Installation and Utilization of Extremal Herbal Pharmaceutical Facility and Shared-use of Herbal Dispensary", are insufficient to ensure the quality and safety of herbal medicines. We suggested articles for the proper management of herbal dispensaries and these were introduced to the Herbal dispensary evaluation and certification system. Conclusion : We recommend evaluation articles in Herbal dispensary evaluation and certification systems need to be popular among herbal dispensaries, then Korean herbal medicine could restore credibility from the people.

A Study on the Implement of AI-based Integrated Smart Fire Safety (ISFS) System in Public Facility

  • Myung Sik Lee;Pill Sun Seo
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.225-234
    • /
    • 2023
  • Even at this point in the era of digital transformation, we are still facing many problems in the safety sector that cannot prevent the occurrence or spread of human casualties. When you are in an unexpected emergency, it is often difficult to respond only with human physical ability. Human casualties continue to occur at construction sites, manufacturing plants, and multi-use facilities used by many people in everyday life. If you encounter a situation where normal judgment is impossible in the event of an emergency at a life site where there are still many safety blind spots, it is difficult to cope with the existing manual guidance method. New variable guidance technology, which combines artificial intelligence and digital twin, can make it possible to prevent casualties by processing large amounts of data needed to derive appropriate countermeasures in real time beyond identifying what safety accidents occurred in unexpected crisis situations. When a simple control method that divides and monitors several CCTVs is digitally converted and combined with artificial intelligence and 3D digital twin control technology, intelligence augmentation (IA) effect can be achieved that strengthens the safety decision-making ability required in real time. With the enforcement of the Serious Disaster Enterprise Punishment Act, the importance of distributing a smart location guidance system that urgently solves the decision-making delay that occurs in safety accidents at various industrial sites and strengthens the real-time decision-making ability of field workers and managers is highlighted. The smart location guidance system that combines artificial intelligence and digital twin consists of AIoT HW equipment, wireless communication NW equipment, and intelligent SW platform. The intelligent SW platform consists of Builder that supports digital twin modeling, Watch that meets real-time control based on synchronization between real objects and digital twin models, and Simulator that supports the development and verification of various safety management scenarios using intelligent agents. The smart location guidance system provides on-site monitoring using IoT equipment, CCTV-linked intelligent image analysis, intelligent operating procedures that support workflow modeling to immediately reflect the needs of the site, situational location guidance, and digital twin virtual fencing access control technology. This paper examines the limitations of traditional fixed passive guidance methods, analyzes global technology development trends to overcome them, identifies the digital transformation properties required to switch to intelligent variable smart location guidance methods, explains the characteristics and components of AI-based public facility smart fire safety integrated system (ISFS).

A Study on the Safety of Electromagnetic Wave of Medical Imaging System (의료영상장치의 전자파 안전에 대한 연구)

  • Seon, Jong-Ryul;Lee, Won-Jeong;Rhim, Jae-Dong
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.103-112
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system ($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

  • PDF

A Study of Emergency Plan Making Programs for Personnel Handling Accident Precaution Chemicals (사고대비물질 취급자를 위한 비상대응계획 작성 프로그램 연구)

  • Kim, Sung Bum;Cho, Mun Sik;Park, Choon Hwa;Yoon, Yi;Hwang, Kyung Sup;Yang, Sang Yong
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.27-32
    • /
    • 2010
  • Emergency preparedness plan (EPP) is the systematic management of activities that involve a material degree of risk of loss or other damage to the surroundings (people, property and environment), and the boundary of accident recovery plan (ARP). The main purpose of the program is to provide a safety management system to each facility in order to enable to prevent accident and to control accident immediately. The EPP includes not only typical safety-related documentations such as material safety data sheet (MSDS), standard operation procedure (SOP), emergency response plan(ERP). EPP is established basis of the preliminary safety analysis involving risk identification, assessment and prevention plans. The program is also helpful for government or related agencies to control a number of accidents in small-scale companies in the whole country.

  • PDF

A Study on the Emission Changes in Reduction Chemical Substances in Korea (유해화학물질 배출량 변화에 관한 연구: 배출저감계획서 작성 대상물질 중심으로)

  • Im, JiYoung;Lee, MyeongJi;Kim, HyunJi;Ryu, JiSung;Yun, DaeSik;Jang, YongChul;Lee, ChungSoo
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.159-169
    • /
    • 2020
  • Objectives: The purpose of this study was to investigate changes among the nine kinds of reduction chemical substances in Korea over the period of 2008-2017. We will define basic data for improving the management methods for reducing chemical substances. Methods: A survey of hazardous pollutant emissions for 2008-2017 was conducted through the pollutant Release and Transfer Register homepage. Nine kinds of designated reduction chemical substances (Benzene, Vinyl chloride, Trichloro ethylene, 1,3-butadiene, Dichloro methane, Tetrachloro ethylene, N,N-dimethylformamide, Acrylo nitrile, and Chloroform) provided the study subjects. The emission of hazardous chemicals and health effects used the National Health Statistics and Integrated Chemicals Information System (ICIS) as a reference. Results: Hazardous pollutant emissions increased by 1.2 times over the past decade, and nine types of reduction chemical substances increased by 1.6 times. By region, the emissions of reduction chemical substances over the last 10 years were in the order of Chungbuk, Gyeonggi, and Gyeongbuk. Emissions of Dichloro methane was the highest in Chungbuk and Gyeongbuk. N,N-dimethylformamide was the highest in Gyeonggi. Carcinogen pollutant emissions showed a tendency to increase continuously. In addition, group 1 carcinogen emissions showed a tendency to decrease. Conclusion: In the last decade, the amount of hazardous chemical emissions has been continuously increasing. Hazardous chemical emissions require facility improvement for continuous emissions reduction. More research on reduction of emissions is needed.

A Study on the Safety of Electromagnetic Wave of Medical Imaging System (의료영상장치의 전자파 안전에 대한 연구)

  • Seon, Jong-Ryul;Lee, Won-Jeong;Rhim, Jae-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

A Study on Collection Efficiency And Economy of Total Hydrocarbons in Accordance with Time Changes at Activated Carbon Collection Facility (활성탄집진시설의 시간변화에 따른 총탄화수소의 집진효율성 및 경제성에 관한 연구)

  • Kim, Seong Jung;Han, Dae Hee;Woo, In Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.231-236
    • /
    • 2014
  • In this study, the changes in collection efficiencies due to the time changes of activated carbons were ascertained, and in order to identify the magnitude of adsorption, the before-use and after-use iodine adsorption values were analyzed. In addition, as a result of examining the characteristics of continuous process and non-continuous process and as a result of investigating whether the emission standards would be maintained, the continuous process and printing facilities were seen as not being able to maintain the emission standards. Also were found, in the case of non-continuous process,-taking into consideration the special nature of the job -for 4${\o}$ palletized charcoal, a collection efficiency near 50% was shown even after 96 hours. Also, when the inlet concentration was about 300ppm, it is thought that the emission standards would be maintained if the activated carbons are replaced within at least 96 hours in the case of 4${\o}$ palletized charcoal and the use was deemed pointless in the case of carbon. The results of this study are expected to provide assistance in selecting replacement periods for activated carbons and in selecting absorbents at the project sites, and are expected to be of significant help in the selection of precipitators that can collect total hydrocarbons for compliance of the emission standards.

Development of Message Broker-Based Real-Time Control Method for Road Traffic Safety Facilities Equipment and Devices Integrated Management System

  • JeongHo Kho;Eum Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.1
    • /
    • pp.195-209
    • /
    • 2024
  • The current road traffic signal controller developed in the 1990s has limitations in flexibility and scalability due to power supply problems, various communication methods, and hierarchical black box structures for various equipment and devices installed to improve traffic safety for road users and autonomous cooperative driving. In this paper, we designed a road traffic safety facilities equipment and devices integrated management system that can cope with the rapidly changing future traffic environment by solving the using direct current(DC) and power supply problem through the power over ethernet(PoE) technology and centralized data-driven control through message broker technology. In addition, a data-driven real-time control method for road traffic safety facilities equipment and devices operating based on time series data was implemented and verified.