• Title/Summary/Keyword: facility safety management

Search Result 706, Processing Time 0.025 seconds

A Study on the Effective Maintenance Method of the Stair Passage Leading Light installed In the Shopping Building (상가건물 계단통로유도등의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This study was conducted by survey and inspection of stair passage leading lights in shopping buildings which are more than 5 stories and have an underground parking lot located at Pyeongtaek-si and Seongnam-si. Number of shopping building for this study is 30 and of stair passage leading light inspected by two lights in each shopping building is 60. The result of this study is that the type of installed leading lights is LED(77%), and 60% of leading lights has problem such as no cleaning, scratch and discoloration, etc. The height of installed leading lights meets the fire law which is less than 1m from the floor. Visible condition of leading lights is good except some leading lights which have a little visible problem due to banner advertisement. 37% of standby power has flickered and went out. 93% of total leading lights meets the fire law which is more than 1lux from 0.5m distance, but cold cathode fluorescent lamps(CCFLs) have the problem which not meets proper brightness level based on fire law. In additional measurement result, zero lux of leading lights is 32%(from 1m distance), 68%(from 1.5m distance) and 98%(from 2m distance). Leading light is very important facility because it is eyes and guide when emergency. Therefore, proper fire facility operating function inspection and total detailed inspection are important to keep the good condition of leading light except simple visual check, and also improvement in law system of type approval, fire construction inspection and illumination level will be needed.

A Study on Requirements of ISPS Code - By Comparative Analysis of ISO 9001 and ISM Code - (ISPS Code의 요건에 관한 연구 - ISO 9001 및 ISM Code와의 비교분석을 통해 -)

  • 조동오;이영선
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.9 no.1
    • /
    • pp.25-31
    • /
    • 2003
  • In 1994, the International Maritime Organization (IMO) adopted the International Safety Management Code (ISM Code) as SOLAS convention to ensure the safe operation of ships and to protect marine environment from pollution In December 2002, the IMO adopted the International Ship and Port Facility Security Code (ISPS Code) in the Chapter XI-1 of SOLAS to ensure the security of ships, crew, cargo and port facility. With 1 July 2004 being the coming into effective date of ISPS Code, there is a sense of urgency among the shipping companies and port authorities to accomodate the ISPS Code. Although both the ISM Code and the ISPS Code are based on the management system concept introduced in the ISO 9001, two Codes pursue different objective. Accordingly, it is meaningful to compare and analyze the requirements of three standards. In this article, the backgrounds, principles and requirements of three standards are analyzed and presented to offer several suggestions on the establishment and implementation of security measures in compliance with the ISPS Code to the shipping industry in time.

  • PDF

A Method for Operational Safety Assessment of a Deep Geological Repository for Spent Fuels

  • Jeong, Jongtae;Cho, Dong-Keun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.spc
    • /
    • pp.63-74
    • /
    • 2020
  • The operational safety assessment is an important part of a safety case for the deep geological repository of spent fuels. It consists of different stages such as the identification of initiating events, event tree analysis, fault tree analysis, and evaluation of exposure doses to the public and radiation workers. This study develops a probabilistic safety assessment method for the operational safety assessment and establishes an assessment framework. For the event and fault tree analyses, we propose the advanced information management system for probabilistic safety assessment (AIMS-PSA Manager). In addition, we propose the Radiological Safety Analysis Computer (RSAC) program to evaluate exposure doses to the public and radiation workers. Furthermore, we check the applicability of the assessment framework with respect to drop accidents of a spent fuel assembly arising out of crane failure, at the surface facility of the KRS+ (KAERI Reference disposal System for SNFs). The methods and tools established through this study can be used for the development of a safety case for the KRS+ system as well as for the design modification and the operational safety assessment of the KRS+ system.

A Study on Facilites Safety of Long-Term Care Facilities for Elderly :Focused on the Factual Survey of Seoul Metropolitan Area (장기요양시설의 노인보호를 위한 시설안전에 관한 연구 : 수도권 시설안전 실태조사를 중심으로)

  • Moon, Yongpil
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.10
    • /
    • pp.308-325
    • /
    • 2020
  • This study examines factual facilites safety of long-term care facilities for eldery, for improvement of Korean policy. So, This study reviewed policies of facilites safety of long-term care facilities on main OECD countries. We analyzed factual survey of facilites safety of long-term care facilities in Seoul metropolitan area. The results of the study were as follows: First, There were differences of law and rule of facilites safety of long-term care facilities in comparison with those of social welfare facilities, child day-care center, hospital. Second, it was the result of location condition analysis. Long-term care facilities in the Seoul metropolitan area were located on more than six floors of buildings. The location conditions of private facilities are weak compared to those of corporations and local governments. Third, there were the result of internal structure of facilities. Overall, the placement status was insufficient. For instance, there are smokeproof masks/fireproof blankets, smoke windows(fire safety windows), smoke smothering. In addition, there were places where legal essential installation structures were insufficient. Private facilities were generally insufficient in facility structures compared to those of local governments and welfare corporations. Fourth, there were the result of safety management. It was confirmed that private facilities were insufficient compared to local government facilities. For instance, there are safety management analysis, response manuals, fire preparedness training, etc. Finally, implications and future directions policies of facilites safety of long-term care facilities were discussed based on the finding of the study.

A Study on the safety measures for hydrogen cooling system of 500MW class thermal power plant (500MW급 화력발전소 수소냉각시스템의 안전대책)

  • Kim, Soon-Gi;Yuk, Hyun-Dai;Ka, Chool-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.385-390
    • /
    • 2005
  • This paper provided a counter measures against the troubles and accidents that are likely to take place in the power plant using hydrogen gas as a coolant for the cooling system of the generator. Because of the extremely wide flammability limits of hydrogen in comparison to the other flammable gases, the safety measures against the hydrogen accidents is very important to ensure the normal operation of electric-power facility. This study's purpose was a presentation of standard model of safety management of hydrogen equipments in the coal firing power plant such as following items: 1) providing the technical prevention manual of the hydrogen explosions and hydrogen fires occurring in the cooling system of power generator; 2) the selection of explosion-proof equipments in terms of the risk level of operating environment; 3) the establishment of regulations and counter measures, such as the incorporation of gas leakage alarm device, for preventing the accidents from arising; 4) the establishment of safety management system to ensure the normal operation of the power plant.

  • PDF

Decision Making of Seismic Performance Management Using Seismic Risk Assessment (지진위험도평가 방법을 이용한 내진성능관리 의사결정)

  • Kim, Dong Joo;Choi, Ji Hye;Kim, Byeong Hwa
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.6
    • /
    • pp.329-339
    • /
    • 2019
  • The strategy for the management of earthquakes is shifting from post recovery to prevention; therefore, seismic performance management requires quantitative predictions of damage and the establishment of strategies for initial responses to earthquakes. Currently, seismic performance evaluation for seismic management in Korea consists of two stages: preliminary evaluation and detailed evaluation. Also, the priority of seismic performance management is determined in accordance with the preliminary evaluation. As a deterministic method, preliminary evaluation quantifies the physical condition and socio-economic importance of a facility by various predetermined indices, and the priority is decided by the relative value of the indices; however, with the deterministic method it is difficult to consider any uncertainty related to the return-year, epicenter, and propagation of seismic energy. Also this method cannot support tasks such as quantitative socio-economic damage and the provision of data for initial responses to earthquakes. Moreover, indirect damage is often greater than direct damage; therefore, a method to quantify damage is needed to enhance accuracy. In this paper, a Seismic Risk Assessment is used to quantify the cost of damage of road facilities in Pohang city and to support decision making.

A Field Survey on Facility Management and Anglers' Requirements at Recreational Sea-fishing Parks (바다낚시공원 시설운영 및 낚시인 요구사항 조사 연구)

  • Kang, Young-Hun;Hong, Sung-Ki;Lee, Han-Seok
    • Journal of Navigation and Port Research
    • /
    • v.39 no.6
    • /
    • pp.529-538
    • /
    • 2015
  • This paper was intended to empirically identify problems with recreational sea fishing park facilities installed to help reinvigorate local economy of fishing villages in order to mitigate shortage of fishing facilities amid an increase in sea fishers and spur evolution of sea fishing into a marine leisure activity, on which basis this researcher presented direction for facility planning which is deemed necessary to map out the plan for sea fishing parks, along with measures designed to improve sea fishing park facilities. To analyze the problems related to sea fishing park facilities, we conducted a survey on facility operations involving 9 sea fishing parks and 2 sea ranches and had an investigative interview with facility manager. Moreover, a survey was conducted of fishers in 25 sea fishing places, including sea fishing park, fishing experience village, etc., in order to investigate their demand for facilities. The results of survey suggested that there was a significant demand for expansion of amenities such as safety facilities, toilets, lounge facilities, etc., which can accommodate the increase in the number of people fishing with family. Furthermore, the results showed that there was a huge demand for introduction of facilities aiding leisure activities in addition to facilities for fishing activities including education facilities such as fishing site at the corner exclusive for beginners, experiential facilities, camping site, seaside park, promenade, etc. Thus, sea fishing park should be the complex leisure space with a focus on fishing activities and requires facility configuration and facility planning suited to activity requirements within fishing park.

Building Facilities Management Using the Condition Prediction Process: A Case Study of Fiberglass Doors

  • Amani, Nima
    • Journal of Construction Engineering and Project Management
    • /
    • v.4 no.3
    • /
    • pp.47-52
    • /
    • 2014
  • In the last decades, Facility Management (FM) has established itself as a key building service factor.FM includes supporting services and organizing functions essential for maintaining, operating and managing physical component and material. The purpose of the paper is to develop an economical analysis for building facilities management during its service life based on limited cost. This method helps to facilities managers and engineers to make better decisions for reducing of facilities assessment costs and increasing the facilities' service life. This paper presents the preliminary development of a model involves three stages process namely data collection, economic computation and economic process optimization. This process was tested for fiberglass doors example in a building interior and exterior system. If executives can manage essential points effectively and make decisions according to a key performance index, cost can be optimized and safety can be enhanced for installation building.

Analysis of the Finishing Failure in the Railway Station Platform and Deduction of Improvement Plans (철도역사 승강장 연단부 마감 탈락에 대한 원인 분석 및 개선 방안)

  • Ko, Sewon;Yu, Youngsu;Koo, Bonsang;Kim, Jihwan
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.1
    • /
    • pp.46-53
    • /
    • 2022
  • The railway platform is an important facility closely related to the safety of passengers, trains, and images of railway facilities, and requires thorough facility management. However, the problem that the finishing material (plastering mortar) for the joint finishing of dissimilar materials (concrete+granite) falls off in the direction of the track at the platform podium is occurring multiple times across the country. Since these problems threaten the safety of train operation and the safety of passengers, immediate and continuous management is required. This study tried to derive improvement plans through the analysis of the drop-off problem of finishing materials occurring at the platform podium. The status of missing finishing materials for the platform podiums of about 200 railway stations and the related design and construction standards of the Korea National Railway were investigated. After that, the cause of the drop-off of the finishing material was analyzed, and as a result, it was found that the main cause was the boundary between the roadbed and the architectural process that occurred during construction. Subsequently, in connection with the derived causes and design, construction standards, (1) improvement of finishing materials or construction methods, (2) design of finishing materials that are easy to adjust height, (3) design of separate finishing methods, (4) improvement methods and durability were suggested.

A Study on the Processing Method of Reliability Database using 2-Bayes Theory (2-Bayes 이론을 이용한 데이터 처리방법에 관한 연구)

  • Lee, M.S.;Rhie, K.W.;Kim, T.H.;Yoon, I.K.;Oh, Y.D.;Seo, D.H.
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.144-149
    • /
    • 2009
  • The safety assessment for facility industry is now being periodically performed in Korea. For the purpose of scientific safety management, QRA(Quantitative Risk Assessment) is also being performed, and reliability data of the facilities is essential to perform the assessment. The necessary reliability data for QRA have been generally announced the values in other process industries, which results in the drop of risk reliability. The most appropriate method is to perform a direct reliability analysis towards the facilities undergoing safety assessment. In this study, the distinction between homogeneous sample estimation and multi-sample estimation of reliability data clarify using 2-Bayes theory.