• Title/Summary/Keyword: facility guidelines

Search Result 350, Processing Time 0.023 seconds

A Study on the Area Composition Analysis of the National Designated Isolation Unit Wards(NDIUs) - Focused on the NDIU wards issued in 2016 (국가지정입원격리병상의 시설별 면적구성에 관한 연구 - 2016년 국가지정입원격리병상 확충사업대상을 중심으로)

  • Yoon, Hyung Jin;Kwon, Soon Jung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.2
    • /
    • pp.73-82
    • /
    • 2017
  • Purpose: Since the facility guidelines for National Designated Isolation Unit wards(NDIUs) had been edited since 2016, all hospital who want to expand or install NDIU should adapt the new guidelines. Instead of providing area requirement, by the way, only essential or optional facility requirements are suggested except patient bedroom in the guidelines. So, as analyze area and area composition of the NDIUs, it could be expected that this study has a role as an area planing reference for not only NDIU but also another airborne infection isolation room. Methods: For the area analysis, 18 sample hospitals are selected among 2016 year applicants. All rooms in NDIUs are grouped as zones whether those are negative air pressurized or not and programed room or not. At the end, area of the zones are summarized and analysed a relationship between area increase and bed number by both correlation analysis and regression analysis. In addition, department usable and gross area per bed, N/G ratio, G/N ratio, and average area ratio of each zone is calculated. Results: First of all, rooms in none negative air pressurized zone of the NDIUs haven't shown a regular installation so that only those in negative air pressurized zone are targeted for the area analysis. Second of all, patient room unit(0.92) and support area(0.79), by correlation analysis, are correlated with total net area. Patient room unit(0.94) and total net area(0.79) are also shown a correlation with bed number. Department usable area($R^2=0.63$, y=36.278x + 102) and patient room unit area($R^2=0.89$, y= 27.993x - 0.8924) has a relationship with bed number by regression analysis. Average N/G is shown as 0.85 and G/N 1.36. Average area ratio of circulation, doffing area, patient room unit, and support area are 25.4%, 9.1%, 50.9%, and 14.6% in order. Implications: This study is a basic research for exploring the NDIUs guidelines to find resonable evidence to develop it for its practical use. Still, it is possibly expected that the guideline is to be developed by post occupancy evaluation in the area of where minimum requirement or facility grade needs to be defined, and by further studies with various perspectives.

A Study on the Facility Utilization and the Residents¡?Cognition of Public Open Spaces in Apartment Housing (아파트 옥외공유공간의 이용실태에 관한 조사연구)

  • 최상호;석호태
    • Journal of the Korean housing association
    • /
    • v.13 no.3
    • /
    • pp.93-101
    • /
    • 2002
  • The goal of this survey is to propose planning and design informations for the public open spaces in apartment housing, through the observation and analysis of the current situations. For this, the planning information of housing suppliers about public open spaces and the spatial utilization of users were compared and by analyzing facility utilization and resident\`s recognition. This study is also intended to guide the future directions of the research for the improvement of public open spaces. The research follows three phases; \circled1 To understand the conditions of public open spaces in apartment housing sites through survey and analysis of catalogues and references. \circled2 To study on facility utilization and resident's recognition by observation and analysis. \circled3 To propose planning guidelines for the improvement of public open space by recognition differences of facilities.

Development of classification criteria for non-reactor nuclear facilities in Korea

  • Dong-Jin Kim;Byung-Sik Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.792-799
    • /
    • 2023
  • Non-reactor nuclear facilities are increasing remarkably in Korea combined with advanced technologies such as life and space engineering, and the diversification of the nuclear industry. However, the absence of a basic classification guideline related to the design of non-reactor nuclear facilities has created confusion whenever related projects are carried out. In this paper, related domestic and international technical guidelines are reviewed to present the classification criteria of non-reactor nuclear facilities in Korea. Based on these criteria, the classification of structures, systems and components (SSCs) for safety controls is presented. Using the presented classification criteria, classification of a hot cell facility, a representative non-reactor nuclear facility, was performed. As a result of the classification, the hot cell facility is classified as the hazard category 3, accordingly, the safety class was classified as non-nuclear safety, the seismic category as non-seismic (RW-IIb), and the quality class as manufacturers' standards (S).

A Study on the Service Facilities Plan for APT Community Culture Activation (공동체 문화 활성화를 위한 APT단지 부대복리시설 계획에 관한 연구)

  • Lee, Gwang-Young;Cho, Jin-Man
    • Journal of the Korean housing association
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2008
  • This study is researched to provide design guidelines of service facilities and programs that apartment residents want along with the increased quality of life. This study is signifiant because it sought effective methods to activate the com-munity culture through service facilities in apartment complexes and the design standard and planning direction for residents. The study results are as follows. In the result of the correlations analysis and multiple regression analysis for the importancy of service facilities in apartment complexes, the following orders were considered as important factor; man-ager office, open space, resident community facility, elderly people meeting and activity facility, walking paths, resident athletic facility, a children's playground, library, and rest areas in the complex. and result of the correlations analysis and multiple regression analysis is the following: service facilities whole importance (y) = 1.413$+0.262^*{\times}1$ (manager office importance)$+0.271^*{\times}2$ (open space importance) $+0.185^*{\times}3$ (resident community facility importance) $+0.136{\times}4$ (elderly people meeting and activity facility importance)$+0.036^*{\times}5$ (walking paths importance) $+0.031^*{\times}6$ (resident athletic facility importance) + $(-0.042)^*{\times}7$ (a children's playground importance) + $(-0.045)^*{\times}8$ (library importance) + $(-0.0097)^*{\times}9$ (rest areas importance).

A study on the space composition and area planning of neonatal intensive care unit through the case of regional neonatal intensive care centers (신생아 집중치료 지역센터 사례를 통해 본 신생아 집중치료실(NICU) 공간 구성 및 면적 계획에 관한 연구)

  • Lee, Kee hwan;Park, Seo won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.1
    • /
    • pp.7-17
    • /
    • 2024
  • Purpose: This study is to present basic data and standards for calculating the space composition and area required when planning a neonatal intensive care unit. Methods: Review domestic and foreign facility standards and regulations related to the current neonatal intensive care unit, select a regional neonatal intensive care center designated by the Ministry of Health and Welfare as a case hospital, and organize a space program for the construction plan of the neonatal intensive care unit through analysis of characteristics such as facility size and function composition. Results and Implications: The size, facility area, and detailed room composition characteristics of the neonatal intensive care unit in Korea were confirmed, and essential rooms and appropriate areas were derived when planning the construction of the neonatal intensive care unit. Korea's legal facility standards related to neonatal intensive care units are lower than the actual hospital status and overseas standards, and the facility standards of the medical law need to be improved.

A Study on the Trend of Library Services in Foreign Correctional Facilities (외국 교정시설도서관 서비스 동향에 관한 연구)

  • Hyojung Sim
    • Journal of Korean Library and Information Science Society
    • /
    • v.54 no.1
    • /
    • pp.91-114
    • /
    • 2023
  • This study increases awareness of the survey and demand for libraries in correctional facilities, which have not received much attention so far, and is necessary for improving the operation of existing research and libraries in Korea, which is conducting a current status survey of most correctional facility libraries. The contents of the service operation of the external correctional facility library were explored and analyzed. As a result of the analysis, the United States, the United Kingdom, and Germany, where correctional facility libraries are relatively well operated, are practically operating social rehabilitation programs while reducing recidivism of inmates, and library associations or local governments in each country are promoting the vitalization of correctional facility libraries. It helps and organizes committees or organizations involving related experts to discuss policy support, issue checks, research, report publication, drafting and revising guide guidelines, cooperation between libraries, and reflect them in actual operation. In addition, it maintains steady support and interest through public-private cooperation, and makes good use of the linkage system with local public libraries. As a result, it contributes to reducing the recidivism of prisoners. Through this study, the following three areas were suggested for the administrative improvement direction for correctional facility library services. First, the production and distribution of guidelines or guidebooks for correctional facility libraries, second, the establishment of a specialized correctional facility library organization within the correctional headquarters or library association, and third, the strengthening of activities and the operation of law libraries in correctional facilities.

A Study of the Installation Regulation and Condition about a Bicycle Parking Facility of Buildings (건축물의 용도별 자전거주차장 설치기준 및 실태에 관한 연구)

  • Lee, Sung Ok;Kim, Soo Am
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.73-80
    • /
    • 2009
  • The purpose of this paper is to suggest rules and regulations about a bike parking facility, With the objective of expanding bike parking facilities for the comfort of bikers. In Korea, the requirements to establish the facility comply with several regulations like laws for the encouragement of bike usages, rules and regulations for the encouragement of bike usages, regulations of Gyeonggi Regional Corporation rules and Korea National Housing Corporation(Korea Land and Housing Corporation) and requirements for the approval of green buildings. Such rules regulate the number of parking spots depending on the number of nearby houses and the size of a parking facility. Amongst the foreign regulations about the facility is 'obligatory regulations for the establishment of a bike parking facility' in Japan. In the United States, all states apply rules about the bike facility to determine the number of bike parking spots in accordance with the number of car parking spots. Comparing Korean rules regarding the bike parking facility with those of foreign governments will give a good insight into the current situation of Korean regulations. In order to investigate the current usage of bikes, 30 houses in Goyang city, 35 schools, 16 retails shops and 20 medical centers were researched. Thereafter, a correlation test between the size of buildings and the number of bike parking spots was carried out. The result of the test indicates that there is a lack of space for bike parking. It is recommended that the bike parking facility be installed with a convenient access to a building in order to increase the rate of bike usages.

Research on the Design Guidelines and Implementations of Barrier-free Space for Children - Focused on the Common Spaces of the Outpatient Clinics in Pediatric Rehabilitation Hospitals - (어린이를 고려한 무장애공간 계획기준 및 적용실태 연구 - 어린이 재활병원의 외래부 공용공간을 중심으로 -)

  • Cho, Min-Jung
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.4
    • /
    • pp.113-124
    • /
    • 2016
  • This research examines domestic and oversea's barrier-free design guidelines provided exclusively for children and their implementations in the common spaces of the outpatient clinics in two pediatric rehabilitation hospitals in Seoul. Based on literature review, a checklist was developed to compare various barrier-free design guidelines in consideration of children's accessibility in space. In addition, four spatial areas in the outpatient clinics of the two hospitals were investigated based on the checklist. As a result, the domestic and Japanese guidelines were aiming primarily to all user groups regardless of ages. Whereas in other oversea's guidelines, a number of barrier-free design standards exclusive for children were found in the facility items such as handrail, sink, urine, toilet, water fountain, chair, table, shelve, and so on, throughout the indoor waiting and sanitary spaces. Concerning implementations, most of the items in the indoor passage, waiting, and sanitary spaces of the two hospitals were not sufficiently facilitated enough to meet with the barrier-free design standards exclusive for children. As such, it is recommended to review and improve the current domestic barrier-free design guideline to accommodate various physical and spatial needs of children in all age groups and regardless of disability types, in the design of a pediatric rehabilitation hospital in the future.

Towards guidelines for design of loose-laid roof pavers for wind uplift

  • Mooneghi, Maryam Asghari;Irwin, Peter;Chowdhury, Arindam Gan
    • Wind and Structures
    • /
    • v.22 no.2
    • /
    • pp.133-160
    • /
    • 2016
  • Hurricanes are among the most costly natural hazards to impact buildings in coastal regions. Building roofs are designed using the wind load provisions of building codes and standards and, in the case of large buildings, wind tunnel tests. Wind permeable roof claddings like roof pavers are not well dealt with in many existing building codes and standards. The objective of this paper is to develop simple guidance in code format for design of loose-laid roof pavers. Large-scale experiments were performed to investigate the wind loading on concrete roof pavers on the flat roof of a low-rise building in Wall of Wind, a large-scale hurricane testing facility at Florida International University. They included wind blow-off tests and pressure measurements on the top and bottom surfaces of pavers. Based on the experimental results simplified guidelines are developed for design of loose-laid roof pavers against wind uplift. The guidelines are formatted so that use can be made of the existing information in codes and standards such as American Society of Civil Engineering (ASCE) 7-10 standard's pressure coefficients for components and cladding. The effects of the pavers' edge-gap to spacer height ratio and parapet height to building height ratio are included in the guidelines as adjustment factors.

Development and Utilization of Guidelines for Customized Hygiene Management of Children's Meal Facilities (어린이 급식시설 맞춤형 위생관리 지도서의 개발과 활용)

  • Choi, Kyunga;Lee, Sunghyun;Park, Hyekyung
    • Journal of the FoodService Safety
    • /
    • v.2 no.1
    • /
    • pp.36-43
    • /
    • 2021
  • The development of food poisoning prevention guidelines aims to prevent food poisoning in advance and improve the safety of children's meals through hygiene management of children's feeding facilities, especially infants' facilities. Therefore, the composition of the content should be designed so that it can be fully understood from the point of view of the layperson. In terms of meal service management, various standards must be fully reflected and reviewed to increase utilization in the field. Daycare centers and kindergartens have different administrative agencies, similar application laws and guidelines, but different parts exist and various types of facilities, so management standards are often ambiguous. Therefore, such management requires easy guidance, not special guidance, and it should be universally applicable to any facility. Prior studies have shown that the management of meal facilities is the most efficient, but it is difficult to hire and deploy specialists due to the operation of children's meal facilities, so guidance, facilities managers and workers need to voluntarily practice them. It is time to prepare hygiene guidelines that reflect the characteristics of these children's cafeterias, and it is necessary to prepare and utilize guidance suitable for reality until it is institutionalized for the deployment of manpower exclusively for meals.