• Title/Summary/Keyword: facility disaster

Search Result 409, Processing Time 0.025 seconds

A Study on the Actual Condition Analysis and Improvement Direction of Disaster Safety Education Training Course in School - Focused on Disaster Safety Management for School Facilities - (학교 재난안전 교육연수과정 실태분석 및 개선방향에 관한 연구 - 학교시설에 대한 재난안전관리 중심으로 -)

  • Lee, Byoung-Ho;Park, Youn-Ju;Lee, Jae-Rim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.2
    • /
    • pp.11-21
    • /
    • 2018
  • This study suggests desirable disaster safety education curriculum through analyzing the operational status of the school disaster safety management training course and demand survey of school staff. First, the problem of the disaster safety training course of the school is not connected with the lack of law and system and the school disaster safety job. Second, improvement of law and system and variety of training should be made to acquire professional knowledge. Third, it is necessary to divide curriculum into the following four categories, according to educational needs of public officials ; Educational administration officers course focused on facility safety, maintenance and disaster countermeasure. Educational officials in technical post course addressing approval and permission of school facility projects, seismic reinforcement of school building, etc. Educational supervisors course covering roles and responsibilities of the school safety supervisors in the event of disaster. Teaching staffs course focused on safety instructions for students. Fourth, it is found that lectures and experiential learning methods are the most desirable methods of teaching and learning, and the major ranks are earthquake disaster, fire, gas, typhoon, school road, and electrical safety.

A Prototype of Distributed Simulation for Facility Restoration Operation Analysis through Incorporation of Immediate Damage Assessment

  • Hwang, Sungjoo;Choi, MinJi;Starbuck, Richmond;Lee, SangHyun;Park, Moonseo
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.339-343
    • /
    • 2015
  • To rapidly recover ceased functionality of a facility after a catastrophic seismic event, critical decisions on facility repair works are made within a limited period of time. However, prolonged damage assessment of facilities, due to massive damage in the surrounding region and the complicated damage judgment procedures, may impede restoration planning. To assist reliable structural damage estimation without a deep knowledge and rapid interactive analysis among facility damage and restoration operations during the approximate restoration project planning phase, we developed a prototype of distributed facility restoration simulations through the use of high-level architecture (HLA) (IEEE 1516). The simulation prototype, in which three different simulations (including a seismic data retrieval technique, a structural response simulator, and a restoration simulation module) interact with each other, enables immediate damage estimation by promptly detecting earthquake intensity and the restoration operation analysis according to estimated damage. By conducting case simulations and experiments, research outcomes provide key insights into post-disaster restoration planning, including the extent to which facility damage varies according to disaster severity, facility location, and structures. Additional insights arise regarding the extent to which different facility damage patterns impact a project's performance, especially when facility damage is hard to estimate by observation. In particular, an understanding of required type and amount of repair activities (e.g., demolition works, structural reinforcement, frame installation, or finishing works) is expected to support project managers in approximate work scheduling or resource procurement plans.

  • PDF

Extraction of Disaster link Matrix Considering Flood Damage of Low-rise Structures due to Typhoon Effects (태풍 영향으로 인한 저층 시설물의 침수피해를 고려한 재난 연계 매트릭스 도출)

  • Lee, Byung-Hoon;Lee, Byung-Jin;Oh, Seung-Hee;Jung, Woo-Sug;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.5
    • /
    • pp.209-214
    • /
    • 2018
  • In this paper, we recognize the damage caused by a disaster to a facility in the event of a large-scale disaster and present the possible disasters in the form of a matrix. The typhoon was selected as a major disaster and covered mainly the flood damage, a possible damage caused by the typhoon. Flood damage is mainly caused by flooding, and damage is determined by flooding and flow rate, and the results of applying this to low-rise facilities are derived. In addition, the results were derived by applying a method of classification of disaster types in a matrix format to make it easy to see at a glance the connection between disasters caused by damage to a facility. Continuing research in the form presented in this paper will help us identify additional disasters as an occurrence of a disaster.

Comparison and Analysis of Childcare Facility Safety Manual in Korea and Japan (한국 보육시설과 일본 보육시설의 안전 매뉴얼 비교 분석)

  • Lee, Ji-Hyun
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.145-146
    • /
    • 2023
  • 본 연구는 한국 보육시설과 일본의 보육시설에서 사용하고 있는 안전관리 메뉴얼을 비교 분석해 보고자 한다. 본 연구의 제안을 통해 보육시설의 안전 매뉴얼의 구체적인 방안들이 제시되어 개선되어지는데 목적이 있다.

  • PDF

A Study on the Earthquake Safety Assessment of Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 지진 안전성평가에 관한 연구)

  • Ham, Eun-Gu;Lee, Sung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.226-235
    • /
    • 2021
  • Purpose: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Method: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Result: In this study, by statically loading earthquake loads and evaluating the level of collapse prevention of special-class structures, facility managers can easily recognize and evaluate the risk level, and this analysis result can be applied to future facility risk management. Earthquake analysis was performed so that. Conclusion: As a result of analyzing the Coalescer facility according to the current design standard KBC2016, the stress ratio of the main supporting members was found to be up to 4.7%. Therefore, the members supporting Coalescer were interpreted as being safe against earthquakes with a reproducibility period of 2400 years that may occur in Korea.

A Study on the Improvements Plans of the Disaster Dangerous Facilities Safety Management (재난위험시설 안전관리의 개선방안에 관한 연구)

  • Go, Seong-Seok;Yeo, Sang-Ku;Mun, Byung-Kyu
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.3
    • /
    • pp.143-151
    • /
    • 2012
  • The facility safety management in Korea does not secure efficiency as a safety management that is not constructed a maintenance manual. As such, disaster dangerous facilities are at a great danger for disaster occurrence. Accordingly, this study introduced revised requirement and revised level of requirement to field attendants to explore domestic facility safety management system, and set up and suggested a revised plan through brainstorming and attendants of central management institutions. This study is of importance that it reflects field attendants and attendants of central management institutions, suggests specific alternatives for realization to improve national level of institutional improvement.

Study of the MSW landfill Facility of Installation and Consideration (폐기물 매립시설 설치방법 및 고려사항에 대한 고찰)

  • Kim, Sang-Keun;Kwon, Ki-Bum;Yu, Jun;Chung, Ha-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.259-266
    • /
    • 2008
  • In the past, MSW (Municipal Solid Waste) disposal was typically done by recycling, incineration, or landfilling. In South Korea prior to the late 1950's, land burial was usually accomplished by disposal in an open dump. Currently, with increasing concerns and environmental recognition, MSW disposal and landfilling is more restricted. MSW landfill facilities have been developed with certain design and construction specifications. However, these methods have a space for improvement. MSW landfill facilities follow a step wise approach of design, construction, operation and closure management after use in agreement with established environmental and sanitary standards. This study intends to give a technical guidance for installation and consideration of newly established MSW landfill facilities, and also provide an establishment and regular inspection of MSW landfill facilities.

  • PDF

Current situation and proposal on the maintenance management for multiuse facility's disaster defense system. (다중이용시설 방재설비 현 상황과 유지관리 개선안)

  • Kim, Yeon-A;Hong, Tae-Hyeon
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.292-294
    • /
    • 2016
  • '16년 9월 경주지역 지진 발생으로 현재까지 여진이 계속 이어지고 있으며 우리나라 국토도 지진 또는 각종 자연재해, 재난으로부터 안전한 곳이 아니라는 인식을 심어주게 되었다. 본 연구에서는 사람들이 많이 이용하는 다중이용시설의 재난 발생 시 상당한 인적, 물적 피해를 우려하고 있으며 피해를 예방하고 최소화 할 수 있는 현재 방재설비를 확인하고 유지관리 개선안에 대해서 알아보고자 한다.

  • PDF

Utilization of Drone LiDAR for Field Investigation of Facility Collapse Accident (붕괴사고 현장조사를 위한 드론 LiDAR 활용)

  • Yonghan Jung ;Eontaek Lim ;Jaewook Suk;Seul Koo;Seongsam Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_2
    • /
    • pp.849-858
    • /
    • 2023
  • Investigating disaster sites such as earthquakes and landslides involves significant risks due to potential secondary disasters like facility collapse. In situations where direct access is challenging, there is a need to develop methods for safely acquiring high-precision 3D disaster information using light detection and ranging (LiDAR) equipped drone survey systems. In this study, the feasibility of using drone LiDAR in disaster scenarios was examined, focusing on the collapse accident at Jeongja Bridge in Bundang-gu, Seongnam City, in April 2023. High-density point clouds for the accident bridge were collected, and the bridge's 3D terrain information was reconstructed and compared to the measurement performance of 10 ground control points. The results showed horizontal and vertical root mean square error values of 0.032 m and 0.055 m, respectively. Additionally, when compared to a point cloud generated using ground LiDAR for the same target area, a vertical difference of approximately 0.08 m was observed, but overall shapes showed minimal discrepancies. Moreover, in terms of overall data acquisition and processing time, drone LiDAR was found to be more efficient than ground LiDAR. Therefore, the use of drone LiDAR in disaster sites with significant risks allows for safe and rapid onsite investigations.

A Study on the Cooling Center Manual of Facility and Maintenance for Extreme Heat Disaster (폭염재난에 대응하는 Cooling Center 시설 및 운영기준에 관한 연구)

  • Kim, Jin-Wook
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.17-22
    • /
    • 2008
  • Including heat wave, Climate change caused 150,000 casualty in 2000 and heat waves are meteorological events that pose a serious threat to human health. A heat wave is defined as "a period of abnormally and uncomfortably hot and usually humid weather". There is a need for the prevention of health effects due to weather and climate extremes. This study intends to propose the necessity of Response System to correspond to extreme heat. And this research focused on Cooling Center manual of facility and maintenance for extreme heat disaster. It would be useful to be planned based on community and to be taken a role as an E.O.C.(Emergency Operating Center). As a conclusion elderly watching system and the requirements regional cooling center facility was proposed.