• 제목/요약/키워드: facility

검색결과 11,493건 처리시간 0.043초

A Study on Proposing of Evaluation Factors for Educational Adequacy of Elementary School Facility (초등학교시설의 교육 지원성 평가요소 제안에 대한 연구)

  • Lee, Hyun-Joo
    • Korean Institute of Interior Design Journal
    • /
    • 제17권3호
    • /
    • pp.15-22
    • /
    • 2008
  • The purpose of this study is to propose evaluation factors for elementary school facility in terms of educational adequacy. The focal point of this study is to clarify the proper measure of educational facility evaluation in the light of specific characteristics of facility. In order to improve the level of educational adequacy, more information is needed regarding school facility design and various factors which affect to the design. This is important works because such information is essential in implementing facility design to meet the needs of the new educational policy. To get the goal, first, it is attempted to analyse the meaning of design information which deeply affect on the school facility design. The design information is classified into three main aspects, such as human aspect, social aspect and physical aspect. The design information regarding the physical space verses human psychology and behavior belongs to category of human aspect. Pedagogic ideology which varies depend upon the time and regions is classified into the category of social aspect. The Physical aspect means efficient equipment performance of space to support educational activities effectively. Secondly, as for the educational adequacy evaluation concern, it is attempted to select more items which usually has been neglected by the existing evaluation criteria which mainly emphasized functional performances only. With the premise of the above, in this paper, it is attempted to propose proper evaluation factors in terms of educational adequacy for school facilities. As the research methods, researching of literature on this subject, field trip, interview, site analysis, and survey is used.

A Study on the direction for Facility Improvement of Nationally Designated Negative Pressure Isolation Ward through Post Occupancy Evaluation (거주 후 평가를 통한 국가지정 입원치료병상 시설 개선 방향 도출에 관한 연구)

  • Jeong, Dawoon;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • 제27권3호
    • /
    • pp.39-49
    • /
    • 2021
  • Purpose: The negative pressure isolation ward is a key facility in preparedness and response to infectious diseases. For the sustainable operation of the facility, appropriate facility improvement is required. The experience of medical staff responding to infectious diseases in the COVID-19 pandemic provides effective informations for facility planning. Methods: The post occupancy evaluation (POE) was conducted by interviewing medical staff who is working on Nationally designated negative pressure isolation ward in general hospital. Floor plan analysis was conducted before field surveys for identifying facility characteristic and spatial composition. After that, field surveys were conducted at 3 hospitals, and interviews and fieldwork were conducted together. Results: It is necessary to increase the standard size of ward area from 15m2 to 20m2. The size of the doffing room has to be planned for accommodation of two or more people. Equipment storage, clean storage and waste storage also should be properly planned. There were almost no problems with the circulation in the ward. There was not enough space for medical staff. Implications: For a sustainable and safe negative pressure isolation ward planning, it is necessary to exploit learning from the medical staffs who have many experiences of coping with infectious diseases.

A Study on the Earthquake Safety Assessment of Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 지진 안전성평가에 관한 연구)

  • Ham, Eun-Gu;Lee, Sung-Il
    • Journal of the Society of Disaster Information
    • /
    • 제17권2호
    • /
    • pp.226-235
    • /
    • 2021
  • Purpose: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Method: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Result: In this study, by statically loading earthquake loads and evaluating the level of collapse prevention of special-class structures, facility managers can easily recognize and evaluate the risk level, and this analysis result can be applied to future facility risk management. Earthquake analysis was performed so that. Conclusion: As a result of analyzing the Coalescer facility according to the current design standard KBC2016, the stress ratio of the main supporting members was found to be up to 4.7%. Therefore, the members supporting Coalescer were interpreted as being safe against earthquakes with a reproducibility period of 2400 years that may occur in Korea.

The Development of N2O Emission Factor at Killn Type Pyrolysis Melting Facility (외열킬른형 열분해용융시설의 N2O 배출계수 개발)

  • Yun, Hyun-Ki;Lee, Dae Kyeom;Cho, Changsang;Kang, Seongmin;Yoon, Young joong;Jeon, Youngjae;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • 제8권3호
    • /
    • pp.231-237
    • /
    • 2017
  • In this study, the $N_2O$ emission factor of the facility was developed by measuring the kiln type pyrolysis melting facility. This used PAS (Photoacoustic Spectroscopy) method and measured the $N_2O$ emission concentration. From March 2016 to April 2016, it was measured over a total of two times and $N_2O$ concentrations were measured continuously for 24 hours using a 24 hour continuous measuring instrument (LSE-4405). The measured $N_2O$ emission concentration of the pyrolysis melting facility was 0.263 ppm on average and the emission concentration distribution in the range of 0.013~0.733 ppm was obtained. Therefore, the $N_2O$ emission factor of the kiln-type pyrolysis melting facility was estimated to be $0.829gN_2O/ton$-Waste. As a result of comparing the $N_2O$ emission factor of the thermal kiln type pyrolysis melting facility and the previous study, previous studies were about 18 times higher. It is estimated that this is due to the difference of furnace temperature, oxygen concentration and denitrification facilities. It is considered that the study of the emission factor of pyrolysis melting facility is an important factor in improving the credibility of greenhouse gas inventory in waste incineration sector.

A Study on the Management and Utilization and Application Method of Public Facility in Japanese (일본 분양공동주택의 공용시설 관리와 이용실태 및 활용방안에 관한 연구)

  • Lee, Su-Jin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • 제34권6호
    • /
    • pp.57-66
    • /
    • 2018
  • In Japan, apartment housing occupies a great proportion of residence due to high population density like Korea. Although Korea and Japan are similar in big proportions of apartment housing, and apartment housing management systems and utilization behaviors, there are considerable differences. This paper examined Japanese public facilities and the status of public facility management and utilization, which differ from those in Korea. In order to analyze the status of public facilities from a perspective of management companies, a preliminary survey was conducted targeting apartment management companies in the top 100 and a field study on public facilities was conducted targeting chief directors and managers of individual housing facilities to look into public facility utilization methods, problems with public facility management, demands of residents, and utilization situations. Also, the present state of facility utilization and utilization promotion plans were investigated, based on the drawings of facilities collected. As the result, results were found in three respects; 'elements, related to building plans', 'elements, related to utilization promotion', and 'elements, related to facility remodeling, including changes of uses'. In relation to the use of public facilities in the future, a more active communication between managers and users would be needed for planning. Also, there would be a need to provide public facilities for visitors when there are events for both occupants and visitors in order to promote the use of facilities and management companies would have to share information of excellent facility models.

A Study on the Expansion and Revitalization Plan when Conceiving Civil and Military Sharing Facilities - Factor Analysis and Analytic Hierarchy Process - (민군 시설공용 확대 및 활성화 방안에 관한 연구 - 요인 분석과 AHP분석 기법으로 -)

  • Gong, Keum Rok;Park, Young Jun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • 제34권5호
    • /
    • pp.19-26
    • /
    • 2018
  • A civil-military facility sharing project is a part of mutual cooperative efforts, which enables the military to use any civilian (local government or company) or a civilian to use any military facility. Such facility sharing project may reduce or clear possible conflicts with the local residents in the surrounding area of a military facility while being available to save budgets for new construction or maintenance of a defense or military facility. Various measures have been proposed for institutional resolutions on conflicts with the local residents in the surrounding area of a military facility. This study collects and organizes previous cases of the civilian-military facility sharing projects, and analyzes the characteristics of such cases based on the project types. In addition, by organizing and proposing the project characteristics, plans (ideas) and determination criteria to expand and vitalize are presented regarding the project types having restrictions. AHP technique is employed to research on the matrix for the project feasibility determination. Also, the opinions organized through the cause analysis are categorized and presented as a project for the expansion and vitalization of future project. According to the rearch result, Type I, II and III are determined to be projects that can be implemented without difficulties. Type IV, on the other hands, is determined as not illegal, yet inadequate so that some legal and institutional complements are required to expand and vitaliza this facility sharing project.

Preliminary design and assessment of a heat pipe residual heat removal system for the reactor driven subcritical facility

  • Zhang, Wenwen;Sun, Kaichao;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.3879-3891
    • /
    • 2021
  • A heat pipe residual heat removal system is proposed to be incorporated into the reactor driven subcritical (RDS) facility, which has been proposed by MIT Nuclear Reactor Laboratory for testing and demonstrating the Fluoride-salt-cooled High-temperature Reactor (FHR). It aims to reduce the risk of the system operation after the shutdown of the facility. One of the main components of the system is an air-cooled heat pipe heat exchanger. The alkali-metal high-temperature heat pipe was designed to meet the operation temperature and residual heat removal requirement of the facility. The heat pipe model developed in the previous work was adopted to simulate the designed heat pipe and assess the heat transport capability. 3D numerical simulation of the subcritical facility active zone was performed by the commercial CFD software STAR CCM + to investigate the operation characteristics of this proposed system. The thermal resistance network of the heat pipe was built and incorporated into the CFD model. The nominal condition, partial loss of air flow accident and partial heat pipe failure accident were simulated and analyzed. The results show that the residual heat removal system can provide sufficient cooling of the subcritical facility with a remarkable safety margin. The heat pipe can work under the recommended operation temperature range and the heat flux is below all thermal limits. The facility peak temperature is also lower than the safety limits.

Energy Harvesting System for Underground Facility Sensor (지하시설물용 센서 네트워크를 위한 에너지 획득 장치)

  • Kwon, Young-Min;Lee, Hyung-Su
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.136-137
    • /
    • 2009
  • In this paper, we introduce UFSN(Underground Facility Sensor Network) in order to build the intelligent management system for the underground facility and drainage in convergence with ubiquitous technologies and propose the energy harvesting system for UFSN.

  • PDF