• Title/Summary/Keyword: facilities for life cycle

Search Result 230, Processing Time 0.025 seconds

The Study on Application of Fast Track Method for Dam Project Life Cycle′s Analysis (댐 공사에서의 Fast Track을 적용한 생애주기분석에 관한 연구)

  • Yoon, Jae-Ho;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.5
    • /
    • pp.715-724
    • /
    • 2003
  • It is true that SOC facilities, such as dams, need long life cycles since more time has to be invested for the phases of planning, examination, feasibility study, design, contract, construction, and maintenance. This longer life cycle is easily exposed to the risk. And thus, brings additional cost by the delayed project, convenient loss according to the additional run of use, and benefit lose of not to using the facilities. So, the purpose of this study is to try to find a solution to reduce these time consuming problems which could diminish the whole national competition. Hence, this study is to show efficient, systematical project performance and network model by using reciprocal analyses between the construction period and cost based on economical analysis of each phase of life cycles. In addition, on the basis of these outputs, the Fast Track Method is suggested as an alternative solution as a new Approach in Life Cycle's Analysis.

A Study on the Improvement of Public Facility Management System Using Life-cycle Management (Life-cycle Management를 활용한 공공시설 유지관리 시스템 개선방안)

  • Jeon Ick-Sung;Shon Jeong-Rak;Kim Kyung-Suk;Kim Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.2 s.18
    • /
    • pp.55-63
    • /
    • 2004
  • A building structures was used the facility management phase through $planing\cdotdesign\cdotconstruction$. phase. building's length of life was shorter than its physical length of life, because of the lack of law and institution, the lack of related agencies' preparation and owner's preparation. Also, considering the construction life-cycle, the facility phase accounted for $70\%$ of whole official lift, therefore, it needed to be opposed to systemic facility management. Current facility management system practically managed the defect of facility and almost never communicated between the other phase. In the side of policy, domestic law, institution, and policy related to building structure focused built-up market. and then the management of existing facilities was not consolidated efficiently. The purpose of this study was to suggest the direction of facility management construction for managing, utilizing, and operating public facilities, moreover, to study the direction of current facility management system improvement corresponding to total computer integrated construction system under government agencies.

Development of Family Life Welfare Service Program for Promoting Quality of Life of Citizens -Focused on Community Centers in Daegu City- (지역주민의 삶의 질 향상을 위한 가정복지서비스 프로그램개발 - 대구시 주민자치센터를 중심으로-)

  • 조희금;채정숙
    • Journal of Families and Better Life
    • /
    • v.21 no.3
    • /
    • pp.133-146
    • /
    • 2003
  • The purpose of this study was to analyze the need for family life welfare service program, and to develope the program for managing in the Community Centers. The survey was conducted by interviewing 356 users and 360 non-users of Community Center, total 716 persons living in Daegu City, from October 8 to October 30 in 2002. The data were analyzed by the SPSS PC+ program applying t-test and ANOVA. The results were as follows : First, overall the needs for family life welfare service program, consisting of education program, facilities management and counseling program, and event program, was higher than 3.7 points. The needs level for event program was a little higher than other two programs. Second, the level of needs for family life welfare service program differed between user group and non-user group of the Community Centers. Third, the level of needs for family life welfare service program varied according to the demographic variables, such as sex, age, marital status, family life cycle, education level, vocation, monthly average income and housing type. Finally, Based on the results of needs analysis, 11 education programs, 4 facilities management and counseling programs and 5 event programs were developed for family life welfare service program. These programs developed in this study could be applied to diverse groups classified by age, social class, family life cycle of citizens. Also the programs should be applied in terms of family unit, as well as individual base to enhance the function of family life.

A Study of Determination on Usage Life of Production Facilities for Economic LCC (경제적 LCC 를 위한 생산설비의 사용년수에 관한 연구)

  • Yoo, Il-Geon;Park, Won-Jun
    • IE interfaces
    • /
    • v.6 no.2
    • /
    • pp.37-51
    • /
    • 1993
  • This paper studies the economic replacement method for production facilities which requires huge investment but are necessary for higher productivity and competability of products. That is, the general models for the decision of economic life of properties which minimizes the total costs throughout the usage life(Life cycle costs) are generated. Main factors which make influences for the decision of econmic life can be divided by three. These are the change of salvage value, repair and maintenance costs, and availability of production facilities with the passage of usage time. In this paper, the real world data for these three factors are collected and analyzed for the extraction of representative standard forms with the passage of time. And general models for economic replacement methods and optimal usage terms are presented through tables with the combination of the standard forms of these three main factors.

  • PDF

Minimum life-cycle cost design of ice-resistant offshore platforms

  • Li, Gang;Zhang, Da-Yong;Yue, Qian-Jin
    • Structural Engineering and Mechanics
    • /
    • v.31 no.1
    • /
    • pp.11-24
    • /
    • 2009
  • In China, the oil and natural gas resources of Bohai Bay are mainly marginal oil fields. It is necessary to build both ice-resistant and economical offshore platforms. However, risk is involved in the design, construction, utilization, maintenance of offshore platforms as uncertain events may occur within the life-cycle of a platform under the extreme ice load. In this study, the optimum design model of the expected life-cycle cost for ice-resistant platforms based on cost-effectiveness criterion is proposed. Multiple performance demands of the structure, facilities and crew members, associated with the failure assessment criteria and evaluation functions of costs of construction, consequences of structural failure modes including damage, revenue loss, death and injury as well as discounting cost over time are considered. An efficient approximate method of the global reliability analysis for the offshore platforms is provided, which converts the implicit nonlinear performance function in the conventional reliability analysis to linear explicit one. The proposed life-cycle optimum design formula are applied to a typical ice-resistant platform in Bohai Bay, and the results demonstrate that the life-cycle cost-effective optimum design model is more rational compared to the conventional design.

Analysis of Economic Replacement Cycle of Power Transformer Based on LCC Considering Maintenance Effect

  • Park, Seung-Hwa;Jang, Kyeong-Wook;Kweon, Dong-Jin;Shon, Jin-Geun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1631-1637
    • /
    • 2018
  • Electric utilities has been considered the necessity to introduce asset management of electric power facilities in order to reduce maintenance cost of existing facilities and to maximize profit. This paper aims to provide data that can helpful to make profitable decision in terms of power transformers which have a significant part in the power system. Therefore, this study is modeling input cost for power transformer during its entire life and also the life cycle cost (LCC) technique is applied. In particular, the variation of transformer state related with maintenance and the variation of the EUAC curve based on cost and effect of maintenance is examined. In this study, the trend of the equivalent uniform annual cost (EUAC) according to maintenance cycle and cost of equipment is analyzed. In line with that, sensitivity analysis influenced by the changes of other cost factors was performed.

A Study for the Elevation of Settlement in Residential District(I) (거주지역의 정주성 향상을 위한 연구 (I) - 미래 주거생활주기에 따른 대구지역 대학생의 지역선호와 가치를 중심으로 -)

  • 임소연;김재경;안옥희
    • Journal of the Korean housing association
    • /
    • v.10 no.4
    • /
    • pp.1-10
    • /
    • 1999
  • The purpose of this study was to investigate the environmental factors having a influence on the preference of residential district and to furnish basic information for the successful settlement. For the purpose, residential preference and values on the residential district were estimated according to the housing life cycle. Data were collected through questionnaires designed for this study, and the objects of this research were university students. To analyze the data were used spsswin program. The major results were as follows. 1. According to the housing life cycle, there were significant differences in the preference of the residential district, living area and housing type in the future. Metropolitan and seoul, residential area and commercial area, apartment, office-hotel and row house were preferred in the housing formative. In the stable period, seoul and metropolitan, tower apartment, residential area were preferred. But in the housing reductive period, they preferred a green zone in the rural, the detached house. 2. The degree of consideration of living convenience facilities was high in the housing formative period. Both education-leisure, business facilities and marketing facilities were highly valuated in the housing stable period. But the value of welfare facilities was high in the housing reductive period. 3. The 4 dimensions of values in environmental conditions were extracted through factor analysis. They were natural, human, social, and economic factors. According to the housing life cycle, there were significant differences in factors being considered as the environmental conditions. The values of human and economic factors were high in the housing formative and stable period. Natural factor were highly considered in the housing reductive period.

  • PDF

LCCA and LCA to Evaluate Feasibility for Introducing High-Efficiency Motors into Air Ventilation Systems of Public Facilities (고효율 전동기를 다중이용시설 환기설비에 도입하기 위한 LCCA 및 LCA 분석)

  • Quan, Junlong;Choi, Sooho;Kwon, Taehwan;Choi, Hyemi;Kim, Juhyung;Kim, Jaejun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.4
    • /
    • pp.41-49
    • /
    • 2015
  • The amount of energy consumed in air ventilation systems of public facilities accounts for 40% of their total energy consumption. To reduce their energy consumption, applying variable speed operation controlled by an inverter with a high-efficiency motor is suggested. Since these methods require higher initial investment costs compared to the existing systems, economic evaluation should be conducted from a long-term perspective. While LCCA(Life Cycle Cost Analysis) model is useful to estimate net savings of alternatives that differs with respect to initial costs and operating costs, the environmental burdens are not considered. On the contrary LCA(Life Cycle Assesment) model is suitable to assess environmental impacts associated with the stages of a product's life but it does not consider costs. In this study, the high-efficient motors are introduced into the air ventilation system of a subway station and a comprehensive analysis on the economic and environmental impacts of the proposed method is conducted by using LCCA and LCA model.

Economic Life Assessment of Power Transformer using HS Optimization Algorithm (HS 최적화 알고리즘을 이용한 전력용 변압기의 경제적 수명평가)

  • Lee, Tae-bong;Shon, Jin-geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.123-128
    • /
    • 2017
  • Electric utilities has been considered the necessity to introduce AM(asset management) of electric power facilities in order to reduce maintenance cost of existing facilities and to maximize profit. In order to make decisions in terms of repairs and replacements for power transformers, not only measuring by counting parts and labor costs, but comprehensive comparison including reliability and cost is needed. Therefore, this study is modeling input cost for power transformer during its entire life and also the life cycle cost (LCC) technique is applied. In particular, this paper presents an application of heuristic harmony search(HS) optimization algorithm to the convergence and the validity of economic life assessment of power transformer from LCC technique. This recently developed HS algorithm is conceptualized using the musical process of searching for a perfect state of harmony. It uses a stochastic random search instead of a gradient search so that derivative information is unnecessary. The effectiveness of the proposed identification method has been demonstrated through an economic life assessment simulation of power transformer using HS optimization algorithm.

A Determination and application of a future failure rate for LTAM strategies Development on Nuclear Turbines (원자력터빈의 LTAM 전략개발을 위한 미래고장률 결정 및 적용)

  • Shin, Hye-Young;Yun, Eun-Sub
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2845-2849
    • /
    • 2008
  • Long Term Asset Management(LTAM) means a plan developed by using LCM(Life Cycle Management) process for optimum life cycle management of significant plant assets at each plant across the fleet. As a part of development of LTAM Strategies on nuclear turbines, a method so as to determine the future failure rates for low pressure turbine facilities at a nuclear plant was studied and developed by using both plant specific and industry-wide performance data. INPO's EPIX data were analyzed and some failure rate evaluation values considering preventive maintenance practices were calculated by using EPRI's PM Basis software. As the result, failure rate functions applicable to a priori and a posteriori replacement of low pressure turbines at a nuclear plant were developed and utilized in an assessment of economics of LCM alternatives on the nuclear turbine facilities in the respects of 40-year and 60-year operation bases.

  • PDF