• Title/Summary/Keyword: fabric damage

Search Result 115, Processing Time 0.027 seconds

Progressive Damage Analysis of Plain Weave Fabric CFRP Orthogonal Grid Shell Under Bending Load (굽힘 하중을 받는 평직물 CFRP 직교 격자 쉘의 점진적 손상 해석)

  • Lim, Sung June;Baek, Sang Min;Kim, Min Sung;Park, Min Young;Park, Chan Yik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.4
    • /
    • pp.256-265
    • /
    • 2019
  • In this paper, the progressive damage of an orthogonal grid shell fabricated with plain weave fabric CFRP under bending load was investigated. The orthogonal grids were cured with the bottom composite shell. Progressive damage analysis of an orthogonal grid shell under bending was performed using nonlinear finite element method with Hashin-Rotem failure criterion and Matzenmiller-Lubliner-Taylor(MLT) model. In addition, the three - point bending test for the structure was carried out and the test results were compared with the analysis results. The comparison results of the strain and displacement agreed well. The damage area estimated by the progressive damage analysis were compared with the visual inspection and ultrasonic non-destructive inspection.

Indigo Dyeing of Mongolian Cashmere Fiber

  • Narantuya, Lkhagva;Ahn, Cheunsoon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.6
    • /
    • pp.979-993
    • /
    • 2016
  • Mongolian cashmere sliver, yarn, and fabric were dyed and bleached with a solution of ascorbic acid and iron sulfate at $70^{\circ}C$, and then dyed using natural indigo powder at the dyeing temperature of $25^{\circ}C$ to $90^{\circ}C$ for 15-90 minutes using the IR dyeing machine. K/S values of bleached samples decreased significantly when dyed above $70^{\circ}C$ dyeing temperature for a longer dyeing time. Bleached cashmere fabric showed a greater loss of tensile strength than unbleached cashmere fabric, even when the samples were dyed at $40^{\circ}C$. With a higher dyeing temperature, yarns lost fullness, became thinner, and the pores between the yarns were enlarged. The x-ray diffraction pattern exhibited a prominent increase in crystallinity and the protein assay indicated a loss of protein in the bleached sample dyed at $90^{\circ}C$. Thinning of scales, fractured or raised tip of scales, and roughness on the entire surface of the fiber were also observed. The results indicate that bleaching and high temperature dyeing cause a serious damage to cashmere fibers. In addition, bleaching and high temperature dyeing cause significant fiber damage. Natural indigo dyeing using low temperature dyeing is recommended to produce blue color cashmere.

Multi-objective durability and layout design of fabric braided braking hose in cyclic motion

  • Cho, J.R.;Kim, Y.H.
    • Steel and Composite Structures
    • /
    • v.25 no.4
    • /
    • pp.403-413
    • /
    • 2017
  • The fabric braided braking hose that delivers the driver's braking force to brake cylinder undergoes the large deformation cyclic motion according to the steering and bump/rebound motions of vehicle. The cyclic large deformation of braking hose may give rise to two critical problems: the interference with other adjacent vehicle parts and the micro cracking stemming from the fatigue damage accumulation. Hence, both the hose deformation and the fatigue damage become the critical issue in the design of braking hose. In this context, this paper introduces a multi-objective optimization method for minimizing the both quantities. The total length of hose and the helix angles of fabric braided composite layers are chosen for the design variables, and the maximum hose deformation and the critical fatigue life cycle are defined by the individual single objective functions. The trade-off between two single objective functions is made by introducing the weighting factors. The proposed optimization method is validated and the improvement of initial hose design is examined through the benchmark simulation. Furthermore, the dependence of optimum solutions on the weighting factors is also investigated.

A comparison of detergency and dimensional stability between wet cleaning and dry cleaning (물세탁과 드라이클리닝의 세탁성능과 형태안정성 비교)

  • Kwak, Soo-Kyung;Kim, Ah-Ri;Oh, Hwawon;Park, Myung-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.21 no.1
    • /
    • pp.181-189
    • /
    • 2019
  • The washability, redeposition, fill power, and fabric damage of wet cleaning and dry cleaning solvents were measured to identify the optimal type of washing that would increase washability while maintaining dimensional stability. The soiled fabric is a polyester cotton blend and the types of soil were wine, blood, make-up and sebum with carbon black. Petroleum and silicone solvents were used in dry cleaning. Results from this study are as follows. First, detergency is significantly influenced by the type of washing and type of soil. Wet cleaning is superior to dry cleaning. Wet cleaning shows a strong washing performance against hydrophilic soils, whereas, dry cleaning is stronger against hydrophobic soils. Second, redeposition is significantly affected by the type of washing, fabrics, and soils. Redeposition occurred little on cotton during wet cleaning, but showed a high rate for nylon. However, when the two types of fabric were dry cleaned, redeposition occurred on both types. Third, the fill power of duck-down is very affected by the type of washing. Resilience is the best in wet cleaning; and in dry cleaning, petroleum solvents showed a higher resilience when as compared to silicone solvents. Last, the level of fabric damage to cotton fabrics is highly influenced by the type of washing. Wet cleaning damages cotton fabrics significantly more than dry cleaning. For dry cleaning, petroleum solvents damage these fabrics slightly more than silicone solvents. In conclusion, the type of soil must initially be identified to determine the optimal type of washing. Special caution is required when textiles with particulate soil and nylon are washed. When considering the resilience of duck-down clothing, wet cleaning is more appropriate than dry cleaning. Dry cleaning, especially when using silicone-based solvents, is more suitable than wet cleaning for maintaining the shape of clothing.

Physical Property Change of Old Fabrics Depending on Cleaning Method (출토 직물의 세탁 방법에 따른 물성 변화)

  • 배순화;이미식
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • The purpose of this study was to compare the efficiency of four different cleaning method of silk and to fabrics, which were excavated from the sixteenth century tombs. The four cleaning methods were hand washing in water and hand washing in solvent, washing in ultrasonic cleaner, and using of ultrasonic gun after washing in ultrasonic cleaner. The following is the result of the experiment: ㆍBoth silk and jute fabrics shrank the most after hand-wash in water. This cleaning method decreased their thickness the most but changed their strength the least. However, the color of the fabric changed the most after had-wash in water. This washing method might discolor the dyed fabric, so one must check the condition of the fabric thoroughly before washing it. ㆍThe weight and the thickness of the fabric changed little after ultrasonic cleaning. This cleaning method, therefore. is less efficient than hand-water-wash. The use of ultrasonic gun after ultrasonic wash for partial cleansing enhanced the efficiency a little. Nevertheless, this method left stain around the area where the gun was used, and the injected water could damage the fabric. ㆍThe excavated fabric became softer in the cleaning process as the dirt was washed away. In both cases of silk and jute fabrics cleaning, solvent made the fabric softer than water. Washed in solvent, the fabric did not swell. But water penetrated to the fiber during the cleaning process and made the fabric swell. When the water evaporates, the swollen fiber structure collapses and the fabric become stiff. Ultrasonic wash did not cause much change in the flexibility of the fabric, for this method does not remove the dirt as effectively as the other method.

Influence of covering treatment on the incidence of frost injury in chinese cabbage during winter season (피복처리가 월동배추 동해 발생에 미치는 영향)

  • Lee, Sang Gyu;Choi, Chang Sun;Lee, Hee Ju;Jang, Yoon Ah;Do, Kyung Ran
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.3
    • /
    • pp.163-167
    • /
    • 2014
  • The average temperatures for year and winter season have been risen by $0.7{\circ}C$ and $1.4{\circ}C$, respectively, during the last 30 years. Recently abnormal climate phenomena occurred frequently results in severe loss of vegetable crops grown in Korea. Specially, Chinese cabbages grown in the southern area of Korea are often significantly affected by sudden cold waves during winter season before harvest. This experiment was conducted to find out a potential role of covering materials on the protection of frost damage of 'Bularm' chinese cabbage in the winter season. The lowest temperature was $-15.8^{\circ}C$ in non-covering, $-8.1^{\circ}C$ in the PE film covering and $-4.6^{\circ}C$ in the non-woven fabric covering with PE film, respectively. The cumulative times below $4.0^{\circ}C$ were 145.5 hours for the non-covering treatment, 94 hours in the PE film covering and 14.5 hours in the non-woven fabric covering with PE film, respectively. The symptoms of frost damage were severe at non-covering chinese cabbages compared to polyethylene film (PE) non-woven fabric with PE covering ones. Microscopic studies showed the normal anatomical structure of palisade and spongy tissue of cabbage leaves covered with non-woven fabric with PE film. Leaf cells, however, were slightly damaged in cabbages covered with PE film alone, and both palisade and spongy cells were were completely collapsed in uncovered cabbages. The result of this study suggests that chinese cabbages is required to be covered with non-woven fabric with PE film to minimize the frost damage by sudden cold wave below $-7^{\circ}C$.

A Study on the Shrink Resist Finish of Wool Fabric(I) - Effect of Treating Condition on Mechanical Properties of Wool Fabric with Chlorination and MONAMIN BTN Resin - (양모직물의 방축가공에 관한 연구(I) - 염소화/MONAMIN BTN 방축가공 양모직물의 역학특성에 미치는 처리조건의 영향 -)

  • 황백순;이재호;김덕리
    • Textile Coloration and Finishing
    • /
    • v.13 no.4
    • /
    • pp.272-281
    • /
    • 2001
  • Shrink resist finishing of wool fabric was carried out with MONAMIN BTN shrink resist agent after chlorination with D.C.C.A.(dichloro isocyanuric acid). The purpose of this study is to investigate the effect of treating conditions, such as concentrations of D.C.C.A and MONAMIN BTN, pH of treating bath, dying times, curing times and temperatures, on shrink resist finishing. Mechanical properties of the treated fabric were measured by KES-FB system. The optimum chlorination of wool corresponds to 2∼3%(o.w.f.) of D.C.C.A. without rendering the damage on surface of wool fiber. Also it seems likely that the shirink resist finishing carried out at 2 ∼3%(o.w.f.) of MONAMIN BTN and pH 7∼8 of treating bath is effective in increasing a softness of hand.

  • PDF

A Study on Dyeing of Silk with Different Reactive Dyes (반응성염료의 반응기에 따른 견섬유염색에 관한 연구)

  • 정지인;류효선
    • Textile Coloration and Finishing
    • /
    • v.4 no.4
    • /
    • pp.73-80
    • /
    • 1992
  • The influence of four types of reactive dyes that are different in reactive group on silk fabric were investigated at three different temperatures, 5$0^{\circ}C$, 7$0^{\circ}C$, 9$0^{\circ}C$ and the pH range from 7.0 to 11.0. The amount of absorption and fixation showed the optimum condition. The damage of silk during dyeing was determined by the change of physical properties. The results are given as follows: 1. The amount of dye fixed on fabrics at constant pH varied upon the reactivity of dyes. The affinity of dyes for silk fabrics were in order of Lanasol>Procion>Remazol>Cibacron. 2. The percentage of dye fixation on fabrics showed different tendency with temperature. The dye fixation of Cibacron and Procion was decreased above 7$0^{\circ}C$ because of the influence of hydrolysis. The dye fixation of Lanasol and Remazol was increased with the increase of temperature. This showed that temperature did not affect on hydrolysis. 3. The tensile strength of dyed fabric decreased with increasing pH and temperature owing to high temperature and alkaline damage on silk fabric. 4. The optimum conditions of dyeing silk with reactive dyes were as follows: Cibacron -7$0^{\circ}C$, pH 9.0, Procion-5$0^{\circ}C$, pH 7.0, Remazol-5$0^{\circ}C$, pH 8.0, and Lanasol-9$0^{\circ}C$, pH 9.0.

  • PDF

Evaluation of Washing Efficiency based on Consumer's Washing Behavior Integral Approach for Improving Washing Machines (II)- (소비자의 세탁습관에 따른 세탁효율 평가 -국산세탁기의 경쟁력 강화를 위한 세탁 실태조사 및 실험연구(II)-)

  • 오경화;유혜경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.2
    • /
    • pp.251-261
    • /
    • 1997
  • According to consumer's washing behavior, the washing efficiency of three different types of washing machines-pulsator, agitator, and drum was studied. Their detergency, rinsing efficiency, and the degree of fabric damage, tangle, and wrinkle were evaluated. The results showed that efficient washing capacity was different from the specified capacity of washing machine. Detergency and rinsing efficiency frere apparently decreased when more than 50% of capacity was loaded in washing machine of pulsator type, and 80% for agitator or drum types. They were also affected by detergent adding methods, and decreased in the order of water-detergent-washing load> washing load-detergent-water> washing load-water-detergent. Rinsing efficiency was significantly improved when the rinsing temperature was set above washing temperature. In addition, it was revealed that detergency, fabric damage, wrinkle, and tangle were highly correlated. The relationships between detergency and tangle were different for different types of washing machine. Positive relationships were found for agitator and drum types, whereas negative for pulsator type.

  • PDF