• Title/Summary/Keyword: f0 intervals

Search Result 147, Processing Time 0.033 seconds

Subacute toxicity of cis-Malonato[(4R,5R)-4,5-bis(aminomethyl)-2-isopropyl-1,3-dioxolane]platinum(II)(SKI 2053R) in Beagle Dogs (Beagle Dog에서 cis-Malonato[(4R,5R)-4,5-bis(aminomethyl)-2-isopropyl-1,3-dioxolane]platinum(II)(SKI 2053R)의 아급성독성시험에 관한 연구)

  • Lee, Yong-Soon;Kang, Kyung-Sun;Shin, Dong-Jin;Cho, Jae-Jin;Kim, Hyoung-Ook;Kim, Bae-Hwan;Lim, Yoon-Kyu
    • Toxicological Research
    • /
    • v.8 no.2
    • /
    • pp.235-253
    • /
    • 1992
  • A subacute toxicity study of cis-Malonato[(4R,5R)-4,5-bis(aminomethyl)-2-isopropyl-1,3-dioxolane]platinum(II)(SKI 2053R) was carried out to obtain information on its toxicological profiles, and to determine the maximum tolerated dose in beagle dogs. Four groups of beagle dogs (2M and 2F per group, 0,0.5,1.0,2.0mg/kg/day)were given 15 i.v. injections of SKI 2053R. In order to compare the toxic effects of SKI 2053R with those of cisplatin, one group was treated with cisplatin(0.7mg/kg/day)according to the same treatment schedule. The dosing schedule was divided into 3 courses of 5 consecutive days with 23-day dose-free intervals between each course. After completion of the treatments, remaining dogs were necropsied under established guidelines. Three of four dogs in the high dose group and one of four dogs in the middle dose group treated with SKI 2053R died of hypovolemic shock secondary to hemorrhagic and ulcerative enterocolitis. No toxicity-related mortality occurred in the low dose group of SKI 2053R. No survivor was observed in the group of cisplatin. Clinical signs including vomiting, diarrhea, anorexia and loss body weight were apparent in dogs given either cisplatin or high and middle doses of SKI 2053R. Severe thrombocytopenia and leukocytopenia were observed in the high dose group of SKI 2053R and cisplatin-treatment group, while toxicities as bone marrow suppression were reversible. The significant elevation of serum ALP values in group of SKI 2053R(2.0 mg/kg/day and 1.0mg/kg/day) and cisplatin(0.7mg/kg/day)was observed. Slight proteinuria waa observed in high and middle dose level groups of SKI 2053R. In histopathological examinations, pathological alterations of liver, kidney and spleen were noted dose-dependantly in dogs treated with SKI 2053R, and there was no overt sign of toxicity in low dose group of SKI 2053R. Compared to SKI 2053R, more severe durg-related toxicities occurred in dogs treated with cisplatin. It waw estimated that maximum tolerated dose of SKI 2053R in this treatment schedule was 0.5~0.7mg/kg/day. In conclusion, overall toxic potential of SKI 2053R was approximately 3 times lower than that of cisplatin with respect of lethality.

  • PDF

Distribution of DArT Markers in a Genetic Linkage Map of Tomato (토마토 유전자연관지도 상의 DarT 마커 분포)

  • Truong, Hai Thi Hong;Graham, Elaine;Esch, Elisabeth;Wang, Jaw-Fen;Hanson, Peter
    • Horticultural Science & Technology
    • /
    • v.28 no.4
    • /
    • pp.664-671
    • /
    • 2010
  • A genetic linkage map was constructed using 188 $F_9$ RILs derived from a cross between $Solanum$ $lycopersicum$ H7996 (resistant to bacterial wilt) and $S.$ $pimpinellifolium$ WVa700 (highly susceptible to bacterial wilt). The map consisted of 361 markers including 260 DArTs, 74 AFLPs, 4 RFLPs, 1 SNP, and 22 SSRs. The resulting linkage map was comprised of 13 linkage groups covering 2042.7 cM. The genetic linkage map had an average map distance between markers of 5.7 cM, with an average DArT marker density of 1/7.9 cM. Based on the distribution of anchor SSR markers, 11 linkage groups were assigned to 10 chromosomes of tomato except chromosomes 5 and 12. The DArT markers were distributed across the genome in a similar way as other markers and showed the highest frequency of clustering (38.8%) at ${\leq}$ 0.5 cM intervals between adjacent markers, which is 3 times higher than AFLPs (13.5%). The present study is the first utilization of DArT markers in tomato linkage map construction.

Preliminary Study of The Periodic Limb Movement Disorder Following Nasal CPAP : Is It Associated With Supine-Sleeping Position? (지속적 양압술과 수면중 주기적 사지운동 장애의 관계에 대한 예비적 연구 : 앙와위가 주기적 사지운동 장애와 관련되는가?)

  • Yang, Chang-Kook;Clerk, Alex A
    • Sleep Medicine and Psychophysiology
    • /
    • v.4 no.2
    • /
    • pp.164-171
    • /
    • 1997
  • Introduction : Periodic limb movement disorder (PLMD) is shown to common in patients with OSA and may become evident or worsened when treated with nasal continuous positive airway pressure (CPAP). Whether this is due to im proved sleep continuity. adverse nocturnal body positioning, uncovered by CPAP, or due to the CPAP stimulus is still debat-ed. We hypothesized that the increase in PLM activity following CPAP is associated with more supine-sleeping tendencies when being treated with CPAP. In the present work, we compared differences in the PLMD index (PLMI) and sleeping position of patients with sleep disordered breathing before and after CPAP treatment. Method : We studied 16 patients (mean age 46 yr, 9M, 7F) with OSA (11 patients) or UARS (5 patients) who either had PLMD on initial polysomnogram (baseline PSG) or on nasal CPAP trial (CPAP PSG). All periodic leg movements were scored on anterior tibialis EMG during sleep according to standard criteria (net duration; 0.5-5.0 seconds, intervals; 4-90 seconds. 4 consecutive movements). Paired t-tests compared PLMD index (PLMI), PLMD-related arousal index (PLMD-ArI), respiratory disturbance index (RDI), and supine sleeping position spent with baseline PSG and CPAP PSG. Results : Ten patients (63%) on baseline PSG and fifteen patients (94%) on CPAP PSG had documented PLMD ($PLMI{\ge}5$) respectively with significant increase on CPAP PSG(p<0.05). Ten patients showed the emergence (6/10 patients) or substantial worsening (4/10 patients) of PLMD during CPAP trial. Mean CPAP pressure was $7.6{\pm}1.8\;cmH_2O$. PLMI tended to increase from baseline PSG to CPAP PSG, and significantly increase when excluding 2 outlier (baseline PSG, $19.0{\pm}25.8/hr$ vs CPAP PSG, $29.9{\pm}12.5/hr$, p<0.1). PLMD-ArI showed no significant change, but a significant decrease was detected when excluding 2 outlier (p<0.1). There was no significant sleeping positional difference (supine vs non-supine) on baseline PSG, but significantly more supine position (supine vs non-supine, p<0.05) on CPAP PSG. There was no significant difference in PLMI during supine-sleeping and nonsupine-sleeping position on both of baseline PSG and CPAP PSG. There was also no significant difference in PLMI during supine-sleeping position between baseline PSG and CPAP PSG. With nasal CPAP, there was a highly significant reduction in the RDI (baseline PSG, $14.1{\pm}21.3/hr$ vs CPAP PSG, $2.7{\pm}3.9/hr$, p<0.05). Conclusion : This preliminary data confirms previous findings that CPAP is a very effective treatment for OSA, and that PLMD is developed or worsened with treatment by CPAP. This data also indicates that supine-sleeping position is more common when being treated with CPAP. However, there was no clear evidence that supine position is the causal factor of increased PLMD with CPAP. It is, however, suggested that the relative movement limitation induced by CPAP treatment could be a contributory factor of PLMD.

  • PDF

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

Removal Performance of Sticky Paint Aerosol Control System Generated from Small Scale Car Paint Overspray Booth (소형 자동차 페인트 도장부스에서 발생하는 점착성 paint aerosol 처리장치에서 제거성능)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Sohn, Jong-Ryeul;Park, Young-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.1
    • /
    • pp.54-62
    • /
    • 2015
  • Small scale paint overspray booths are being operated nationwidely, for repair of passenger car body parts. paint aerosols are emitted from the paint overspray booth in operations. In paint overspray booth operations without ventilation system and air pollutants collection unit, it may land on nearby equipment. In this study a removal of sticky paint aerosol for application of the small-scale overspray paint booth. it's cause the surface of filter bag from generated sticky paint aerosol. To remove adhesion of paint aerosol the agglomerating agents are injected and mixed with sticky paint aerosols prior to reach the filter bag. The paint spray rate was set as $10{\pm}5g/min$ from air-atomized spray guns in the spray booth, injection rate of agglomerating was $10{\pm}5g/min$ in the mixing chamber. The filtration velocity including air pollutants varied from 0.2 m/min to 0.4 m/min. Bag cleaning air pressure was set as $5.0kg_f/min$ for detaching dust cake from surface of filter bag. Bag cleaning interval at the filtration velocity of 0.2 m/min was around 3 times longer than that of the 0.4 m/min. The residual pressure drop maintained highest value at the highest filtration velocity. Fractional efficiency of 99.952%~99.971% was possible to maintain for the particle size of 2.5 microns. Total collection efficiency at the filtration velocity of 0.2 m/min was 99.42%. During this study we could confirm high collection efficiency and long cleaning intervals for the test with filtration velocity of 0.2 m/min indicating an optimal value for the given dimensions of the test unit and test operating conditions.

Effect of occlusal balance on center of gravity in body (교합균형이 자세 중심(重心)에 미치는 영향에 관한 연구)

  • Lee, Yun;Choi, Dae-Kyun;Lee, Sung-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.57-67
    • /
    • 2003
  • Suppose that dental occlusion is related to body posture. We want to find out that improving occlusal balance may affect vibration and distribution of C.O.P. in which way, by measuring change of posture and center of gravity (center of pressure, C.O.P.) which plays important role in measuring balance sensation. Total 11 students at Kyung Hee dental college students, 4 females and 9 males (age: 23-30) participated in this test, who have normal occlusion (Angle's classification I), no TMJ problems. All of the participants have no tooth loss except 3rd molar, no prosthesis over single tooth restoration, no orthopedic problems which affect balance sensation, and no otorhinolaryngological problems. First, we registrated bite by centric relation, and then fabricated stabilization splint that is increased 3.5mm vertical dimension around premolar region. By F-scan (Tekscan Inc., Boston, Mass), we measured discrepancy of average contact pressure of left and right foot. And we also measured discrepancy of vibration of C.O.P(center of pressure). before setting stabilization splint and after wearing stabilization splint at intervals of 1 week, 2 weeks, 3 weeks after. In normal human beings, improved occlusal balance by stabilization splint leads to decrease of vibration of C.O.P. (P<0.05). One week after wearing stabilization splint, vibration of C.O.P. decreased reliably (P<0.05), two weeks after wearing stabilization splint, vibration of C.O.P. decreased similarly comparing to before wearing and one week after wearing. (P<0.05) After two weeks and three weeks, however, it was hard to find reliability. (P>0.05) Difference between average contact pressure of right and left foot also decreased. (P<0.05) We could find decrease after one week of wearing stabilization splint (P<0.05) and two weeks after, the decrease was more reliable than one week after. (P<0.05) After two weeks and three weeks, however, it was hard to find reliability. Improvement of occlusal balance leads to decrease of vibration of C.O.P. and decrease of difference between right and left average contact pressure.

Formulation of Ceftriaxone Conjugated Gold Nanoparticles and Their Medical Applications against Extended-Spectrum β-Lactamase Producing Bacteria and Breast Cancer

  • El-Rab, Sanaa M.F. Gad;Halawani, Eman M.;Hassan, Aziza M.
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.9
    • /
    • pp.1563-1572
    • /
    • 2018
  • Gold nanoparticles (AuNP) and their conjugates have been gaining a great deal of recognition in the medical field. Meanwhile, extended-spectrum ${\beta}$-lactamases (ESBL)-producing bacteria are also demonstrating a challenging problem for health care. The aim of this study was the biosynthesis of AuNP using Rosa damascenes petal extract and conjugation of ceftriaxone antibiotic (Cef-AuNP) in inhibiting ESBL-producing bacteria and study of in vitro anticancer activity. Characterization of the synthesized AuNP and Cef-AuNP was studied. ESBL-producing strains, Acinetobacter baumannii ACI1 and Pseudomonas aeruginosa PSE4 were used for testing the efficacy of Cef-AuNP. The cells of MCF-7 breast cancer were treated with previous AuNP and Cef-AuNP at different time intervals. Cytotoxicity effects of apoptosis and its molecular mechanism were evaluated. Ultraviolet-visible spectroscopy and Fourier transform infrared spectroscopy established the formation of AuNP and Cef-AuNP. Transmission electron microscope demonstrated that the formed nanoparticles were of different shapes with sizes of 15~35 nm and conjugation was established by a slight increase in size. Minimum inhibitory concentration (MIC) values of Cef-AuNP against tested strains were obtained as 3.6 and $4{\mu}g/ml$, respectively. Cef-AuNP demonstrated a decrease in the MIC of ceftriaxone down to more than 27 folds on the studied strains. The biosynthesized AuNP displayed apoptotic and time-dependent cytotoxic effects in the cells of MCF-7 at a concentration of $0.1{\mu}g/ml$ medium. The Cef-AuNP have low significant effects on MCF-7 cells. These results enhance the conjugating utility in old unresponsive ceftriaxone with AuNP to restore its efficiency against otherwise resistant bacterial pathogens. Additionally, AuNP may be used as an alternative chemotherapeutic treatment of MCF-7 cancer cells.

Metformin Association with Lower Prostate Cancer Recurrence in Type 2 Diabetes: a Systematic Review and Meta-analysis

  • Hwang, In Cheol;Park, Sang Min;Shin, Doosup;Ahn, Hong Yup;Rieken, Malte;Shariat, Shahrokh F.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.595-600
    • /
    • 2015
  • Background: Accumulating evidence suggests that metformin possesses anticarcinogenic properties, and its use is associated with favorable outcomes in several cancers. However, it remains unclear whether metformin influences prognosis in prostate cancer (PCa) with concurrent type 2 diabetes (T2D). Materials and Methods: We searched PubMed, EMBASE, and the Cochrane Library from database inception to April 16, 2014 without language restrictions to identify studies investigating the effect of metformin treatment on outcomes of PCa with concurrent T2D. We conducted a meta-analysis to quantify the risk of recurrence, progression, cancer-specific mortality, and all-cause mortality. Summary relative risks (RRs) with corresponding 95% confidence intervals (CIs) were calculated. Publication bias was assessed by Begg's rank correlation test. Results: A total of eight studies fulfilled the eligibility criteria. We found that diabetic PCa patients who did not use metformin were at increased risk of cancer recurrence (RR, 1.20; 95%CI, 1.00-1.44), compared with those who used metformin. A similar trend was observed for other outcomes, but their relationships did not reach statistical significance. Funnel plot asymmetry was not observed among studies reporting recurrence (p=0.086). Conclusions: Our results suggest that metformin may improve outcomes in PCa patients with concurrent T2D. Well-designed large studies and collaborative basic research are warranted.

A Basic Study on Efficient Acrylic Plate Light Transmission Road Machining (효율적인 아크릴판 광전송로 가공에 관한 기초 연구)

  • Han, Su-Won;Hong, Jun-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.1
    • /
    • pp.95-101
    • /
    • 2022
  • This paper proposes a method to process the shape of an optical transmission road and attempts to determine the most suitable single processing method for an acrylic plate optical transmission road. In addition, by manufacturing an automatic pattern processing device to generate certain shapes on the acrylic plate at regular intervals, and measuring the illuminance of the patterned acrylic plate optical transmission road, the measured illuminance was confirmed to fall under the KS illuminance values presented in Table 1. In conclusion, when an incident light of approximately 20,000 lx is applied, the transmission illumination is approximately 200 lx, which represents a transmission rate of approximately 1% for incident light and corresponds to the KS illumination criterion F. Additionally, the right-angle triangular pyramid base size (A) processed at a temperature of 350 ℃ for one second was 2 mm, exhibiting the largest transmission illumination of 280 lx. When the transparent acrylic plate was set to a constant size of 1.6 mm at the bottom of the right-angle triangular pyramid, the fastest response occurred at a processing tip temperature of 350 ℃ (0.04 s). On the other hand, it took 10 s to process the size of the bottom of the right-angled triangular pyramid at a temperature of 200 ℃ to 1.6 mm, and it was confirmed that the optical transmission efficiency was significantly reduced because of the burr that occurred at this time.

Influences of Rate of Artificial Insemination Following Estrus Induction in Dog (개에서 발정유도가 인공수정효율에 미치는 영향)

  • 이영락;강태영;최상용
    • Journal of Embryo Transfer
    • /
    • v.18 no.1
    • /
    • pp.61-68
    • /
    • 2003
  • Considerable attention has been focused on the cryopreservation of semen and estrus induction in dog, as consequence of poor productivity caused by long anestrus period, in order to enhance the productivity of youngs and to preserve the breeds. The objectives of this study were to improve reproductive efficiency of artificial insemination with fresh- and frozen-semen following estrus induction in dog. Fifty infertilie dogs (age 2~3 years) were selected fur the study and divided into three different estrus induction treatment groups. Group 1 : dogs (n=15) were given clomifene (0.1 mg/kg) orally f3r five days at 12 hr intervals. Croup 2: dogs (n=15) were given bromocriptine (50 $\mu$g/kg) orally for five days at 12 hr intervals, followed by single injection intravenously of 500 IU GnRH (Croup 3, n=20) when pro-estrus occurred. After being treated, the dogs were evaluated fur the rates of estrus induction and time interval lapses from treatment to beginning of the pro-estrus. The rates of pregnancy in estrus inducted dogs mated naturally compared to those inseminated artificially with ejaculated fresh semen and frozen-thawed semen. Estrus detection was performed using the method of vaginal smear and confirmed by the plasma progesterone assay. Pregnancy was confirmed by ultrasonograpy on day 25, 35 and 55 post insemination. The ejaculated semen was exposed to a mixture of Tris extender with cryoprotectant (Trisma, 81 mM; TES, 209 mM; citric acid, 6 mM; glucose, 5 mM; glycerol, 8%) and cryopreserved gradually by slow-cooling at 17 co above the surface of liquid nitrogen (L$N_2$) for 23 min. The use of fresh semen, the pregnancy rates were observed 66.6, 66.6, 75.0 and 83.3% in natural estrus, clomifene induced, bromocriptine induced and a combination of GnRH and bromocriptine, respectively. The use of frozen-thawed semen, the pregnancy rates were observed 66.6, 33.3, 50.0 and 60.0% in natural estrus, clomifene induced, bromocriptine induced and a combination of GnRH and bromocriptine, respectively. No difference was observed in the number of offspring produced among natural estrus and treated groups inseminated with fresh or frozen-thawed semen. In conclusion, there was no significant differences in the pregnancy rate of dogs between group treated with a combination of GnRH and bromocriptine and group treated clomifene or bromocriptine only. However, frozen-thawed semen can be used successfully fur artificial insemination in dog.