• Title/Summary/Keyword: eyes

Search Result 2,535, Processing Time 0.027 seconds

Lens system design for head mounted display using schematic eyes (정밀모형안을 이용한 Head Mounted Display용 렌즈계 설계)

  • 박성찬;안현경
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.236-243
    • /
    • 2003
  • We discussed the design of lens module schematic eyes equivalent to finite model eyes, which are used to model the human eye based on spherical aberration and Stiles-Crowford effect. The optical system for head mounted display (HMD) is designed and evaluated using lens module schematic eyes. In addition to a compact HMD system, an optical system with high Performance is required. To satisfy these requirements, we used diffractive optical elements and aspheric surfaces so that the color and mono-chromatic aberrations were corrected. The optical system for HMD is composed of 0.47 inch micro-display of SVGA grade with 480,000 pixels, a plastic hybrid lens for the virtual image, and the lens module schematic eyes. The designed optical system fulfills the current specifications of HMD: such as, EFL of 31.25 mm, FOV of 24H$\times$18V$\times$30D degrees, and overall length of 59.1 mm. As a result, we could design an optical system useful for HMD; the system is expected to be comfortable while the user wears it.

Relationship between Progressive Changes in Lamina Cribrosa Depth and Deterioration of Visual Field Loss in Glaucomatous Eyes

  • Kim, You Na;Shin, Joong Won;Sung, Kyung Rim
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.470-477
    • /
    • 2018
  • Purpose: To investigate the relationship between the progression of visual field (VF) loss and changes in lamina cribrosa depth (LCD) as determined by spectral-domain optical coherence tomography (SD-OCT) enhanced depth imaging in patients with primary open angle glaucoma (POAG). Methods: Data from 60 POAG patients (mean follow-up, $3.5{\pm}0.7$ years) were included in this retrospective study. The LCD was measured in the optic disc image using SD-OCT enhanced depth imaging scanning at each visit. Change in the LCD was considered to either 'increase' or 'decrease' when the differences between baseline and the latest two consecutive follow-up visits were greater than the corresponding reproducibility coefficient value ($23.08{\mu}m$, as determined in a preliminary reproducibility study). All participants were divided into three groups: increased LCD (ILCD), decreased LCD (DLCD), and no LCD change (NLCD). The Early Manifest Glaucoma Trial criteria were used to define VF deterioration. Kaplan-Meier survival analysis and Cox's proportional hazard models were performed to explore the relationship between VF progression and LCD change. Results: Of the 60 eyes examined, 35.0% (21 eyes), 28.3% (17 eyes), and 36.7% (22 eyes) were classified as the ILCD, DLCD, and NLCD groups, respectively. Kaplan-Meier survival analysis showed a greater cumulative probability of VF progression in the ILCD group than in the NLCD (p < 0.001) or DLCD groups (p = 0.018). Increased LCD was identified as the only risk factor for VF progression in the Cox proportional hazard models (hazard ratio, 1.008; 95% confidence interval, 1.000 to 1.015; p = 0.047). Conclusions: Increased LCD was associated with a greater possibility of VF progression. The quantitative measurement of LCD changes, determined by SD-OCT, is a potential biomarker for the prediction of VF deterioration in patients with POAG.

Correlation between nasal mucosal thickness around the lacrimal sac fossa and surgical outcomes in endonasal dacryocystorhinostomy

  • Yoo, Jae Ho;Kim, Chang Zoo;Nam, Ki Yup;Lee, Seung Uk;Lee, Jae Ho;Lee, Sang Joon
    • Kosin Medical Journal
    • /
    • v.33 no.3
    • /
    • pp.358-368
    • /
    • 2018
  • Objectives: To identify the relationship between surgical success rate and preoperative nasal mucosal thickness around the lacrimal sac fossa, as measured using computed tomography. Methods: We reviewed 33 eyes from 27 patients who underwent endoscopic dacryocystorhinostomy after diagnosis of primary nasolacrimal duct obstruction and who were followed-up with for at least six months between 2011 and 2014. We measured preoperative nasal mucosal thickness around the bony lacrimal sac fossa using computed tomography and analyzed patient measurements after classifying them into three groups: the successfully operated group, the failed operation group, and the non-operated group. Results: Surgery failed in six of the 33 eyes because of a granuloma at the osteotomy site and synechial formation of the nasal mucosa. The failed-surgery group showed a clinically significantly greater decrease in nasal mucosal thickness at the rearward lacrimal sac fossa compared with the successful-surgery group. However, nasal mucosal thickness of fellow eyes (i.e., non-operated eyes) was not significantly different between the two groups, and the location of the uncinate process did not appear to influence mucosal thickness. In the failed group, posteriorly located mucosal thickness of operated eye fossa was thinner than that of the non-operated eyes, but not significantly so. Conclusions: Our results from this quantitative anatomical study suggest that nasal mucosal thickness is a predictor of endoscopic dacryocystorhinostomy results.

Changes in facial surface temperature of laying hens under different thermal conditions

  • Kim, Na Yeon;Kim, Seong Jin;Oh, Mirae;Jang, Se Young;Moon, Sang Ho
    • Animal Bioscience
    • /
    • v.34 no.7
    • /
    • pp.1235-1242
    • /
    • 2021
  • Objective: The purpose of this study was to identify through infrared thermal imaging technology the facial surface temperature (FST) of laying hens in response to the variations in their thermal environment, and to identify the regional differences in FST to determine the most stable and reliable facial regions for monitoring of thermoregulatory status in chickens. Methods: Thirty Hy-Line Brown hens (25-week-old) were sequentially exposed to three different thermal conditions; optimal (OT, 22℃±2℃), low (LT, 10℃±4℃), and high temperature (HT, 30℃±2℃). The mean values of FST in five facial regions including around the eyes, earlobes, wattles, beak and nose, and comb were recorded through infrared thermography. The maximum FST (MFST) was also identified among the five face-selective regions, and its relationship with temperature-humidity index (THI) was established to identify the range of MFST in response to the variations in their thermal environment. Results: Hens exposed to OT condition at 15:00 displayed a higher temperature at wattles and around the eyes compared to other regions (p<0.001). However, under LT condition at 05:00 to 08:00, around the eyes surface temperature showed the highest value (p<0.01). In HT, wattles temperature tended to show the highest temperature over almost time intervals. Main distribution regions of MFST were wattles (63.3%) and around the eyes (16.7%) in OT, around the eyes (50%) in LT, and wattles (62.2%) and comb (18.3%) in HT. The regression equation between MFST and THI was estimated as MFST = 35.37+0.2383×THI (R2 = 0.44; p<0.001). Conclusion: The FST and the frequency of MFST in each facial region of laying hens responded sensitively to the variations in the thermal environment. The findings of this experiment provide useful information about the effect of the thermal conditions on the specific facial regions, thus offering an opportunity to stress and welfare assessment in poultry research and industry.

Association of serum 25-hydroxyvitamin D concentrations with Schirmer tear test 1 and tear film breakup time in dogs

  • Youngsam Kim;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.2
    • /
    • pp.32.1-32.10
    • /
    • 2023
  • Background: The association between vitamin D and canine keratoconjunctivitis sicca (KCS) has not been investigated in dogs. Objectives: To investigate the association of serum 25-hydroxyvitamin D [25(OH)D] concentrations with Schirmer tear test 1 (STT-1) and tear film breakup time (TFBUT) in dogs. Methods: Sixty-one clinically healthy, client-owned dogs were enrolled. STT-1 and TFBUT were measured in 122 (61dogs) and 82 (41 dogs out of total 61 dogs) eyes, respectively. Serum 25(OH)D concentrations were evaluated by quantitative chemiluminescent immunoassay. The dogs were classified into 6 groups according to the evaluations (STT-1: group 1, normal [≥ 15 mm/min] in both eyes; group 2, normal in one eye and abnormal [< 15 mm/min] in the fellow eye; group 3, abnormal in both eyes; TFBUT: group 4, normal [≥ 20 sec] in both eyes; group 5, normal in one eye and abnormal [< 20 sec] in the fellow eye; group 6, abnormal in both eyes). Results: STT-1 was positively correlated with TFBUT (p < 0.001). Among the STT-1 groups, the mean serum 25(OH)D concentration in group 1 was significantly higher than in groups 2 and 3 with positive correlation (p < 0.001). However, there were no significant differences among the TFBUT groups 4, 5, and 6. Conclusions: In dogs, it was found that serum 25(OH)D concentrations had a greater effect on quantitative KCS than qualitative KCS. Therefore, it is considered that measurement of serum 25(OH)D concentration could be included in the diagnostic tests in canine quantitative KCS patients.

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

Surveying and the Ergonomic Analysis of Eye Dominance (주시(Eye Dominance)에 관한 조사 및 인간공학적 분석)

  • 정화식
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.2
    • /
    • pp.79-89
    • /
    • 2004
  • It is known that most people have a dominant eye, even though each of their two eyes in isolation may provide equal vision. In this study, 600 Korean male and female subjects aging from 11 to 78 were selected to investigate the various statistics about eye dominance( whether the left or right eye is dominant} in Korean and their employment characteristics of preferred eye in sighting diverse things. A simple sighting test was applied such that subjects are requested to aim a distance target through small hole in B4 sized paper with both eyes open. The dominant eye was determined by alternate occlusion: when viewing with the dominant eye into the hole is aligned with the target, whereas when viewing with the other eye into the hole appears offset to one side. The descriptive statistics showed that 83.7% and 16.3% were right and left eye dominant respectively. Moreover, various statistical analysis revealed that general tendency of eye dominance was varied by age, gender, hand dominance and visual acuity. It was thus found from these results that people sighting their eyes differently depending on the eye dominance when they sight things.

Effects of Phenanthrene Exposure on the Acetylcholinesterase Activity of Olive Flounder (Paralichthys olivaceus)

  • Jee Jung-Hoon;Kang Ju-Chan
    • Fisheries and Aquatic Sciences
    • /
    • v.6 no.4
    • /
    • pp.225-227
    • /
    • 2003
  • Acetylcholinesterase (AChE) activity is a potential biomarker for phenanthrene exposure in aquatic organisms. Olive flounder (Paralichthys olivaceus) were exposed to three different concentrations (0.5, 1.0 and 2.0, uM) of phenanthrene for four weeks. AChE activities in the brain, heart and eyes were documented. Inhibition of AChE activity was found significant in flounder treated with a concentration greater than $1.0 {\mu}M$ of phenanthrene. This indicates that a chronic exposure to phenanthrene induces damage in various organs (brain, heart and eyes) and changes of AChE activities might be a useful biomarker to assess the impacts induced by polycyclic aromatic hydrocarbon (PAH). Evidence from this study confirms that the measurement of AChE in the brain and eyes of flounder is a valuable tool that along with other biomarkers can maximize an ecotoxicologists' confidence in assessing the impacts of oil and PAH pollution in the aquatic environment.

Balance Performance of Normal Children and Adults using Tiltboard (경사판을 이용한 정상 성인과 아동의 균형 수행력)

  • Lee Jin-Hee;Kwon Young-Shil;Kim Jin-Sang;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.1
    • /
    • pp.45-53
    • /
    • 1999
  • The purpose of this study Was to describe balance performance of 10 normal children and 10 adults using tilt board under three tasks 1) eyes open with gazing stationary target, 2)eyes dosed, and 3) eyes open with gazing dynamic target. The results were as follows. 1. As increasing the number of trials, balance performance was inclosed, specially, in children group. 2. In children group, there was significant difference between right side and left side in task 2 and task 3.3. In both group. there was significant difference between task2 and task3. 4. There was no difference between adults group and children group.

  • PDF

Subjective appraisal of the appearance on monochromatic light differenced by the eyeball's pigment

  • Muraoka, Tetsuya;Ikeda, Hiroaki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1009-1013
    • /
    • 1990
  • In the Orient, most references are made on the visual perception of the eye having the blue iris, even in the case where the reference should be made on the perception by the eye having the dark iris. In order to clarify the difference in the visual perceptions of a monochromatic light, an objective boundary wavelength between hues incident on the dark eyes was obtained and the correlation between the valuesalready reported as having been obtained with the blue eyes was examined. A significant difference was found in the subjective boundary wavelengths of hues depending on the difference in the visual sensitivity distribution on the dark and blue eyes.

  • PDF