• Title/Summary/Keyword: eye-blink

Search Result 56, Processing Time 0.026 seconds

Relationship between biosignal, raction time, and eye blink depending on arousal level (I) (각성상태에 따른 생리신호와 반응시간 및 눈깜박임의 상관관계 (I))

  • Ko, H.W.;Kim, Y.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.426-429
    • /
    • 1997
  • This paper describes the relationship among physiological, behavioral signal, and subjective evaluation depending on arousal level. Nz and reaction time hall similar pattern with KSS level, but eyeblink rate was different from these two parameters. Eyeblink rate increased slowly from KSS level 1 to 5, and had high increasing rate at KSS 7. But it showed steep descent at KSS level 9. From the result of reaction time test, since human performance was decreased rapidly above the KSS level 5, it is desirable to give a subject some stimulus such as sound or aroma to rise arousal level above the KSS level 3.

  • PDF

Eye Management Program using Detection of Eyes Blink Frequency (눈 깜빡임 수 검출을 이용한 안구 관리 프로그램)

  • Han, Sang-Wook;Won, Ye-Ji;Lee, Hwa-Min
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.05a
    • /
    • pp.693-696
    • /
    • 2019
  • IT 기술은 끊임없는 발전을 거듭하고 있으며 현 인류는 기계와 더불어 살고 있다. Desktop, 스마트폰, 노트북 및 태블릿PC는 물론이고, 스마트 워치와 같은 '웨어러블 디바이스(Wearable Device)'의 등장으로 기계 속 세상에 그들과 함께 살고 있다하여도 과언이 아니다. 단연 잦은 기기 사용으로 인해 가장 영향을 크게 받는 인간의 신체 부위는 '눈'이다. 휴대용 기기(Portable Device)는 휴대에 용이해야 한다는 특징 때문에 그 크기가 점차 작아지고 있다. 따라서 작은 기기에 부착된 화면 역시 크기가 감소하였다. 장시간 작은 화면을 집중하여 보게 되면 눈의 피로가 금방 쌓이게 된다. 이로 인해 안구 건조 증 및 시력 저하 발생률이 증가하게 되는데, 영상처리 기술을 이용하여 안구의 깜박임을 감지하고 일정 수치 이하로 깜박임 횟수가 미달될 경우에 안구 운동을 권장하는 프로그램을 개발 하였다.

Evaluation of the Head Mouse System using Gyro-and Opto-Sensors (각속도 및 광센서를 이용한 헤드 마우스의 평가)

  • Park, Min-Je;Kim, Soo-Chan
    • Journal of the HCI Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.1-6
    • /
    • 2010
  • In this research, we designed the head mouse system for disabled and gamers, a mouse controller which can be controlled by head movements and eye blinks only, and compared its performance with other regular mouse controller systems. The head mouse was moved by a gyro-sensor, which can measure an angular rotation of a head movement, and the eye blink was used as a clicking event of the mouse system. Accumulated errors caused by integral, which was a problem that previous head mouse system had, were removed periodically, and treated as dead zones in the non-linear relative point graph, and direct mouse point control was possible using its moving distance and acceleration calculation. We used the active light sources to minimize the influence of the ambient light changes, so that the head mouse was not affected by the change in external light source. In a comparison between the head mouse and the gazing tracking mouse (Quick Glance), the above method resulted about 21% higher score on the clicking event experiment called "20 clicks", about 25% higher on the dasher experiment, and about 37% higher on on-screen keyboard test respectively, which concludes that the proposed head mouse has better performance than the standard mouse system.

  • PDF

A Survey of Objective Measurement of Fatigue Caused by Visual Stimuli (시각자극에 의한 피로도의 객관적 측정을 위한 연구 조사)

  • Kim, Young-Joo;Lee, Eui-Chul;Whang, Min-Cheol;Park, Kang-Ryoung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.195-202
    • /
    • 2011
  • Objective: The aim of this study is to investigate and review the previous researches about objective measuring fatigue caused by visual stimuli. Also, we analyze possibility of alternative visual fatigue measurement methods using facial expression recognition and gesture recognition. Background: In most previous researches, visual fatigue is commonly measured by survey or interview based subjective method. However, the subjective evaluation methods can be affected by individual feeling's variation or other kinds of stimuli. To solve these problems, signal and image processing based visual fatigue measurement methods have been widely researched. Method: To analyze the signal and image processing based methods, we categorized previous works into three groups such as bio-signal, brainwave, and eye image based methods. Also, the possibility of adopting facial expression or gesture recognition to measure visual fatigue is analyzed. Results: Bio-signal and brainwave based methods have problems because they can be degraded by not only visual stimuli but also the other kinds of external stimuli caused by other sense organs. In eye image based methods, using only single feature such as blink frequency or pupil size also has problem because the single feature can be easily degraded by other kinds of emotions. Conclusion: Multi-modal measurement method is required by fusing several features which are extracted from the bio-signal and image. Also, alternative method using facial expression or gesture recognition can be considered. Application: The objective visual fatigue measurement method can be applied into the fields of quantitative and comparative measurement of visual fatigue of next generation display devices in terms of human factor.

The Effect of Artificial Tear Components on Tear Film Stability of Dry Eyes in the Early Stage of Soft Contact Lenses Wear (소프트콘택트렌즈를 착용한 건성안의 착용초기 눈물막 안정성에 인공눈물 성분 조성이 미치는 영향)

  • Kim, So Ra;Lim, Jung A;Jung, Ji Hye;Byun, Hyun Young;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.191-201
    • /
    • 2016
  • Purpose: In the present study, the effect of artificial tears with different ingredients on tear film stability and subjective symptoms of dry eyes in the early stage of soft contact lenses wear was investigated. Methods: The three kinds of artificial tears and saline solution were respectively applied onto 50 dry eyes which wore soft contact lenses made of etafilcon A. Then, non-invasive tear film break-up time (NIBUT) was measured at every five minutes for 30 minutes right after the instillation of artificial tears, and the changes in blink rate and subjective symptoms were estimated after 30 minutes from the instillations. Results: All three kinds of artificial tears increased NIBUT larger than saline. The effect of increasing NIBUT immediately after the instillation of artificial tears was the largest when the artificial tear containing viscosity enhancer was used. The duration time of the effect was the longest when the artificial tear having both surfactant and viscosity enhancer was applied. The blink rate was not significantly changed when both artificial tears and saline solution were instilled. Subjective symptoms were significantly improved by the instillation of both artificial tears and saline solution and dryness, irritation, tiredness, stiffness, dazzling were improved by the use of most solutions. However, the subjective symptoms were rebounded to the level before the instillation of artificial tears after 30 minute-instillation. Conclusions: It was revealed that both artificial tears and saline solution could improve the subjective symptoms of dry eye in the early stage of soft contac lenses however, the effect of these solutions on the tear film stability was different according to the components. From the results, it is suggested that the proper selection of artificial tears is necessary for the improvement of dry eye symptoms at the early stage of soft contact lenses wear in dry eye.

The Comparative Analysis for the Progression of Dry Eyes Caused by Wearing Soft Contact Lenses(SCL) and Cosmetic Soft Contact Lenses(C-SCL) (소프트 콘택트렌즈와 미용 콘택트렌즈의 건성안 진행에 대한 비교분석)

  • Kim, Myoung-Jin;Hwang, Hye-Kyung;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.375-381
    • /
    • 2011
  • Purpose: The purpose of this research was to see how wearing either a SCL or a C-SCL effected the dryness of a person's eye depending on how long they wear either type of lens. Methods: This study was carried out on 52 subjects (104 eyes) who were all in their twenties and had previously experienced wearing contact lenses. All of these subjects were required to wear either a SCL or a C-SCL, which were made out of the same material, for three months. Contents such as the McMonnies Questionnaire survey, the blinking rate per min. and the Noninvasive tear break-up time test (NIBUT) were later conducted on the subjects for this study. Results: According to the results of the McMonnies Questionnaire, it was concluded that the longer the subject wore the SCL and C-SCL, the value of the measurements gradually increased. On the other hand, the results from the NIBUT concluded that the longer the subject wore the SCL, the value of the measurements eventually decreased. However, according to the measurements of the blink rate test, it was concluded that neither results had a significant change. Conclusions: It was concluded that long-term wearing of SCL and C-SCL could be the cause of the induction and progression of dry eyes.

New Treatment in Facial Nerve Palsy Caused by Sagittal Split Ramus Osteotomy of Mandible

  • Lee, Jin Hoon;Lee, Kyung Ah
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.1
    • /
    • pp.65-70
    • /
    • 2017
  • A 25-years-old woman with mandibular prognathism underwent a mandibular setback by way of mandibular sagittal split ramus osteotomy (MSSRO). After 2 days of operation, she developed difficulty of closing her right eye. The blink reflex test and motor nerve conduction study of the right orbicularis oris muscle were revealed right facial neuropathy of unknown origin and House-Brackmann facial nerve grading system (HBFNGS) grade V. For treatment, we initially prescribed oral prednisolone and nimodipine including physical therapy. The samples consisted of 11 facial nerve palsy patients caused by MSSRO and were analysed about onset of facial nerve palsy, postoperative HBFNGS, final HBFNGS, treatment method and recovery time. At 10 weeks of treatment of nimodipine, she had completely regained normal function (HBFNGS grade I) of the right facial nerve. The clinical results lead to assume a fast recovery of facial nerve function by the nimodipine medication, whereas average time of recovery is 16.32 weeks in references. Despite of the limited one patient treated, the result was very promising with respect to a faster recovery of the facial nerve function. Considering the use of nimodipine treatment for peripheral facial nerve palsy following a surgical approach with an anatomically preserved nerve can be recommended.

A Study on the Development of Drowsiness Warning System for a Drowsy Driver (졸음 운전자를 위한 졸음 각성 시스템의 개발에 관한 연구)

  • Chong, K.H.;Kim, H.S.;Lee, J.S.;Kim, B.J.;Kim, D.W.;Kim, N.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.90-94
    • /
    • 1996
  • We studied the problem of driver's low vigilance state which is related to the one reason of traffic accidents. In this paper, we developed the drowsiness warning system for a drowsy driver. To extract the eyes and mouth from the driver's facial image in real time, a computer vision method was used. The eye blink duration and yawning were used as measurement parameters of drowsiness detection. When the drowsy state of a driver was detected, the driver was refreshed by the scent generator and the alarm. Also, the driver's bio-signal was acquired and analyzed to measure the vigilance state.

  • PDF

Electrooculography Filtering Model Based on Machine Learning (머신러닝 기반의 안전도 데이터 필터링 모델)

  • Hong, Ki Hyeon;Lee, Byung Mun
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.2
    • /
    • pp.274-284
    • /
    • 2021
  • Customized services to a sleep induction for better sleepcare are more effective because of different satisfaction levels to users. The EOG data measured at the frontal lobe when a person blinks his eyes can be used as biometric data because it has different values for each person. The accuracy of measurement is degraded by a noise source, such as toss and turn. Therefore, it is necessary to analyze the noisy data and remove them from normal EOG by filtering. There are low-pass filtering and high-pass filtering as filtering using a frequency band. However, since filtering within a frequency band range is also required for more effective performance, we propose a machine learning model for the filtering of EOG data in this paper as the second filtering method. In addition, optimal values of parameters such as the depth of the hidden layer, the number of nodes of the hidden layer, the activation function, and the dropout were found through experiments, to improve the performance of the machine learning filtering model, and the filtering performance of 95.7% was obtained. Eventually, it is expected that it can be used for effective user identification services by using filtering model for EOG data.

A Study on Reconciliation of Observation Data of Interior Space and Feasibility of its Analysis Process (실내공간 주시 데이터의 보정과 분석과정 타당성에 관한 연구)

  • Kim, Jong-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.3
    • /
    • pp.135-142
    • /
    • 2011
  • There occurs subtle shaking in our eyes while in looking at objects and this study sets up the standard of reconciliation from the property of observation and organizes the property of data reconciliation by the observation range to secure the feasibility of reconciliation range and method of the original data obtained from observation experiment and its analysis process. The results from above study can be concluded as in the followings: First, it made clear the process to exclude eye blink and data out of image range from the original data so to set up the range of available data. Second, on the basis of existing theory, it was possible to define the minimum attention time as 0.1 second (3 times of observation) and the visual understanding time of space as 0.3 second (9 times of observation) in the study on the property of observation, and this definition of observation time of sight fixation becomes an important indicator in the analysis of observation data. Third, based on the observation theory of continuity securing and attention, it was able to arrange the standard of reconciliation by carrying out reconciliation works only when fixed data with more than three times of observation showed consecutively before and behind the data with intermittent movements. Fourth, In the sector whether visual understanding occurred (more than 9 times), it increased by 12% for the frequency of observation and by 7.8% for the times of observation compared with the ones before the reconciliation. These results showed to have a constant change by subjects so that it was able to arrange a foundation to secure objective data in the analysis of the observation range and its extent.