• Title/Summary/Keyword: eye drop

Search Result 37, Processing Time 0.024 seconds

The Experimental study of safety and efficacy in using Soyeom Pharmacopuncture solution as eyedrops (점안용 소염약침액의 안전성 및 유효성 평가)

  • Kang, Eun-Kyo;Seo, Hyung-Sik
    • Journal of Pharmacopuncture
    • /
    • v.12 no.1
    • /
    • pp.21-33
    • /
    • 2009
  • Objective : This experimental study was performed to investigate the safety of Soyeom Pharmacopunture solution manufactured by extraction of alcohol and water. To identify the use of it as eyedrops, the eye irritation test of rabbits and antibacterial test of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans was performed. Methods : 1. The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Soyeom pharmacopuncture solution was administered in the left eye of the rabbits, eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 2. After administering Soyeom Pharmacopuncture solution on bacterial species (Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) which cause Keratitis, MIC(Minimum Inhibition Concentration) and the size of inhibition zone were measured. Anti-bacterial potency was also measured using the size of inhibition zone. Results : 1. After Soyeom pharmacopuncture solution was administered in the left eye of the rabbits, it was found that none of nine rabbits have abnormal signs and weight changes. 2. After Soyeom pharmacopuncture solution was medicated in the left eye of the rabbits, no eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 3. There was no response to MIC on bacterial species (Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) after Soyeom pharmacopuncture solution was medicated. Conclusions : The present study suggests that Soyeom pharmacopuncture solution is a non-toxic and non-irritant medicine, which does not cause eye irritation in rabbits, but dosen't have anti-bacterial effects on bacterial species which cause Keratitis. These study result recommends that more research on other herbal medicines of eye drop for Keratitis are required.

Evaluation on Clinical Application of Osmotic Pump with Dorzolamide in Normal Dogs

  • Kwon, Yonghwan;Kim, Jury;Kim, Min-Su
    • Journal of Veterinary Clinics
    • /
    • v.36 no.6
    • /
    • pp.325-329
    • /
    • 2019
  • This study was designed to compare the effects of continuous release of an anti-glaucoma drug applied by an osmotic pump and by conventional eye drop instillation in normal beagle dogs, by measuring drug concentration in the blood and monitoring intra-ocular pressure (IOP). In group 1, an osmotic pump filled with Trusopt® was implanted subcutaneously over the right eye of each dog and the IOP was measured. In group 2, the right eye of each dog was administered with 2% dorzolamide (Trusopt®, Merck, USA) three times per day. Blood was sampled once per week in all groups. The IOP of the end of this study was 16.7 ± 0.58 mmHg in group 2 and 17.7 ± 2.52 mmHg in group 2. Dorzolamide concentration in blood increased continuously over 4 weeks up to 585.8 ± 79.42 ㎍/L in group 1, and 747.3 ± 27.89 ㎍/L in group 2. We achieved satisfactory results in the osmotic pump group, which had a similar effect on IOP, and low fluctuations in IOP. Therefore, the results of this study should allow osmotic pumps to be consider as an alternative method to eye drops for the effective, safe, and convenient treatment of glaucoma.

Variation of Lactate Dehydrogenase Isozymes in Angelfish (Pterophyllum scalare) according to Acute Environmental Change (급격한 환경변화에 대한 angelfish (Pterophyllum scalare) 젖산탈수소효소 동위효소의 변화)

  • An, Chang-Su;Cho, Sung-Kyu;Yum, Jung-Joo
    • Journal of Life Science
    • /
    • v.20 no.3
    • /
    • pp.416-423
    • /
    • 2010
  • In this study, the properties and gene expression of the lactate dehydrogenase (EC 1.1.1.27, LDH) isozyme were studied in angelfish (Pterophyllum scalare) - known for their adaptation to the low oxygen environment of the tropics - which were acclimated to acute temperature change ($27{\pm}0.5{\rightarrow}18{\pm}0.5^{\circ}C$) and dissolved oxygen (DO) change ($6{\pm}1{\rightarrow}18\;ppm$) for 2 hours. The properties of the LDH isozymes were confirmed in the native-polyacrylamide gel electrophoresis, Western blot analysis and enzyme activity measurement. Liver- and eye-specific Ldh-C gene were expressed in liver, eye and brain tissues. Through Western blot analysis, the LDH $A_4$ isozyme was shown to have a more cathodal mobility relative to the $B_4$ isozyme. In the liver tissue, the LDH $A_4$ isozyme increased with temperature drop while the $B_4$ isozyme decreased. The LDH $A_4$ and $C_4$ isozymes increased with DO increment, while the $B_4$ isozyme decreased. In the eye tissue, the LDH $A_4$ and B4 isozymse increased with temperature drop while the $B_4$ isozyme decreased. The LDH $A_4$ and $B_4$ isozymes increased with DO increment, but the $C_4$ isozyme and isozymes including the subunit C decreased. In the heart tissue, LDH activity increased with DO increment, as well as the LDH $B_4$ isozyme. In the brain tissue, the LDH $A_4$ and $B_4$ isozymes increased with temperature drop. The LDH $B_4$ isozyme increased with DO increment. Accordingly, since the liver- and eye-specific Ldh-C are influenced by changes in DO and the LDH $B_4$ and $C_4$ isozymes are relatively controlled in the liver and eye tissues, the $C_4$ isozyme can be considered to have a lactate oxidase function.

"Letter-Box" Conjunctival Flap in a Dog with Severe Corneal Edema after Phacoemulsification

  • Sunhyo Kim;Dohyoung Kwon;Kangmoon Seo;Seonmi Kang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.152-157
    • /
    • 2023
  • A two-year-old, spayed female, Bichon Frise, was referred for severe corneal edema and corneal ulcer in the left eye (OS). The cornea had gradually swelled over one week after phacoemulsification performed a month prior, and that was refractory to 5% sodium chloride eye drop instillation or temporary partial tarsorrhaphy. A complete ophthalmic examination was performed. Severe corneal edema with intrastromal bullae and moderate anterior chamber flare was found on slit-lamp biomicroscopy in the OS, which obstructed the fundus examination. Corneal thickness was measured using high-resolution ultrasound biomicroscopy. The thickness of the OS cornea was 2.74 mm. The "letter-box" conjunctival flap was planned. Dorsal and ventral superficial keratectomy followed by a hood conjunctival flap was performed. Topical and systemic antibiotics and 5% sodium chloride eye drops were prescribed. Decreased corneal thickness was observed at one week, two weeks, and two months postoperatively (1.53 mm, 1.32 mm, and 0.92 mm, respectively). There were no postoperative complications, such as ocular discomfort or recurrent corneal ulcers. The "letter-box" conjunctival flap, a type of superficial keratectomy and conjunctival advancement hood flap, effectively relieved the severe irreversible corneal edema. This could be a simple but effective surgical intervention for patients with endothelial cell damage especially after phacoemulsification.

Prophylactic effect of topical betaxolol and dorzolamide on the fellow eye in unilateral canine primary angle closure glaucoma: 60 cases (2016.1-2021.5)

  • Ahn, Junyeong;Kang, Seonmi;Shim, Jaeho;Jeong, Youngseok;Lee, Songhui;Lee, Eunji;Seo, Kangmoon
    • Korean Journal of Veterinary Research
    • /
    • v.62 no.3
    • /
    • pp.26.1-26.7
    • /
    • 2022
  • This study was aimed to evaluate the prophylactic anti-glaucoma effect of topical 5% betaxolol (BTX) and 2% dorzolamide (DRZ) on the second eye in dogs with unilateral primary angle closure glaucoma (PACG). Medical records of 60 dogs with unilateral PACG who received prophylactic anti-glaucoma eyedrops in the second eye, from 2016 to 2021, were reviewed. The prophylactic effects of BTX were maintained on 28/60 (46.7%) eyes until last visit and BTX failure was observed on median 510 (range, 53-1,927) days in 32/60 (53.3%) eyes. After DRZ instillation in BTX failure eyes, the prophylactic effects were extended at median 610 (range, 157-2,270) days in 21/32 (65.6%) eyes. DRZ failure eyes (17/21, 81.0%) eyes required chemical ablation or surgical intervention due to uncontrolled intraocular pressure. The duration of prophylactic effects was decreased with aging (R2 = 0.334, p = 0.006). The predominant breeds were Shih-Tzu (41.9%) and American Cocker Spaniel (30.6%) with no significant differences in survival curves (p = 0.210). The average prophylactic effects of BTX persisted more than 1.5 year and could be selected the first prophylactic eye drop in unilateral PACG. Also, early surgical intervention should be considered in prophylactic medications failure cases.

The effects of PEP-1-FK506BP on dry eye disease in a rat model

  • Kim, Dae Won;Lee, Sung Ho;Ku, Sae Kwang;Lee, Ji Eun;Cha, Hyun Ju;Youn, Jong Kyu;Kwon, Hyeok Yil;Park, Jong Hoon;Park, Eun Young;Cho, Sung-Woo;Han, Kyu Hyung;Park, Jinseu;Eum, Won Sik;Choi, Soo Young
    • BMB Reports
    • /
    • v.48 no.3
    • /
    • pp.153-158
    • /
    • 2015
  • As FK506 binding proteins (FK506BPs) are known to play an important role in the regulation of a variety of biological processes related to cell survival, this study was designed to examined the protective effects of FK506 binding protein 12 (FK506BP) on low humidity air flow induced dry eye in a rat model using transduced PEP-1-FK506BP. After the topical application of PEP-1-FK506BP, tear volumes were markedly increased and significant prevention of cornea damage was observed compared with dry eye rats. Further, immunohistochemical analysis demonstrated that PEP-1-FK506BP markedly prevented damage to the cornea, the bulbar conjunctiva, and the palpebral conjunctiva epithelial lining compared with dry eye rats. In addition, caspase-3 and PARP expression levels were found to be decreased. These results demonstrated that topical application of PEP-1-FK506BP significantly ameliorates dry eye injury in an animal model. Thus, we suggest that PEP-1-FK506BP can be developed as a new ophthalmic drop to treat dry eye diseases.

Study on Dual-Lenses Actuator for HD-DVD System (차세대 DVD 시스템용 Actuator 연구)

  • Kim, Seok-Jung;Lee, Yong-Hoon;Ahn, Young-Man;Chung, Chong-Sam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.777-781
    • /
    • 2002
  • Recently, an optical disc system has been proposed using blue laser diode, high NA objective lens and groove only disc structure. A new method is needed to readout CD and DVD in this blue system. In order to readout CD and DVD in HD-DVD system, we adopted dual-lenses actuator in consideration of optical utilization efficiency, optical performance and insurance of sufficient W.D (working distance). This dual-lenses actuator has two objectives in radial direction, one is for CD/DVD and the other is for HD-DVD. We had to solve the induced problems of DC tilt increase, $2^{nd}$ resonance deterioration and AC sensitivity drop caused by disposing two lenses in an actuator. Especially, to solve AC sensitivity drop, we introduced two 2-pole magnets and separated focus and track magnetic circuits. Consequently we presented that dual-lenses actuator has been possessed good performance. And we measured eye patterns of CD, DVD and HD-DVD by using HD-DVD optical pick-up with dual-lenses actuator.

  • PDF

Analysis of Electrical Characteristics of Amorphous Silicon Thin Film Photovoltaic Module Exposed Outdoor (옥외 설치된 비정질 실리콘 박막태양전지모듈의 전기적 출력 특성 분석)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.62-67
    • /
    • 2008
  • In this study, we analyze the electrical characteristics of amorphous silicon thin film photovoltaic module which are installed about 5 years ago. Four modules from PV system are extracted and measured the maximum power change ratio using solar simulator(Class A). Also, infrared camera is used to get thermal distribution characteristics of system. The external appearance change is compared with initial module by naked eye examination. Through this experiment, 31% maximum output power drop is observed. The detail description is specified as the following paper.

Gaze Detection System by IR-LED based Camera (적외선 조명 카메라를 이용한 시선 위치 추적 시스템)

  • 박강령
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.4C
    • /
    • pp.494-504
    • /
    • 2004
  • The researches about gaze detection have been much developed with many applications. Most previous researches only rely on image processing algorithm, so they take much processing time and have many constraints. In our work, we implement it with a computer vision system setting a IR-LED based single camera. To detect the gaze position, we locate facial features, which is effectively performed with IR-LED based camera and SVM(Support Vector Machine). When a user gazes at a position of monitor, we can compute the 3D positions of those features based on 3D rotation and translation estimation and affine transform. Finally, the gaze position by the facial movements is computed from the normal vector of the plane determined by those computed 3D positions of features. In addition, we use a trained neural network to detect the gaze position by eye's movement. As experimental results, we can obtain the facial and eye gaze position on a monitor and the gaze position accuracy between the computed positions and the real ones is about 4.2 cm of RMS error.

Study of IoT Module Package Design Optimization for Drop Testing by Drone (IoT 모듈 패키지 디자인 최적화 및 드론에서의 낙하해석 연구)

  • Jo, Eunsol;Kim, Gu-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.4
    • /
    • pp.63-67
    • /
    • 2021
  • In order to detect fires that may not be visible to the naked eye, an IoT module that uses changes in Carbon dioxide (CO2) levels and temperature to effectively identify ambers (dying flames) was developed. Finite element analysis was then used to optimize the packaging for this module. Given the nature of ambers, the low power long range LoRa (Long Range) technology was used in the development of this module. To protect the module, a number of packages were designed, and comparative analysis performed on the stress generated when they fall. The results of which show that Model C showed the lowest stress. In addition, unlike other models in which stress concentration was predicted in the module mounting part of the package, in this model the stress concentration phenomenon was predicted in the wing part. It was therefore determined that this approach is ideal for protecting the internal module, and a package to which this was applied was manufactured.