• Title/Summary/Keyword: eye

Search Result 5,392, Processing Time 0.037 seconds

A New Confidence Measure for Eye Detection Using Pixel Selection (눈 검출에서의 픽셀 선택을 이용한 신뢰 척도)

  • Lee, Yonggeol;Choi, Sang-Il
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.7
    • /
    • pp.291-296
    • /
    • 2015
  • In this paper, we propose a new confidence measure using pixel selection for eye detection and design a hybrid eye detector. For this, we produce sub-images by applying a pixel selection method to the eye patches and construct the BDA(Biased Discriminant Analysis) feature space for measuring the confidence of the eye detection results. For a hybrid eye detector, we select HFED(Haar-like Feature based Eye Detector) and MFED(MCT Feature based Eye Detector), which are complementary to each other, as basic detectors. For a given image, each basic detector conducts eye detection and the confidence of each result is estimated in the BDA feature space by calculating the distances between the produced eye patches and the mean of positive samples in the training set. Then, the result with higher confidence is adopted as the final eye detection result and is used to the face alignment process for face recognition. The experimental results for various face databases show that the proposed method performs more accurate eye detection and consequently results in better face recognition performance compared with other methods.

Development of Eye Tracker System for Early Childhood (유아용 시선 추적 장치의 개발 연구)

  • Lee, Byungho
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.7
    • /
    • pp.91-98
    • /
    • 2019
  • The purpose of this study was to develop and test an eye tracker focusing on early childhood participants, based on the characteristics of early childhood eye tracking studies. Eye tracking collects eye movement data of the subject, which provides scientific evidence of human cognition and thinking. The researcher built a Do It Yourself eye tracker camera module from general electronic components, and used Viewpoint analysis software from Arrington Research. The researcher compared the eye tracking data between the DIY eye tracker group and Tobii Pro eye tracker group, which provides a professional eye tracking system. Eye tracking data was collected from 52 five-year old children. The average proportion of valid trials between the two groups was compared with t test, and no significant difference was found. This result indicates that the DIY eye tracker can be used to collect valid eye tracking data from young children under certain research environment.

Prototypical Eye Shape Classification to Solve Life-and-Death Problem in Go, using Monte-Carlo Method and Point Pattern Matching (몬테카를로 방법과 점 패턴 매칭을 활용한 바둑에서의 사활문제 해결을 위한 원형 안형의 분류)

  • Lee, Byung-Doo
    • Journal of Korea Game Society
    • /
    • v.21 no.6
    • /
    • pp.31-40
    • /
    • 2021
  • Go has a history of more than 2,500 years, and the life-and-death problems in Go is a fundamental problem domain that must be solved when implementing a computer Go. We attempted to determine the numbers of prototypical eye shapes with 3, 4, 5, and 6 eyes that are directly related to the life-and-death problems, and to classify the prototypical eye shapes represented in 4-tuple forms. Experiment was conducted by Monte-Carlo method and point pattern matching. According to the experimental results, the numbers of prototypical eye shapes were 2 for 3-eye, 5 for 4-eye, 12 for 5-eye, and 35 for 6-eye shapes. Further, using a 4-tuple form, we classified prototypical eye shapes into 1 for 3-eye, 3 for 4-eye, 4 for 5-eye, and 8 for 6-eye shapes.

Comparison of the Effectiveness of Herbal Medicine Eye Drops on Conjunctivitis : A Systematic Literature Review and Meta-Analysis (결막염에 대한 한방 점안액의 효과 비교 : 체계적 문헌 고찰과 메타 분석)

  • Lim, Hui-Yeong;Kim, Jee-Hee;Ko, Woo-Shin;Yoon, Hwa-Jung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.35 no.3
    • /
    • pp.48-65
    • /
    • 2022
  • Objectives : This study was conducted to find out the effectiveness and safety of herbal medicine eye drops on conjunctivitis. Methods : We searched randomized controlled trials on conjunctivitis through 10 DBs from the start to April 27, 2022. Study collection and data extraction, and evaluation of risk of bias were conducted by two independent researchers. The evaluation of the risk of bias in included RCTs was carried out by using Cochrane risk-of-bias tool. And the data synthesis was conducted by using Review Manager(RevMan, ver.5.4). Results : Total of 106 studies are researched and 7 studies of them are finally included. 1. The herbal medicine eye drops are more effective on than the western medicine eye drops, but the heterogeneity was very high. So we conducted sensitivity analysis and compared to the herbal medicine eye drops and the western medicine eye drops, the total effective rate was higher in the herbal medicine eye drops and the heterogeneity was somewhat reduced. 2. In the subgroup analysis, Fufang Xiongdan eye drops and Houttuynia cordata Thunb eye drops are more effective than the western medicine. It may represent substantial heterogeneity. 3. In the subgroup analysis, the herbal medicine eye drops are more effective than antibiotic and antiviral eye drops on acute bacterial conjunctivitis, but showed high heterogeneity. On the other hand, the herbal medicine eye drops are more effective than antibiotic and antiviral eyed drops on acute viral conjuctivitis and showed low heterogeneity. 4. In the subgroup analysis, we compared the effectiveness of herbal and western medicine eye drops according to total effectiveness rate evaluation methods. When comparing the studies calculating the total effective rate by the sum of 'Cured', 'Significantly Impaired', and 'Improved', the effective rate of the herbal medicine eye drops was higher than that of the western medicine eye drops, and the heterogeneity was very low. 5. In most studies, side effects of herbal medicine eye drops were absent or mild. Conclusions : This study shows that herbal medicine eye drops may be more effective than western medicine eye drops and have safety. But further researches are needed to resolve the heterogeneity of this study.

The Corneal Base Curve, Astigmatism, and Power of Women College Students (여대생들의 각막기본 곡률, 난시, 굴절력)

  • Kim, Douk-Hoon;Choi, Ho-Seong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.53-57
    • /
    • 2001
  • The corneal structure and function changes somewhat with aging. We were performed the analysis of women college students on the base curve, power, and astigmatism axis of the cornea by keratometer. All women subjects were between the ages of 19 and 20 years. On the corneal base curve. the right eye of the ages of 19 was 7.64 mm in vertical and 7.81 mm in horizontal. But, the left eye was 7.65 mm in vertical and 7.83 mm in horizontal on the other hand, the right and left eye of the ages of 20 was 7.72 mm in vertical and 7.75 mm in horizontal. On the corneal diopter power, the right eye of the ages of 19 was 44.21 diopter in vertical and 43.32 diopter in horizontal. But, the left eye was 44.23 diopter in vertical and 43.24 diopter in horizontal. On the other hand, the right eye of the ages of 20 was 43.67 diopter in vertical and 43.62 diopter in horizontal. But, the left eye was 43.73 diopter in vertical and 43.6 diopter in horizontal. According to the corneal astigmatism axis style, the right eye of the ages of 19 have 83% positive for with the rule astigmatism, and 16% positive for against the rule astigmatism. But, the left eye of the ages of 19 have 86% positive for with the rule astigmatism, and 12% positive for against the rule astigmatism. On the other hand, the right eye of the ages of 19 have 56% positive for with the rule astigmatism, and 44 % positive for against the rule astigmatism. But, the left eye of the ages of 20 have 56% positive for with the rule astigmatism, and 41% positive for against the rule astigmatism. According to the diopter power of corneal astigmatism. The right eye of the ages of 19 have 36% positive for behind 1 diopter and left eye have 31%. But, the right and left eye of the ages of 20 have 37.5%. The right and left eye of the ages of 19 have 42% positive for 1 diopter, and the right eye of the ages of 20 have 34.4% positive for 1 diopter and the left eye have 43.8%. The right eye of the ages of 19 have 12% positive for 2 diopter and left eye have 22%. But, the right eye of the ages of 20 have 15.6% positive for 2 diopter and the left eye have 12%. The right eye of the ages of 19 have 4% positive for 3 diopter and left eye have 3%. But, the left eye of the ages of 20 have 3% positive for 3 diopter and the left eye have 6%. On the other hand, the right eye of ages of 19 have 6% positive over 4 diopter, and the left eye have 2%. But, the right eye of ages of 20 have only 9% positive over 4 diopter.

  • PDF

The Comparative Research of Dominant Eye and Non-dominant Eye by Ages (연령대별 우세안과 비우세안의 비교 연구)

  • Lee, Wan-Seok;Ye, Ki-Hun;An, Sun-Joung;Shin, Bum-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.203-211
    • /
    • 2013
  • Purpose: When we look at the object, we used the dominant eye mainly. For this reason, a prescription of the dominant eye is an important factor for glasses and contact lenses. This study evaluated visual acuity differences between dominant and nondominant eyes through analyzing refractive power changes in both eyes by the ages. Methods: This study was performed to investigate the relationship between refractive error and dominant eye which had the superiority in the function of binocular. 186 subjects without ocular disease were examined on the dominant eye. The dominant eye was examined by the Hole-in-the-card test. For the consistency of the measurements, we tested refractive power in three times by the same person. Results: Using SPSS, the relationship between vision and the dominant eye was analyzed. 135 people of the whole subjects have the dominant eye on right. The Number of the non-dominant eye is 51. We were divided into 3 types, the group under the age of 10 that begins to expose environment factor affect on vision (the average age $8.8{\pm}1.18$) and the age group of 10 to 20 that begins to change refractive power in earnest (the average age $14.1{\pm}2.58$) and the group after the age 20 that began to stabilize vision (the average age $51.8{\pm}17.51$). The visual acuity of dominant eye was higher than non-dominant eye in all age groups. Nevertheless, these results were not statistically significant. Mean astigmatism of dominant eye was smaller than the non-dominant eye, and this is significant, statistically (p=0.017<0.05). Conclusions: It is expected that the balanced eye with a lower level of astigmatism has a more possibility become a dominant eye.

Fine Structural Analysis of Principal and Secondary Eyes in Wandering Spider, Pardosa astrigera (배회성 거미 (Pardosa astrigera) 주안과 부안의 미세구조적 분석)

  • Jeong, Moon-Jin;Lim, Do-Seon;Moon, Myung-Jin
    • Applied Microscopy
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • The wandering spider, Pardosa astrigera, had four pairs of ocelli that arranged in three rows on the cephalothorax. Along the anterior margin lay a pair of small anterior median (AM) eye flanked on each side by anterior lateral (AL) eye. Two large posterior median (PM) eye was situated on the clypeus behind the anterior row and still more posteriorly was a pair of posterior lateral (PL) eye. The visual cell of retina consisted of cell body, rhabdome, and intermediate segment. Bipolar neuron was found in anterior median eye (principal eye) and unipolar neuron in others (secondary eye). Rhabdome showed that arranged in PMeye and PLeye. But rhabdomes of AMeye and ALeye were irregular in retina. Except AMeye, incontinuous tapetum found in ALeye, PMeye, PLeye. Anterior median eye was similar to anterior lateral eye in length and posterior median eye similar to posterior lateral eye. Component size of eye were similar to 4 pairs eye in cornea. Size of lens, cell body, and rhabdome was similar not only anterior median eye and anterior lateral eye but also posterior median eye and posterior lateral eye. Vitreous body was large posterior median eye than others.

  • PDF

The Experimental Study of Safety and Efficacy in Using Bovis Calculus Pharmacopuncture Solution as Eye Drop (점안용 우황약침액의 안전성 및 유효성 평가)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.12 no.3
    • /
    • pp.61-72
    • /
    • 2009
  • Objectives : This experimental study was performed to investigate the safety and efficacy of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. To identify the use of it as eye drop, the eye irritation test of rabbits and the antibacterial test of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans were performed. Methods : 1. The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Bovis Calculus pharmacopuncture solution was administered in the left eye of the rabbits, eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 2. After administering Bovis Calculus pharmacopuncture solution on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) which cause Keratitis, MIC(Minimum Inhibition Concentration) and the size of inhibition zone were measured. Anti-bacterial potency was also measured using the size of inhibition zone. Results : 1. After Bovis Calculus pharmacopuncture solution was administered in the left eye of the rabbits, it was found that none of nine rabbits have abnormal signs and weight changes. 2. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, no eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 3. There was no response to MIC on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) after Bovis Calculus pharmacopuncture solution was medicated. Conclusions : The present study suggests that Bovis Calculus pharmacopuncture solution is a nontoxic and non-irritant medicine, which does not cause eye irritation in rabbits, but dosen't have antibacterial effects on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) which cause Keratitis. These study result recommends that more research on other herbal medicines of eye drop for Keratitis are required.

Classification between Intentional and Natural Blinks in Infrared Vision Based Eye Tracking System

  • Kim, Song-Yi;Noh, Sue-Jin;Kim, Jin-Man;Whang, Min-Cheol;Lee, Eui-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.601-607
    • /
    • 2012
  • Objective: The aim of this study is to classify between intentional and natural blinks in vision based eye tracking system. Through implementing the classification method, we expect that the great eye tracking method will be designed which will perform well both navigation and selection interactions. Background: Currently, eye tracking is widely used in order to increase immersion and interest of user by supporting natural user interface. Even though conventional eye tracking system is well focused on navigation interaction by tracking pupil movement, there is no breakthrough selection interaction method. Method: To determine classification threshold between intentional and natural blinks, we performed experiment by capturing eye images including intentional and natural blinks from 12 subjects. By analyzing successive eye images, two features such as eye closed duration and pupil size variation after eye open were collected. Then, the classification threshold was determined by performing SVM(Support Vector Machine) training. Results: Experimental results showed that the average detection accuracy of intentional blinks was 97.4% in wearable eye tracking system environments. Also, the detecting accuracy in non-wearable camera environment was 92.9% on the basis of the above used SVM classifier. Conclusion: By combining two features using SVM, we could implement the accurate selection interaction method in vision based eye tracking system. Application: The results of this research might help to improve efficiency and usability of vision based eye tracking method by supporting reliable selection interaction scheme.

A Case of Transpalpebral Enucleation in Shih-tzu with Chronic Unilateral Glaucoma (편측성 만성 녹내장을 지닌 Shih-tzu의 안구적출술 치유예)

  • 정순욱;정월순
    • Journal of Veterinary Clinics
    • /
    • v.16 no.1
    • /
    • pp.203-209
    • /
    • 1999
  • A 4-year-old female Shih-tzu with severe episcleral congestion and buphthalmos in left eye was referred to the Veterinary Teaching Hospital, Chonnam National University in October 1998. During two months in local veterinary clinics, the dog had been treated unsuccessfully with tarsorrhaphy and antibiotics. By history taking, cause of the glaucoma was ascertained as accidental nonpenetrated cornea trauma by owner, Ophthalmic examination revealed that the left eye was buphthalmic with severe episcleral congestion, pain and fever. The direct pupillary light response could not be evaluated in the left eye, but right eye had normal reaction. The intraocular pressure was 4.5 mmHg in the right eye and 33 mmHg in the left eye, as measured with a Schiotz tonometer, Ultrasonographic finding revealed hyperechoic vitrous body and central echofree material. The Schirmer tear test showed 20 mm in the left eye and 8 mm in the right eye. The hematologic examination revealed monocytosis. The initial medical treatment was admitted, but there was no response. Transpalpebral enucleation in the left eye under inhalation anesthesia with enflurane 1.2 vol% in oxygen was performed. The day after operation the left eye ravealed no exudate, and pain, and the systemic vital signs were normal. The prognosis is excellent.

  • PDF