헵탄 풀화재에서 불활성기체 소화농도 (Extinguishing Concentration of Inert Gases in Heptane Pool Fires)

  • 정태희;이의주
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.71-76
    • /
    • 2012
  • The coflow velocity effect on the minimum extinguishing concentration(MEC) was investigated experimentally in heptane cup-burner flames. Various inert gases($N_2$, Ar, $CO_2$, He) were added into the oxidizer to find the critical concentration and the effectiveness of the agents on flame extinction. The experimental results showed that the MECs were increased with increasing coflow velocity for most inert gases except helium, but the higher coflow velocity induced the lower burning rates of heptane. This indicated that the increase of coflow velocity resulted in the decrease of fuel velocity evaporated from fuel surface, and hence the stain rate on the reaction zone was also decreased. In the case of helium as a additive, the extinguishing concentration was independent of the coflow velocity because the heat conductivity was ten times larger than the other inert gases and flow effect by a strain rate might be compensated for heat loss to the surroundings.

가스계 청정소화약제의 소화특성과 첨가제에 따른 영향 (Flame Extinguishing Characteristics of Clean Gaseous Agents and Effects of Additives)

  • 신창섭;김성민
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.95-99
    • /
    • 2008
  • Halon was known as a cause of the ozone layer destruction. In 1987, it was designated as one of the ozone-layer-destroying materials in the Montreal Protocol. Therefore substitutes of Halon agent has been developed including inert gas extinguish system, which is one of the most widely used fire extinguishing system. This study intended to increase the efficiency of inert gas extinguishing agent by using inert gas additives. As IG-541 shows high extinguishing power, the experiment was performed to measure the effects of gaseous additives to it. Cup-burner fire extinguishing apparatus was used with n-Heptane fuel. Among many of pure inert gaseous agents, Helium showed the most excellent extinguishing power. When Helium was added to IG-541, fire extinguishing power was increased and the concentration of oxygen in chimney also risen. By adding Helium to IG-541, the effectiveness of inert gas fire extinguishing system is able to be increased.

대향류 메탄/공기 확산화염에서 복사모델이 소화한계에 미치는 영향 (Effect of Radiation Models on the Suppression Limits in Counterflow Methane/Air Diffusion Flames)

  • 문선여;조재호;황철홍;오창보;박원희
    • 한국화재소방학회논문지
    • /
    • 제28권3호
    • /
    • pp.20-28
    • /
    • 2014
  • 대향류 메탄/공기 확산화염에서 복사모델이 소화한계에 미치는 영향이 수치적으로 검토되었으며, 수치결과의 검증을 위하여 기초실험이 병행되었다. 소화약제로는 $N_2$$CO_2$가 고려되었으며, 다른 정확도를 갖는 복사모델 OTM과 SNB에 따른 소화농도의 차이가 검토되었다. 주요 결과로서, $N_2$가 첨가된 경우, 복사모델의 정확도에 따라 소화농도의 큰 차이가 발생되지 않는다. 그러나 강한 복사효과를 갖는 $CO_2$가 낮은 신장율의 화염에 첨가되었을 때, SNB와 같은 예측 정확도가 높은 복사모델이 고려되어야 한다. 특히 연료에 첨가된 $CO_2$의 경우 복사모델 SNB와 OTM에 의한 소화농도는 차이를 갖게 된다. 따라서 소화농도 예측을 위해서는 수치해의 정확도와 계산시간을 고려한 합리적인 복사모델의 선택이 필수적이라 할 수 있다.

K2CO3가 흡착된 합성제올라이트 구조체의 소화농도에 관한 연구 (A Study on Extinguishing Concentration of K2CO3-Zeolite Composites)

  • 김승일;신창섭
    • 한국화재소방학회논문지
    • /
    • 제26권4호
    • /
    • pp.42-47
    • /
    • 2012
  • 본 연구에서는 입자크기 및 밀도가 비교적 작고 소화효과에 있어서 부촉매효과를 나타내는 다공성 흡착제인 합성제올라이트에 $K_2CO_3$를 중량비에 따라 흡착시킨 구조체의 소화농도를 측정하였다. 그리고 구조적 특성을 파악하고자 주사전자 현미경(SEM)의 측정 및 X-Ray 회절분석, 열분석 등을 실시하였다. 흡착구조체의 소화농도실험에서 중량비에 관계없이 순수 $K_2CO_3$의 소화농도보다 모두 낮게 나타났다. 그리고, 특히 $K_2CO_3$와 합성제올라이트의 중량비가 7 : 3인 경우는 소화농도가 5.72배 낮게 측정되었고 ABC분말소화약제보다 약 1.1배 낮게 나타났다. SEM 사진 및 XRD 회절패턴분석을 통해 $K_2CO_3$가 합성제올라이트에 흡착되었다는 것을 알 수 있었고, 열분석을 통해 흡착구조체가 순수 $K_2CO_3$보다 소화에 긍정적인 영향을 미쳤을 것이라 추정할 수 있었다.

간이스프링클러 설비의 소화성능 향상에 관한 실험적 연구 (An Experimental Study on Improvement of Fire Extinguishing Performance of Basic Sprinkler System)

  • 허민녕;신창섭
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.46-51
    • /
    • 2018
  • A basic sprinkler system is a fire extinguishing system that can be easily installed in a fire-vulnerable place such as a publicly used establishments. However, the publicly used establishments are not only complicated in structure, but also have a large amount of flammable interior materials, and the users are not normally in a normal state, which is a very dangerous fire-fighting object. Therefore, due to the low fire extinguishing performance of the basic sprinkler system installed in the publicly used establishments, the fire suppression control can not be performed quickly in case of fire, which may increase the life and property damage. In this study, the cases of quantitative changes of extinguishing water used in basic sprinkler system and the cases of addition of additives such as wetting agents, reinforced agents to improve extinguishing performance were compared. Experimental results showed that the extinguishing performance was improved as the quantity of extinguishing water increase and the reinforced agents showed similar performance to that of 60% increase in the amount of extinguishing water. The cooling time to $200^{\circ}C$ and oxygen concentration were improved up to 14.3% and 34.5%, respectively. In the case of using the wetting agent, the cooling time to $200^{\circ}C$ and oxygen concentration did not show any significant improvement, but showed the effect of preventing deep seated fire. In order to prevent loss of life and property, it is necessary to improve the performance of the basic sprinkler system by increasing amount of extinguishing water or using additives like reinforced agents.

제트확산화염 소화농도의 비정상 유동효과 (Unsteady Flow Effects on Extinguishing Concentrations in Jet Diffusion Flames)

  • 지정훈;오창보;이의주
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.27-31
    • /
    • 2009
  • An experimental study on the unsteady effect of the extinction limit was performed in ethene jet diffusion flames. To impose the unsteadiness on jet flames, the amplitude and frequency of a co-flow velocity was varied, and the two inert gases, $N_2$ and $CO_2$, were used to dilute the oxidizer for extinguishing concentration. The experimental results shows that large amplitude of velocity induces a low extinguishing concentration, which implies that flow variation affects the blow out mechanism. Also, the flow oscillation effects under high frequency attenuates the flame extinction. These results means that flow unsteadiness extends the extinction limit and finally minimum extinction concentration by inert gases. When the Stoke's 2nd Problem is introduced to explain the flow unsteadiness on extinction concentration, the solution predicts the effect of amplitude and frequency of velocity well, and hence it is concluded the effect of low frequency velocity excitation was attributed only to flow effect.

둔각 물체를 이용한 엔진 나셀 화재 소화 특성 (The Characteristic of Extinguishment of Engine Nacelle Fire Using a Bluff Body)

  • 이정란;이의주
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.20-25
    • /
    • 2012
  • The purpose of the study is to assess the extinguishing concentration of inert gases in engine nacelle fire. The experiment was performed with a two dimensional rectangular bluff body stabilized flames, where the fuel was ejected to counter flow and co-flow against an oxidizer stream. Two inert gases, $CO_2$ and $N_2$, were used for extinguishing agent in the oxidizer and methane was used for fuel. The main experimental parameters were the direction of injecting fuel, the kinds of agent and the velocity ratio between air and fuel streams, which controlled the mixing characteristic near bluff body and the strength of recirculation zone in the downstream. The result shows the flame structure and the mode were strongly dependent with fuel/air ratio and the fuel jet direction. For both flow configurations, the extinguishing concentration of $CO_2$ was smaller than the $N_2$ because of the large heat capacity of $CO_2$. However, the concentration of inert gasesat blowout was much smaller than those in the cup burner and coflow jet diffusion flames, which implies that the extinction mechanism of bluff body stabilized flames was mainly due to the aerodynamic aspect. Compared to co-flow fuel injection, the extinguishing concentration of inert gases under counter flow configuration was lower. The effect of direction might result from the mixing characteristic and strength of recirculation zonearound a bluff body. More details should be investigated for the characteristic of recirculation zone in the wake of bluff body using the LES(Large Eddy Simulation).

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • 제9권4호
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

미분무수 첨가제의 소화효과 비교 (Comparison of Fire Extinguishing Effects for Water Mist Additives)

  • 김승일;신창섭
    • 한국안전학회지
    • /
    • 제28권6호
    • /
    • pp.23-28
    • /
    • 2013
  • In order to improve extinguishing performance of water mist, many studies of additives have been conducted. In this study, viscosity agent which has the ability to improve extinguishing performance by adhering to the surface on fire was used and fluorine-free surfactant was also added to water to enhance water's wetting ability. This study aimed to verify optimal concentration of extinguishing of additives according to fire source and extinguishing performance by comparison with pure water. In case of wood crib fire, the results show that flame suppression and extinguishing time of sodium alginate 0.4 wt.% are 3.4 times and 2.2 times shorter than those of pure water in 0.2 MPa respectively. It seems that large amount of water adhere to surface on fire, thus cooling effect on surface was enhanced. Also water consumption of sodium alginate 0.4wt.% is up to 65% lower than that of pure water. In case of heptane fire, extinguishing time of cocobetaine 0.1 wt.% is 9.7 times shorter than that of pure water in 0.2 MPa. It is thought that because cocobetaine can block oxygen and suppress oil mist by making emulsion film on fire surface due to a low surface tension. On the other hand, water consumption of cocobetaine 0.1 wt.% is 92% lower than that of pure water.

증점제를 함유한 미분무수의 목재화재 소화효과 (Efficiency of Water Mist Suppression System Containing Viscosity Agent to Extinguish Wood Cribs Fire)

  • 김민형;신창섭
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.78-84
    • /
    • 2014
  • Viscosity agents were added to water to improve extinguishing performance of low pressure water mist suppression system on wood cribs fire, and a small scale wood cribs fire experiment was conducted to measure the extinguishing performance. CMC and agar were used for viscosity agent and as the amount of viscosity agent enlarges, it showed the increase of the viscosity of aqueous solution and the decrease of the fluidity. On wood cribs fire experiment, the extinguishing efficiency was improved with supplemental viscosity agent as it enhanced the adhesive time of aqueous solution on the wood, and therefore expanded the contact time of fire surface. The surface tension of aqueous solution was decreased with the addition of agar which to be assumed as an increase factor of extinguishing efficiency. By the extinguishing experimental result, the most effective extinguishing agent was CMC 0.6 wt.%, with the flame suppression time and the extinguishing time were reduced by 70s and 93s respectively at this concentration.