• Title/Summary/Keyword: extinguishing agents

Search Result 55, Processing Time 0.019 seconds

Flame Extinguishing Concentrations of Mixed Gaseous Agents (가스계 혼합소화약제의 불꽃소화농도)

  • 김재덕;임종성;이윤우;이윤용
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.34-40
    • /
    • 2001
  • Fire extinguishing efficiency of mixed gaseous agents were investigated by the cup-burner test and predicting by the model of flame extinguishing concentration. The binary mixed agents that tested were carbon dioxide/HFC-23, carbon dioxide/HCFC-22, carbon dioxide/HFC-227ea, carbon dioxide/HFC-125, carbon dioxide/FIC-13I1, Hexafluoropropylene/HFC-23 and ternary mixed agents were carbon dioxide/HFC-23/HFC-l34a, carbon dioxide/HFC-23/HFC-227ea, carbon dioxide/HFC-23/HFC-125. A model which contains the flame extinguishing concentration and composition of pure components predicted the flame extinguishing concentration of mixture well. This model was superior when each component of the mixture exhibit physical fire extinguishing performance.

  • PDF

Flame Extinguishing Characteristics of Clean Gaseous Agents and Effects of Additives (가스계 청정소화약제의 소화특성과 첨가제에 따른 영향)

  • Shin, Chang-Sub;Kim, Sung-Min
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.95-99
    • /
    • 2008
  • Halon was known as a cause of the ozone layer destruction. In 1987, it was designated as one of the ozone-layer-destroying materials in the Montreal Protocol. Therefore substitutes of Halon agent has been developed including inert gas extinguish system, which is one of the most widely used fire extinguishing system. This study intended to increase the efficiency of inert gas extinguishing agent by using inert gas additives. As IG-541 shows high extinguishing power, the experiment was performed to measure the effects of gaseous additives to it. Cup-burner fire extinguishing apparatus was used with n-Heptane fuel. Among many of pure inert gaseous agents, Helium showed the most excellent extinguishing power. When Helium was added to IG-541, fire extinguishing power was increased and the concentration of oxygen in chimney also risen. By adding Helium to IG-541, the effectiveness of inert gas fire extinguishing system is able to be increased.

An Experimental Study on Improvement of Fire Extinguishing Performance of Basic Sprinkler System (간이스프링클러 설비의 소화성능 향상에 관한 실험적 연구)

  • Hur, Min Noung;Shin, Changsub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.46-51
    • /
    • 2018
  • A basic sprinkler system is a fire extinguishing system that can be easily installed in a fire-vulnerable place such as a publicly used establishments. However, the publicly used establishments are not only complicated in structure, but also have a large amount of flammable interior materials, and the users are not normally in a normal state, which is a very dangerous fire-fighting object. Therefore, due to the low fire extinguishing performance of the basic sprinkler system installed in the publicly used establishments, the fire suppression control can not be performed quickly in case of fire, which may increase the life and property damage. In this study, the cases of quantitative changes of extinguishing water used in basic sprinkler system and the cases of addition of additives such as wetting agents, reinforced agents to improve extinguishing performance were compared. Experimental results showed that the extinguishing performance was improved as the quantity of extinguishing water increase and the reinforced agents showed similar performance to that of 60% increase in the amount of extinguishing water. The cooling time to $200^{\circ}C$ and oxygen concentration were improved up to 14.3% and 34.5%, respectively. In the case of using the wetting agent, the cooling time to $200^{\circ}C$ and oxygen concentration did not show any significant improvement, but showed the effect of preventing deep seated fire. In order to prevent loss of life and property, it is necessary to improve the performance of the basic sprinkler system by increasing amount of extinguishing water or using additives like reinforced agents.

Flame Extinguishing Concentrations and Flue Gas Compositions of n-Heptane by Mixed Inert Gas Agents (불활성 가스계 혼합소화약제의 n-Heptane 불꽃소화농도 및 배가스 조성)

  • 김재덕;김영래;홍승태;이성철
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.77-83
    • /
    • 2002
  • We measured flame extinguishing concentration and flue gas composition in the n-heptane fuel cup-burner system using inert gas agents such as nitrogen, argon, carbon dioxide and their mixtures. The flame extinguishing concentration of binary gaseous mixture was well predicted by model which contains the flame extinguishing concentration and composition of pure components. The higher average specific gravity of the mixed inert gas agents, the more excellent flame extinguishing performance. And the structure of enclosed space also affects the fire extinguishing. The composition of carbon dioxide in the flue gas was decreased with increasing extinguishing agent used. Nitrogen monoxide production is not related with increasing nitrogen, but increased at rapid mass flow rate of air in the cup-burner.

Risk Assessment of exposure to the extinguishing agents using CHARM (CHARM을 통한 소화약제 위험성 평가에 관한 연구)

  • Cho, Jung Rae;Jung, Tae Hwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.2
    • /
    • pp.35-41
    • /
    • 2017
  • Recently chemical intoxication related with the use of chemical extinguishing agents occurs frequently. With the industrialization, high-rising of building and increase of fire risk, we use the various extinguishing agents and the safe use become important. In this study I carried out the risk assessment of representative chemical extinguishing agents (HCFC-123, HFC-125) using the CHARM and got the meaningful qualitative outcome. This study is significant in that the risk assessment of chemicals was conducted using CHARM, chemical risk assessment tool. It is expected that the results will be utilized as the basic data for the national chemical safety management.

Extinguishing Characteristics of Zeolite adsorbed Dry Chemical Powder (분말 소화약제가 흡착된 제올라이트의 소화 특성)

  • Shin, Changsub;Park, Hojun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.59-63
    • /
    • 2012
  • The use of dry chemical powder has been increased as it can be stored for a long period and sustain in stable condition compared to gas or liquid phase extinguishing agents. A new type of dry chemical powder using Zeolite was produced in the research. Chemical powder was adsorbed into Zeolite 13X, a porous material appearing negative catalytic effect, to create extinguishing powder obtaining core shell structure and measured physical properties and run a small scale fire extinguishment. SEM, XRD, TA analysis was also executed, and extinguishing characteristics were measured by fire extinguishing experiment on oil pool fire. The experiment showed that the average particle size of Zeolite 13X was equivalent, indicating about $3{\pm}1{\mu}m$ and thermal analysis result illustrated that Zeolite 13X showed exothermic reaction peaks at $900^{\circ}C$ due to solid-state transformation. Extinguishing characteristics on oil fire of $NaHCO_3$/Zeolite 13X and $NH_4H_2PO_4$/Zeolite were improved, influenced by adsorbed extinguishing powders on Zeolite 13X and Zeolite 13X that contains high phase transition temperature.

Development of Fire Extinguisher Valves for Tracked Vehicle Using Novec1230 (친환경 소화약제 Novec1230을 적용하는 궤도차량용 소화기밸브 개발)

  • Kim, Jong-Ryeol;Ku, Hak-Keun;Oh, Sang-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1539-1546
    • /
    • 2011
  • Halon which is one of the typical fire extinguishing agents for special purposes was banned not only to use but to manufacture because it destroys the earth's ozone layer. There have been many efforts to find or create Halon alternatives and Novec1230 which is one of the eco-friendly fire extinguishing agents is nominated. In this paper 6 kinds of valve structures were suggested to apply Novec1230 to fire extinguishing agents for railroad vehicles as Novec1230 needs different valve specifications from Halon and spray shapes and action time were compared and measured. As the results, the extinguishing times of A type and F type valves are 20% faster than the other 4 types, and 178% faster than MIL-DTL-62547(USA). Therefore, they can be suggested to the eco-friendly extinguishing agents and Novec1230.

Study on the Safety Standard Establishment of Halogen Clean Extinguishing Agents (할로겐화합물청정소화약제 안전기준 설정에 관한 연구)

  • Cho, Jung-Rae;Lee, Jong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.22-33
    • /
    • 2018
  • The amount of halogen clean fire extinguishing agents has been increased by the excellent features of extinguishing, adaptability and no residue. On the other hand in situations without a hazard assessment and safety standard of agents, chemical accidents by the agents occurs frequently. This study was performed to propose the halogen clean agents' regulatory exposure limit and safety standard including the quantitative ventilation system with gas leak monitoring, hazard recognition and optimal personal protection selection through a literature review and experimental research.

Flame- Extinguishing Concentrations of Inert Gases in Jet Diffusion Flames (제트확산화염에서의 불활성기체 소화농도)

  • Ji, Jung-Hoon;Lee, Eui-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.1
    • /
    • pp.21-25
    • /
    • 2009
  • Extinguishing limits of laminar ethylene/oxygen flames in both normal and inverse co-flow jet burner have been determined experimentally and computationally. An inert gas($N_2$, Ar, $CO_2$) was added into the oxidizer to find the critical concentration and the effectiveness of the agents on flame extinction. The experimental results showed that the physical aspect of inert gases was main mechanism for flame blow-out as same as cup burner test, but the flow effect should be considered to determine the extinction concentration. The numerical prediction was performed with modified WSR model and the result was in good agreement with the measurements. The experimental and numerical methods could be used for the assessment of various flame suppression agents such as minimum extinguishing concentration.

Inert and Halogenated compounds Fire Fighting Agent And Fire Fighting System Research (불활성계와 할로카본계 복합 소화약제 및 소화시스템 개발)

  • Choi, Keun-Joo;Ahn, Sang-Soo;Kim, Jong-Won;Jung, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.165-171
    • /
    • 2009
  • A compound agent that mixes inert gas agents and halocarbon agents and a complex fire suppression system using the compound agent have been developed. The ultimate goal of this study is to develop the extinguishing agent which doesn't destroy the ozone layer and has low GWP and to develop the fire suppression system. As a result of the test and research for inert gas agents and halocarbon agents, nitrogen and FK-5-1-12 were selected finally and have been tested and studies for three years. Thus, the optimal extinguishing agent and fire suppression system have been accomplished. The performance of the agent and system was tested according to KFI performance test technical standards for gas fire extinguishing system and the fitness of the agent and system for a fire was certified by Korea Fire Industry Technology Institute (KFI).

  • PDF