• Title/Summary/Keyword: external therapy

Search Result 981, Processing Time 0.029 seconds

Impact of Waist Stabilization Exercise with Blood Flow Restriction on White Area Index of Trunk Muscle Thickness Density

  • Park, jae-Cheol;Kim, Yong-Nam
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.2
    • /
    • pp.136-141
    • /
    • 2016
  • Purpose: In this study experiments were performed during 6 weeks with 40 adults, 20 subjects in the waist stabilization exercise with blood flow restriction group and 20 subjects in the waist stabilization exercise without blood flow restriction group, in order to determine the impact of waist stabilization exercise on White Area Index (WAI) followed by blood flow restriction. Methods: Thickness of external oblique abdominal muscle, internal oblique abdominal muscle, and transversus abdominis muscle, as well as density and WAI of external oblique abdominal muscle were measured, followed by performance of repeated ANOVA. Results: Significant difference in thickness of external oblique abdominal muscle according to periodical difference was observed between groups (p<0.05). Significant difference in thickness of internal oblique abdominal muscle and transversus abdominis muscle according to periodical difference was observed between groups (p<0.05). Significant difference in density and WAI of external oblique abdominal muscle according to periodical difference was observed between groups (p<0.05). Conclusion: In conclusion, significant difference was observed after waist stabilization exercise with blood flow restriction. These results can be used as basic data for future research on waist stabilization exercise and blood flow restriction exercise.

Effects of the Support Surface Condition on Muscle Activity of Trunk Muscles during Weight Shifting Exercise (지지면에 따른 체중 이동 시 체간 근육의 근활성도에 미치는 영향)

  • Jung, Kyoung-Sim;Chung, Yijung
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.5
    • /
    • pp.300-305
    • /
    • 2012
  • Purpose: This study examined the muscle activity of the trunk muscles during weight shifting exercises on a stable and unstable surface. Methods: Ten healthy young subjects (4 males, 6 females) with no medical history of lower-extremity or lumbar spine disease were enrolled in this study. The muscle activity was recorded using surface electromyography (EMG) electrodes from the both sides of the external obliques and erector spinae muscles. Results: The EMG activities of the both rectus abdominalis, both external obliques and erector spinae muscles were significantly higher when the weight shifting exercise was performed on a firm surface than when a balance pad with a balance ball was used. In weight shifting exercises, the EMG activity of the contralateral external obliques and erector spinae muscles was significantly higher than that of the ipsilateral external obliques and erector spinae muscles under all three support surface conditions. Conclusion: Performing weight shifting exercise using an unstable surface is a useful method for facilitating the trunk-muscle strength and trunk stability.

A bibliographic study on the external therapy of Acute Mastitis(乳癰Yu-ong) (유선염(乳腺炎) 의 한방(韓方) 외치법(外治法)에 대한 문헌적고찰(文獻的考察))

  • Chang, Sung-Hwan
    • Korean Journal of Korean Medical Institute of Dermatology and Aesthetics
    • /
    • v.1 no.1
    • /
    • pp.177-197
    • /
    • 2005
  • Acute Mastitis(急性乳腺炎=乳癰) is an acute suppurative disease appearing in the breast. It is mostly caused by galactostasis, the stagnation of liver-qi(肝鬱) and stomach-heat(胃熱). It is mostly found in breast feeding women, mostly in primiparae. It usually appears in the third and the fourth weeks of postpartum. At the beginning in the chest there appear induration, distending pain, galactostasis, inversion to cold with fever followed by the enlargement of the masses, burning red, megalgia, not subduing of chills and fever, the accumulation of it to form pus. In the early phase it is advisable to follow the therapeutic principles of soothing the liver and clearing away heat, promoting lactation and subduing swelling. After the formation of pus it is advisable to cut radially and drain the pus. External Therapy(外治法) generally refers to all the methods to treat various diseases and symptoms with application of drugs and manipulation or together with proper instruments on the body surface except the method of taking medicine orally Acute Mastitis has been regarded as surgery or the method of taking medicine orally But, based on many bibliographies, acute mastitis was treated by external therapy. Thus through the historical bibliographic studies of external therapy about acute mastitis, this study was made to help the expanding of the methods of treating acute mastitis.

  • PDF

A Study on the Effect of Internal and External Control on the Relational Aggression's Perception of the Elderly in Care Facilities (내·외 통제성이 시설거주 노인의 관계적 공격성 인식에 미치는 영향에 관한 연구)

  • Kim, Hee-Jung;Cho, Moo-Sin;Kim, Dong-Hyun
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Objective : This study is to know how the internal and external control of the elderly in care facilities affect the relational aggression's perception. Methods : I analyzed the internal and external control and the relational aggression's perception through a survey of the elderly in care facilities. For data collection, 148 of 165 questionnaires, excluding 17 questionnaires with missing questionnaire and middle-level abandonment, were used for the final analysis. Independent variables were the internal and external control, dependent variables were the relational aggression of negative and bullying behaviors, and controlled variables were general sociological characteristics of the elderly. Results : The results were as follows: First, there was a significant difference internal and external control depending on the length of a care facility. Second, there were significant differences in the recognition of relational aggression depending on the level of education, the period of admission, the presence of spouses, and the level of economy. Third, there was a significant difference in comparison of relational aggression perceptions according to internal and external control. Fourth, internal and external control affected the recognition of relational aggression. Conclusion : According to the demographic characteristics, there was a difference in the internal and external control and relational aggression perception of the elderly living in the facilities, and the internal and external control affected the level of relational aggression perception of the elderly in the facilities.

Factor Structure of a Korean-Language Version of the Patient Satisfaction with Procedural Aspects of Physical Therapy Instrument

  • Lee, Hae-Jung;Adams, Roger;Oh, Tae-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • Purpose: The aim of the study was to survey satisfaction with physical therapy. Methods: After the physical therapy consultation, patients filled in a Korean-language version of the 20-tiem version of the MedRisk Instrument developed for measuring Patient Satisfaction with physical therapy. Items are scored on a five-point Likert scale ranging from strongly disagree to strongly agree. The last two items are general satisfaction and future return to the clinic. Age and gender information was also collected anonymously. Exploratory factor analysis based on principal components analysis with varimax rotation was performed on the first 18 items of the MedRisk Instrument using SPSS v.20. Results: Four factors emerged with eigenvalues greater than 1, and these cumulatively explained 55% of the total variance in item scores. The factors were labelled: Internal, External Positives, External Negatives, and Clinic Presentation. Correlations of the factor scores with the two global items ranged from 0.29 to 0.70 (both p<0.001). Gender differences were only found on the last factor, with male Korean patients rating Clinic Presentation significantly higher than females (p=0.001). Conclusion: Using factor analysis, the proposed factor structure was revealed using the positive and negative components of the external aspects of the physical therapy and by identifying a clinic presentation which contributes to patients' satisfaction. The largest proportion of the variance in Patient Satisfaction was related to clinicians' attention and behaviour. The results of the analysis provide guidelines as to the dimensions of professional physical therapy care and the implications for service delivery and patient experience.

The investigation of shoulder height, center of gravity and plantar pressure by backpack weight and location (가방 휴대방법과 무게에 따른 어깨높이, 중력 중심선과 발바닥 압력 변화 연구)

  • Son, Seon-Ju;Han, Min-Kyu;Lee, Hye-Jin;Seo, Young-Mi;Park, Ha-Na;Lee, Sang-Young;Park, Cheol-Woo;Kwon, Gu-Hyun;Kim, Hyoung-Su
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.3
    • /
    • pp.71-78
    • /
    • 2011
  • Purpose : The purpose of this study found change that caused by various form and weight of bag. So we investigated how these things change the shoulder altitude and space between external acoustic pore and lateral malleolus and also plantar pressure. Method : We measured two different way for this study. One was backpack with 5, 10kg and another one was shoulder pack with same weight. Each trial was 10 seconds in duration with static stance posture. With these experiments, we checked space between plantar pressure, shoulder altitude, external acoustic pore and lateral malleolus with EMED system and GPS. We analyzed these results with PASW(SPSS) statistics 18.0. Result : In conclusion, there were no significantly differences in shoulder altitude by weight of pack, but average of plantar pressure and space between external acoustic pore and lateral malleolus was increased.

  • PDF

A study on the effect of UV exposure on the skin due to external activities (외부활동에 따른 자외선 노출이 피부에 미치는 영향 연구 -피부물리치료를 위한 기초 연구-)

  • Lee, Kwang jae;Choi, Young in
    • Journal of Korean Physical Therapy Science
    • /
    • v.21 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • Background : The purpose of this study is to verify the type of influence on the skin color according to the photoaging symptoms depending on the degree of external activities among the factors that influence the skin due to UV exposure and to obtain the basic study data on the physical therapy of the skin. Methods : In this study, in order to investigate the type of influence on the skin color according to the photoaging symptoms when the body is exposed to the UV rays having various effects on our body, a study was conducted using questionnaires and skin color measurement tool targeting 20 male college soccer students with many external activities and the senior high school students who has relatively less external activities due to the preparation for college entrance. The skin color was measured and the results were compared. Result : In the test group having relatively higher external activities, while they had less use of the sunscreen, they had more degree of UV exposure, and for the recognition of ultraviolet hazard, more were aware that it was harmful. In addition, in the skin color measurement test conducted targeting the son and the father in order to investigate the association between the skin color and the genetic factors, the experimental group showed a significant difference(p<.05) but the control group did not show any significant difference(p>.05). Conclusion : Based on such study results, the UV exposure time and the use of sunscreen are thought to be an important factor in the skin care.

  • PDF

The Effectiveness of the External Support on the Strength and Muscle Activity of Hip Abductor in Subject Without Core Stability (심부 안정성이 부족한 대상자에게 외부적 지지가 엉덩관절 벌림근의 근력과 근활성도에 미치는 영향)

  • Jeon, In-Cheol
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.64-69
    • /
    • 2022
  • Background: Gluteus medius muscle is important for the stability of hip joint. The sufficient core stability can be contributed to the performance of gluteus medius muscle in standing position. In addition, the external support may affect core stability in standing position. Objects: The purpose of this study was to investigated the effectiveness of the external support on the strength and muscle activity of hip abductor muscle during hip abduction in standing position in subjects without core stability. Methods: Fifteen subjects participated in this study. The subjects were evaluated by using the double-leg lowering with bent knees to measure the core stability. The strength and muscle activity of hip abductors was measured in standing position with the condition with and without external support using the tensiometer sensor and the surface electromyography. The paired t-test was used to investigate the difference between hip abductor strength and activity according to external support. The level of statistical significance was set at α = 0.05. Results: The hip abductor strength and muscle activity of gluteus medius muscle with external support were significantly greater than those without external support during hip abduction in standing position (p < 0.05). Conclusion: During hip abduction in standing position, the external support may be contributed to the improvement of the hip abductor strength and muscle activity of gluteus medius especially in the subjects without core stability.

Influence of Longitudinal Arch of Foot on the Strength and Muscle Activity of the Abductor Hallucis in Subjects with and without Navicular Drop Sign

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.4
    • /
    • pp.222-227
    • /
    • 2019
  • Purpose: This study examined the influence of longitudinal arch on the strength and muscle activity of the abductor hallucis in the standing position in subjects with and without navicular drop signs. Methods: A sample of 34 subjects with and without navicular drop signs between 22 and 28 years of age were enrolled in this study. The strength and muscle activity of the abductor hallucis was measured using a tensiometer. The Smart KEMA System and electromyography device was used on the subjects with and without navicular drop signs. Two groups were classified using the navicular drop test to identify the longitudinal arch of the foot. The strength of the abductor hallucis was evaluated in standing, both with and without an external arch support condition. The two-way mixed ANOVA was used. The level of statistical significance was set to ${\alpha}=0.05$. Results: The strength and muscle activity of the abductor hallucis in standing was significantly higher with external arch support than that without the external arch support in the group with navicular drop signs. There was no significant difference in the abductor hallucis strength and muscle activity with and without external arch support in the subjects without navicular drop signs. Conclusions: The strength and muscle activity of the abductor hallucis in standing can be influenced by the external arch support in the group with navicular drop signs. The strength measurement of the abductor hallucis in standing should be separately performed in conditions with and without longitudinal arch of foot.

Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.