• Title/Summary/Keyword: external magnetic field

Search Result 448, Processing Time 0.032 seconds

Experimental nonlinear vibrations of an MRE sandwich plate

  • Zhang, Jiawei;Yildirim, Tanju;Alici, Gursel;Zhang, Shiwu;Li, Weihua
    • Smart Structures and Systems
    • /
    • v.22 no.1
    • /
    • pp.71-79
    • /
    • 2018
  • The nonlinear vibration analysis of a magneto-rheological elastomer (MRE) sandwich plate is conducted experimentally. Experiments have been performed in order to construct the frequency-response curves in the vicinity of the fundamental natural frequency of an MRE sandwich plate (plate A) in either the absence or presence of a localised external magnetic field at 3 different geometrical locations, for both small and medium magnetic fields. Furthermore, experiments have also been conducted on a pure aluminium plate (plate B) with an equal thickness to the MRE sandwich plate (plate A) in order to examine the influence of the MRE layer on the nonlinear dynamics of the system. An electrodynamic shaker was used to directly force each system and the displacement at the centre of the plate was measured. Meanwhile, permanent magnets were used to apply a localised magnetic field for the experiments where the MRE sandwich plate was subject to an external magnetic field. It was observed all the MRE systems displayed strong hardening-type nonlinear behaviour, however, with increasing magnetic field this behaviour transitioned to a weak hardening-type nonlinearity.

Magnetic-field-tuned Insulator to Conductor Transition in Magnetorheological Suspension

  • Yang, Xiongbo;Jiang, Yuhuan;Huang, Yuehua;Xu, Ruizhen;Piao, Hongguang;Jia, Gaomeng;Tan, Xinyu
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.345-348
    • /
    • 2014
  • Magnetorheological suspensions (MRSs) are smart materials that have the potential to revolutionize several industrial sectors because of their special rheological behaviors. In this paper, MRS, based on carbonyl iron (CI) microparticles that were dispersed in silicone oil with oleic acid, were prepared. We showed that the electroconductibility of MRS was significantly influenced by the intensity of the external magnetic field that was applied. The resistance value can vary from infinite to below $300{\Omega}$ after applying an external magnetic field. The results indicated that this MRS had the property of magnetic-field-tuned insulator to conductor transition. This system has potential applications in controllable MRS electrical devices.

High Frequency Impedance of Meander Pattern Fabricated by Co-base Amorphous Ribbon (Co계 아몰퍼스리본을 이용하여 제작한 마안더패턴의 고주파 임피던스특성)

  • Shin, Kwang-Ho;Park, Kyung-Il;Geon, Sa-Gong;Song, Jae-Yeon;Kim, Young-Hak
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.4
    • /
    • pp.160-164
    • /
    • 2003
  • The external magnetic field dependency of the impedance, resistance, and inductance of the meander pattern fabricated by using Co-base amorphous ribbon has been investigated in the frequency range of 300 ㎑∼1 ㎓. The amorphous ribbon was patterned to the meander pattern through conventional photolithography and wet etching process. The extremely high sensitivity in impedance changing ratio by external magnetic field was observed. This is due to the transverse magnetic anisotropy the pattern which was induced by magnetic field annealing. The impedance had peak value at the external field of -13 Oe and the impedance changing ratio 100 ${\times}$ (Z$\_$13/-Z$\_$0/)/Z$\_$0/) was about 210% at the frequency of 50 MHz.

A Study on the Current Detector with Non Contact Type (비접촉식 전류 검출 장치에 관한 연구)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.5
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.

GMI Magnetic Field Sensor Based on a Time-coded Principle

  • Cao, Xuan-Huu;Son, De-Rac
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.221-224
    • /
    • 2010
  • A laboratory sensor model was designed, constructed, and tested based on a newly proposed working principle of magnetic field detection. The principle of sensing employed a time-coded method in correlation with exploiting the advantageous features of the GMI effect. The sensor demonstrated a sensitivity of $10\;{\mu}s/{\mu}T$ in the field range of ${\pm}100\;{\mu}T$. The sensing element in the form of an amorphous thin wire, $100\;{\mu}m$ in diameter ${\times}50\;mm$ long, was fit into a small field modulation coil of 60 mm length. At a magnetic field modulation in the range of hundreds of Hz, the change in time interval of two adjacent GMI voltage peaks was linearly related to the external magnetic field to be measured. This mechanism improved the sensor linearity of the GMI sensor to better than 0.2% in the measuring range of ${\pm}100\;{\mu}T$.

Time-Coded GMI Magnetic Field Sensor

  • Cao, Xuan-Huu;Son, Derac
    • Journal of Magnetics
    • /
    • v.14 no.3
    • /
    • pp.129-131
    • /
    • 2009
  • A time-coded giant magnetoimpedance (GMI) magnetic field sensor was investigated and designed. The successfully constructed and tested laboratory model demonstrated a sensitivity of 5 ${\mu}s/{\mu}T$ in the field range of $\pm200{\mu}T$. The sensing element in the form of an amorphous thin wire, 100 mm in diameter $\times50$ mm long, was fit into a small field modulation coil of 60 mm length. At a magnetic field modulation in the range of hundreds of Hz, the change in time interval of two adjacent GMI voltage peaks was linearly related to the external magnetic field to be measured. This mechanism improved the sensor linearity to better than 0.3% in the measuring range of $\pm200{\mu}T$.

External Magnetic Field of Journal Bearing with Twined Solenoid

  • Zhang, Yanjuan;Wang, Jianmei;Li, Decai
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.291-298
    • /
    • 2017
  • In this paper, the distribution of internal magnetic induction intensity of oil-film bearing twined solenoids was proposed. The magnetic field was generated by solenoids and magnetized bearing. The magnetized bearing was simplified as solenoid model. The mathematical model of magnetic induction intensity at any point of finite solenoid was deduced. Through experiment method, the distribution of the internal magnetic induction intensity of oil-film bearing and the magnetizing current formula of bearing was obtained. Further, the magnetic induction intensity distribution of magnetization bearing was solved successfully. The results showed that the magnetic induction was a second-degree parabola with open upwards along the axial plane and the distribution of magnetic induction intensity was opposite to the rule of magnetic induction intensity generated by solenoids. In addition, the magnetic flux density increased linearly with the increase of current.

EFFECT OF MAGNETIC FIELD ON LONGITUDINAL FLUID VELOCITY OF INCOMPRESSIBLE DUSTY FLUID

  • N. JAGANNADHAM;B.K. RATH;D.K. DASH
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.2
    • /
    • pp.401-411
    • /
    • 2023
  • The effects of longitudinal velocity dusty fluid flow in a weak magnetic field are investigated in this paper. An external uniform magnetic field parallel to the flow of dusty fluid influences the flow of dusty fluid. Besides that, the problem under investigation is completely defined in terms of identifying parameters such as longitudinal velocity (u), Hartmann number (M), dust particle interactions β, stock resistance γ, Reynolds number (Re) and magnetic Reynolds number (Rm). While using suitable transformations of resemblance, The governing partial differential equations are transformed into a system of ordinary differential equations. The Hankel Transformation is used to solve these equations numerically. The effects of representing parameters on the fluid phase and particle phase velocity flow are investigated in this analysis. The magnitude of the fluid particle is reduced significantly. The result indicates the magnitude of the particle reduced significantly. Although some of our numerical solutions agree with some of the available results in the literature review, other results differs because of the effect of the introduced magnetic field.

The Magnetization Losses Characteristics of Multi-stacked and Variable Angle of External Magnet Field in YBCO CC and BSCCO tape (YBCO Coated Conducor와 BSCCO tape의 적층 및 외부자장의 각도에 따른 자화손실 특성)

  • Lim, Hyoung-Woo;Lee, Hee-Joon;Cha, Guee-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.34-38
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper, magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various angle of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. The magnetization losses of YBCO CC are larger than those of BSCCO tapes when the external magnetic field is increased.

Comparison Magnetization Losses of the multi-stacked YBCO Coated conductor and the BSCCO tapes (YBCO CC와 BSCCO Tape의 적층에 따른 자화손실 특성비교)

  • Lim Hyoungwoo;Lee Heejoon;Cha Gueesoo;Lee Ji-Kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.13-16
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various stacked of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. As the external magnetic field decreased, the ratio of decrement has risen because the full penetration magnetic field(Bp) of the multi-stacked tape is larger than that of the single tape.