• Title/Summary/Keyword: external heat method

Search Result 231, Processing Time 0.027 seconds

The Thought of Etiology and Pathogenesis of Convulsion Disease (경병(痙病)의 병인병기(病因病機)에 대(對)한 문헌적(文獻的) 고찰(考察))

  • Ryu, Ho Ryong;Hwang, Chi Weon
    • Journal of Haehwa Medicine
    • /
    • v.8 no.1
    • /
    • pp.371-378
    • /
    • 1999
  • Through the thought of etiology and pathogenesis of convulsion disease in past document, we concluded as follow. 1. Convusion disease brings about some symptoms such as myotonia, neck stiffness, myospasm of four limbs, and in the ancient times it was called in Gye-Jong, Chu-Pung(抽風), Chi. 2. Etiologies of convulsion disease are external invasion of Pung-Han-Seub(風寒濕) and Ybul-Sa(熱邪), mistreatment, great loss of blood, deficiency of Gi-Hyul(氣血), stagnation of phlegm and blood. 3. There are four pathologic cases which arise convulsion disease. They are muscular denutrition from meridian stagnation by external invasion, muscular denutrition of heat injury, stagnation of phlegm and thrombus in meridian, muscular denutrition with deficiency of Gi-Hyul(氣血). 4. The treatment methods of convulsion disease are divided into three. If caused by external invasion, the methods are San-Han-Hae-Gi(散寒解肌), Hwa-Yung-Jo-Joong(和營調中). If caused by deficiency of Gi-Hyul(氣血), the method is Bo-Gi-Ik-Hyul(補氣益血). If caused by stagnation of phlegm and blood, the methods are Hwal-Hyul-So-Eo(活血消瘀), Do-Dam-Gun-Bi(導痰健脾).

  • PDF

A Study on the Gagamjeong-gisan in the Onbyeongjobyeon - In Comparison with the Gwakhyangjeong-gisan - (『온병조변(溫病條辨)』 에 나타난 가감정기산(加減正氣散)에 대한 고찰 - 곽향정기산(藿香正氣散)과의 비교를 중심으로 -)

  • Kim Sanghyun;Kim Jong-hyun
    • Journal of Korean Medical classics
    • /
    • v.36 no.2
    • /
    • pp.77-96
    • /
    • 2023
  • Objectives : The purpose and application method of the five kinds of Gagamjeong-gisan in the Onbyeongjobyeon were analyzed and their significance was examined. Methods : First, contents within medical texts on the Gwakhyangjeong-gisan, the original formula for the Gagamjeong-gisan were analyzed. Next, application, symptoms and pathogenic mechanism, treatment principle, composition of the Gagamjeong-gisan as written in the Onbyeongjobyeon were analyzed. Characteristics of each formula as deduced from this process were compared and examined. Results : The Gwakhyangjeong-gisan covers both external contraction and internal damage, applied regardless of external or internal symptoms. It restores the Yang qi of the Spleen and Stomach, balancing the Zheng qi to respond to the external qi. The Gagamjeong-gisan takes after the Gwakhyangjeong-gisan, reflecting such properties. However, the latter differs in that it excludes ingredients unfit for treating dampness-warmth, and uses different application methods according to the level of discharge of dampness pathogen. Conclusions : The Gagamjeong-gisan is modified from the Gwakhyangjeong-gisan, which is applied to cold damage and internal damage to better treat warm disease. It can be said to have acted as a bridge for warm disease scholars in composing formulas that deal with dampness-heat disease.

An Assessment on the Ultimate Strength of Welding Joint by the Effect of External Force (外力의 效果를 고려한 熔接部의 最終强度에 대한 評價)

  • Bang, Han-Seo;Cha, Yong-Hun;O, U-Seok
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.20-29
    • /
    • 1995
  • When structures are constructed by welding, structural elements are always accompained by welding residual stress and deformation. Therefore, when the rigidity and strength of the welded structures is considered, it is very important to have sufficient information about the effect of initial deflection and welding residual stress on them. In this paper, the square plates with welding residual stress under compression are dealt with; First, heat conduction and thermal elastic-plastic problems are analyzed by finite element method using 4-node isoparametric elements for assessment on the ultimate strength of welding joint. Later, the ultimate strength of welding joint is assessed by examining the effect of changed type of loading. The specimens are 500{\times}$500mm(a/b=1) and 750{\times}$500mm(a/b=1.5) rectangular plates of whichthicknesses is 9.0mm and simply supported plates getting axiul load in each direction.

  • PDF

The Liturature Study of Purpura (In comparison with Purpura of Adult) (소아자반에 관한 동서의학적 문헌적 고찰)

  • Kim, Yun Hee;Han, Jae Kyung;Kim, Yun Hee
    • Journal of Haehwa Medicine
    • /
    • v.13 no.1
    • /
    • pp.183-195
    • /
    • 2004
  • Objective: The aim of this study was to investigate the concept of purpura in the western and oriental medicine. Method: We surveyed the western and oriental medical books from to recent published books. Result and Conclusion: The cause of purpura is devided into two branchs. One is sthenia syndrome includes stomach-heat, blood-heat and abnormal weather in four seasons. The other is asthenia syndrome includes deficiency of stomache energy, spleen asthenia and deficiency of Yin. In children, the cause of purpura is improper diet, inherent defect and the above things. The treatment of oriental medicine is classified into herbal medication, acupuncture therapy and external treatment

  • PDF

Prediction of Heat and Water Distribution in Concrete due to Changes in Temperature and Humidity (온도와 습도의 변화에 따른 콘크리트 내부의 열, 수분 분포 예측)

  • Park, Dong-Cheon;Lee, Jun-Hae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.31-32
    • /
    • 2020
  • Concrete changes its internal moisture distribution depending on the external environment, and changes in the condition of the material's interior over time affect the performance of the concrete. These effects are closely related to the long-term behavior and durability of concrete, and the degree of deterioration varies from climate to climate in each region. In this study, we use actual climate data from each region with distinct climates. A multi-physical analysis based on the method was conducted to predict the difference and degree of deterioration rate by climate.

  • PDF

A Study for Analysis of Micro Heat Grid Configuration and Deduction of Optimal Size in Hydrogen Cities (수소도시 내 마이크로 히트그리드 구성 방안 및 최적 규모 산정 연구)

  • JONGJUN LEE;SEUL-YE LIM;KYOUNG A SHIN;NAMWOONG KIM;DO HYEONG KIM;CHEOL GYU PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.845-855
    • /
    • 2022
  • In response to climate change, the world is continuing efforts to reduce fossil fuels, expand renewable energy, and improve energy efficiency with the goal of achieving carbon neutrality. In particular, R&D is being made on the value chain covering the entire cycle of hydrogen production, storage, transportation, and utilization in order to shift the energy supply system to focus on hydrogen energy. Hydrogen-based energy sources can produce heat and electricity at the same time, so it is possible to utilize heat energy, which can increase overall efficiency. In this study, calculation of the optimal scale for hydrogen-based cogeneration and the composition of heat sources were reviewed. It refers to a method of the optimal heat source size according to the external heat supply and heat storage to be considered. The results of this study can be used as basic data for establishing a hydrogen-based energy supply model in the future.

Flow Boiling Heat Transfer Characteristics of R22 Alternative Refrigerants in a Horizontal Smooth Tube (R22 대체냉매의 수평원관내 흐름비등 열전달 특성)

  • 한재웅;김신종;정동수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.242-251
    • /
    • 2001
  • Flow boiling heat transfer coefficients (HTCs) of R22, R134a, R407C, and R410A were measured for a horizontal plain tube. The test section was made of a copper tube of 8.8mm inner diameter and 1000mm length respectively. The refrigerant was heated by passing hot water through an annulus surrounding the test section. All tests were performed at a fixed refrigerant saturation temperature of $5^{\circ}C$ with mass fluxes of 100~300 kg/$m^2$,/TEX>s. HTCs were measured by two methods: the direct wall temperature measurement method and the indirect Wilson plot method. Experimental results showed that the Wilson plot method was affected greatly by the external test conditions and yielded inconsistent results. For the mass flux of 100kg/$m^2$,/TEX>s, HTCs were almost constant regardless of the quality for a given refrigerant HTCs of R134a and R407C were similar to those of R22 while those of R410A were 60% higher than those of R22. For the mass fluxes of 200 and 300kg/$m^2$,/TEX>s, HTCs of R407C were almost the same as those of R22, while HTCs of R134a and R410A were 12-13% and 20~23% higher than those of R22 respectively. For pure refrigerant, Shah\`s correlation yielded a good agreement with the measured data both qualitatively and quantitatively.

  • PDF

Synthesis and Evaluation of Variable Temperature-Electrical Resistance Materials Coated on Metallic Bipolar Plates (온도 의존성 가변 저항 발열체로 표면 처리된 금속 분리판 제조 및 평가)

  • Jung, Hye-Mi;Noh, Jung-Hun;Im, Se-Joon;Lee, Jong Hyun;Ahn, Byung Ki;Um, Sukkee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.73.1-73.1
    • /
    • 2010
  • For the successful cold starting of a fuel cell engine, either internal of external heat supply must be made to overcome the formation of ice from water below the freezing point of water. In the present study, switchable vanadium oxide compounds as variable temperature-electrical resistance materials onto the surface of flat metallic bipolar plates have been prepared by a dip-coating technique via an aqueous sol-gel method. Subsequently, the chemical composition and micro-structure of the polycrystalline solid thin films were analyzed by X-ray diffraction, X-ray fluorescence spectroscopy, and field emission scanning electron microscopy. In addition, it was carefully measured electrical resistance hysteresis loop over a temperature range from $-20^{\circ}C$ to $80^{\circ}C$ using the four-point probe method. The experimental results revealed that the thin films was mainly composed of Karelianite $V_2O_3$ which acts as negative temperature coefficient materials. Also, it was found that thermal dissipation rate of the vanadium oxide thin films partially satisfy about 50% saving of the substantial amount of energy required for ice melting at $-20^{\circ}C$. Moreover, electrical resistances of the vanadium-based materials converge on an extremely small value similar to that of pure flat metallic bipolar plates at higher temperature, i.e. $T{\geq}40^{\circ}C$. As a consequence, experimental studies proved that it is possible to apply the variable temperature-electrical resistance material based on vanadium oxides for the cold starting enhancement of a fuel cell vehicle and minimize parasitic power loss and eliminate any necessity for external equipment for heat supply in freezing conditions.

  • PDF

A Design of Temperature Management System for Preventing High Temperature Failures on Mobility Dedicated Storage (모빌리티 전용 저장장치의 고온 고장 방지를 위한 온도 관리 시스템 설계)

  • Hyun-Seob Lee
    • Journal of Internet of Things and Convergence
    • /
    • v.10 no.2
    • /
    • pp.125-130
    • /
    • 2024
  • With the rapid growth of mobility technology, the industrial sector is demanding storage devices that can reliably process data from various equipment and sensors in vehicles. NAND flash memory is being utilized as a storage device in mobility environments because it has the advantages of low power and fast data processing speed as well as strong external shock resistance. However, flash memory is characterized by data corruption due to long-term exposure to high temperatures. Therefore, a dedicated system for temperature management is required in mobility environments where high temperature exposure due to weather or external heat sources such as solar radiation is frequent. This paper designs a dedicated temperature management system for managing storage device temperature in a mobility environment. The designed temperature management system is a hybrid of traditional air cooling and water cooling technologies. The cooling method is designed to operate adaptively according to the temperature of the storage device, and it is designed not to operate when the temperature step is low to improve energy efficiency. Finally, experiments were conducted to analyze the temperature difference between each cooling method and different heat dissipation materials, proving that the temperature management policy is effective in maintaining performance.

The Noise Reduction Effect by the Enclosure of Gas Turbines (가스터빈 차폐막의 소음 저감효과에 관한 연구)

  • Park, Dae Hun;Shin, Yoo In;Park, Sung Gyu;Kim, Kang Il;Song, Chul Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.4
    • /
    • pp.287-292
    • /
    • 2017
  • A gas turbine is the main equipment used in a combined heat and power plant. It generates a high sound pressure noise level. To reduce the noise level, an enclosure is installed around the turbine. The sound insulation performance of the enclosure affects the amount of external noise reduction. In this study, a sound transmission loss analysis is performed using the boundary element method to predict sound insulation performance according to the numbers and shapes of the supporter. Radiated noise analysis is also performed for the main external points of the enclosure using ray-acoustics. The results of these analyses are presented and a design plan is proposed that reduces the sound pressure noise level of the enclosure.