• Title/Summary/Keyword: external heat

Search Result 875, Processing Time 0.029 seconds

Confirmation of Applicability of Heating and Curing Method of Concrete in Winter Using Electric Heating System (전기열풍기를 이용한 동절기 콘크리트 가열양생공법 적용 및 적정성 효과 검증)

  • Kim, Se-Jong;Park, Jong-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.131-132
    • /
    • 2022
  • Looking at recent construction cases at winter construction sites, there is a risk that heat sources such as kerosene fans and fossil fuels (brown coal, molded carbon) used in concrete will cure rapidly, so in situations where further curing is impossible after formwork removal, the outer wall and the entire slab are exposed to rapid external deterioration, resulting in delays in concrete strength expression and until collapse accidents. In this study, we applied kerosene fans and tropical circulating electric heat fans mainly used as curing heat sources at construction sites, comparative analysis. also verified the performance of structures during concrete curing due to thermal convention / circulation performance, concrete demand strength expression, and implementation of electric heat fans by heavy disaster methods.

  • PDF

Microstructures and Tensile Properties by Multi-step Isothermal Heat Treatment in Conventional TRIP Steel (상용 TRIP강의 다단 항온 변태 열처리에 따른 미세조직 및 인장 특성)

  • Kim, Kyeong-Won;Lee, Chang-Hoon;Kang, Jun-Yun;Lee, Tae-Ho;Cho, Kyung-Mox
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.29 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • In recent years, TRIP steels which are composed of ferrite, bainite, and retained austenite have drawn much attention for automotive sheets due to excellent combination of strength and ductility. The effect of two-step isothermal heat treatment of bainitic transformation on microstructures, especially retained austenites and tensile properties in the conventional TRIP steel was investigated. A two-step isothermal heat treatment, in which 50% bainitic transformation occurred at high temperature, followed by bainitic transformation at low temperature, improves tensile properties, resulting from enhanced mechanical stability of retained austenite against external plastic deformation due to refinement of retained austenites, compared to single-step isothermal heat treatment.

The Performance Analysis of the Fin-Tube Heat Exchanger Using CFC Alternative Refrigerant (CFC 대체냉매를 사용한 핀-관 열교환기의 성능해석)

  • 박희용;박경우;차재병
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2358-2372
    • /
    • 1993
  • In this study, the computer modeling for prediction of the performance of fin-tube heat exchanger using alternative refrigerant, HFC-134a was developed and the computer program for calculating the various properties of HFC-134a and the existing refrigerant CFC-12 and HCFC-22 was made. The heat exchanger modeling is based on a tube-by-tube approach, which is capable of analysis for the complex coil array. Performance of each tube is analyzed separately by considering the cross-flow heat transfer with external airstream and the appropriate heat and mass transfer relationships. A performance comparison according to the different refrigerants is provided using this developed model. As the result of this study, total heat transfer rate of evaporator and condenser using HFC-134a were found higher than that of using CFC-12 for the same operating conditions. When the mass flow rate of HFC-134a was less than CFC-12 about 18. 16%, the cooling capacities of evaporator were found to be the same.

Overall Heat Transfer Coefficients and Thermal Performance Evaluation through Heat Flux Measurement at Nakseonjae in Changdeokgung (창덕궁 낙선재 외피 열류량 실측을 통한 열관류율 산정 및 열 성능 해석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Han, Wook;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.190-195
    • /
    • 2008
  • The objective of this research is to determine overall heat transfer coefficients (K-value) of exterior wall, floor, and roof of Nakseonjae, a Korean traditional residence via field measurement of transient heat flow and temperature difference across each envelope component. Heat flow sensors and T-type thermocouple were attached on the internal and the external surface of each building component, and real-time measurement data were collected for the three consecutive summer days. The K-values determined in this research showed good agreement with other results from open literature. Peak and annual thermal loads of the traditional residence estimated by a commercial energy simulation program were compared with those for a current apartment house. The traditional house showed lower annual cooling load than that of the current building. It may caused by the fact that the traditional building has less air-tight envelopes and no fenestration passing direct solar radiation into the space.

  • PDF

Capacity Modulation of a Heat Pump System by Changing the Composition of Refrigerant Mixtures (혼합냉매의 성분비 조절을 통한 열펌프의 용량조절)

  • 김민성;김민수;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.258-266
    • /
    • 2000
  • Experimental investigation and cycle simulation of a capacity modulation of a heat pump system using a hydrofluorocarbon (HFC) refrigerant mixture, R32/134a as an alternative to R22, have been done. In the cycle simulation, the refrigeration system was operated by assigning the temperatures of the external heat transfer fluids with the heat exchangers generalized by an average effective temperature difference. Heating capacity, cooling capacity, and coefficient of performance (COP) of the system were investigated at several operating conditions. Experimental apparatus which had a refrigeration part and a composition changing part was built, and the performance of the heat pump system filled with R32/134a mixture was investigated. A gas-liquid separator was used in the experiment to change the composition by collecting the vapor and the liquid Phase separately, The mass fraction of the charged refrigerant in the heat pump system was 40/60 and 70/30 by weight percentage. The composition of the refrigerant with initial composition of 40/60 varied from 29/71 to 41/59 in the refrigeration cycle. For the refrigerant with initial composition of 70/30, the composition varied from 65/35 to 75/25.

  • PDF

Numerical Analysis on the Characteristics of Thermal Flow in an Automobile Radiator (자동차용 라디에이터 열유동 특성에 관한 수치해석)

  • Kang, Chang Won;Kim, Tae Joon;Lee, Chi Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.6
    • /
    • pp.55-61
    • /
    • 2019
  • The purpose of this study was to numerically analyze the heat flow characteristics of an automotive radiator. Heat flow analyses were conducted on the cooling water and outdoor air of the radiator, as well as the temperature distribution of the cooling water after heat transfer. The results of the study revealed that neither heat transfer nor radiator volume was affected by the position of the inlet of cooling water. However, temperature distribution was affected by the position of both the inlet and outlet. In case of heat transfer, three models underwent about 158 kW of heat transfer. The difference in cooling water temperature was about $10^{\circ}C$. In case of pressure drop, the core external air side was reduced to about 1,375 Pa, and the internal cooling water side about 14,570 Pa.

A study on the Theory of 'Ja-Yeol(刺熱)' in 32nd Chapter of 'So Moon(素問) Yellow Emperior's Nei-Ching(黃帝內經)' (황제내경(黃帝內經) 소문(素問) 자열론(刺熱論)에 대한 연구(硏究))

  • Kwon, Kun-Hyuck;Hong, Won-Sik
    • Journal of Korean Medical classics
    • /
    • v.3
    • /
    • pp.151-217
    • /
    • 1989
  • In this thesis, I intend to study the translational and clinical interpretation through the theory of Ja-Yeol, and reached the following conclusions. 1. Liver-Heat-Disease due to absess of the function of expelling and lifting off, that Liver-Yang cannot lift up to upper-warmer, and stagnate liver. I think the symptoms of yellowish urine, abdominal pain, somnolence, fever belong to the syndrome of 'Gi-Bun(氣分)', and the symptoms of ravings with surprising, distending pain of hypochondrium, restless involuntary movement of the limbs, unable to lie flat belong to the syndrome of 'Hyeol-Bun(血分)'. 2. Heart-Heat-Disease due that 'Eum-Gi(陰氣)' in heart cannot lay down and reach to stagnate at heart, inner part. I think the symptoms of unjoy, acute cardiac pain, fidgetiness, well-nausea, headeche, reddish face, anhidrosis, etc. reveal with Heart-Heat-Disease. 3. Spleen-Beat-Disease due that 'Eum-Gi' in spleen cannot lay down and Yin of spleen changs heat. I think the symptoms of heaviness of head, cheek pain, fidgetiness, cyanosis, well-nausea, fever, not to let flex and reflex with back pain, diarrhea with abdominal pain, left and right cheek pain reveal with Spleen-Heat-Disease. I think symptoms of fever, diarrhea with abdominal pain belong to the syndrome of Yin-exhausion. 4. Lung-Heat-Disease due to that 'Eum-Gi' in lung cannot lay down. When 'Wi-Gi(衛氣)' stagnates at external part, I think, the symptoms of intolerance to wind and cold, yellowish fur, fever reveal. When Wi-Gi stagnates at lung, inner part, I think, the symptoms of dispnea with cough, pain on chest and back, unable to breath deeply, hydrosis and chilling reveal. 5. Kidney-Heat-Disease, in that the symptoms of back pain, leg aching, extreme thirst and frequently drink, fever, pain and stiffness of nape, cooling and aching leg, heat on plantar pedis, not trying to speak reveal is regarded external heat disease of 'Tai-Yang-Gyeong's(太陽經)' disease that asthenic fever open 'Tai-Yang-Gyeong' and lift by not enough of 'Yang-Gi(陽氣)' lifeing up from Kidney space, the water space of five elements.

  • PDF

Mathematical Modeling of the Effect of External Radiative Heating on Heat and Mass Transfer Between A Semi-transparent Diesel Fuel Droplet and Quiescent Air

  • Woo In-Sung;Choi Sung-Eul;Stamatov Venelin
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2004
  • The system considered in this model consists of a single, semi- transparent, diesel fuel droplet, which is immobile in the heating area and surrounded by a quiescent air. A uniform external radiation field surrounds the droplet. Results from mathematical simulation suggest that because of the higher surface temperature, the external radiative heating of the droplet can promote an earlier ignition of the fuel vapour/air mixture. The radiative heating of the droplet increases the mass transfer from the droplet to the surrounding gas-phase, thus, decreasing the heterogeneity of the fuel droplet/air system.

A Literatual Study on the external treatment of eye diseases (眼病의 外治法에 대한 文獻的 考察)

  • Seo, Hyung-Sik;Lee, Yong-Ku;Rho, Sek-Seon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.10 no.1
    • /
    • pp.185-208
    • /
    • 1997
  • A Literatual Study on the external treatment of eye diseases, the result were as follows. 1. The external treatment of eye diseases used eyedrops(點,滴), steam bath(熏), washing(洗), plaster(敷). 2. Eyedrops used filterated decoction. 3. Eye diseases used Bomeolum(永片), Coptidis Rhiwma(黃連), Angelicae gigantis Radix(當歸) with clearing away heat and toxic materials, clearing away swelling, pain, ithing and convulsion, clearing away nebula 4. Eye diseases used B-1(晴明), B-2(찬竹), Tae-Yang(太陽), S-1(承泣), G-1(瞳子료), S-2(四白), TE-23(絲竹空), Eo-Yo(魚腰), G-14(陽白), Gu-Hu(球後), G-20(風池), B-18(肝兪), LI-4(合谷), Liv-3(太衡, B-23(腎兪), G-37(光明), Liv-2(行間), GV-23(上星), and S-36(足三里).

  • PDF

Flame Characteristics of Surface Part of Composite Emulsion Exterior Finishes (복합 에멀젼 외장마감재 표면부의 화염 특성)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Yong;Kim, Deuck Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.133-134
    • /
    • 2019
  • As part of recent low-energy policies, thermal insulation standards for buildings are being tightened every year. The importance of external insulation methods is increasing due to the strengthening of insulation standards. Among the main materials used in the external insulation method, dry bit material is a finishing material composed of an organic binder and aggregate. When the fire occurs, the ignition of the surface part causes a direct fire on the thermal insulation material at the rear side when heat energy is concentrated. Therefore, it is important that the finishing material in dry insulation using a dry bit has a low fire spreading property in case of a fire and does not have a sustained combustion. The purpose of this study was to evaluate the fire spreadability by changing the internal fillers while using alkoxide-based acrylic emulsions, hybrid acrylic emulsions, and general acrylic emulsions in order to suppress the fire spreading properties of exterior finish materials.

  • PDF