• Title/Summary/Keyword: external evaluation

Search Result 1,403, Processing Time 0.027 seconds

Effect of emergency core cooling system flow reduction on channel temperature during recirculation phase of large break loss-of-coolant accident at Wolsong unit 1

  • Yu, Seon Oh;Cho, Yong Jin;Kim, Sung Joong
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.979-988
    • /
    • 2017
  • The feasibility of cooling in a pressurized heavy water reactor after a large break loss-of-coolant accident has been analyzed using Multidimensional Analysis of Reactor Safety-KINS Standard code during the recirculation phase. Through evaluation of sensitivity of the fuel channel temperature to various effective recirculation flow areas, it is determined that proper cooling of the fuel channels in the broken loop is feasible if the effective flow area remains above approximately 70% of the nominal flow area. When the flow area is reduced by more than approximately 25% of the nominal value, however, incipience of boiling is expected, after which the thermal integrity of the fuel channel can be threatened. In addition, if a dramatic reduction of the recirculation flow occurs, excursions and frequent fluctuations of temperature in the fuel channels are likely to be unavoidable, and thus damage to the fuel channels would be anticipated. To resolve this, emergency coolant supply through the newly installed external injection path can be used as one alternative means of cooling, enabling fuel channel integrity to be maintained and permanently preventing severe accident conditions. Thus, the external injection flow required to guarantee fuel channel coolability has been estimated.

A Study on Development of Wireless Check-up Device for Captive Flight Test (탑재비행시험용 무선 점검장치 개발에 대한 연구)

  • Ryu, Sang-Gyu;Joo, Junghyun;Ko, Myoungjun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.501-508
    • /
    • 2019
  • In this paper, a study on a wireless check-up method of test equipment for captive flight test(CFT) was conducted. For CFT, test equipment is mounted on a POD, and check-up is carried on the test equipment's. For check-up the POD wirelessly, battery, power distribution unit, wireless communication devices were designed within the POD, and a check-up device is designed outside of the POD. Once the external check-up device sends a 'start signal' to the POD, it performs the overall check-up procedures and transmits the 'end signal' to the external check-up device. Detailed check-up results are stored in an internal storage device, and are possible to read from external check-up device if necessary, thereby improving the reliability of the wireless check-up. By implementing and applying these wireless check-up system, the reliability of the check-up was enhanced by dynamical and movable check-up, and safety is guaranteed as the check-up was carried without access to the aircraft.

Muscle Activity of the Trunk Muscle According to Change of the Leg Width and Arm Posture during Sit to Stand (앉은 자세에서 일어서기 시 발의 너비와 팔의 자세 변화에 따른 근활성도)

  • Jae, Min-Wook;Lee, Han Suk
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.1
    • /
    • pp.91-99
    • /
    • 2019
  • PURPOSE: This study was conducted to evaluate the activity of trunk muscles according to width of the foot and posture of the arm during sit to stand (STS). METHODS: Thirty subjects were recruited and examined for variation in muscle activity of the erector spine, gluteus maximus, gluteus medius and external oblique during different STS conditions; namely, the cross arm basic sit to stand (CBSTS), overhead basic sit to stand (OBSTS), cross arm wide sit to stand (CWSTS), and overhead wide sit to stand (OWSTS). Repeated measures ANOVA (Analysis of Variance) was used for analysis. RESULTS: Erector spinae muscle activity showed a significant increase in the OBSTS condition (p<.05) and external oblique muscle activity showed a significant increase in the OWSTS condition ((p<.05). There was no significant difference in the activity of the gluteus maximus and gluteus medius under any conditions (p>.05). CONCLUSION: During evaluation of the performance of the STS, the CWSTS condition will be useful to decrease the muscle activity of the erector spinae and the OWSTS condition will be useful to increase the muscle activity of the external oblique. The results of this study can be used as an index to find a suitable exercise method for subjects who have back pain or to strengthen the abdomen.

Evaluation of radiological safety according to accident scenarios for commercialization of spent resin mixture treatment device

  • Choi, Woo Nyun;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2606-2613
    • /
    • 2022
  • Spent resin often exceeds radiation limits for safe disposal, creating a need for commercial-scale treatment techniques to reduce resin radioactivity. In this study, the radiological safety of a commercialized spent resin treatment device with a treatment capacity of 1 ton/day was evaluated. The results confirm that the device is radiologically safe in the event of an accident. This device desorbs 14C from the spent resin, allowing disposal as low-level waste instead of intermediate-level waste. The device also reduces overall waste by recycling the extracted 14C. Potential accident scenarios were explored to enable dose assessments for both internal and external exposure while preventing further spillage of the device and processing the spilled resin. The scenarios involved the development of a surface fracture on the resin mixture separator and microwave systems, which were operated under pressure and temperature of 0-6 bar and 0-150 ℃, respectively. In the case of accidents with separator and microwave device, the maximum allowable working time of worker were derived, respectively, considering external and internal exposures. When wearing the respirator corresponding to APF 50, in the case of the microwave device accident scenario, the radiological safety was confirmed when the maximum worker worked within 132.1 h.

A field evaluation of two external transmitter attachment methods for small snakes

  • Park Il-Kook;Jeong, Hojun;Park, Daesik
    • Journal of Ecology and Environment
    • /
    • v.46 no.3
    • /
    • pp.183-189
    • /
    • 2022
  • Background: Radio-telemetry is a useful method to investigate the spatial ecology of species in the wild, by tracking the signal of a transmitter attached to an individual. The method of attaching a transmitter to a snake is representatively divided into surgical implantation, and external attachment, which latter is often used in small snake species. Results: In this study, we evaluated and compared the utility of two external attachment methods, the nylon thread method and the tape method, applied to a small grassland snake species of approximately 50 cm snout-vent length, the Slender racer (Orientocoluber spinalis), on an island in the Republic of Korea. The nylon thread method and the tape method were applied to four and five individuals, and radio-tracked for an average of eight and eleven days, respectively. The nylon thread method caused individual injury and disturbed their movement, while using the tape method, the transmitter package sometimes dropped off, but no injury or movement problems occurred. Conclusions: Considering that poor understanding of how to attach the transmitter makes it difficult to investigate the spatial ecology of small snake species, the tape method, evaluated in this study, could be applied to attach a transmitter and to study spatial ecology of such snakes.

Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss (압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가)

  • Park You-me;Kim Rack-woo;Kim Jun-gyu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.1
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.

Dynamic Analysis of External Fuel Tank and Pylon Using Stick Model (스틱모델을 이용한 외부연료탱크 및 파일런 동특성 해석)

  • Kim, Hyun-gi;Kim, Sung Chan;Park, Sung Hwan;Choi, Hyun-Kyung;Hong, Seung Ho;Ha, Byung Kun
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.1
    • /
    • pp.21-27
    • /
    • 2020
  • Aircraft should be equipped with various external stores for mission performance. Since these external stores may cause structural instability of aircraft, an evaluation of the effects between the aircraft and the external stores is required. For this purpose, an aircraft dynamic characteristics analysis reflecting an external store was performed, and the finite element model for the analysis of aircraft dynamic characteristics should simulate the dynamic characteristics of the component as accurately as possible while using a minimum of the nodes and elements. In this study, a stick model was constructed for dynamic characteristics analysis of the external fuel tank and installation pylon using MSC Patran/Nastran. For the calculation of the equivalent stiffness of the stick model, a simple beam theory was applied to construct the stick model of each part, and the validity of each stick models was confirmed by mode comparison with the fine model. Additionally, the model analysis of the stick model assembly, simulating a pylon equipped with an external fuel tank was performed to confirm that the basic modes required for the analysis of aircraft dynamic characteristics are well extracted. Finally, it was confirmed that the developed stick model assembly could be used for analysis of aircraft dynamic characteristics by comparing the errors in modes between the fine model assembly and the stick model assembly.

Evaluation of Structural Integrity of Aircraft External Fuel Tank for Separation Loads (분리하중에 대한 항공기용 외부연료탱크 구조 건전성 평가)

  • Hyun-gi Kim;Sungchan Kim;Min-su Park;Su-hong An
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.1
    • /
    • pp.64-71
    • /
    • 2024
  • The external fuel tank of an aircraft is a main component that can increase the cruising range of the aircraft. It must be able to be stably separated from the pylon in an emergency situation. At this time, a separation load is applied to the fin and the pivot of the external fuel tank. To stably separate the external fuel tank, the structural soundness of the fin and the pivot must be confirmed. In this study, structural tests were conducted to verify the structural integrity of the external fuel tank pin and pivot when the external fuel tank was separated from the aircraft. Results are then presented. In this paper, a test configuration diagram consisting of the hydraulic and load control equipment, data acquisition system, and pneumatic supply unit used in the structural test was explained. Test installation and test load application plan for each test condition were provided. As results of the structural test, it was found that test load and internal pressure of the test specimen were properly controlled within the allowable range in each test. It was confirmed that serious structural defects in the test specimen did not occur under required load conditions. In conclusion, through structural test for design limit load and design ultimate load, it was proven that the fin and pivot of the external fuel tank for aircraft covered in this study had sufficient structural strength.

A Review on the evaluation of transit quality of service (대중교통 서비스 품질 평가의 국내외 연구 동향 및 시사점)

  • Lee, Sang-Jun;Kim, Hyung-Su;Jung, Dong-Jae;Chang, Justin S.
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1290-1299
    • /
    • 2011
  • Internal and external conditions are currently changing-e.g, climate change increased awareness of energy crisis, and accelerated paradigm about green growth. Accordingly, revitalization of public transportation which enables green transportation system is receiving more attention than the past. Meanwhile, as the incom level increased, people required better quality of service, and consequently, various proposals about improving the services are being promoted. Generally, the quality of the spaces within transit in developed countries is represent the quality of life, thus concerns about the transit service of quality are emerging. This study, through the domestic and abroad studies about transit service quality, redefines transit service quality including rail and reviews the related categories. In that order this study deducts each type of evaluation categories and factors, with comparing and reviewing with various cases in Korea and overseas. Based on the whole process, the paper elicits implications and proposes to the research about the evaluation of transit quality of service.

  • PDF

Nondestructive damage evaluation of deep beams

  • Dincal, Selcuk;Stubbs, Norris
    • Structural Monitoring and Maintenance
    • /
    • v.4 no.3
    • /
    • pp.269-299
    • /
    • 2017
  • This paper presents a Level III damage evaluation methodology, which simultaneously, identifies the location, the extent, and the severity of stiffness damage in deep beams. Deep beams are structural elements with relatively high aspect (depth-to-length) ratios whose response are no longer based on the simplified Euler-Bernoulli theory. The proposed methodology is developed on the bases of the force-displacement relations of the Timoshenko beam theory and the concept of invariant stress resultants, which states that the net internal force existing at any cross-section of the beam is not affected by the inflicted damage, provided that the external loadings in the undamaged and damaged beams are identical. Irrespective of the aspect ratios, local changes in both the flexural and the shear stiffnesses of beam-type structures may be detected using the approach presented in this paper.