• Title/Summary/Keyword: external

Search Result 19,416, Processing Time 0.041 seconds

A Literatual Study of External Treatment from Hyangyakjipsungbang·Tooth (『향약집성방(鄕藥集成方)·치문(齒門)』의 외치법(外治法)에 관한 연구(硏究))

  • Kim, Yong-jin
    • Journal of Korean Medical classics
    • /
    • v.28 no.4
    • /
    • pp.65-77
    • /
    • 2015
  • Objectives : This literature study about dental external treatments from Hyangyakjibsungbang Tooth will invigorate applying the therapeutics in the field of Dentistry. Methods : In this study, the parts related to external treatment in the original text of Hyangyakjibsungbang Tooth were reviewed. Results : Examples of frequently used external method were gargling, applying powder, and brushing one's tooth. These methods are still used in modern dental treatment. Conclusions : Discovering new herbal medicines that provide better effects and developing more precise external treatments will advance dental treatment in Korean medicine.

Four cases of Seborrheic Dermatitis treated by Fermented Yungyo Keumeunhwa Extract External treatment Liquid (발효된 연교금은화 추출물 외치액을 병행한 지루성 피부염 치험 4례)

  • Kim, Ki-Bae;Kim, Tae-Wook;Choi, Sung-Hee
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.26 no.4
    • /
    • pp.101-110
    • /
    • 2013
  • Objectives : The purpose of this study is to report the effect of Fermented Yungyo Keumeunhwa Extract External treatment Liquid on Seborrheic Dermatitis. Methods : Four Seborrheic Dermatitis patients on the face of each Diluted Yungyo Keumeunhwa Extract External treatment Liquid patch was 10 minutes. Results : The Fermented Yungyo Keumeunhwa Extract External treatment Liquid was effective on alleviation of symptoms like flare, scale, uredo and pricking on Seborrheic Dermatitis. Conclusions : The result indicate that Fermented Yungyo Keumeunhwa Extract External treatment Liquid has an available effect on Seborrheic Dermatitis, and authors consider that the additional clinical studies are needed to verify the effectiveness of monotherapy.

Study on the Ultimate Flexural Behavior Analysis of Prestressed Concrete Beam with External Unbonded Tendons (외적 비부착강선을 가진 프리스트레스트 콘크리트 보의 극한휨거동 해석)

  • 오병환;유성원;신정성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.662-667
    • /
    • 1998
  • Recently, the using PSC with external unbonded tendons is increased. However, the behavior of external unbonded tendons is different with that of bonded internal tendon at ultimate state by compatibility condition, the slip with friction at deviator and the change of tendon eccentricity e.t.c., So, the analytical research considered the effect of these inherent characters was performed and the tendency of external unbonded tendons was estimated by numerical examples. By the analytical results, load-deflection relationship and stress increment of external unbonded tendons were similar to those of internal bonded tendon at initial elastic behavior state. Those characters were, however, smaller than those character of internal bonded tendons. For external unbonded tendons, if the 1 deviator which is positioned at maximum moment point and more 2 deviators which are position between maximum moment point and support are existed, the flexural behavior is similar to internal bonded tendons.

  • PDF

External vs internal connection implant system (External vs internal implant : 각각의 장점과 고려사항)

  • Seong, Dong-Jae;Hong, Seoung-Jin;Ha, Seung-Ryong
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.184-190
    • /
    • 2016
  • The osseointegration of titanium implants has been examined over the past 50 years. Many implant systems have been introduced and have become popular to the implant dentistry. The designs of the connection between implant fixture and abutment are divided into external vs internal connection. From beginning, the $Br{\aa}nemark$ system was characterized by an external hexagon. Internal connection has been developed to reduce stress transferred to the bone. These differences may have impact on the clinical procedures and protocols, laboratory and components costs, and incidence of complications. Therefore, the clinician has to know the different biomechanical features and understand their implications to produce successful implant-supported prosthesis with an external or an internal connection system.

  • PDF

Design and Evaluation of Noise Suppressing Hydrophone

  • Im, Jong-in
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.546-560
    • /
    • 2000
  • This paper describes the design and evaluation of a noise suppressing hydrophone that is robust to external noise without sacrificing its performance as a receiver. To increase robustness of the receiver to the external noise, first, effects of location of external noise on its performance are analyzed with the finite element method (FEM). Based on the results, geometrical variations are implemented on the structure with additional air pockets and damping layers that work as acoustic shields or scatterers of the noise, and fourteen trial models are developed for the noise suppressing hydrophone structures. The results show that the effect of the external noise is most significant when it is applied to near the mid-side surface of the hydrophone housing. The external noise is isolated most efficiently when two thin damping layers combined with five air pockets are inserted to the circumference of the hydrophone housing. Overall, of the fourteen structural variations of the hydrophone, the best one shows about 87% reduction in the response of the original structure to external noise.

  • PDF

Effects of External Load and Upper Extremity Postures on Perceived Discomfort (지각 불편도에 대한 외부 부하, 상지 자세의 영향)

  • Kee, Do-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.178-183
    • /
    • 2002
  • The purpose of this study was to quantitatively investigate the effects of external load upper extremity posture on perceived discomfort. An experiment was conducted for measuring discomfort scores depending upon external loads and upper extremity postures, in which the free modules and numeric estimate method of the magnitude estimation was adopted as a tool for obtaining discomfort ratings. The upper extremity postures were controlled by wrist flexion/extension, elbow foexion, shoulder flexion, and shoulder adduction/abduction. The results showed that all experimental variables except shoulder adduction/abduction were significant at ${\alpha}$=0.01 or 0.05. The effect of external load was very much larger than that of upper extremity postures. Therefore, it is recommended that a new posture classification scheme taking effect of external load to into consideration be developed for quantifying postural load.

Nonlinear Analysis on Dynamic Behavior of a Rotor-Bearing System Under External Disturbances (외란을 받는 축-베어링 시스템의 동적 거동에 대한 비선형 해석)

  • 노병후;김경웅
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.334-339
    • /
    • 2001
  • The nonlinear vibration characteristics of hydrodynamic journal bearings with a circumferentially groove are analyzed numerically when the external sinusoidal disturbances are given to the rotor-bearing system continuously. Also, the cavitation algorithm implementing the Jakobsson-Floberg-Olsson boundary condition is adopted to predict cavitation regions in the fluid film more accurately than conventional analysis which uses the Reynolds condition. It is found that the difference between linear and nonlinear analysis is much more remarkable as the amplitude of external disturbance increases, and it depends upon the excitation frequency of external disturbance. It is also shown that the cavity region in the fluid film is increased as the amplitude or excitation frequency of external disturbance increases. The whirling center of the steady state orbit moves closer to the bearing center as the amplitude or the excitation frequency of the external disturbance increases because of smaller range of full film region.

  • PDF

A Study on Performance Elevation of the deteriorated Concrete Girder Bridge by Continuous and External Tendons (연속화와 외부 프리스트레스 도입에 의한 노후된 콘크리트 거더교의 성능향상에 관한 연구)

  • Park, Seung-Bum;Hong, Seok-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.2
    • /
    • pp.159-166
    • /
    • 2000
  • The development of external prestressing methods has been one of the major trends in the concrete bridge constructions over the past decades. One of the promising methods to enhance the flexural strength of a externally prestressed girder is to place the tendons with large eccentricities. The analysis and design of composite girders prestressed by external tendons involve difficulties related mainly to the position of anchorages and the construction sequences. This study was conducted on the concrete bridges reinforced by the continuous girders and the external prestressing. The test results in this study showed that the external prestressing of a composite girder increased the range of the elastic behavior, reduced deflections, increased ultimate strength, and added to the redundancy by providing the multiple stress paths.

  • PDF

A Study on Recalculating Nuclear Energy Generation Cost Considering Several External Costs

  • Kim, Hyun-Jung;Yee, Eric
    • Journal of Power System Engineering
    • /
    • v.22 no.6
    • /
    • pp.5-10
    • /
    • 2018
  • Nuclear energy issues such as safety and social acceptance can not only influence the production costs of generating nuclear power, but also the external costs that are not reflected in market prices. Consequently, the social issues affiliated with nuclear power, beyond a severe accident, require some form of financial expense. The external social issues considered here are accident risk and realization, regulatory costs, and nuclear energy policy costs. Through several calculations and analyses of these external costs for nuclear power generation, it is concluded that these costs range from 7 to 27 \/kWh. Considering external costs are required for making energy plans, it could have an influence on generation costs.

Variable Impedance Control for Industrial Manipulators Based on Sensor-Less External Force Estimator for CPPS (CPPS를 위한 산업용 매니플레이터의 힘 센서리스 외력 추정기 기반 적응 임피던스 제어)

  • Park, Jongcheon;Han, Seungyong;Jin, Yongsik;Lee, Sangmoon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.14 no.5
    • /
    • pp.259-267
    • /
    • 2019
  • This paper proposes a structure of a variable impedance control system based on sensor-less external force estimator of industrial manipulators for cyber physical production systems (CPPS). To implement CPPS, a feedback system is constructed by using the robot operating system (ROS) and an external force estimator which is designed to measure the external force applied to the manipulator without a force sensor. Based on the robot dynamics, the robot-human cooperating system for the cyber physics production system is implemented through a controller that changes the impedance characteristics of the manipulator according to the situation using the external force estimator. Simulation and experimental results verify the effectiveness of the proposed control system.