• Title/Summary/Keyword: exterior coating

Search Result 35, Processing Time 0.018 seconds

Reproducible Synthesis of Periodic Mesoporous TiO2 Thin Film (재현성 있는 메조포러스 TiO2 박막의 제조에 대한 연구)

  • Hur, Jae Young;Lee, Hyung Ik;Park, Young-Kwon;Joo, Oh-Shim;Bae, Gwi-Nam;Kim, Ji Man
    • Korean Chemical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.399-403
    • /
    • 2006
  • There has been numerous reports for the synthesis of mesoporous $TiO_2$ thin films due to not only the high surface area and regular mesoscale pores but also wide band gap and photo activity. However, the synthesis has been restricted by the limited reproducibility mainly due to the extraordinarily fast hydrolysis and condensation rate of titania precursors. In this report, molar composition of reaction batch (HCl/Ti and Ti/P123) and exterior condition (humidity and temperature) during coating and anealing process. Thereafter, the mesoporous $TiO_2$ thin films were characterized by XRD and TEM

A Case Study of a Soyangin Suffering Chest Knotting Syndrome Who Took Hyungbangsabaek-san(荊防瀉白散) and Hyungbangdojeock-san(荊防導赤散) (현훈(眩暈)을 동반한 보행장애(步行障碍)를 가진 환자에 형방사백산과 형방도적산 투여 경과 치험 1례 - 부제 : 소양인(少陽人) 비수한표한병(脾受寒表寒病) 결흉증(結胸證) 환자에 대한 치험례)

  • Im, Ju-Hyuk;So, Hyung-Jin;Heo, Hong;Min, Kyoung-Yoon;Lee, Hae-Yong;Choi, Soon-Young;Ryu, Jae-Hwan;Cho, In-Young
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.3
    • /
    • pp.615-623
    • /
    • 2007
  • We made a comparative study, A patient who had suffered dizziness and ataxia took Hyungbangsabaek-san(荊防瀉白散) at first and next took Hyungbangdojeock-san(荊防導赤散). He was diagnosed as a Soyangin suffering chest knotting syndrome(結胸證) by Sasang constitutional medicine(四象醫學) and took two kinds of herbs in a row. We observed his phase of dizziness and ataxia with the conditions of stool and urine excavation, pink eye, sweating, and tongue color and tongue coating. When he took Hyungbangdojeock-san these conditions improved more than when he took the other one and his dizziness and ataxia also improved. Hyungbangdojeock-san was more useful when the severity of the disease was shallower and he had more exterior syndromes than Hyungbangsabaek-san.

  • PDF

Development of IR Reflective Cool Pigment and Paint (차열도료용 Cool Pigment 및 Paint 개발)

  • Kwon, Myon-Joo;Do, Young-Woong;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3800-3805
    • /
    • 2012
  • Infrared(IR) reflective black cool pigment and paint which is used for interior/exterior materials(IR reflectance >30%) to prevent heat island effect and to increase energy efficiency were studied. Cool pigment was synthesized using mixture of $Fe_2O_3$ and $Cr_2O_3$ with calcination from 900 to $1,200^{\circ}C$. Cool paint was prepared by formulation of cool pigment, acrylic resins, and other additives. Results showed that optimum color fixation of pigment obtained by mole ratio of Fe to Cr was 0.9 with calcination temperature at $1,000^{\circ}C$. The cool paint formulated by 20% pigment and 1.5% dispersive additive with $125{\mu}m$ thickness of coated layer showed optimum IR reflectance. Temperature difference on surface between cool paint and ordinary paint(STD) was $36.5^{\circ}C$ and IR reflectance(TSR) was 39.3% at wavelength from 700 to 2,500nm. And color change was not detected during 500hrs weathering test.

Thermal Performance Assessment of Insulated door by experiment. (실측 실험을 통한 단열문의 열성능 평가)

  • Jang, Cheol-Yong;Kim, Chi-Hoon;Ahn, Byung-Lip;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.47-52
    • /
    • 2011
  • Currently, Exterior wall's U-value about building envelope is 0.36 W/$m^2K$(Central Region), but window's one is 2.1 W/$m^2K$ according to air gap of glazing, filling gas, coating and type of windows. The door"s one is 1.6~5.5 W/$m^2{\cdot}K$ depending on material and configuration of door. As such, energy loss per unit of door is considerably larger like windows. The door for the recognition was relatively low because energy loss through the door is relatively small compared to window area. In this paper, thermal performance was analyzed through simulation targeting the door which has thermal break that can improve the insulation performance and doesn't have one. As a results of simulations, case1 was calculated as the average of 1.63 w/m2k and case 2 was calculated as the average of 4.14 w/m2k. The thermal performance of door depends on the type and condition of insulations. As a results of final simulations, Case1 was calculated as 1.06 w/m2k and Case2 was calculated as 1.27 w/m2k. As a results of the experiments, thermal performance of case 1 was measured as 1.28 w/m2k. Error between experiments and simulations is considered problems encountered when creating the samples. The effect of door frame on the overall thermal performance is slight because it's a small proportion of the door frame.

Experimental validations of fire-resistant materials for protecting LPG small storage tank from building fires (건물 화재 시 LPG소형저장탱크 보호용 화재 저항 재료 성능 실증)

  • Kim, Seung-Hwan;Kim, Kyung-Sik;Heo, Seung-Geon;Lee, Jae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.18-24
    • /
    • 2020
  • The purpose of this study is to validate thermal hinderance effects, i.e., feasibilities, of fire-proof structure for LPG tank exposed to fire from adjacent burning building. The panel materials suggested for the fire-proof structure are (1) 10 mm-thick wood, (2) wood with fireproof coating, (3) 75 mm-thick Expanded Polystyrene, (4) 75 mm-thick glass wool filled sandwich panel, and (5) 75 mm-thick autoclaved lightweight concrete. The square planar fire source of 1 ㎡, a matrix of nozzles releasing 120-140 g/s of LPG, is used to heat up the wall and the tank beyond, mimicking heat transfer from burning exterior wall finishes. The feasibility is tested by inspecting structural integrity after test, and then by examining temperatures at both sides of panels and tank's front surface as well as heat fluxes. As a result, it can be concluded that, among the suggested sample materials, fire-proof wall with ALC panel only showed the feasibility for explosion prevention with the proven evidences of structural integrity and least increase in temperature of tank.