• 제목/요약/키워드: extensometer

검색결과 51건 처리시간 0.029초

316L 스테인리스 강의 고온 저주기 피로 수명식 개발 (Development of a New LCF Life Prediction Model of 316L Stainless Steel at Elevated Temperature)

  • 홍성구;이순복
    • 대한기계학회논문집A
    • /
    • 제26권3호
    • /
    • pp.521-527
    • /
    • 2002
  • In this paper, tensile behavior and low cycle fatigue behavior of 316L stainless steel which is currently favored structural material for several high temperature components such as the liquid metal cooled fast breeder reactor (LMFBR) were investigated. Research was performed at 55$0^{\circ}C$, $600^{\circ}C$ and $650^{\circ}C$ since working temperature of 316L stainless steel in a real field is from 40$0^{\circ}C$ to $650^{\circ}C$. From tensile tests performed by strain controls with $1{\times}10^{-3}/s,\; l{\times}10^{ -4}/s \;and\; 1{\times}10/^{ -5}/ s $ strain rates at each temperature, negative strain rate response (that is, strain hardening decreases as strain rate increases) and negative temperature response were observed. Strain rate effect was relatively small compared with temperature effect. LCF tests with a constant total strain amplitude were performed by strain control with a high temperature extensometer at R.T, 55$0^{\circ}C$, $600^{\circ}C$, $650^{\circ}C$ and total strain amplitudes of 0.3%~0.8% were used and test strain rates were $1{times}10^{-2} /s,\; 1{times}10^{-3} /s\; and\; 1{times}10^{-4} /s$. A new energy based LCF life prediction model which can explain the effects of temperature, strain amplitude and strain rate on fatigue life was proposed and its excellency was verified by comparing with currently used models.

CF8M 스테인리스 강 저주기 환경피로 실험의 주기적 변형률 경화 특성 (Characteristics of the Cyclic Hardening in Low Cycle Environmental Fatigue Test of CF8M Stainless Steel)

  • 정일석;하각현;김태룡;전현익;김영신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.17-22
    • /
    • 2007
  • Low-cycle environmental fatigue tests of cast austenitic stainless steel CF8M at the condition of fatigue strain rate 0.04%/sec were conducted at the pressure and temperature, 15MPa, $315^{\circ}C$ of a operating pressurized water reactor. The used test rig was limited to install an extensometer at the gauge length of the cylindrical fatigue specimen inside the small autoclave. So the magnet type LVDT's were used to measure the fatigue displacement at the specimen shoulders inside the high temperature and high pressure water autoclave. However, the displacement and strain measured at the specimen shoulders is different from the one at the gauge length for the geometry and the cyclic strain hardening effect. FEM calculated the displacement and the strain of the gauge length from the data measured at the shoulders. Tensile test properties in elastic and plastic behavior of CF8M material were used in the FEM analysis. A series of low cycle fatigue tests simulating the cyclic strain hardening effect verified that the FEM calculation was well agreed with the simulated tests. The process and method developed in this study would be so useful to produce reliable environmental fatigue curves of CF8M stainless steel in pressurized water reactors.

  • PDF

심부 급경사 연약층의 채굴 진행에 따른 주변 암반 거동의 탄소성 해석 및 현장계측 (Elasto-plastic Analysis and In-situ Measurement on Rock Behaviors with Stepwise Excavation of the Steep Soft Seam at a Great Depth)

  • 정소걸;신중호
    • 터널과지하공간
    • /
    • 제14권4호
    • /
    • pp.295-303
    • /
    • 2004
  • 연약층과 견고한 암반층이 습곡형태로 혼재된 지질조건의 지하 심부 채굴 현장을 대상으로, 심부 급경사 연약층의 단계적 굴착 진행에 따른 갱도 및 주변 암반의 거동 양상을 전산해석과 현장계측을 통하여 비교 분석하였다. 전산해석에서는 Hoek & Brown의 경험적 파괴기준 및 변형률연화모델을 적용한 탄소성 해석 기법을 이용하였다. 현장계측에서는 유압캡슐, 지중변위계, 내공변위계를 갱도 및 주변 암반에 설치하여 응력과 변위를 계측하였다. 경험적 파괴조건 및 변형률연화모델을 이용한 탄소성 해석은, 현장 지질조건 및 채굴과정의 복잡함에도 불구하고 현장계측결과와 유사한 양상을 보여주어 타당성을 검증할 수 있었다. 이러한 전산해석 및 현장계측의 비교를 통해 지하 굴착 갱도의 변형 거동 과정을 예측하고 이후의 굴착 및 지보보강 설계의 지침을 제공할 수 있을 것이다.

C-밴드 다중시기 SAR 위성 영상을 이용한 녹산국가산업단지 일대의 지반침하 관측 (Ground Subsidence Measurements of Noksan National Industrial Complex using C-band Multi-temporal SAR images)

  • 조민지;이창욱
    • 대한원격탐사학회지
    • /
    • 제30권2호
    • /
    • pp.161-172
    • /
    • 2014
  • 녹산국가산업단지가 설립된 부산 낙동강 하류는 국내에서 연약지반이 가장 깊이 분포하고 있는 지역 중에 하나이다. 연약지반의 깊이가 깊은 해안 매립지의 경우, 장기간에 걸쳐 상당히 큰 잔류침하가 발생하게 된다. 본 연구는 RADARSAT-1과 Envisat의 다중시기 SAR 영상을 이용한 차분간섭기법과 SBAS 시계열 기법을 통해, 녹산산업국가단지에서 2002년 9월부터 2007년 4월 동안에 발생된 지반침하를 관측하였다. 그 결과 연구지역의 동쪽 중앙, 서쪽 중앙, 서쪽, 해안가와 닿아있는 남단에서 최대 10 cm/yr, 평균 6 cm/yr의 속도로 지반침하가 발생되고 있음을 확인하였다. 또한 RADARSAT-1 SAR 영상을 이용한 평균지표변위도는 2001년부터 2002년까지 침하계로 관측된 현장관측자료와 비교 분석되었다. 시간에 따른 지표변위 양상이 거의 선형에 가깝게 나타나므로, 연구지역의 지반침하가 안정권에 접어들 때까지 지속적인 모니터링이 필요할 것으로 사료된다.

CF8M 스테인리스 강 저주기 환경피로 실험의 주기적 변형률 경화 특성 (Characteristics of the Cyclic Hardening in Low Cycle Environmental Fatigue Test of CF8M Stainless Steel)

  • 정일석;하각현;김태룡;전현익
    • 대한기계학회논문집A
    • /
    • 제32권2호
    • /
    • pp.177-185
    • /
    • 2008
  • Low-cycle environmental fatigue tests of cast austenitic stainless steel CF8M at the condition of fatigue strain rate 0.04%/sec were conducted at the pressure and temperature, 15MPa, $315^{\circ}C$ of a operating pressurized water reactor (PWR). The used test rig was limited to install an extensometer at the gauge length of the cylindrical fatigue specimen inside a small autoclave. So the magnet type LVDT#s were used to measure the fatigue displacement at the specimen shoulders inside the high temperature and high pressure water autoclave. However, the displacement and strain measured at the specimen shoulders is different from the one at the gauge length for the geometry and the cyclic strain hardening effect. Displacement of the fatigue specimen gauge length calculated by FEM (finite element method) used to modify the measured displacement and fatigue life at the shoulders. A series of low cycle fatigue life tests in air and PWR conditions simulating the cyclic strain hardening effect verified that the FEM modified fatigue life was well agreed with the simulating test results. The process and method developed in this study for the environmental fatigue test inside the small sized autoclave would be so useful to produce reliable environmental fatigue curves of CF8M stainless steel in pressurized water reactors.

Extensometers results correction in concrete dams: A case study in RCC Zhaveh Dam

  • Ziaei, Ahad;Ahangari, Kaveh;Moarefvand, Parviz;Mirzabozorg, Hasan
    • Structural Monitoring and Maintenance
    • /
    • 제4권1호
    • /
    • pp.17-31
    • /
    • 2017
  • Since extensometers are used to determine the absolute deformation of foundation and abutments and all results are obtained in reference to the base rod, the accuracy of these results has been constantly a subject of debate. In this regard, locating and installing extensometers outside the range of effect zone is also another challenge. The main purpose of this paper is to investigate and modify extensometers results based on the mentioned issues. For this aim, the concrete RCC Zhaveh dam in Iran was selected as the case study. To study the results of extensometers installed in this dam, first, the 3DEC_DP 5.00 software was applied for numerical modeling. Parameters such as discontinuities, dead load and piezometric pressure in the interface of concrete and rock were considered. Next, using the results obtained from 6 extensometers in foundation and abutments and 4 clinometers in dam body, the numerical model was calibrated through back analysis method. The results indicate that the base rod is moved and is not recommended being used as the base point. In other words, because installation of base anchor outside the range of effect zone is not possible due to the operational and economic considerations, the obtained results are not accurate enough. The results indicate a considerable 2-3 mm displacement of the base rod (location of the base anchor) in reference to the real zero point location, which must be added to the base rod results.

복합운동프로그램이 중년여성의 신체구성 및 혈중지질의 변화에 미치는 영향 (The Effect of an Integrated Kinetic Program on the Change of Body Composition and Blood Lipid Components in Middle-aged Women)

  • 양지;이완희
    • The Journal of Korean Physical Therapy
    • /
    • 제24권1호
    • /
    • pp.41-50
    • /
    • 2012
  • Purpose: This study examined the effect of an integrated kinetic program on the body composition of middle-aged and their associated blood lipid components. Methods: The subjects included 50 middle-aged women who resided at J city. Upon their agreements, the subjects were divided into either an experimental group or the control group. There were 25 subjects in each. The integrated kinetic program was conducted during the 6 weeks, and the experimental group was underwent its associated program 5 times a week. There were 3 subjects from each group that were excluded. The extensions were measured with the extensometer, the weights were taken with the body ingredient analysis instrument, and the blood lipid consistency with the blood autoanalyzer. Results: Pre- and Post- the integrated kinetic program, there were statistically significant differences between the body fat mass and the BMI in the experimental group. However, this difference was not significantly different in the control group. Further, there were no statistically significant differences between the two groups of all items in blood lipid components. But the experimental group showed the decrement from TC and TG items after accomplishing the program. Conclusion: The results of this study showed that this kinetic program helps the prevention and functional control of bodily functional decrement to middle-aged women. It is considered that follow-up studies on practically integrated kinetic programs are needed so that they include exercise accomplishments of proper period and good quality nutrition intake. This is in order to maintain muscular quantity and prevent muscle function decrement for the healthy middle-aged women, preparing in aging and menopause.

Analytic adherend deformation correction in the new ISO 11003-2 standard: Should it really be applied?

  • Ochsner, A.;Gegner, J.;Gracio, J.
    • 접착 및 계면
    • /
    • 제5권2호
    • /
    • pp.14-26
    • /
    • 2004
  • For reliable determination of mechanical characteristics of adhesively bonded joints used e.g. as input data for computer-aided design of complex components, the thick-adherend tensile-shear test according to ISO 11003-2 is the most important material testing method. Although the total displacement of the joint is measured across the polymer layer directly in the overlap zone in order to minimize the influence of the stepped adherends, the substrate deformation must be taken into account within the framework of the evaluation of the shear modulus and the maximum shear strain, at least when high-strength adhesives are applied. In the standard ISO 11003-2 version of 1993, it was prescribed to perform the substrate deformation correction by means of testing a one-piece reference specimen. The authors, however, pointed to the excessive demands on the measuring accuracy of the extensometers connected with this technique in industrial practice and alternatively proposed a numerical deformation analysis of a dummy specimen. This idea of a mathematical correction was included in the revised ISO 11003-2 version of 2001 but in the simplified form of an analytical method based on Hooke's law of elasticity for small strains. In the present work, it is shown that both calculation techniques yield considerably discordant results. As experimental assessment would require high-precision distance determination (e.g. laser extensometer), finite element analyses of the deformation behavior of the bonded joint are performed in order to estimate the accuracy of the obtained substrate deformation corrections. These simulations reveal that the numerical correction technique based on the finite element deformation modeling of the reference specimen leads to considerably more realistic results.

  • PDF

반월형 근위 중족골 절골술에 대한 보강적 축성 K-강선 고정술 : 생체역학적 연구 (Additional axial K-wire Fixation for Proximal Crescentic Metatarsal Osteotomy : A Biomechanical Study)

  • 정홍근;김유진
    • 대한족부족관절학회지
    • /
    • 제7권2호
    • /
    • pp.151-156
    • /
    • 2003
  • Purpose: Proximal crescentic metatarsal osteotomy(PMO) is one of the most common procedures for correcting moderate to severe degree hallux valgus deformity. Although screw fixation is used for osteotomy site stability, loss of reduction can occur. The purpose of this study is to compare the sagittal plane stability of the conventional crescentic PMO fixed with a single screw with that of the crescentic PMO fixed with 1 screw and 2 supplemental K -wires. Material and Methods: Ten matched pairs of cadaveric foot specimens were used for the proximal crescentic metatarsal osteotomy. For one foot specimen of each pair, crescentic osteotomy was fixed with 4mm long threaded cannulated screw, while the matched pair was prepared by adding two axial 1.6mm K-wires to the conventionally fixed 4mm screw. The extensometer was used to measure the osteotomy gap as the metatarsal head was loaded continuously until failure using a servohydraulic MTS Mini Bionix test frame. The strength of fixation was normalized with the bone mineral density (BMD) of the paired specimen $(N{\times}cm^{2}/gm)$, Result: The average strength of the crescentic PMO with axial K-wire fixation ($458.8cm^{2}/gm$, S.D. 434.3) was significantly higher than the standard crescentic PMO ($367.5cm^{2}/gm$, S.D. 397,9) (p=0.05). Conclusion: Supplemental fixation with two axial K-wires can be added to the crescentic PMO to enhance the initial fixation stability to prevent the loss of reduction or dorsal malunion.

  • PDF

Establishment of CTE Measurement Procedure for PPLP at 77 K for HTS Power Cables using Double Extensometers

  • Dedicatoria, Marlon J.;Dizon, John Ryan C.;Shin, Hyung-Seop;Sim, Ki-Duk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권4호
    • /
    • pp.24-27
    • /
    • 2012
  • The measurement of the coefficient of thermal expansion (CTE) of polypropylene laminated paper (PPLP) as electric insulating material is important for its practical superconducting device application. The thermal strain induced to HTS tapes and its insulating material during cooling from room temperature might largely affect the critical current ($I_c$) of HTS tapes. In this study, the thermal contraction of PPLP material was measured during cooling from 300 K to 77 K using double extensometers. Initially, the CTE of a brass tape was measured and it was compared with a reference data. It was found that the measured thermal expansion data of the brass material approaches that of the reference one. Based on the results, it was then confirmed that the measurement technique could be applied to thin and flexible samples. Therefore, the same measurement procedure was applied to PPLP material using double extensometers. As a result, the linear CTE of the PPLP at 77 K has been measured to be ${\sim}15.3{\times}10^{-6}/K$. Also, it was found that the thermal contraction characteristics of PPLP was dominated by polypropylene on the cross direction (higher thermal contraction) while it was dominated by Kraft paper on the machine direction (lower thermal contraction). Overall, this measurement procedure could be adopted for the determination of CTE of flexible materials such as PPLP.