• 제목/요약/키워드: extended Nernst-Planck equation

검색결과 4건 처리시간 0.019초

Performance prediction of flat sheet commercial nanofiltration membrane using Donnan-Steric Pore Model

  • Qadir, Danial;Nasir, Rizwan;Mukhtar, Hilmi;Uddin, Fahim
    • Membrane and Water Treatment
    • /
    • 제12권2호
    • /
    • pp.59-64
    • /
    • 2021
  • The rejection of sodium chloride (NaCl) and calcium chloride (CaCl2) single salt solutions were carried out for commercial nanofiltration NFDK membrane. Results showed that the NFDK membrane had a negative surface charge and had a higher observed rejection of 93.65% for calcium (Ca2+) ion and 78.27% for sodium (Na+) ions. Prediction of rejection for aqueous solutions of both salts was made using Donnan Steric Pore Model based on Extended Nernst-Planck Equation in addition to concentration polarization film theory. A MATLAB program was developed to execute the model calculations. Absolute Average Relative Error (% AARE) was found below 5% for real rejection of the NFDK membrane. This research could be used successfully to assess the membrane characterization parameter using a proposed procedure which can reduce the number of experiments.

Modeling the electric transport of HCl and H3PO4 mixture through anion-exchange membranes

  • Koter, Stanislaw;Kultys, Monika;Gilewicz-Lukasik, Barbara
    • Membrane and Water Treatment
    • /
    • 제2권3호
    • /
    • pp.187-205
    • /
    • 2011
  • The electric transport of the mixture of hydrochloric and phosphoric acids through strong base (Neosepta ACM) and weak base (Selemion AAV) anion-exchange membranes was investigated. The instantaneous efficiency of HCl removal from the cathode solution, $CE_{Cl}$, with and without $H_3PO_4$ was determined. It was found that $CE_{Cl}$ was 0.8-0.9 if the number of moles of elementary charge passed through the system, $n_F$, did not exceed ca. 80% of the initial number of HCl moles in the cathode solution, $n_{Cl,ca,0}$. The retention efficiency of $H_3PO_4$ in that range was close to one. The transport of acid mixtures was satisfactorily described by a model based on the extended Nernst-Planck and Donnan equations for $n_F$ not exceeding $n_{Cl,ca,0}$. Among the tested model parameters, most important were: concentration of fixed charges, the porosity-tortuosity coefficient, and the partition coefficient of an undissociated form of $H_3PO_4$. For the both membranes, the obtained optimal values of fixed charge concentration, $\bar{c}_m$, were up to 40% lower than the literature values of $\bar{c}_m$ obtained from the equilibrium measurements. Regarding the $H_3PO_4$ equilibria, it was sufficient to consider $H_3PO_4$ as a monoprotic acid.

NUCLIDE SEPARATION MODELING THROUGH REVERSE OSMOSIS MEMBRANES IN RADIOACTIVE LIQUID WASTE

  • LEE, BYUNG-SIK
    • Nuclear Engineering and Technology
    • /
    • 제47권7호
    • /
    • pp.859-866
    • /
    • 2015
  • The aim of this work is to investigate the transport mechanism of radioactive nuclides through the reverse osmosis (RO) membrane and to estimate its effectiveness for nuclide separation from radioactive liquid waste. An analytical model is developed to simulate the RO separation, and a series of experiments are set up to confirm its estimated separation behavior. The model is based on the extended Nernst-Plank equation, which handles the convective flux, diffusive flux, and electromigration flux under electroneutrality and zero electric current conditions. The distribution coefficient which arises due to ion interactions with the membrane material and the electric potential jump at the membrane interface are included as boundary conditions in solving the equation. A high Peclet approximation is adopted to simplify the calculation, but the effect of concentration polarization is included for a more accurate prediction of separation. Cobalt and cesium are specifically selected for the experiments in order to check the separation mechanism from liquid waste composed of various radioactive nuclides and nonradioactive substances, and the results are compared with the estimated cobalt and cesium rejections of the RO membrane using the model. Experimental and calculated results are shown to be in excellent agreement. The proposed model will be very useful for the prediction of separation behavior of various radioactive nuclides by the RO membrane.

Evaluation of the Effective Charge Density on Low Pressure Nanofiltration with the Separation Characteristics of Monovalent and Divalent Solutes in the Production of Drinking Water

  • Oh, Jeong-Ik;Taro, Urase
    • Environmental Engineering Research
    • /
    • 제16권1호
    • /
    • pp.29-34
    • /
    • 2011
  • The electric charge on a membrane was investigated by analyzing the experimental rejection of various monovalent and divalent ionic solutes. The characteristics of the separation of ionic solutes using various nanofiltration membranes were obtained from an experimental nanofiltration set-up, with a surface area of $40cm^2$ under the operational pressures between 0.25-0.3 MPa. The state of the membrane electric charge was observed using separation coefficients, i.e., the permeation ratio of monovalent to divalent ions. To confirm the state of the membrane charge observed via the separation coefficient, a calculation using the extended Nernst-Planck equation, coupled with the Donnan equilibrium, assuming different electric charge states of the membrane, was compared with the experimental rejection of ionic solutes. The examination of the characteristics of separation using three types of nanofiltration membranes showed that one of the membranes carried a negative/positive double charge density inside, while other two membranes carried either a positive or negative charge density.