• Title/Summary/Keyword: exposure test

Search Result 1,935, Processing Time 0.031 seconds

Attention Degradation of Occupant Driving Vehicle on Cross-country Test Road According to Vibration Exposure Time (야지 시험로 주행 진동 노출 시간에 따른 탑승자의 주의력 저하에 관한 연구)

  • Park, Dong-Jun;Choi, Moon-Gee;Song, Jong-Tak;Ahn, Se-Jin;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.2
    • /
    • pp.155-161
    • /
    • 2017
  • When a military vehicle is driven on a cross-country road, the occupants are exposed to vibration at a body resonance. In case that the exposure continues for too long period, the attention ability of the occupant could be affected by the vibration exposure. In the study, it was experimentally tried to find if there is a correlation between degradation of attention and vibration exposure. Two kinds of test among various psychological attention tests were employed, which were selected with considering a situation of carrying out military mission on vehicle. At the result, the searching test for controlled attention showed significant degradation in the accuracy and performance time in case of exposure at the vibration. And the attention degradation appeared to be greater when the vibration exposure increases. The dual task test for divided attention showed the difference between vibration and non-vibration condition, but showed it is insignificant for the attention to degrade by increasing exposure time.

Characterization of Durability of PC panel by Accelerating Test in Deterioration Chamber and Long-Term Field Exposure Test (촉진열화 및 장기폭로시험에 의한 고성능 PC패널의 내구성능 및 열화특성)

  • Ma, Sang-Joon;Jang, Pil-Sung;Choi, Jae-Suk;Ju, Jung-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1549-1554
    • /
    • 2008
  • In this paper, The evaluation of durability of the PC Panel lining for tunnel structure was examined through the rapid test by carbonation and freezing and thawing. Also for the purpose of improvement of durability. Namely, the durable characteristics of PC Panel lining by carbonation and freezing and thawing, was evaluated by rapid test and long-term field exposure test and main influence factors were derived. As a result of test, Correlation of accelerating test in deterioration chamber and long-term field exposure test, it will be expected that the proposed correlation well to the prediction of life expectancy of structure and is contributed greatly in the future.

  • PDF

A Study on the Temporal Correlation of Long-term Exposure Test and Accelerated Corrosion Test of Rebar (장기폭로 시험과 철근 부식 촉진시험의 시간적 상관성에 관한 연구)

  • Lee, Min-Woo;Park, Sang-Soon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.4
    • /
    • pp.307-313
    • /
    • 2014
  • Recent interest in the increased structural performance and durability evaluation of this concrete structure in a salt damage environment is increasing. The most secure and reliable method of accelerated corrosion test is a method to carry out the rebar corrosion monitoring can be exposed directly to the marine test site exposure. However, long-term exposure testinghas the disadvantage that a long period is necessary. So, a lot of research on RC of salt damage environment have beenpromoted as alternatives to replace this. However, accelerated corrosion test, in the short term only is appropriate and is but an accelerated test method to evaluate the critical chlorine concentration, there is a difficult problem that you still get the answer. It is one of the correlation problems accelerated test correspond to a certain period of exposure environment. Therefore, in this study, to clarify the differences rebar corrosion beginning, through the actual corrosion accelerated test in corrosion time and laboratory test chamber of the structure of the marine environment results in both environments, it is an object of correlation coefficient derived.

Understanding the Degradative Effects of Different Climatological Conditions on Architectural Coatings: Progress Report on Korea Institute of Construction Materials Site Comparison Study of Seosan (Korea) Outdoor Exposure Testing Facility

  • Choi, Yoon;Pyo, Soonjin;Seo, Junsik;Yang, Inmo;Kim, Seungjin;Kim, Sangmyoung
    • Corrosion Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.116-118
    • /
    • 2009
  • Korea Institute of Construction Materials founded Seosan Outdoor Exposure Test Site 2005 at Korea, which is a part of Worldwide Exposure Network (WEN). To evaluate the test site along with other exposure test sites, three different types of paints have been under real time weathering conditions at three major weathering test facilities around the world. Using these test specimens several spectroscopic experiments along with physical tests have been performed. Also acceleration tests have been performed using the same paints. The correlation of weathered paints among three different test facilities and accelerated test results has been compared. From the results the reliability of Seosan Weathering Test Facility and reasonable life time prediction tests are discussed.

Durability Characteristics of RC containing Different Chloride Contents based on Long Term Exposure Test and Accelerated Test (장기폭로시험과 촉진시험에 근거한 염화물 함유량에 따른 철근콘크리트의 내구특성)

  • 권성준;송하원;신수철;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.759-762
    • /
    • 1999
  • The concrete structures possessing good structural integrity can face durability problems due to deteriorations of concrete structures under various environmental conditions. The durability problems weaken the structural integrity in the long run. Especially, the excessive use of sea sand causes serious reinforcement corrosion and carbonation in concrete structures. An accelerated test is often used to predict deterioration as a qualitative measure, but without long term exposure test results or understanding of the relationship between the accelerated test and the long term exposure test, the accelerated test result alone can not be used effectively as a quantitative measure. In this paper, a methodology is proposed to predict the long term deteriorations, based on the result of the short-term accelerated test, of concrete containing different contents of chloride ions. Then, the correlation between two results on the steel corrosion ratio and the carbonation depth is analyzed for concrete with different chloride contents.

  • PDF

Corrosion Durability Evaluation of Uncoated Structural Steel Using Accelerated Exposure Tests (부식촉진실험을 이용한 강교용 무도장 강재의 부식내구성 평가)

  • Kim, In Tae;Itoh, Yoshito
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.79-86
    • /
    • 2007
  • The corrosion durability of steel bridge coatings, such as organic and metallic coatings, is often evaluated by field exposure tests, but such tests take from several years to decades to complete. As a potential method for fast corrosion testing, accelerated exposure tests were considered in this study. The S6-cycle accelerated exposure test, specified in the Japanese Industrial Standards (JIS K5621), was carried out on uncoated structural steels for 30, 60, 90, 120 and 150 days, and the resultant weight loss was determined. The weight loss was compared with that obtained from previous field exposure tests, and acceleration factors of the S6-cycle test to field exposure test sites were determined. The application of the S6-cycle accelerated exposure tests to field environments was presented based on the acceleration factor and the amount of flying salt.

Comparative Estimation of Exposure Level and Health Risk Assessment of Highly Produced Pesticides to Agriculture Operators by Using Default Dermal Absorption Rate or Actual Measurement Values

  • Kim, Su-Hyeon;Lee, Chang-Hun;Kim, Ki-Hun;Jeong, Sang-Hee
    • Biomedical Science Letters
    • /
    • v.22 no.4
    • /
    • pp.199-206
    • /
    • 2016
  • Pesticides are widely used to prevent loss of agricultural production but extensive exposure can induce health problems to pesticide operators. This study was performed to evaluate the health risk of highly produced pesticides used in fruit growing farm land by comparison of estimated exposure level with AOEL using KO-POEM program. AOEL was driven based on NOAEL of each pesticide evaluated by JMPR, EFSA or KRDA. In calculation of exposure level, types of formulation, dilution factors, spraying duration and motor type and exposure protection device were allocated according to actual condition of use. Dermal absorption rate was differently applied among EFSA default values (25% or 75%), general default value (10%) or real test result values to know the plausibility of default values and safety of pesticide to operators in outline. Twenty pesticide ingredients (fungicides and insecticides) were produced more than 30 tons per year, which were mancozeb, chlorothalonil, imidaclopirid and etc in order. Dermal absorption rates obtained from studies were various from 0.07 to 81% but mostly under 10%. The estimated exposure levels showed big differences more than 10 times higher when using EFSA default rate and up to 5 times higher when using general rate of 10% comparing using rates of test results. Mancozeb, chlorthalonil, diazinon and chlorpyrifos presented still higher exposure level than AOEL even when using test absorption rate from study, which suggests that re-evaluation of AOEL or dermal exposure absorption rate or strict management are required for health protection of operators who use those four pesticides in farm land.

Health Status of Electric Utility Workers Exposed to Extremely Low Frequency Electromagnetic Field (ELF-EMF) (근로자들의 극저주파 전자파 노출 수준에 따른 인체 영향 평가)

  • Park, Kyoung-Ho;Ahn, Yong-Ho;Kim, Tai-Jeon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.220-227
    • /
    • 2005
  • Recently, the use of an electrical apparatus has brought up concerns of health risks from exposure to electromagnetic fields. EMF is composed of electric fields and magnetic fields. Heavy exposure to EMF can occur only in the vicinity of high-voltage overhead transmission lines, close to transformers and underground cables, and also close to large electrical machinery. In this thesis I have investigated the hypothesis of the correlation between occupational exposure to ELF-EMF and the risks of leukemia, anemia, cancer. Therefore, the aim of this study is to investigate whether or not ELF-EMF emitted from electric power stations and transformer substations affect some hematological parameters and tumor markers of electric utility workers. The hematological test results and tumor markers under investigation were similar in the two groups but some of parameters such as RBC, AFP, LDH showed significant difference between the two groups from two sample t-test (p<0.05). The exposure group showed increased LDH level compared to the control group by two sample t-tests. In addition, the abnormal LDH level in the exposure group was observed to be clinically significant by ${\chi}^2$-test. However, the levels of RBC, AFP observed were not clinically significant by ${\chi}^2$-test (p>0.05). These results suggested that ELF-EMF does not affect most blood test parameters except LDH of electric utility workers.

  • PDF

Performance Evaluation of Repair Methods for RC structures by Accelerating Test in Combined Deterioration Chamber and Long-Term Field Exposure Test (복합열화촉진실험 및 장기현장폭로실험에 의한 RC구조물 보수공법의 보수성능평가)

  • Kwon Young-Jin;Kim Jae-Hwan;Han Byung-Chan;Jang Seung-Yup
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.349-356
    • /
    • 2006
  • At present, the selecting system and analytic estimation criterion on repair materials and methods of the deteriorated RC structures have not yet been set up in domestic. Under these circumstances, deterioration such as shrinkage crack, corrosion of rebar has been often occurred after repair, and this finally results in too frequent repairs. In this study, three types of repair methods were experimentally investigated by the accelerating test in a combined deterioration chamber and long-term field exposure test. Three types of repair methods applied in this study belong to a group of polymer cement mortar, which is commonly used in repair works. According to the results of this study, durability of repair mortar layers and corrosion properties of recovered rebar could be investigated in short period by the accelerating test in a combined deterioration chamber, which can simulate the condition of repeated high-and-low temperature and repeated dry-and-wet environment, spraying chloride solution and emitting $CO_2$ gas. After 36 month long-term filed exposure test in the coastal area, harmful macro-cracks are observed in the polymer cement mortar layer of some repair methods. These crack are considered to result from drying shrinkage of polymer cement mortar. Also, after 36 month exposure, amount of corrosion area and weight loss of rebar are found to be different according to the types of repair methods.

A Study on Correlation Between Cyclic Drying-Wetting Accelerated Corrosion Test and Long-term Exposure Test (건습반복 부식촉진시험 및 장기폭로시험의 상관성에 대한 연구)

  • Park, Sang-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.136-143
    • /
    • 2016
  • There are various method for evaluating the durability life of concrete structures due to salt damage. The best way is to perform a corrosion test for a rebar embedded in concrete specimen was exposure to marine environment. However, this method has the disadvantage that it takes a long period of time. Also, accelerated corrosion test which was complemented complements the time-consuming weakness is limited to apply because it could not reveal a correlation between long-term exposure test. Accordingly, the purpose of this study is to derive a correlation coefficient between cycle drying-wetting accelerated corrosion test and long-term exposure test. Corrosion initiation time was measured in four types of concrete samples, i.e., two samples mixed with fly ash(FA) and blast furnace slag(BS), and the other two samples having two water/cement ratio(W/C = 0.6, 0.35) without admixture(OPC 60 and OPC 35). The accelerated corrosion test was carried out by two case, i.e., one is a cyclic drying-wetting method(case 1), and the other is a artificial seawater ponding test method(case 2). Whether corrosion occurs, it was measures using half-cell potential method. The results indicated that case 1 is to accelerated the corrosion of rebar about 24~36% as compared with case 2, then the corrosion of rebar embedded in concrete occurred according to the order of OPC60, FA, BS, OPC35. Correlation coefficient between accelerated corrosion test and long-term exposure test, case 1 is 4.23 to 5.42, and case 2 is 6.54 to 7.82.