• Title/Summary/Keyword: exposure test

Search Result 1,950, Processing Time 0.033 seconds

Comparison of Airborne Asbestos Concentrations from Soils in Naturally Occurring Asbestos(NOA) Areas - Activity Based Sampling(ABS) vs. Real-time Asbestos Fiber Monitor(F-1 fiber monitor) - (자연발생석면지역의 토양 내 석면함유율에 따른 비산석면 농도평가 - 활동근거시료채취방법(ABS)과 실시간 섬유 측정 장치(F-1 fiber monitor) 결과 비교 -)

  • Jang, Kwangmyung;Park, Kyunghoon;Choi, Sungwon;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.3
    • /
    • pp.245-256
    • /
    • 2017
  • Objectives: The present study is aimed at performing real-time measurement of fibrous materials using an F-1 fiber monitor, investigating the correlations between the measurements and environmental conditions, and assessing the feasibility of the use of the monitor in actual exposure assessments based on the accuracy and reliability of the device. Methods: Asbestos specimens with a fixed asbestos content were dispersed in a chamber and collected with a particle measuring test device. Measurements obtained by the existing PCM method, and with the F-1 fiber monitor were compared. In addition, concentrations of asbestos fibers obtained by the PCM method, the TEM method, and the F-1 fiber monitor were compared with that of specific ABS scenarios in NOA regions. Correlations of asbestos contents in soil and weather conditions with each method of measurement were analyzed. Results: Laboratory results showed that levels of asbestos fibers measured with each method increased as fiber contents in soil increased. In the accuracy and reproducibility assessment, no significant differences were found between the different methods of measurement. On-site assessment results showed positive correlations among the methods, and these correlations were less significant compared with what was shown by the laboratory results. Levels of asbestos fibers increased as asbestos contents in soil increased, and as temperature increased. Levels of asbestos fibers decreased as humidity increased, and wind speed did not significantly affect the extent to which asbestos fibers were scattered. Conclusions: While it would be premature to replace existing methods with the use of F-1 fiber monitors in real sites based on the results of this study, the monitor may be useful in the screening of the sites, which assesses hazard levels in different regions. Replacement of existing methods with the use of F-1 fiber monitors may be possible after the limitations identified in this study are overcome, and additional assessment data are obtained and reviewed under different conditions to confirm the reliability of the monitor in future research. Obtained assessment results may be used as basic data for the assessment of asbestos hazard in NOA regions.

Inhibitory Activity of Blueberries on UVB-induced Oxidative Stress and Matrix Metalloproteinase Expression in Human Skin Fibroblasts (인간피부 섬유아세포에서 UVB 유도된 산화 스트레스와 기질금속단백질가수분해효소 발현에 블루베리의 저해능)

  • Jang, Young Ah;Kim, Se Gie
    • Journal of Life Science
    • /
    • v.29 no.12
    • /
    • pp.1321-1328
    • /
    • 2019
  • Intermediate-wavelength solar radiation, also known as ultraviolet B (UVB: 290-320 nm) radiation, may cause premature aging and oxidative damage-dependent skin cancer in humans. UVB-induced formation of reactive oxygen species (ROS)-often a consequence of excessive exposure to these rays-could activate matrix metalloproteinases (MMPs) such as MMP-1 and MMP-3. These enzymes break down type I collagen in human fibroblasts. In this study, we assessed the antioxidant and anti-aging effects of ethyl acetate extract of blueberry (EEB). An antioxidant test in blueberries evaluated ROS production using CCD-986sk cells and DPPH assay. In order to evaluate the anti-wrinkle efficacy of blueberries, the MMP-1 production and type 1 procollagen synthesis evaluated and the expression of MMP 1, 3 were tested through Western blot and RT- PCR. EEB exhibited 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging activity and reduced the production of UVB-induced ROS. Also, EEB inhibited UVB-induced processes associated with photoaging and skin cancer, such as reduction in procollagen production and increase in MMP-1 production. More precisely, EEB (50 ㎍/ml) markedly suppressed mRNA and protein levels of MMP-1 and -3. The anti-aging effects are attributable to the antioxidant activity of EEB. These findings indicate that EEB has a protective effect against UVB-induced aging in human fibroblast cells by regulating the levels of type-1 procollagen, MMP-1, and MMP-3.

Identification of Spoilage Bacteria Isolated from Aseptic Packaged Cooked Rice and Application of Acidic Electrolyzed Saline Solution as Water-for-Cooked Rice (무균포장밥으로부터 분리된 부패 미생물의 동정 및 전해산화수의 취반수로서의 이용 효과)

  • Jeong, Jeong-Hwan;Han, Seon-Jin;Cho, Won-Dae;Hwang, Han-Joon
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.788-793
    • /
    • 1999
  • In this study, it was investigated that the isolation and identification of spoilage bacteria from contaminated aseptic packaged cooked rice, the potential for application of acidic electrolyzed saline solution (AESS) as water-for-cooked rice and the microbiological safety of AESS-based cooked rice. Five strains of Bacillus subtilis and a B. cereus strain among the total six isolates were partially identified by biochemical method and by Microbial Identification System (MIS). The bactericidal effect of AESS was similar as 0.1% NaOCl and 70% ethanol solution, or better than that. All of the test microorganisms except Bacillus spp. that were exposed to AESS for five seconds were destructed. The effect of AESS against Bacillus spp. was much better than that of the two solutions and all of them were destructed or inhibited on exposure for five minutes. The pH value of cooked rice prepared using AESS was in the range of 3.6 to 4.3 and was not almost changed through the storage period. Various concentrations of cell suspension of Bacillus isolates were inoculated to cooked rice, which were prepared with tap water and AESS, and stored at $37^{\circ}C$ for two weeks. The result was shown that the bacteria in tap water-based cooked rice appeared normal cell growth, while they were completely repressed in AESS-based cooked rice.

  • PDF

The Epidemiologial Study on the Welders' Pneumoconiosis among Shipyard Welders in Pusan Area (부산지역 조선업 용접공들의 진폐증에 관한 역학적 조사연구)

  • Lee, C.U.;Lee, Jong-Tae;Shon, H.S.;Kim, S.C.;Pae, K.T.;Park, H.J.;Kim, Y.W.;Yun, I.G.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.1 s.25
    • /
    • pp.153-161
    • /
    • 1989
  • Authors studied on the prevalence of 94 cases of pneumoconiosis who were found out through the screening test on 1,062 workers engaged in welding process at 36 shipyard in Pusan area from March 1st, 1986 to November 30th, 1986. The result were as follows; 1. Dust concentration was measured $4.49{\pm}0.54mg/m^3$ in the small scale shipyard while it was $6.25{\pm}1.08mg/m^3$ in the large one. 2. The prevalence of welder's lung was 8.9% (male:8.5%, female:12.0%) and this is consist of 4.9% suspected pneumoconiosis and 4.0% pneumoconiosis more than category 1/0. 3. The prevalence was significantly increased according to the duration of dust exposure(p<0.05), and it showed the increasing tendency by the age group. 4. The prevalence was significantly higher in the large scale shipyard than is the small scale one(p<0.01). 5. The type and shape of opacities were 71.4% of p type and 28.6% of q type, however no pneumoconiosis with r type observed in this study. 6. The main subjective symptoms were the sputum(29.8%), coughing(25.5%), shortness of breath(20.2%), fatique(6.4%), and chest pain(5.3%). In other hand, 57.4% of pneumoconiosis were asymptomatic. 7. The prevalence of pulmonary tuberculosis was radiologically 1.7% in all subjects including 5.3% in pneumoconiosis and 1.3% in no pneumoconiosis(p<0.01).

  • PDF

Analysis of Repeated Measured VAS in a Clinical Trial for Evaluating a New NSAID with GEE Method (퇴행성 관절염 환자를 대상으로 새로운 진통제 평가를 위한 임상시험자료의 GEE 분석)

  • Lim, Hoi-Jeong;Kim, Yoon-I;Jung, Young-Bok;Seong, Sang-Cheol;Ahn, Jin-Hwan;Roh, Kwon-Jae;Kim, Jung-Man;Park, Byung-Joo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.37 no.4
    • /
    • pp.381-389
    • /
    • 2004
  • Objective : To compare the efficacy between SKI306X and Diclofenac by using generalized estimating equations (GEE) methodology in the analysis of correlated bivariate binary outcome data in Osteoarthritis (OA) diseases. Methods : A randomized, double-blind, active comparator-controlled, non-inferiority clinical trial was conducted at 5 institutions in Korea with the random assignment of 248 patients aged 35 to 75 years old with OA of the knee and clinical evidence of OA. Patients were enrolled in this study if they had at least moderate pain in the affected knee joint and a score larger than 35mm as assessed by VAS (Visual Analog Scale). The main exposure variable was treatment (SKI 306X vs. Diclofenac) and other covariates were age, sex, BMI, baseline VAS, center, operation history (Yes/No), NSAIDS (Y/N), acupuncture (Y/N), herbal medicine (Y/N), past history of musculoskeletal disease (Y/N), and previous therapy related with OA (Y/N). The main study outcome was the change of VAS pain scores from baseline to the 2nd and 4th weeks after treatment. Pain scores were obtained as baseline, 2nd and 4th weeks after treatment. We applied GEE approach with empirical covariance matrix and independent(or exchangeable) working correlation matrix to evaluate the relation of several risk factors to the change of VAS pain scores with correlated binary bivariate outcomes. Results : While baseline VAS, age, and acupuncture variables had protective effects for reducing the OA pain, its treatment (Joins/Diclofenac) was not statistically significant through GEE methodology (ITT:aOR=1.37, 95% CI=(0.8200, 2.26), PP:aOR=1.47, 95% CI=(0.73, 2.95)). The goodness-of-fit statistic for GEE (6.55, p=0.68) was computed to assess the adequacy of the fitted final model. Conclusions : Both ANCOVA and GEE methods yielded non statistical significance in the evaluation of non-inferiority of the efficacy between SKI306X and Diclofenac. While VAS outcome for each visit was applied in GEE, only VAS outcome for the fourth visit was applied in ANCOVA. So the GEE methodology is more accurate for the analysis of correlated outcomes.

Study on Image Quality and Radiation Dose due to the Arm Position in the Abdomen/Pelvis CT (복부/골반 CT 검사 시 팔의 위치에 따른 방사선 선량과 영상화질 비교 연구)

  • Lee, Jongwoong;Won, Doyeon;Jung, Jaeeun;Kim, Hyeongyun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.337-342
    • /
    • 2015
  • The one-year-follow-up test of abdomen/pelvis from 10 patients who were scanned more than twice a years were analyzed the radiation dose and image quality depend on the position of the arm retrospectively from January to December in 2013. There were classified two groups, group A was examined with raising an arm on standard position and group B was performed with lowering an arm, respectively. Group A of an average mAs from the first dose amount was shown 11.4% less compared to Group B. And the value of CTDI from Group B also was investigated 11.3% less. To compare the quality comparison of the second image as histogram value, the value of max from both of two groups was measured similarly. However, a big difference was shown from the value of min and SD, the short dose was appeared depends on the position of arm even though Group A was radiated more than Group B. Less exposure to the medical image quality only by working CT scan when the examiner actively raise the arm before the development and testing of high-end equipment introduction of complex algorithms for obtaining an optimized image will be provided to the patient.

Development of liquid target for beam-target neutron source & two-channel prototype ITER vacuum ultraviolet spectrometer

  • Ahn, B.N.;Lee, Y.M.;Dang, J.J.;Hwang, Y.S.;Seon, C.R.;Lee, H.G.;Biel, W.;Barnsley, R.;Kim, D.E.;Kim, J.G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.421-422
    • /
    • 2011
  • The first part is about development of a liquid target for a neutron source, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target neutron source. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the one operating at high neutron fluxes with no need for water cooling. There is no inherent target lifetime for the liquid target neutron generator when used with continuous refreshment of the target surface exposed to the energetic beam. In this work, liquid target containing hydrogen has been developed and tested in vacuum environment. Potentially, liquid targets could allow a point neutron source whose spatial extension is on the order of 1 to $10{\mu}m$. And the second is about the vacuum ultraviolet (VUV) spectrometer which is designed as a five-channel spectral system for ITER main plasma measurement. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4 nm~31.8 nm) and No. 4 (29.0 nm~60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The two gratings are positioned at different optical distances and heights as designed. To study the appropriate detector for ITER VUV system, two different electronic detectors of the back-illuminated charge coupled device and the micro-channel plate electron multiplier were installed and the performance has been investigated and compared in the same experimental conditions. The overall system performance was verified by measuring the spectrums.

  • PDF

Knowledge and attitude change towards radiation protection after radiation safety management education in dental hygiene students (치위생과 학생들의 학업관련 특성에 따른 방사선안전관리 교육 후 방사선 방어에 대한 지식과 태도의 변화)

  • Kim, Sung-Ae;Lee, Ji-Young;Hwang, Se-Hyun;Cho, Mi-Suk;Park, Jung-Hyun;Jung, Nam-Yeong;Yu, Byeng-Chul
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.101-109
    • /
    • 2015
  • Objectives: The purpose of the study is to investigate the knowledge and attitude towards radiation protection after radiation safety management education in dental hygiene students. Methods: After receiving informed consents, a self-reported questionnaire was carried out for 135 dental hygiene students in Busan on June 17 for preliminary survey and September 3 for post-education survey, 2011. The questionnaire was modified from Han and consisted of 5 questions of general characteristics, 6 questions of radiation use, 7 questions of scholastic characteristics, 15 questions of knowledge towards radiation safety management, and 15 questions of attitude towards radiation safety management. Cronbach's alpha was 0.808 in the knowledge towards radiation safety management. Attitude towards radiation safety management included 15 questions of general attitude towards radiation safety management, individual and patient, and attitude toward radiation exposure reduction measured by Likert 5 scale. Cronbach's alpha was 0.970 in the attitude towards radiation safety management. Data were analyzed using SAS version 9.2 for educational analysis, technical analysis and multivariate analysis, paired t-test, and GLM. Results: Significant differences were shown in the knowledge and attitudes towards radiation safety management; the level of knowledge was respectively $9.8{\pm}3.0$ and $12.9{\pm}1.9$ points before and after education, and the level of attitude was $4.28{\pm}0.51$ and $4.53{\pm}0.47$ before and after the education. The levels of knowledge and attitude according to general characteristics showed a significant differences in grade and academic results. Post-education survey suggested that the education is very important and necessary and can change the knowledge and attitude towards radiation safety management in the dental hygiene students. Conclusions: Through the radiation safety management education, the levels of knowledge and attitude towards radiation safety management have changed significantly, which showed that the radiation safety management education proved to be very effective. Therefore, an effective radiation safety management education program is necessary to improve the levels of knowledge and attitude towards radiation safety management in the dental hygiene students.

Effects of Exogenous Insulin-like Growth Factor 2 on Neural Differentiation of Parthenogenetic Murine Embryonic Stem Cells

  • Choi, Young-Ju;Park, Sang-Kyu;Kang, Ho-In;Roh, Sang-Ho
    • Reproductive and Developmental Biology
    • /
    • v.36 no.1
    • /
    • pp.33-37
    • /
    • 2012
  • Differential capacity of the parthenogenetic embryonic stem cells (PESCs) is still under controversy and the mechanisms of its neural induction are yet poorly understood. Here we demonstrated neural lineage induction of PESCs by addition of insulin-like growth factor-2 (Igf2), which is an important factor for embryo organ development and a paternally expressed imprinting gene. Murine PESCs were aggregated to embryoid bodies (EBs) by suspension culture under the leukemia inhibitory factor-free condition for 4 days. To test the effect of exogenous Igf2, 30 ng/ml of Igf2 was supplemented to EBs induction medium. Then neural induction was carried out with serum-free medium containing insulin, transferrin, selenium, and fibronectin complex (ITSFn) for 12 days. Normal murine embryonic stem cells derived from fertilized embryos (ESCs) were used as the control group. Neural potential of differentiated PESCs and ESCs were analyzed by immunofluorescent labeling and real-time PCR assay (Nestin, neural progenitor marker; Tuj1, neuronal cell marker; GFAP, glial cell marker). The differentiated cells from both ESC and PESC showed heterogeneous population of Nestin, Tuj1, and GFAP positive cells. In terms of the level of gene expression, PESC showed 4 times higher level of GFAP expression than ESCs. After exposure to Igf2, the expression level of GFAP decreased both in derivatives of PESCs and ESCs. Interestingly, the expression level of $Tuj1$ increased only in ESCs, not in PESCs. The results show that IGF2 is a positive effector for suppressing over-expressed glial differentiation during neural induction of PESCs and for promoting neuronal differentiation of ESCs, while exogenous Igf2 could not accelerate the neuronal differentiation of PESCs. Although exogenous Igf2 promotes neuronal differentiation of normal ESCs, expression of endogenous $Igf2$ may be critical for initiating neuronal differentiation of pluripotent stem cells. The findings may contribute to understanding of the relationship between imprinting mechanism and neural differentiation and its application to neural tissue repair in the future.

Bioanalytical method validation for determination of arsenic speciation in dog plasma using HPLC-ICP/MS (Dog 혈장 중 HPLC-ICP/MS를 이용한 비소 화학종 분석법 검증)

  • Kim, Jong-Hwan;Kwon, Young Sang;Shin, Min-Chul;Kim, Su Jong;Seo, Jong-Su
    • Analytical Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.234-241
    • /
    • 2016
  • The approach presented in this article refers to the bioanalytical method validation for the detection and quantitative determination of arsenic species including arsenite (As(III)), arsenate (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) in dog plasma by high-performance liquid chromatography inductively coupled plasma mass spectrometry (HPLC-ICP/MS). The arsenic species were separated using an agilent As speciation column by a mobile phase of 2 mM sodium phosphate monobasic, 0.2 mM ethylenediaminetetraacetic acid disodium salt dehydrate, 10 mM sodium acetate, 3 mM sodium nitrate and 1 % ethyl alcohol at pH 11 (adjusted with 1M NaOH). The method validation experiment was obtained selectivity, linearity, accuracy, precision, matrix effect, recovery, system suitability, dilution integrity and various stabilities. All calibration curves showed good linearity (R2>0.999) within test ranges. The lower limit of quantitation (LLOQ) was 5 ng/mL for As(III), As(V) and DMA, and 20 ng/mL for MMA. The system suitability and dilution values were within 6.5 % and 7.7 %. Subsequently, the developed and validated HPLC-ICP/MS method was also successfully applied to determine the arsenic speciation in dog plasma samples, and the recoveries for the spiked samples were in the range of 91.5–102.2 %. Therefore, this method could be applied to the evaluation of arsenic exposure, health effect assessment and other bio-monitoring studies in biological samples.