• Title/Summary/Keyword: exposure sources

Search Result 405, Processing Time 0.036 seconds

Distribution of Organic and Inorganic Arsenic Species in Groundwater and Surface Water Around the Ulsan Mine (울산광산 주변지역 수계에서 유기 및 무기 비소 종 분포)

  • Kim, Youn-Tae;Woo, Nam-Chil;Yoon, Hye-On;Yoon, Cheol-Ho
    • Economic and Environmental Geology
    • /
    • v.39 no.6 s.181
    • /
    • pp.689-697
    • /
    • 2006
  • Distribution and speciation of arsenic in water resources was investigated in the Ulsan mine area. In 62% of uoundwater samples from the mine area, total As concentrations exceeded 0.05 mg/l, the Korean Drinking Water Standard. As(V) was the major type in groundwater with minor As(III). Arsenic species appeared to be in transition stages following redox changes after exposure to the air through the monitoring wells. In areas around the mine, the mine and Cheongog spring appeared to be the sources of arsenic contamination of water resources. The spring showed 0.345 mg/1-As, as much as seven times of the Korean standard. Groundwater and stream samples showed As-concentrations greater than 0.05 mg/l in 30% and 33% samples, respectively, and 60 and 67% of samples exceeded 0.01 mg/l of WHO guideline, respectively. Again, As(V) was a dominant species, however, several samples had As(III) in appreciable levels. In one stream sample, organic species including DMA and AsB were detected in low levels, probably resulted from transformation or related biogeochemical processes.

Contents of Sulfur, Fluorine, Wax and Chlorophyll in Needle Tissue and Needle Growth of Pinus thunbergii as Bioindicators of Air Pollution (대기오염(大氣汚染) 지역의 해송엽내(海松葉內) 수용성(水溶性) 황(黃), 불소(弗素), WAX, 엽록소(葉綠素) 함량(含量) 및 엽(葉) 생장(生長)의 변화와 생물지표성(生物指標性))

  • Kim, Joon Sun;Kim, Yong Hwan;Lee, Han Yol
    • Journal of Korean Society of Forest Science
    • /
    • v.82 no.4
    • /
    • pp.347-353
    • /
    • 1993
  • Accumulation of air pollutants such as $SO_2$ and HF, chlorophyll contents, wax concentrations in needle tissue and needle growth of Pinus thunbergii were studied to verify possibilities of bioindicators of air pollution in Yochon Industrial Complex from July to October, 1991. The concentrations of water-soluble sulfur and fluorine increased nearer to the pollution sources regardless of sampling time, but water-soluble sulfur varied little during investigation and fluorine accumulated more with the passage of time. Total chlorophyll contents decreased a little in the slightly polluted site but sharply in the heavily polluted site. The higher the pollution level was, the more decreased chloroform-extractable wax. Air pollution exposure inhibited needle growth of Pinus tbunbergii during the latter part of growth period. Water soluble sulfur, fluorine and wax concentrations in needle of Pinus thunbergii were rather wood sensitive indicators of susceptibility to ambient air pollution from early July to early October. Chlorophyll contents seemed to be able to be used as a bioindicator of air pollution in early stage of needle development and in the severely polluted area. In the meanwhile needle length must be used as a bioindicator in latter part of growing season.

  • PDF

Studies on the Effect of Environmental Pollution on the Structure of Plant Community (환경오염(環境汚染)이 식물군집(食物群集)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kim, Tae-Wook;Lee, Kyong-Jae;Park, In-Hyeop;Kim, Joon-Seon
    • Korean Journal of Environmental Agriculture
    • /
    • v.2 no.1
    • /
    • pp.35-44
    • /
    • 1983
  • In order to elucidate the change of plant community of natural forests caused by air pollution in the area of Mt. Dosjil of Ulsan city, 25 study subplots, 5 subplots from each 5 plots were set up. These plots lay along gradients of chronic exposure to airborne sulfur dioxide ($SO_2$), fluorides(F) and possibly other pollutants. Total nitrogen, organic matter, available $P_2O_5$, and CEC were generally depressed near industrial sourecs of air pollutants. The author found a total 7 species near sources of air pollutants and 13 species at the utmost plot from air pollutants. Number of individuals, species diversity, evenness, similarity index and biomass were generally depressed near the industrial source of air pollutants. Tolerant plants to air pollution is Cyperus amuricus, Calamagrostis arundinacea, Bidens bipinnata, Cocculus trilobus, Digtaria sanguinalis, Persicaria hydropiper, Pinus thunbergii, Ambrosia artemisiifolia var. elatior, Rhododendron schlippenbachii and Robinia pseudoacacia. It contains 4.41ton/ha of aboveground biomass of Robinia pseudoacacia in damaged forest by air pollution and 39.47ton/ha of it in the non-attacked forest. The annual net production is 0.67ton/ha. yr in damaged forest and $7.73ton/ha{\cdot}yr$ in the non-attacked forest.

  • PDF

$In$ $Vitro$ Development of Goat Parthenogenetic Oocytes Derived from Different Activation Methods (도축장 유래 산양난자의 단위 발생 유기 방법에 따른 체외 발달)

  • Yun, Yun-Jin;Park, Kyeong-Jin;Park, Hee-Sung
    • Journal of Embryo Transfer
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2012
  • Efficient oocyte activation is a key step for the success of nuclear transfer in cloning. Ionomycin sequentially combined with 6-DMAP is now widely used to activate normal oocytes for analytical studies of oocyte activation and to activate reconstructed oocytes after nuclear transfer. The present study investigated sources of oocytes, duration of ionomycin and 6-DMAP, laser and electric stimulation in goat oocyte activation in order to optimize the protocols. Goat ovaries were collected in individual abattoirs during the breeding season and were delivered to the laboratory within 6 h in saline with 100 IU/ml streptomycin and 0.05 mg/ml penicillin. The oocytes were denuded from the cumulus cell by pipetting with 0.2% hyaluronidase in PBS at 20~22 hr post maturation. Oocytes with the polar body were selected and assigned to four groups for parthenogenetic activation. To examine the effect of duration of ionomycin treatment, oocytes after 20~22 hr of maturation were treated with 2.5 uM ionomycin for 1 or 5 min times and then cultured in 2 mM 6-DMAP for 2 or 4 hr. The activated oocytes were cultured in mSOF at $38.5^{\circ}C$ in $CO_2$ 5%, $O_2$ 5% and $N_2$ 90% multi incubator. Cleavage and blastocyst development was observed at 48 hr and day 8 of culture $in$ $vitro$, respectively. Activation rates of oocytes exposed to ionomycin for 1 min(86.4%) were significantly higher than those treated for 5 min(74.3%) duration. This indicated that 1 min ionomycin treatment was most suitable for activation of goat oocytes. The duration of 6-DMAP treat duration was in 2 mM 6-DMAP for 2 hr after 1 min exposure to 2.5 uM ionomycin. The activation rate of oocytes incubated in 6-DMAP for 2 hour(82.5%) was significantly higher than those in oocytes treated with 4 hr(75.5%).

Emission Characteristics of Volatile Organic Compounds from Building Flooring Materials (건축용 바닥재로부터의 휘발성유기화합물 방출특성)

  • Yun, Joong-Seop;Lee, Myong-Hwa;Eom, Seok-Won;Kim, Min-Young;Kim, Jong-Ho;Kim, Shin-Do
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.973-978
    • /
    • 2010
  • The emission of volatile organic compounds (VOCs) from building materials is one of great concerns due to maintain airtight condition of a building to reduce energy consumption, and it causes the deterioration of indoor air quality. Therefore, the emission characterization of VOCs from building materials is necessary to improve indoor air quality. Emission characteristics of VOCs from a plywood flooring that is one of the most commonly used materials in an under-heating system, and from an adhesive that is generally used to stick a plywood flooring to a concrete floor were investigated using an emission chamber test in this study. It was found that the VOCs emission factor was dependent upon and proportional to indoor temperature, and the emission characteristics were closely related to the existing places and conditions of VOCs sources inside the building materials. Maximum emission factors of hexane and toluene from building materials were generally observed at the beginning, however, only that of toluene from a plywood flooring was shown after 6 hours from the beginning. It could be considered that the existing place and condition of toluene source inside a plywood flooring could influence on the VOCs emission. From this study, bake-out time more than 72 hours could be recommended before moving in to avoid the exposure to high concentration of VOCs emitted from an under-heating system.

Laboratory Evaluation of the Accuracy, Precision, and Inter-instrumental Variance of a Portable Photoionization Detector (휴대용 광이온화 검출기의 정확도, 정밀도 및 기기간 차이에 대한 실험실 평가)

  • Choi, Dongmin;Choi, Youngeun;Yoon, Chungsik;Rhie, Kwangwon;Lee, Yunkeun;Lee, Ikmo;Park, Jeongim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.200-208
    • /
    • 2012
  • Objectives: This study investigated the performance of three separate units of a portable photoionization detector (PID, ppb-RAE 3000) for measuring volatile organic compounds (VOCs) in a laboratory. Methods: A laboratory evaluation of the accuracy, precision, and inter-instrumental variance of three separate units of a portable PID (ppb-RAE 3000) was performed. The evaluation was based on the preparation of a test air sample of known toluene or ethylacetate concentration in a Tedlar$^{(R)}$ bag. The test air sample was monitored and data were logged consecutively by the three PIDs. A certified gas of 50 ppm toluene was also monitored during the test to ensure the reliability of the generated test air sample. Four different concentrations ranging from 0.1 to 2 TLV were used and a series of five measurements for each concentration level was performed. The accuracy was evaluated using National Institute for Occupational Safety and Health (NIOSH) criteria. Results: The results from the oldest ppb-RAE3000 unit among the three test units generally fell outside the NIOSH recommended accuracy criteria of ${\pm}25%$, whereas the other two units produced results which were acceptable at, or greater than, 25 ppm of toluene, or 0.5 TLV. These units also met the NIOSH criteria for some ethylacetate measurements but the results were not consistent. Conclusions: Considering the inconsistent performance of these ppb-RAE 3000 units, this device may not be appropriate for use as an alternative to the standard measurement methods. However, it can serve good survey instruments to identify exposure sources or concentration profiles. For all applications, the ppb-RAE 3000 should be used with frequent calibration checks, additional validation using a reference material, and careful maintenance.

The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation (다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사)

  • Joen, Jeong-In;Lee, Hye-Won;Choi, Hyun-Jin;Jeon, Hyung-Jin;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

Knowledge Modeling and Database Construction for Human Biomonitoring Data (인체 바이오모니터링 지식 모델링 및 데이터베이스 구축)

  • Lee, Jangwoo;Yang, Sehee;Lee, Hunjoo
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.6
    • /
    • pp.607-617
    • /
    • 2020
  • Human bio-monitoring (HBM) data is a very important resource for tracking total exposure and concentrations of a parent chemical or its metabolites in human biomarkers. However, until now, it was difficult to execute the integration of different types of HBM data due to incompatibility problems caused by gaps in study design, chemical description and coding system between different sources in Korea. In this study, we presented a standardized code system and HBM knowledge model (KM) based on relational database modeling methodology. For this purpose, we used 11 raw datasets collected from the Ministry of Food and Drug Safety (MFDS) between 2006 and 2018. We then constructed the HBM database (DB) using a total of 205,491 concentration-related data points for 18,870 participants and 86 chemicals. In addition, we developed a summary report-type statistical analysis program to verify the inputted HBM datasets. This study will contribute to promoting the sustainable creation and versatile utilization of big-data for HBM results at the MFDS.

Evaluation of the Shielding Effect of Lead Apron according to the Energy Spectrum Change of 99mTc (99mTc의 에너지 스펙트럼 변화에 따른 납 앞치마의 차폐 효과 평가)

  • Changyong Yoon;Youngsik Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.889-896
    • /
    • 2023
  • Changes in the energy spectrum were analyzed using 99mTc as a point source and a scattering phantom, and the shielding effect of the lead apron according to the changed gamma ray energy was evaluated. In the gamma ray energy spectrum of the scattering phantom, the photo peak area decreased and the compton scattering area increased compared to the point source. The coefficients for each energy range according to the change in the shape of the gamma ray source showed a reduction rate of up to 66.1 % at a distance of 20 cm compared to the coefficient of the point source, and in the compton scattering area, the coefficient of the scattering phantom was 122.2 % at a distance of up to 40 cm compared to the coefficient of the point source. In the difference in shielding rate according to the distance between the source and the scattering phantom using a gamma camera, the photo peak area showed similar results, but in the Compton scattering area, the shielding rate of the scattering phantom at a distance of 20 cm increased by 29.2 % compared to the shielding rate of the point source. As the distance increased, the difference in shielding rate decreased. In measuring the shielding rate of the lead apron using a radiation dosimeter, the difference in the shielding rate of the scattering phantom was up to 15.3 %, and as the distance increased, the difference in the shielding rate between the two sources decreased. The shielding rate of the lead apron of the scattering phantom is higher than that of the point source, and the effectiveness of the lead apron increases as the distance to the source increases. As a result, wearing a lead apron when directly confronting a patient who has injected radioactive pharmaceuticals is expected to be helpful in reducing radiation exposure.

Estimating the Area of Damage Caused by Gas Pipeline Leakage in Subway Construction Zones (지하철역 공사지역 도시가스 배관 누출로 인한 피해면적 산정)

  • Yang, Yong-Ho;Lee, Jae-Wook;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.419-427
    • /
    • 2024
  • This study assessed the potential impact of gas leakage resulting from accidental damage to buried urban gas pipelines during perforating operation near subway construction sites. The risk of explosions due to ignition sources such as static electricity, arising from gas infiltrating the subway construction site through storm sewers and sewage pipes, was evaluated using the ALOHA program. The results of the threat zone calculation, which input various parameters of urban gas pipelines such as length, diameter, and pressure, indicated that the flammable area within the vapor cloud extended from 1.2 to 1.4 km (red zone), the blast area ranged from 0.8 to 1.0 km (yellow zone), and the jet fire extended from 45 to 61 m (red zone). This study demonstrates that within the flammable area of the vapor cloud, a specific combination of concentration and conditions can increase flammability. The blast area may experience explosions with a pressure of 1.0 psi, sufficient to break glass windows. In the event of a jet fire, high temperatures and intense radiant heat exposure lead to rapid fire propagation in densely populated areas, posing a high risk of casualties. The findings are presented in terms of the sphere of influence and threat zone ranges.