• Title/Summary/Keyword: exposure sources

Search Result 405, Processing Time 0.03 seconds

Relative Influence of Sediments, Food and Dissolved Sources on Ag Bioaccumulation in the Amphipod Leptocheirus plumulosus (오염된 퇴적물로부터 해양저서 단각류 Leptocheirus plumulosus의 은(Ag)축적에서 흡수경로의 상대적 기여도 평가)

  • Yoo, Hoon;Lee, In-Tae;Lee, Byeong-Gweon
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.7 no.2
    • /
    • pp.87-93
    • /
    • 2002
  • A amphipod, Leptocheirus plumulosus was exposed to Ag contaminated sediments to evaluate relative importance of various uptake routes (sediment, porewater, supplementary food) for Ag bioaccumulation in sediment-dwelling marine invertebrates. Additionally, influence of AVS (acid-volatile sulfide) on the partitioning of Ag to porewater and on the Ag bioavailability was determined to evaluate the utility of AVS criteria for the management of metal contaminated sediment. The experimental sediments were spiked with 4 levels of Ag (0.1-3.3 ${\mu}$mol Ag/g) and AVS concentrations were manipulated to 40 or <0.5 ${\mu}$mol/g, then equilibrated for >2 months to allow pore water/particulate distributions similar to nature. A L. plumulosus was incubated in the contaminated sediments with overlying water for 35d. During the exposure, the amphipods was fed with supplementary food ($TetraMin^{(R)}$) with or without Ag contamination. Following exposure, tissue Ag in L. plumulosus was strongly correlated with the weak acid extractable Ag in sediments ($r^{2}$=0.87, p<0.001). The ratio of AVS to Ag-SEM (Ag extracted simulaneouls with AVS) had a strong influence on porewater Ag concentration, consistent with previous studies. However, Ag bioaccumulation in L. plumulosus was not influenced by AVS concentrations. The amphipods fed Ag contaminated food took up ${\sim}$ 1.8 X Ag accumulated by the amphipods fed uncontaminated supplementary diet. The result suggests that the benthic invertebrates exposed to metal contaminated sediments would accumulate metals largely via ingestion of contaminated sediments and food, with minor contribution from dissolved sources of porewater and overlying water.

Radiological Risk Assessment for $^{99m}Tc$ Generator using Uncertainty Analysis (불확실성 분석을 이용한 $^{99m}Tc$ 발생기 사용의 방사선위험도 평가)

  • Jang, H.K.;Kim, J.Y.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.129-139
    • /
    • 2004
  • Recently, much attentions are paid to the risk associated with increased uses of medium size radiation sources in medical and industrial fields. In this study, radiation risks to the worker and to the general public due to $^{99m}Tc$ generator were assessed for both normal and accident conditions. Based on the event tree technique, exposure scenarios for various situations were derived. Uncertainty analysis based on the Monte-Carlo technique was applied to the risk assessment for workers and members of the public in the vicinity of the work place. In addition, sensitivity analysis was performed on each of the five independent input parameters to identify importance of the parameters with respect to the resulting risk. Because the frequencies of normal tasks are fat higher than those of accidents, the total risk associated with normal tasks were higher than the accident risk. The annual dose due to normal tasks were $0.6mSv\;y^{-1}$ for workers and $0.014mSv\;y^{-1}$ for public, while in accident conditions $3.96mSv\;y^{-1}\;and\;0.0016mSv\;y^{-1}$, respectively. Uncertainty range of accident risk was higher by 10 times than that of normal risk. Sensitivity analysis revealed that source strength, working distance and working time were crucial factors affecting risk. This risk analysis methodology and its results will contribute to establishment of risk-informed regulation for medium and large radioactive sources.

A Study on Characteristics of Atmospheric Heavy Metals in Subway Station

  • Kim, Chun-Huem;Yoo, Dong-Chul;Kwon, Young-Min;Han, Woong-Soo;Kim, Gi-Sun;Park, Mi-Jung;Kim, Young-Soon;Choi, Dal-Woong
    • Toxicological Research
    • /
    • v.26 no.2
    • /
    • pp.157-162
    • /
    • 2010
  • In this study, we investigated the atmospheric heavy metal concentrations in the particulate matter inside the subway stations of Seoul. In particular, we examined the correlation between the heavy metals and studied the effect of the heavy metals on cell proliferation. In six selected subway stations in Seoul, particulate matter was captured at the platforms and 11 types of heavy metals were analyzed. The results showed that the mean concentration of iron was the highest out of the heavy metals in particulate matter, followed by copper, potassium, calcium, zinc, nickel, sodium, manganese, magnesium, chromium and cadmium in that order. The correlation analysis showed that the correlations between the heavy metals was highest in the following order: (Cu vs Zn), (Ca vs Na), (Ca vs Mn), (Ni vs Cr), (Na vs Mn), (Cr vs Cd), (Zn vs Cd), (Cu vs Cd), (Ni vs Cd), (Cu vs Ni), (K vs Zn), (Cu vs K), (Cu vs Cr), (K vs Cd), (Zn vs Cr), (K vs Ni), (Zn vs Ni), (K vs Cr), and (Fe vs Cu). The correlation coefficient between zinc and copper was 0.937, indicating the highest correlation. Copper, zinc, nickel, chromium and cadmium, which are generated from artificial sources in general, showed correlations with many of the other metals and the correlation coefficients were also relatively high. The effect of the heavy metals on cell proliferation was also investigated in this study. Cultured cell was exposed to 10 mg/l or 100 mg/l of iron, copper, calcium, zinc, nickel, manganese, magnesium, chromium and cadmium for 24 hours. The cell proliferation in all the heavy metal-treated groups was not inhibited at 10 mg/l of the heavy metal concentration. The only exception to this was with the cadmium-treated group which showed a strong cell proliferation inhibition. This study provides the fundamental data for the understanding of simultaneous heavy metal exposure tendency at the time of particulate matter exposure in subway stations and the identification of heavy metal sources. Moreover, this study can be used as the fundamental data for the cell toxicity study of the subway-oriented heavy metal-containing particulate matter.

Determination of Exposure during Handling of 125I Seed Using Thermoluminescent Dosimeter and Monte Carlo Method Based on Computational Phantom

  • Hosein Poorbaygi;Seyed Mostafa Salimi;Falamarz Torkzadeh;Saeid Hamidi;Shahab Sheibani
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.197-203
    • /
    • 2023
  • Background: The thermoluminescent dosimeter (TLD) and Monte Carlo (MC) dosimetry are carried out to determine the occupational dose for personnel in the handling of 125I seed sources. Materials and Methods: TLDs were placed in different layers of the Alderson-Rando phantom in the thyroid, lung and also eyes and skin surface. An 125I seed source was prepared and its activity was measured using a dose calibrator and was placed at two distances of 20 and 50 cm from the Alderson-Rando phantom. In addition, the Monte Carlo N-Particle Extended (MCNPX 2.6.0) code and a computational phantom with a lattice-based geometry were used for organ dose calculations. Results and Discussion: The comparison of TLD and MC results in the thyroid and lung is consistent. Although the relative difference of MC dosimetry to TLD for the eyes was between 4% and 13% and for the skin between 19% and 23%, because of the existence of a higher uncertainty regarding TLD positioning in the eye and skin, these inaccuracies can also be acceptable. The isodose distribution was calculated in the cross-section of the head phantom when the 125I seed was at two distances of 20 and 50 cm and it showed that the greatest dose reduction was observed for the eyes, skin, thyroid, and lungs, respectively. The results of MC dosimetry indicated that for near the head positions (distance of 20 cm) the absorbed dose rates for the eye lens, eye and skin were 78.1±2.3, 59.0±1.8, and 10.7±0.7 µGy/mCi/hr, respectively. Furthermore, we found that a 30 cm displacement for the 125I seed reduced the eye and skin doses by at least 3- and 2-fold, respectively. Conclusion: Using a computational phantom to monitor the dose to the sensitive organs (eye and skin) for personnel involved in the handling of 125I seed sources can be an accurate and inexpensive method.

Pretreatment of Fish for the determination of polycyclic aromatic hydrocarbons using alkali digestion (알칼리분해를 이용한 어류 중 다환방향족탄화수소의 전처리방법)

  • Hu, Soojung;Lee, Hyomin;Chae, Youngzoo;Yoo, Eun-Ah
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.403-409
    • /
    • 2005
  • Polycyclic Aromatic Hydrocarbons(PAHs) contamination arises from several sources including processing of food(smoking, direct drying, cooking) and environmental contamination of air, water, or soil, the later being considered as the most important. In this study, to establish the analytical method for some PAHs[benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene, indeno(1,2,3-c,d)pyrene] in fish, alkali digestion time, extraction solvents, elution volume of florisil cartridge for clean-up have been optimized. The methodology involved saponification and extraction with n-hexane, clean-up on Sep-Pak florisil cartridges and determination by HPLC/FLD(High Performance Liquid Chromatography/Fluorescence Detector). Overall method recoveries for 8 PAHs spiked into these products ranged from 90 to 106%.

The Treatment of Uterine Cervical Cancer Using High Dose Rate Co-60 Sources (고선량율(高線量率) 강내조사법(腔內照射法)을 이용(利用)한 자궁경암(子宮頸癌) 방사선(放射線) 치료(治療))

  • Kim, G.E.;Suh, C.O.;Lee, D.H.;Park, C.Y.
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.95-102
    • /
    • 1983
  • The radical treatment of uterine cervical cancer by interacavitary radium or cesium, in combination with teletherapy are well known. Although the result of such treatment should not give rise to complacency, problem of radiation exposure to medical staff had not been resolved. Fortunately, many attempts have been made to reduce this hazard, most of which take the form of afterloading applicators with a suitably shielded radioisotope. In order to avoid hazardous radiation exposure to staffs concerned with brachytherapy, RALS using high intensity source of Co-60, have been employed at Yonsei Cancer Center since May, 1979. It allows rectal and bladder doses to be kept low, while maintaining a satifactory usual dose distribution of the other type of applicators, and the short treatment time allow four or five patients to be treated per hour. It also removes much patient's discomfort and the difficulties of nursing these patients. Since the first introduction in Korea, over seven hundred cases with various stage of uterine cervical cancer have been treated on a radical basis at this center last 4 years. These authors have strongly attracted attention to the results in terms of local control rate, survival s and morbidity compared with those of conventional low dose rate radiotherapy. Retrospective interim analysis of data was preliminarily accomplished through the labored follow-up study of 340 cases treated during initial 2 years and the radiobiologic standpoint of high dose rate intracavitary irradiation will be discussed.

  • PDF

Uncertainty Analysis and Application to Risk Assessment (위해성평가의 불확실도 분석과 활용방안 고찰)

  • Jo, Areum;Kim, Taksoo;Seo, JungKwan;Yoon, Hyojung;Kim, Pilje;Choi, Kyunghee
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.6
    • /
    • pp.425-437
    • /
    • 2015
  • Objectives: Risk assessment is a tool for predicting and reducing uncertainty related to the effects of future activities. Probability approaches are the main elements in risk assessment, but confusion about the interpretation and use of assessment factors often undermines the message of the analyses. The aim of this study is to provide a guideline for systematic reduction plans regarding uncertainty in risk assessment. Methods: Articles and reports were collected online using the key words "uncertainty analysis" on risk assessment. Uncertainty analysis was conducted based on reports focusing on procedures for analysis methods by the World Health Organization (WHO) and U.S. Environmental Protection Agency (USEPA). In addition, case studies were performed in order to verify suggested methods qualitatively and quantitatively with exposure data, including measured data on toluene and styrene in residential spaces and multi-use facilities. Results: Based on an analysis of the data on uncertainty, three major factors including scenario, model, and parameters were identified as the main sources of uncertainty, and tiered approaches were determined. In the case study, the risk of toluene and styrene was evaluated and the most influential factors were also determined. Five reduction plans were presented: providing standard guidelines, using reliable exposure factors, possessing quality controls for analysis and scientific expertise, and introducing a peer review system. Conclusion: In this study, we established a method for reducing uncertainty by taking into account the major factors. Also, we showed a method for uncertainty analysis with tiered approaches. However, uncertainties are difficult to define because they are generated by many factors. Therefore, further studies are needed for the development of technical guidelines based on the representative scenario, model, and parameters developed in this study.

Indoor and Outdoor Concentrations of Air Pollutants in Beauty Shops at kwangju Area

  • Son Bu-Soon;Song Mi-Ra;Yang Won-Ho;Park Jong-An
    • Journal of Environmental Science International
    • /
    • v.15 no.2
    • /
    • pp.101-106
    • /
    • 2006
  • The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals that are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCs and particulate matter $(PM_{10})$ during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadways. Personal exposures to VOCs and $PM_{10}$ were related to indoor concentrations of beauty shops. According to the questionnaire, hairdressers complained of sore throat, eye irritation, and nervousness as physical symptoms. The measured mean concentrations of respiratory particulates were $30.5ng/m^3$ in indoor, $30.5ng/m^3$ in outdoor and $44.0ng/m^3$ on personal levels. The personal concentration was found higher than indoor and outdoor concentrations. The heavy metals mean concentrations were shown as indoor (Na>Zn>Cr), outdoor (Cr>Zn>Pb), and personal (Na>Cr>Zn) levels. Conclusively, customers as well as workers in the beauty shops might be highly exposed to air pollutants from indoor and outdoor sources. Therefore, proper management should be taken to improve the indoor air quality in beauty shops.

Development of Monoenergetic Photon Source in the Energe Range below 100 keV by the X-ray Fluorescence Method (형광 X 선을 이용한 100 KeV 이하의 에너지 영역에서의 단색 Photon 선원개발에 관한 연구)

  • Lee, Youn-Myoung;Lee, Kun-Jai;Hah, Suck-Ho;Hwang, Sun-Tae;Lee, Kyung-Ju
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.14-28
    • /
    • 1985
  • The development of mono energetic photon sources using $K_{\alpha}$ fluorescence X-ray of pure material was carried out in the energy range below 100 keV. The monoenergetic photons are very useful in the calibration of the radiation measuring instruments and can be produced as the $K_{\alpha}$ fluorescence X-ray by irradiating the bremsstrahlung to the thin pure metal foils called ‘radiators’. In this experiment, several radiators such as $_{47}Ag,\;_{50}Sn,\;_{68}Er,\;_{70}Yb,\;and\;_{82}Pb$ provide the wide monoenergetic photon energy ranging from 20 keV to 80 keV. By the spectrometry with HpGe LEPS, spectral purity factors which measure the monochrometicity for the $K_{\alpha}$ fluorescence X-ray, were determined as $0.64{\sim}0.94$. Dosimetry for the purpose of the determination of the exposure rate with a 600cc thin window ionization chamber, which was calibrated by the standard free-air ionization chamber, was performed. Exposure rates ranging $8.3{\sim}232.5mR/h$ was obtained according to the $K_{\alpha}$ fluorescence X-ray energy for each radiator.

  • PDF

A Study on the Selection of Optimal Counting Geometry for Whole Body Counter (WBC) (인체 내부방사능 측정용 전신계측기의 최적 검출 모드 선정에 관한 연구)

  • Ko, Jong Hyun;Kim, Hee Geun;Kong, Tae Young;Lee, Goung Jin
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • A whole body counter (WBC) is used in nuclear power plants (NPP) to identify and measure internal radioactivity of workers who is likely to ingest or inhale radionuclides. WBC has several counting geometry, i.e. the thyroid, lung, whole body and gastrointestinal tract, considered with the location where radionuclides are deposited in the body. But only whole body geometry is used to detect internal radioactivity during whole body counting at NPPs. It is overestimated internal exposure dose because this measured values are indicated as the most conservative radioactivity values among the them of others geometry. In this study, experiments to measure radioactivity depending on the counting geometry of WBC were carried out using a WBC, a phantom, and standard radiation sources in order to improve overestimated internal exposure dose. Quantitative criteria, could be selected counting geometry according to ratio of count rates of the upper and lower detectors of the WBC, are provided through statistical analysis method.