• Title/Summary/Keyword: exposure sources

Search Result 405, Processing Time 0.026 seconds

Survey and Evaluation for Exterior Noise of a High Rise Apartment in Seoul (서울시 초고층 아파트의 외부소음 측정과 평가)

  • Lee, Seon-Dong;Park, Yu-Ra;Lee, Sang-Woo;Yoo, Ho-Chun
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.95-101
    • /
    • 2004
  • As a part of acoustical design, it is often necessary to quantify aspects of an existing environment and to predict the result of adding an acoustical treatment. The most common sources of exterior noise, also termed as environmental noise,(or community noise) are traffic noise, air craft noise, industrial noise, etc. Transportation(air, road, and rail)noise is the dominant and most common source of noise exposure in residential neighborhoods, and the annoyance is its most consequential effect. The road traffic noise becomes aggravated due to the rapid increase of vehicles. It has a great effect on the dwelling environment. Therefore we investigate the characteristics and sources of the road traffic noise through grasping the status of the road traffic noise. In the present study, preceding studies investigated the noise level of urban areas in Seoul were reviewed and the noise level of urban areas in Seoul was measured at first, fifth, tenth, and nineteenth floor for two days of weekdays and two days of weekend.

Risk Assessment by Toluene Source Emission Model in Indoor Environments of New Houses (신축 주택의 톨루엔 발생량 모델을 이용한 건강위해성 평가)

  • Kim, Young-Hee;Yang, Won-Ho;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.398-403
    • /
    • 2006
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Understanding the effectiveness of indoor air quality control depends on knowledge of the characteristics of air pollutants in indoor air, especially their quantities and persistence, and the relevance of indoor sources to these factors. Toluene within new and established houses has been determined and factors significant to its presence have been identified. A total of 30 selected houses in Seoul, Asan and Daegu areas that were constructed within 4 years and over 4 years of construction were measured the concentration of toluene from July to September in 2004. Toluene emission decay of double-exponential model exhibited good fit of $Y=276.37e^{-1.21x}(R^{2}=0.34,\;P=0.06)$ for 2 years and then $Y=51.54e^{-0.11x}(R^{2}=0.40,\;P=0.0)$ from 23 years in new houses. In case of living in new houses, noncarcinogenic health effects of exposure to toluene was 1.38 of hazard quotient (HQ) comparing to toluene reference dose of 0.13 mg/kg-day.

Noise Reduction of Reciprocating Type Air Compressors (왕복동식 공기압축기의 소음저감에 관한 공학적 대책 연구)

  • Lee, Kwang-Gil;Park, Jae-Suk
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.12-16
    • /
    • 2006
  • This paper deals with the noise evaluation and noise reduction of a reciprocating air-compressor. The reciprocating air-compressor is widely used in the small and medium sized industrial firms, many employees exposed and irritated by their noise in the workplace. Thus, appropriate noise control actions should be taken to prevent hearing loss due to the its noise exposure. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known to be motor, belts, suction valves, discharge valves, moving parts, and flow-induced noise caused by edges or discontinuities along the flow path including expansions, contractions, junctions and bends. As a result, the main noise sources of the air-compressor are categorized by the suction and discharge noise, valve noise, and compressed air tank noise. Based on the investigations, mufflers are designed to reduce both the suction and discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, polyethylene resin is used the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings. As a result of the countermeasure plans, a noise reduction up to 10dB(A) could be achieved for the air-compressor.

Application of Representative $PM_{2.5}$ Source Profiles for the Chemical Mass Balance Study in Seoul

  • Kang, Choong-Min;Kang, Byung-Wook;SunWoo, Young;Lee, Hak-Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.E1
    • /
    • pp.32-43
    • /
    • 2008
  • Source samples were collected to construct source profiles for 9 different source types, including soil, road dust, gasoline/diesel-powered vehicles, a municipal incinerator, industrial sources, agricultural/biomass burning, marine aerosol, and a coal-fired power plant. Seasonal profiles for 'Chinese aerosol', aerosols derived from the urban area of China, were reconstructed from seasonal $PM_{2.5}$ compositions reported in Beijing, China. Ambient $PM_{2.5}$ at a receptor site was also measured during each of the four seasons, from April 2001 to February 2002, in Seoul. The Chemical Mass Balance receptor model was applied to quantify source contributions during the study period using the estimated source profiles. Consequently, motor vehicle exhaust (33.0%), in particular 23.9% for diesel-powered vehicles, was the largest contributor affecting the $PM_{2.5}$ levels in Seoul, followed by agricultural/biomass burning (21.5%) and 'Chinese aerosol' (13.1%), indicating contributions from long-range transport. The largest contributors by season were: for spring, 'Chinese aerosol' (31.7%); for summer, motor vehicle exhaust (66.9%); and for fall and winter, agricultural/biomass burning (31.1% and 40.1%, respectively). These results show different seasonal patterns and sources affecting the $PM_{2.5}$ level in Seoul, than those previously reported for other cities in the world.

Electromagnetic energy as an impact factor on life processes of a biological object of a plant origin

  • Radko, I.;Nalyvaiko, V.;Okushko, O.
    • The Korean Journal of Food & Health Convergence
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • The foremost problem in the agricultural industry in Ukraine is the issue of improving its energy resources efficiency. The existence of this problem is related to the substantial technological inferiority of the industry to those present in the developed countries, especially in terms of creation of no-waste production technologies of agricultural products. The direct effect on the solving of this issue has the necessity to ensure minimal energy costs during treatment of plant objects. This article presents the research results on the effect of electromagnetic energy on activation of plants development. It was found that each such object has its own individual energy resource and that forceful increase of the latter has specific maximum values and gives rise to the plant development process. At the same time, the implementation of the research results is hindered by some factors, among the most major of which are the following: lack of reliable and complete data on the bioenergy resources of plants, its "natural" chart; unavailability of research on the energy sources interaction processes and its effect on the physiological potential of biological objects, at least at the level of low series, absence of the appropriate electrotechnical equipment, including electromagnetic energy sources.

Comparison of the Mercury Removal Efficiency using TiO2 Powder under Various Light Sources (다양한 광원하에서의 TiO2에 의한 수은제거 효율비교)

  • Lee, Yong-Gyu;Lee, Tai-Gyu;Kim, Woo-Sik
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.170-175
    • /
    • 2005
  • In this study, mercury was removed by $TiO_2$ using fluorescent light and sunlight, instead of UV lamps. A reactor was specially designed to increase the $TiO_2's$ exposure to the light source and to make the rotational speed constant. The contacting surface area between mercury and adsorbents was increased by packing the adsorption bed with mixture of $TiO_2$ and glass beads. The mercury removal efficiency was more than 99% under all light sources tested in this study. The mercury removal efficiency was more than 99% under the fluorescent light or sunlight which is harmless and cheap or free.

Characterization of odourous compounds in air, leachate, stream and well in and around Taju-Bello Dumpsite, Lagos, Nigeria

  • Azeez, L.;Oyedeji, O.A.;Abdulsalami, I.O.;Adewuyi, S.O.
    • Advances in environmental research
    • /
    • v.2 no.2
    • /
    • pp.143-153
    • /
    • 2013
  • This study investigated the concentrations of odourous compounds in air, leachate, stream and well in and around Taju-Bello dumpsite. Meteorological parameters (temperature, relative humidity, wind velocity) and six odour families comprising sulphur ($H_2S$), ammonia ($NH_3$), aromatic (benzene, toluene, ethylbenzene, styrene, p-xylene, m-xylene), aliphatic (hexane), oxygenated (formaldehyde, acetaldehyde) and halogenated (tetrachloroethene, trichloroethene, carbontetrachloride) compounds were measured. Meteorological parameters suggested low dispersal of pollutants at L1 with possible perspiration and suffocation from exposure to high temperature, relative humidity and low wind velocity. The trend of abundance of odourous compounds at studied locations is of the order dumpsite (L1) > leachate (L4) > 100 m away from dumpsite (L2) > 200 m away from dumpsite (L3) > stream (L5) > well (L6). $H_2S$, Oxygenated and aromatic compounds were the major contributors to odour strength in these locations. Correlation, factor and cluster analyses of the data revealed similarities of sources as biogenics and xenobiotics inherent in the wastes as the main sources of these odourous compounds.

Acute methemoglobinemia after a normal diet (일상적인 음식 섭취 후 발생한 급성 메트헤모글로빈혈증)

  • Lee, Sung Kgun;Kang, Jeong Ho
    • Journal of Medicine and Life Science
    • /
    • v.18 no.1
    • /
    • pp.20-23
    • /
    • 2021
  • Methemoglobin is generated by the oxidation of ferrous iron to ferric iron within a hemoglobin molecule. Methemoglobin is unable to bind and transport oxygen, resulting in methemoglobinemia, which can lead to fatal tissue hypoxia. The most common cause of methemoglobinemia is poisoning by oxidizing agents such as dapsone, benzocaine, and primaquine. However, methemoglobinemia can also be caused by normal dietary sources. We present two cases of methemoglobinemia that developed after a normal diet in two male patients. In this case report, the patients suddenly developed dyspnea and cyanosis after eating the same meal. They had no history of suspected poisoning, such as the use of drugs, exposure to chemicals, or gas inhalation. Their symptoms did not improve even after a high dose of oxygen was administered; further, an abnormal 'oxygen saturation gap' was observed. Because of CO-oximetry, the methemoglobin levels of the patients were 50.0% and 46.6%, respectively. We administered methylene blue (1 mg/kg), and the patients recovered completely without any complications. Emergency physicians should, therefore, be aware that methemoglobinemia can also be caused by normal dietary sources. In addition, if the source and route of contamination are unclear, an epidemiological investigation should be conducted.

Measurement of low energy beta radiation from Ni-63 by using peeled-off Gafchromic EBT3 film

  • Ji, Wanook;Kim, Jong-Bum;Kim, Jin-Joo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3811-3815
    • /
    • 2022
  • Ni-63 is pure beta source which emits low energy beta particles. The Ni-63 sources were fabricated to develop the beta-voltaic battery which converts decay energy into electrical energy for power generation. Activity distribution of the source was important factor of power producibility of the beta-voltaic battery. Liquid scintillation counter widely used for measurement of low energy beta emitters was not suitable to measure activity distribution. In this study, we used the peeled-off Gafchromic™ EBT3 film to measure the activity distribution of the Ni-63 source. Absorbed dose was increased proportionally to the source activity and exposure duration. The low energy beta particles could transport the energy into the active layer without the polyester protective layer. Also, Activity distribution was measured by using the peeled-off EBT3 film. Two-dimensional dosimetric distribution was suitable to measure the activity distribution. To use the peeled-off EBT3 film is user-friendly and cost-effective method for quality assurance of the Ni-63 sources for the beta-voltaic battery.

Optimization of Dose Distribution for High Dose Rate Intraluminal Therapy (고선량율 관내 방사선치료를 위한 종양선량분포의 최적화에 대한 연구)

  • Chu, Sung-Sil;Kim, Gwi-Eon;Loh, Juhn-Kyu
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.243-252
    • /
    • 1994
  • The use of high dose rate remote afterloading system for the treatment of intraluminal lesions necessitates the need for a more accurate of dose distributions around the high intensity brachytherapy sources, doses are often prescribed to a distance of few centimeters from the linear source, and in this range the dose distribution is very difficult to assess. Accurated and optimized dose calculation with stable numerical algorithms by PC level computer was required to treatment intraluminal lesions by high dose rate brachytherapy system. The exposure rate from sources was calculated with Sievert integral and dose rate in tissue was calculated with Meisberger equation, An algorithm for generating a treatment plan with optimized dose distribution was developed for high dose rate intraluminal radiotherapy. The treatment volume becomes the locus of the constrained target surface points that is the specified radial distance from the source dwelling positions. The treatment target volume may be alternately outlined on an x-ray film of the implant dummy sources. The routine used a linear programming formulism to compute which dwell time at each position to irradiate the constrained dose rate at the target surface points while minimizing the total volume integrated dose to the patient. The exposure rate and the dose distribution to be confirmed the result of calculation with algorithm were measured with film dosimetry, TLD and small size ion chambers.

  • PDF