Analysis of Noise Special Medical Examination and Work Environment Monitoring results (소음에 대한 특수건강진단 및 작업환경측정 결과 분석)

  • Kim, Kab Bae;Park, Hae Dong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.698-698
    • /
    • 2014
  • According to the analysis of special medical examination and work environment monitoring data, the rate of C1 and D1 on noise hazard exceeded 90% among those of total hazardous factors. The rate of company exceeding noise exposure limit was also more than 90%. The analysis result shows that main ages diagnosed with C1 and D1 was age of 50s. The majority scale company having workers diagnosed with C1 and D1 was the companies employing 5~49 workers. Types of industries which have a large number of companies exceeding noise exposure limit were automobile and trailer manufacturing, metal processing industry and primary metal manufacturing. A large number of work processes exceeding noise exposure limit were forming and processing work, cutting and bending work and grinding. To reduce the number of company exceeding noise exposure limit, the reduction counterplan should be focused on the type of industry and the work process which exceeded noise exposure limit frequently. However, the reduction counterplan is preemptively necessary to the type of industry and the work process which exceeded noise exposure limit consecutively if the purpose of reduction counterplan is not to merely reduce the number of company exceeding noise exposure limit but to abate workers' suffering from noise.

  • PDF

Analysis of Noise Special Medical Examination and Work Environment Monitoring Results (소음에 대한 특수건강진단 및 작업환경측정 결과 분석)

  • Kim, Kab Bae;Park, Hae Dong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.5-12
    • /
    • 2015
  • According to the analysis of special medical examination and work environment monitoring data, the rate of C1 and D1 on noise hazard exceeded 90 % among those of total hazardous factors. The rate of company exceeding noise exposure limit was also more than 90 %. The analysis result shows that main ages diagnosed with C1 and D1 was age of 50s. The majority scale company having workers diagnosed with C1 and D1 was the companies employing 5~49 workers. Types of industries which have a large number of companies exceeding noise exposure limit were automobile and trailer manufacturing, metal processing industry and primary metal manufacturing. A large number of work processes exceeding noise exposure limit were forming and processing work, cutting and bending work and grinding. To reduce the number of company exceeding noise exposure limit, the reduction counterplan should be focused on the type of industry and the work process which exceeded noise exposure limit frequently. However, the reduction counterplan is preemptively necessary to the type of industry and the work process which exceeded noise exposure limit consecutively if the purpose of reduction counterplan is not to merely reduce the number of company exceeding noise exposure limit but to abate workers' suffering from noise.

A Simple Proposition for Improving Industrial Hygiene Air Sampling Methods

  • Paik, Samuel Y.;Zalk, David M.
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.389-392
    • /
    • 2019
  • When conducting an exposure assessment, the primary goal of the industrial hygienist is to fully characterize the worker's exposure during a work shift to compare it with an occupational exposure limit. This applies regardless of the duration of the work activity as an activity that is relatively short in duration can still present exposure in excess of the occupational exposure limit even when normalized over an 8-hr shift. This goal, however, is often impeded by the specification of a minimum sample volume in the published sampling method, which may prevent the sample from being collected or submitted for analysis. Removing the specification of minimum sample volume (or adjusting it from a requirement to a recommendation), in contrast, allows for a broader assessment of jobs that consist of short-duration and high-exposure activities and also eliminates the unnecessary practice of running sampling pumps in clean air to collect a specified, minimum volume.

Survey on Annual Excess Trend for Permissible Exposure Limit of Trichloroethylene (트리클로로에틸렌의 허용기준 적용에 따른 연도별 초과 경향 연구)

  • Kim, Ki-Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.1
    • /
    • pp.21-26
    • /
    • 2019
  • Objective: The aim of this study is to analyze an excess trend for domestic permissible exposure limit of trichloroethylene based on previous literature review. Materials and Methods: The research object is a trichloroethylene among 13 chemical substances regulated with PEL(Permissible Exposure Limit) in Occupational Safety and Health Act. The information utilized from this study is the work environment measurement data from 2004 to 2013. The highest level among concentration data measured at various workplaces was selected as a representative value through data process. N.D. (Not Detected) data was considered as 1/2 of LOD(Limit Of Detection). Results: Among work environment measurement data between 2004 and 2013, the highest number of excess workplace and excess rate(24 sites & 1.15%) was observed in 2008's data when applying the PEL(50 ppm) of trichloroethylene. When they are compared with the ACGIH's TLV-TWA(10 ppm), 2008's data showed the highest number of excess workplace and excess rate(175 sites & 8.37%). The number of excess workplace and excess rate related to PEL of trichloroethylene showed increase trend in 2005 but tended to decrease after 2008. Conclusions: Based on the results obtained from this study, the exposure level of trichloroethylene in case of domestic workers is not considered as a safe phase regardless of the year of work environment measurement year. Thus, a strictly preventive management in workplace should be provided for reducing exposure level of trichloroethylene.

The Occupational Exposure Limit for Fluid Aerosol Generated in Metalworking Operations: Limitations and Recommendations

  • Park, Dong-Uk
    • Safety and Health at Work
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • The aim of this review was to assess current knowledge related to the occupational exposure limit (OEL) for fluid aerosols including either mineral or chemical oil that are generated in metalworking operations, and to discuss whether their OEL can be appropriately used to prevent several health risks that may vary among metalworking fluid (MWF) types. The OEL (time-weighted average; 5 mg/$m^3$, short-term exposure limit ; 15 mg/$m^3$) has been applied to MWF aerosols without consideration of different fluid aerosol-size fractions. The OEL, is also based on the assumption that there are no significant differences in risk among fluid types, which may be contentious. Particularly, the health risks from exposure to water-soluble fluids may not have been sufficiently considered. Although adoption of The National Institute for Occupational Safety and Health's recommended exposure limit for MWF aerosol (0.5 mg/$m^3$ ) would be an effective step towards minimizing and evaluating the upper respiratory irritation that may be caused by neat or diluted MWF, this would fail to address the hazards (e.g., asthma and hypersensitivity pneumonitis) caused by microbial contaminants generated only by the use of water-soluble fluids. The absence of an OEL for the water-soluble fluids used in approximately 80-90 % of all applicants may result in limitations of the protection from health risks caused by exposure to those fluids.

Evaluation of Ride Vibrations of Agricultural Tractors (농업용 트랙터의 승차 진동 수준 평가)

  • Kim, H.J.;Kim, K.U.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.3
    • /
    • pp.151-156
    • /
    • 2008
  • This study was conducted to evaluate ride vibrations experienced by tractor operators during plowing, rotovating, and transporting operations in Korea. Field data of ride vibrations were taken at the operator-seat interface from 49 tractors and analyzed on the basis of ISO 2631-1 and EU Directive 2002/44. Of the measured ride vibrations 15.4% in the plowing and 12.5% in farm road transport exceeded the 8-hour fatigue decreased proficiency boundary in the fore and aft directions at frequencies from 1 to 5 Hz. 93.9% exceeded the 8-hour potential health risk of ISO 2631-1. The ride vibrations exceeding the 8-hour exposure limit were 38.5% in plowing, 31.6% in rotovating, 100% in farm road transport and 88.9% in concrete road transport. Although most tractor operators were not exposed to ride vibrations greater than the 8-hour exposure limit value (ELV) of EU Directive 2002/44, 7.7% of the operators in the plowing experienced greater vibrations than the ELV in the fore-aft direction. Farm road transport produced greater vibrations than any other operations. Concrete road transport, plowing and rotovating operations followed next. Limit criteria for ride vibration exposure differ depending upon the guidelines. Exposure limit of the health guidance caution zone of ISO 2631-1 is lowest among its kinds.

A Survey on Annual Exceedance Trends for the Domestic Permissible Exposure Limit for Benzene (벤젠의 국내 허용기준에 대한 연도별 초과 경향 연구)

  • Lee, Kyunghwa;Kim, Ki-Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.2
    • /
    • pp.144-150
    • /
    • 2018
  • Objectives: The purpose of this study is to analyze the trend for exceedance of the domestic permissible exposure limit of benzene based on a review of the previous literature. Materials and methods: From among 13 chemical substances regulated through a PEL (Permissible Exposure Limit) in the Occupational Safety and Health Act, the research object of this study is benzene. The information utilized is work environment measurement data from 2004 to 2013. The highest level among the concentration data measured at various workplaces was selected as a representative value through the data process. N.D. (Not Detected) data was considered as 1/2 of the LOD (limit of detection). Results: Among the work environment measurement data between 2004 and 2013, the highest number of exceeding workplaces and the excess rate (12 sites and 5.4%) was observed in the 2006 data when applying the current PEL for benzene. When compared with the action level, which means a level one-half of the PEL, 2005's data showed the highest number of exceeding workplaces and greatest excess rate (89 sites & 13.3%). The number of exceeding workplaces and excess rate relative to the PEL for benzene showed an increasing trend in 2004, but tended to decrease after 2007. Conclusions: Based on the results obtained from this study, the exposure level for benzene among domestic workers is not considered to be in a safe phase regardless of the year of work environment measurement. Thus, strict preventive management in workplaces should be provided for reducing exposure to benzene.

Preliminary Evaluation of Radiological Impact for Domestic On-road Transportation of Decommissioning Waste of Kori Unit 1

  • Dho, Ho-Seog;Seo, Myung-Hwan;Kim, Rin-Ah;Kim, Tae-Man;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.4
    • /
    • pp.537-548
    • /
    • 2020
  • Currently, radioactive waste for disposal has been restricted to low and intermediate level radioactive waste generated during operation of nuclear power plants, and these radioactive wastes were managed and disposed of the 200 L and 320 L of steel drums. However, it is expected that it will be difficult to manage a large amount of decommissioning waste of the Kori unit 1 with the existing drums and transportation containers. Accordingly, the KORAD is currently developing various and large-sized containers for packaging, transportation, and disposal of decommissioning waste. In this study, the radiation exposure doses of workers and the public were evaluated using RADTRAN computational analysis code in case of the domestic on-road transportation of new package and transportation containers under development. The results were compared with the domestic annual dose limit. In addition, the sensitivity of the expected exposure dose according to the change in the leakage rate of radionuclides in the waste packaging was evaluated. As a result of the evaluation, it was confirmed that the exposure dose under normal and accident condition was less than the domestic annual exposure dose limit. However, in the case of a number of loading and unloading operations, working systems should be prepared to reduce the exposure of workers.

Determination of Derived Release Limits by the Concentration Factor Method (농축인자법에 의한 유도방출 기준 설정)

  • Byung Woo Kim;Byeung Kyu Kim;Jeong Ho Lee
    • Nuclear Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.267-278
    • /
    • 1985
  • Some kinds of methods have been applied to regulate the exposure doses by the radioactive effluents from nuclear power plants. The essential one is primary dose equivalent limit recommended by the ICRP. When the primary limit cannot be applied directly for regulation, there have been dose equivalent index in case of external exposure, or maximum permissible concentration, annual limit on intake, derived air concentration and maximum permissible body burden in case of internal exposure. But the derived limit is required from the viewpoint of discharge, for those values are inadequate to control discharge rate directly. This study was carried out to derive the release limit for the Wolsung nuclear power plant by the concentration factor method. This method is based on the assumption of steady state transfer between environment compartments.

  • PDF

Exposure to Environmental Endotoxin and Health Effects (환경 중의 엔도톡신 노출 및 건강에 미치는 영향)

  • Park, Ju-Hyeong
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.4
    • /
    • pp.265-278
    • /
    • 2014
  • Microbes such as bacteria, fungi, archaea, protists, and viruses are ubiquitous and people are exposed to them continuously. Endotoxin is a component of the outer membrane of Gram-negative bacteria and a potent proinflammaotry substance. When a person is exposed to environmental endotoxin, an innate immune response is initiated upon the initial recognition and this response produces various inflammatory mediators and recruits inflammatory cells to the exposed tissues. A purified chemical form of endotoxin is called lipopolysaccharide (LPS), and the lipid A portion of the molecule is a biologically active moiety. Exposure to endotoxin may result in various complex health effects depending on time, route, and dose of exposure, as well as host susceptibility. Gene-environment interactions play important roles in health effects of endotoxin exposure, e.g. development or aggravation of asthma. To accurately assess exposure to endotoxin in environmental or epidemiologic studies, methods of sampling, extraction, and analysis must be carefully selected since the selected methods may substantially affect analytical results and there is no internationally-agreed standard method to date. The lack of a standardized method hampers the establishment of exposure-response relationships. While an internationally-agreed health-based exposure limit does not exist, the Dutch Expert Committee on Occupational Safety recently recommended $90EU/m^3$ as a health-based occupational exposure limit. The current article reviews various scientific issues on how we measure environmental endotoxin and the health effects of endotoxin exposure.