• 제목/요약/키워드: exposure dose reproducibility test

검색결과 16건 처리시간 0.022초

엑스선의 조사시간에 따른 형광유리선량계의 빌드업 특성 (Buildup Characteristics of Radiophotoluminescent Glass Dosimeters with Exposure Time of X-ray)

  • 권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권5호
    • /
    • pp.256-263
    • /
    • 2017
  • By using the buildup characteristics of the radiophotoluminescence glass dosimeter(RPLGD), it is aimed to help the measurement of the accurate dose by measuring the radiation dose according to the time of the glass element. Five glass elements were arranged on the table and the source to image receptor distance(SID) was set to 100 cm for the build-up radiation dose measurement of the fluorescent glass dosimeter glass element(GD-352M). Radiation doses and saturation rates were measured over time according to irradiation time, with the tube voltage (30, 60, 90 kVp) and tube current (50, 100 mAs) Repeatability test was repeated ten times to measure the coefficient of variation. The radiation dose increased from 0.182 mGy to 12.902 mGy and the saturation rate increased from 58.3% with increasing exposure condition and time. The coefficient of variation of the glass elements of the fluorescent glass dosimeter was ranged from 0.2 to 0.77 according to the X - ray exposure conditions. X - ray exposure showed that the radiation dose and saturation rate were increased with buildup characteristics, and degeneration of glass elements was not observed. The reproducibility of the variation coefficient of the radiation generator was included within the error range and the reproducibility of the radiation dose was excellent.

동물병원의 방사선발생장치 정도관리에 대한 연구 (Quality Control of Diagnostic X-ray Units for Animal Hospital)

  • 김상우;이지훈;박예슬;임재동;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF

Investigation of Standard Evaluation for the Quality Control of General X-ray Systems

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Byoung-Jun;Park, Deok-Woo;Jung, Byoung-Hoon;Lee, Hyo-Jin;Hong, Ji-Young;Kim, Seung-Chul
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.71-79
    • /
    • 2010
  • Thanks to the great development of technology in radiation, we are now able to reduce radiation exposure to the patients, and the radiographer and expenses in medical sector. We are also trying to produce ideal images which maintain useful information. These kinds of effort are increasing over the world. For that reason, we should get images which include necessary data of patients. Then it also can help to reduce radiation exposure to the patients. Therefore, we need to know the problems that cause a falling off in image's quality and check on generator in case of their electronic and mechanical errors. And moreover, we should anticipate the possibility of devices errors and prevent them with regular quality control. This investigation was conducted in medical institutions, institute of educations and hospitals. They are all in Seongnam-City. We used PMX-III, kVp meter to implement kVp test, mR / mAs output test, light fiel / beam alignment test, Reproducibility of exposure dose, half value layer test, reproducibility of exposure time test. in the case of hospitals, they perceive the importance of regular quality control and organize the regular quality control team so they can be satisfied with the error standard in most experiments. On the other hand, when it comes to medical institutions and institute of educations, they perceive the importance of regular quality control less than hospitals do. Radiographer need to understand the importance of regular quality control and practice it so they can get the fine ideal image with the lower dose to the patient.

  • PDF

진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가 (Usability Evaluation of Foot Pedal Switch in X-ray Radiography System)

  • 권혁진;정홍문;정재은;정경환;원도연
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.651-658
    • /
    • 2018
  • 방사선사는 일반촬영 시에 다양한 환자를 만나게 된다. 노령환자, 유아 등 몸이 불편한 환자를 검사하게 된다. 소규모의 병 의원에는 방사선사가 혼자 업무를 보는 경우가 자주 발생한다. 이러한 경우 방사선사의 두 손은 환자의 자세를 유지하는데 사용되어지기 때문에 촬영에 있어서 어려움을 느끼게 된다. 본 연구는 이러한 문제점을 극복하고자 진단용 방사선 발생 발판 스위치를 고안하여 실험하였다. 제작한 발판 스위치를 진단용 엑스선 촬영장치에 장착하여 조사선량 재현성 시험, kVp, mAs, 백분율평균오차와 같은 정량적 평가를 실시하였다. 결과적으로 발판 스위치 사용에 대한 정량적 평가는 조사선량 재현성 시험에서 변동계수가 0.05이하로 측정되었고 kVp 시험에서는 백분율 평균오차가 ${\pm}10%$ 이내로 측정되었다. mAs 시험에서도 백분율 평균오차가 ${\pm}20%$ 이내로 측정되었다. 이는 진단용 방사선 발생장치의 검사기준 범위에 모두 부합하여 사용상 문제점은 제시되지 않았다. 또한 현재 근무 중인 방사선사를 상대로 유용성에 관한 정성적 평가를 실시하였다. 결론적으로 발판스위치의 엑스선 발생효율의 정량적 평가에서는 실험된 검사가 엑스선 발생장치 장비 기준 범위에 부합하였으며 설문을 통한 평가에서도 먼저 병 의원에서 근무하는 방사선사를 상대로 발판 스위치를 사용한 이후 설문을 통해 발판 스위치에 대한 편리성과 활용성에 대해 설문 실시한 결과는 발판스위치 사용은 임상에서 많은 도움을 줄 수 있는 긍정적인 결과로 나타내었다. 그러므로 진단용 엑스선 촬영용 발판 스위치를 사용하면 방사선 기술자 작업의 신속성과 정확성을 효과적으로 향상시킬 수 있으므로 의료 서비스 만족도를 높이는 데 효과적으로 사용할 수 있을 것이다.

진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리 (The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System)

  • 김상우;임재동;한동균;성열훈
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

수도권지역 일반촬영 장비의 정도관리 분석 (Analyze for the Quality Control of General X-ray Systems in Capital region)

  • 강병삼;이강민;심우용;박순철;최학동;조영권
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.93-102
    • /
    • 2012
  • 방사선 의료기술의 발달로 의료 방사선 영역에서 환자와 종사자의 피폭선량을 최소로 유지하고 많은 정보가 포함된 영상을 제공하고 있다. 그러나 장치의 성능 저하는 선량의 증가와 화질의 저하로 환자 및 의료진에게 손실을 줄 수도 있다. 따라서 영상의 질을 저하시키는 원인을 분석하고 X선 발생장치의 부적합을 점검하여야 하며, 장비의 고장 가능성을 예견하고 방지하기 위해서는 정기적인 정도관리가 반드시 필요하다. 본 연구는 수도권에 소재한 의원, 교육기관 그리고 종합병원을 대상으로 진단방사선안전관리규정의 일반방사선장비 검사기준을 준용하여 관전압시험, mAs시험, 광조아야 오차시험, 조사선량 재현성시험, 반가층시험, 조사시간 재현성 시험을 시행하였다. 개인 및 교육기관의 경우 일반촬영장비 22대를 대상으로 시험한 결과 관전압시험에서 18.2%, 조사선량 재현성시험에서 13.6%, mAs시험에서 9.1% 그리고 반가층 시험에서 13.6%가 부적합으로 측정되었다. 종합병원의 경우 28대의 장비에서는 조사선량재현성시험에서 7.1%, 광조사야 오차시험에서 7.1%, 조사시간 재현성시험에서 7.1% 부적합이 나타났다. 종합병원의 경우 정도관리의 중요성을 인식하고 장비업체의 예방점검 체결 및 원내에 정도관리 팀을 구성하여 적극적인 관리가 이루어지고 있어 대부분의 시험에서 기준을 충족하였으나 개인의원에서는 상대적으로 관리가 미흡한 실정이다.

인버터식 X선장치의 성능평가 시 비접속형 측정기의 유용성 (Usefulness of Non-Invasive Measurement Tool on Performance Evaluation of Inverter Type X-ray Unit)

  • 강세식;김창수;고성진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.123-127
    • /
    • 2008
  • 목 적: 임상에서 인버터식 X선장치의 사용이 보편화됨에 따라 이에 대한 보다 정확하고 간편한 성능평가 방법이 요구되고 있다. 따라서 최근 국내에 소개되어 사용되고 있는 X-Ray Multi-Function Test Device (model : Xi (unfors)-prestige)를 이용한 성능평가의 유용성을 확인하고자 한다. 방 법: 인버터식 X선장치의 성능 평가시 접속형 측정장비로 널리 활용되고 있는 Dynalyzer III를 이용한 성능평가를 기준으로 하여 비접속형 측정장비인 X-Ray Multi-Function Test Device (model: Xi (unfors)-prestige)의 성능평가를 비교 분석하여 그 유용성을 검토하였다. 결 과: 두 측정기에 대한 X선 출력선량은 큰 차이 없이 측정되었으며 촬영조건 등의 변화에 따라서 접속형인 Dynalyzer III가 약간 증가된 값으로 측정되었으며 출력의 재현성은 두 측정기 모두 성능평가 합격 기준 0.05 이하인 0.002 이하로, 직선성은 합격기준인 0.1 이하로 평가되었다. 촬영조건의 정확도에서는 관전압은 1.8과 2, 관전류는 2.01과 2.3, 촬영시간은 T > 0.01 sec에서 ${\pm}10%$ 이하로 나타났다. 모두 성능평가 기준의 허용범위에 있는 것으로 나타났다. 결 론: X-Ray Multi-Function Test Device (model: Xi (unfors)-prestige) 측정기를 이용한 인버터식 X선장치의 X선 출력의 재현성, 직선성과 촬영조건의 정확도에 대한 성능평가의 유용성을 확인하였다.

  • PDF

동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가 (Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan)

  • 이재상;이규찬;이승환;배성복;박종엽
    • 핵의학기술
    • /
    • 제20권1호
    • /
    • pp.59-65
    • /
    • 2016
  • 동적신장검사는 신장기능을 영상화하는 대표적인 방법이다. 동적신장검사에서 저선량 방사성의약품의 사용으로 기존 동적신장검사와 저선량을 사용한 신장검사의 비교를 통한 동적신장검사의 재현성을 평가해 보기로 했다. 본 비교실험을 통해 재현성이 우수할 경우 환자에 투여하는 방사선량을 줄인 동적신장검사법을 활용하고 환자의 피폭을 줄이고자 한다. 감마카메라 장비로는 Orbiter, SymbiaE (Siemens, Germany)를 사용하였고, 2013년 1월부터 2014년 2월까지 370 Mbq (10mCi)을 사용한 환자와 동일 환자 중 2014년 3월부터 2015년 7월까지 185 Mbq (5 mCi)을 사용한 환자를 대상으로 $^{99m}Tc-DTPA$사용 검사 21명과 $^{99m}Tc-MAG_3$사용 검사 20명 총 41명을 대상으로 데이터를 선별하였다. 결과 영상의 Renogram에서 Peak 지점의 프레임을 선택하여 신장의 관심영역과 배후방사능의 관심영역을 설정하고 K/B ratio를 구하여 비교하였다. $^{99m}Tc-DTPA$를 사용한 검사에서 370 Mbq을 사용하였을 때의 K/B ratio는 평균 $5.67{\pm}0.8$이었고, 185 Mbq을 사용하였을 때는 평균 $5.62{\pm}0.87$로 큰 차이를 보이지 않았다. $^{99m}Tc-MAG_3$를 사용한 검사에서도 신장/배후방사능 비는 370 Mbq을 사용 시 평균 $14.95{\pm}2.58$과 185 Mbq을 사용 시 평균 $14.56{\pm}2.02$로 큰 차이를 보이지 않았다. Paired sample t-test결과 p-value는 $^{99m}Tc-DTPA$ 0.566, $^{99m}Tc-MAG_3$ 0.363로 같은 비교집단 간 차이점이 없음을 확인하였다. 동일 환자를 대상으로 선량을 370 Mbq에서 185 Mbq로 줄였을 때의 동적신장검사의 재현성은 우수한 것으로 확인 되었다. 저선량 동적신장검사는 기존 감마카메라의 성능 개선 없이 재현성이 우수한 결과를 얻을 수 있고 환자의 피폭 또한 줄일 수 있을 것으로 사료된다.

  • PDF

자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가 (Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device)

  • 권오영;이창훈;용금주;진선희;정다빈;허영철
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.1049-1056
    • /
    • 2021
  • 본 연구의 목적은 일반촬영용 호흡 동기화 장치를 개발하여 호흡 협조가 어려운 환자의 가슴 검사를 할 때 들숨의 재현성을 높이는 것이다. 공기압 센서를 이용하여 호흡 동기화 장치를 자체 제작(X-RSD)하였고, 심폐소생술용 마네킹에 벤틸레이터를 연결하여 공기를 주입하였다. 이때 주입한 공기의 양은 SkillReporting 장치를 이용하여 정량화하였다. 마네킹의 가슴에 X-RSD를 위치한 후 공기의 양을 200-700 cc까지 100 cc 씩 총 6 단계를 나눠서 검사하였다. 오차 평가는 총 80회씩 반복 측정하여 X-RSD의 민감도를 측정하였고 민감도는 100%로 매우 정교한 결과 값을 얻을 수 있었다. 이후 가슴 측면검사를 X-RSD를 보면서 검사한 영상과, 암맹 검사한 영상을 비교평가 하였고, X-RSD의 폐 용적이 암맹 검사보다 용적도 크게 측정되고, 편차도 적게 측정되었다. 종합적으로 X-RSD를 이용하면 협조가 어려운 환자의 가슴검사에 도움을 줄 수 있으며, 일반촬영의 재촬영률을 줄여 전체적인 피폭선량 감소에 기여가 가능할 것이라 사료된다.

이동형 전산화단층촬영장치의 기본 안전 및 필수 성능 기준을 마련하기 위한 연구 (A Study on Establishment of Basic Safety and Essential Performance Criteria of Mobile Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.261-267
    • /
    • 2021
  • As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.